... ... @@ -168,11 +168,9 @@
168 168  )))|(% style="text-align:center; vertical-align:middle; width:105px" %)(((
169 169  Effective immediately
170 170  )))|(% style="text-align:center; vertical-align:middle; width:87px" %)0|(% style="text-align:center; vertical-align:middle; width:83px" %)0 to 2|(% style="width:431px" %)(((
171 -0: Rigidity grade self-adjusting mode. Position loop gain, speed loop gain, speed loop integral time constant, torque filter parameter settings are automatically adjusted according to the rigidity grade setting.
172 -
173 -1: Manual setting; you need to manually set the position loop gain, speed loop gain, speed loop integral time constant, torque filter parameter setting
174 -
175 -2: Online automatic parameter self-adjusting mode (Not implemented yet)
171 +* 0: Rigidity grade self-adjusting mode. Position loop gain, speed loop gain, speed loop integral time constant, torque filter parameter settings are automatically adjusted according to the rigidity grade setting.
172 +* 1: Manual setting; you need to manually set the position loop gain, speed loop gain, speed loop integral time constant, torque filter parameter setting
173 +* 2: Online automatic parameter self-adjusting mode (Not implemented yet)
176 176  )))|(% style="text-align:center; vertical-align:middle" %)-
177 177  
178 178  Table 7-4 Details of self-adjusting mode selection parameters
... ... @@ -747,8 +747,6 @@
747 747  
748 748  Low-frequency vibration suppression is suitable for working conditions where the motor vibrates during deceleration and shutdown after the position command is sent, and the vibration amplitude gradually decreases. The use of the low-frequency vibration suppression function is effective in reducing the time to complete positioning due to vibration effects.
749 749  
750 -**VD2L drive does not support low frequency vibrartion suppression.**
751 -
752 752  (% style="text-align:center" %)
753 753  (((
754 754  (% class="wikigeneratedid img-thumbnail" style="display:inline-block" %)
... ... @@ -797,8 +797,6 @@
797 797  
798 798  Type A vibration suppression is suitable for durational vibration during motor operation or shutdown. Use Type A suppression to help reduce vibrations at specific frequencies that occur during motion (For the situation where the vibration continues to maintain and the vibration amplitude is almost constant after the command is completed.) As shown in Figure 7-14.
799 799  
800 -**VD2L drive does not support type A vibration suppression.**
801 -