Changes for page 07 Adjustments
Last modified by Iris on 2025/07/24 11:03
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -121,12 +121,8 @@ 121 121 122 122 (% class="table-bordered" style="margin-right:auto" %) 123 123 (% class="warning" %)|(% style="text-align:center; vertical-align:middle" %)[[image:image-20220611152630-1.png]] 124 -|(% style="text-align:left; vertical-align:middle" %)((( 125 -Before adjusting the rigidity grade, set the appropriate load inertia ratio P03-01 correctly. 124 +|(% style="text-align:left; vertical-align:middle" %)Before adjusting the rigidity grade, set the appropriate load inertia ratio P03-01 correctly. 126 126 127 -**VD2L drive does not support automatic gain adjustment!** 128 -))) 129 - 130 130 The value range of the rigidity grade is between 0 and 31. Grade 0 corresponds to the weakest rigidity and minimum gain, and grade 31 corresponds to the strongest rigidity and maximum gain. According to different load types, the values in the table below are for reference. 131 131 132 132 (% class="table-bordered" %) ... ... @@ -745,8 +745,6 @@ 745 745 746 746 Low-frequency vibration suppression is suitable for working conditions where the motor vibrates during deceleration and shutdown after the position command is sent, and the vibration amplitude gradually decreases. The use of the low-frequency vibration suppression function is effective in reducing the time to complete positioning due to vibration effects. 747 747 748 -**VD2L drive does not support low frequency vibrartion suppression.** 749 - 750 750 (% style="text-align:center" %) 751 751 ((( 752 752 (% class="wikigeneratedid img-thumbnail" style="display:inline-block" %)