Changes for page 07 Adjustments
Last modified by Iris on 2025/07/24 11:03
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -704,8 +704,9 @@ 704 704 )))|(% style="text-align:center; vertical-align:middle; width:121px" %)((( 705 705 Effective immediately 706 706 )))|(% style="text-align:center; vertical-align:middle; width:99px" %)100|(% style="text-align:center; vertical-align:middle; width:102px" %)0 to 100|(% style="width:362px" %)((( 707 -1. 0: all truncated 708 -1. 100: all passed 707 +0: all truncated 708 + 709 +100: all passed 709 709 )))|(% style="text-align:center; vertical-align:middle; width:96px" %)- 710 710 |=(% style="text-align: center; vertical-align: middle; width: 113px;" %)P04-07|(% style="text-align:center; vertical-align:middle; width:155px" %)1st notch filter width|(% style="text-align:center; vertical-align:middle; width:115px" %)((( 711 711 Operation setting ... ... @@ -712,10 +712,13 @@ 712 712 )))|(% style="text-align:center; vertical-align:middle; width:121px" %)((( 713 713 Effective immediately 714 714 )))|(% style="text-align:center; vertical-align:middle; width:99px" %)4|(% style="text-align:center; vertical-align:middle; width:102px" %)0 to 12|(% style="width:362px" %)((( 715 -1. 0: 0.5 times the bandwidth 716 -1. 4: 1 times the bandwidth 717 -1. 8: 2 times the bandwidth 718 -1. 12: 4 times the bandwidth 716 +0: 0.5 times the bandwidth 717 + 718 +4: 1 times the bandwidth 719 + 720 +8: 2 times the bandwidth 721 + 722 +12: 4 times the bandwidth 719 719 )))|(% style="text-align:center; vertical-align:middle; width:96px" %)- 720 720 |=(% style="text-align: center; vertical-align: middle; width: 113px;" %)P04-08|(% style="text-align:center; vertical-align:middle; width:155px" %)2nd notch filter frequency|(% style="text-align:center; vertical-align:middle; width:115px" %)((( 721 721 Operation setting ... ... @@ -727,8 +727,9 @@ 727 727 )))|(% style="text-align:center; vertical-align:middle; width:121px" %)((( 728 728 Effective immediately 729 729 )))|(% style="text-align:center; vertical-align:middle; width:99px" %)100|(% style="text-align:center; vertical-align:middle; width:102px" %)0 to 100|(% style="width:362px" %)((( 730 -1. 0: all truncated 731 -1. 100: all passed 734 +0: all truncated 735 + 736 +100: all passed 732 732 )))|(% style="text-align:center; vertical-align:middle; width:96px" %)- 733 733 |=(% style="text-align: center; vertical-align: middle; width: 113px;" %)P04-10|(% style="text-align:center; vertical-align:middle; width:155px" %)2nd notch filter width|(% style="text-align:center; vertical-align:middle; width:115px" %)((( 734 734 Operation setting ... ... @@ -735,10 +735,13 @@ 735 735 )))|(% style="text-align:center; vertical-align:middle; width:121px" %)((( 736 736 Effective immediately 737 737 )))|(% style="text-align:center; vertical-align:middle; width:99px" %)4|(% style="text-align:center; vertical-align:middle; width:102px" %)0 to 12|(% style="width:362px" %)((( 738 -1. 0: 0.5 times the bandwidth 739 -1. 4: 1 times the bandwidth 740 -1. 8: 2 times the bandwidth 741 -1. 12: 4 times the bandwidth 743 +0: 0.5 times the bandwidth 744 + 745 +4: 1 times the bandwidth 746 + 747 +8: 2 times the bandwidth 748 + 749 +12: 4 times the bandwidth 742 742 )))|(% style="text-align:center; vertical-align:middle; width:96px" %)- 743 743 744 744 Table 7-11 Notch filter function code parameters ... ... @@ -760,22 +760,30 @@ 760 760 )))|=(% style="text-align: center; vertical-align: middle; width: 157px;" %)((( 761 761 **Effective time** 762 762 )))|=(% style="text-align: center; vertical-align: middle; width: 121px;" %)**Default