... ... @@ -168,9 +168,11 @@
168 168  )))|(% style="text-align:center; vertical-align:middle; width:105px" %)(((
169 169  Effective immediately
170 170  )))|(% style="text-align:center; vertical-align:middle; width:87px" %)0|(% style="text-align:center; vertical-align:middle; width:83px" %)0 to 2|(% style="width:431px" %)(((
171 -* 0: Rigidity grade self-adjusting mode. Position loop gain, speed loop gain, speed loop integral time constant, torque filter parameter settings are automatically adjusted according to the rigidity grade setting.
172 -* 1: Manual setting; you need to manually set the position loop gain, speed loop gain, speed loop integral time constant, torque filter parameter setting
173 -* 2: Online automatic parameter self-adjusting mode (Not implemented yet)
171 +0: Rigidity grade self-adjusting mode. Position loop gain, speed loop gain, speed loop integral time constant, torque filter parameter settings are automatically adjusted according to the rigidity grade setting.
172 +
173 +1: Manual setting; you need to manually set the position loop gain, speed loop gain, speed loop integral time constant, torque filter parameter setting
174 +
175 +2: Online automatic parameter self-adjusting mode (Not implemented yet)
174 174  )))|(% style="text-align:center; vertical-align:middle" %)-
175 175  
176 176  Table 7-4 Details of self-adjusting mode selection parameters
... ... @@ -795,6 +795,8 @@
795 795  
796 796  Type A vibration suppression is suitable for durational vibration during motor operation or shutdown. Use Type A suppression to help reduce vibrations at specific frequencies that occur during motion (For the situation where the vibration continues to maintain and the vibration amplitude is almost constant after the command is completed.) As shown in Figure 7-14.
797 797  
800 +**VD2L drive does not support type A vibration suppression.**
801 +
798 798  (% style="text-align:center" %)
799 799  (((
800 800  (% class="wikigeneratedid img-thumbnail" style="display:inline-block" %)