745 745  
746 746  Low-frequency vibration suppression is suitable for working conditions where the motor vibrates during deceleration and shutdown after the position command is sent, and the vibration amplitude gradually decreases. The use of the low-frequency vibration suppression function is effective in reducing the time to complete positioning due to vibration effects.
747 747  
748 -**VD2L drive does not support low frequency vibrartion suppression.**
749 -
750 750  (% style="text-align:center" %)
751 751  (((
752 752  (% class="wikigeneratedid img-thumbnail" style="display:inline-block" %)
... ... @@ -795,8 +795,6 @@
795 795  
796 796  Type A vibration suppression is suitable for durational vibration during motor operation or shutdown. Use Type A suppression to help reduce vibrations at specific frequencies that occur during motion (For the situation where the vibration continues to maintain and the vibration amplitude is almost constant after the command is completed.) As shown in Figure 7-14.
797 797  
798 -**VD2L drive does not support type A vibration suppression.**
799 -
800 800  (% style="text-align:center" %)
801 801  (((
802 802  (% class="wikigeneratedid img-thumbnail" style="display:inline-block" %)