value**|=(% style="text-align: center; vertical-align: middle; width: 116px;" %)**Range**|=(% style="text-align: center; vertical-align: middle; width: 462px;" %)**Definition**|=(% style="text-align: center; vertical-align: middle; width: 115px;" %)**Unit** 763 -|=(% style="text-align: center; vertical-align: middle; width: 134px;" %)P4-11|(% style="text-align:center; vertical-align:middle; width:258px" %)Enable low-frequency vibration suppression function|(% style="text-align:center; vertical-align:middle; width:127px" %)((( 771 +|=(% style="text-align: center; vertical-align: middle; width: 134px;" %)P4-11((( 772 +〇 773 +)))|(% style="text-align:center; vertical-align:middle; width:258px" %)Enable low-frequency vibration suppression function|(% style="text-align:center; vertical-align:middle; width:127px" %)((( 764 764 Operation setting 765 765 )))|(% style="text-align:center; vertical-align:middle; width:157px" %)((( 766 766 Effective immediately 767 767 )))|(% style="text-align:center; vertical-align:middle; width:121px" %)0|(% style="text-align:center; vertical-align:middle; width:116px" %)0 to 1|(% style="width:462px" %)When the function code is set to 1, enable the low-frequency vibration suppression function.|(% style="width:115px" %) 768 -|=(% style="text-align: center; vertical-align: middle; width: 134px;" %)P4-12|(% style="text-align:center; vertical-align:middle; width:258px" %)Low-frequency vibration suppression frequency|(% style="text-align:center; vertical-align:middle; width:127px" %)((( 778 +|=(% style="text-align: center; vertical-align: middle; width: 134px;" %)P4-12((( 779 +〇 780 +)))|(% style="text-align:center; vertical-align:middle; width:258px" %)Low-frequency vibration suppression frequency|(% style="text-align:center; vertical-align:middle; width:127px" %)((( 769 769 Operation setting 770 770 )))|(% style="text-align:center; vertical-align:middle; width:157px" %)((( 771 771 Effective immediately 772 772 )))|(% style="text-align:center; vertical-align:middle; width:121px" %)800|(% style="text-align:center; vertical-align:middle; width:116px" %)10 to 2000|(% style="width:462px" %)Set the vibration frequency when vibration occurs at the load end.|(% style="text-align:center; vertical-align:middle; width:115px" %)0.1HZ 773 -|=(% style="text-align: center; vertical-align: middle; width: 134px;" %)P4-14|(% style="text-align:center; vertical-align:middle; width:258px" %)Shutdown vibration detection amplitude|(% style="text-align:center; vertical-align:middle; width:127px" %)((( 785 +|=(% style="text-align: center; vertical-align: middle; width: 134px;" %)P4-14((( 786 +〇 787 +)))|(% style="text-align:center; vertical-align:middle; width:258px" %)Shutdown vibration detection amplitude|(% style="text-align:center; vertical-align:middle; width:127px" %)((( 774 774 Operation setting 775 775 )))|(% style="text-align:center; vertical-align:middle; width:157px" %)((( 776 776 Effective immediately 777 777 )))|(% style="text-align:center; vertical-align:middle; width:121px" %)100|(% style="text-align:center; vertical-align:middle; width:116px" %)0 to 1000|(% style="width:462px" %)When the vibration amplitude is greater than (P5-12*P4-14 detection amplitude ratio), the low-frequency vibration frequency can be recognized and updated to the U0-16 monitor quantity.|(% style="text-align:center; vertical-align:middle; width:115px" %)0.001 778 778 793 +〇 indicates that VD2L servo drive does not support this function code. 794 + 779 779 **Vibration frequency detection:** 780 780 781 781 * Users can measure vibration by measuring equipment such as laser displacement.