Changes for page 07 Adjustments
Last modified by Iris on 2025/07/24 11:03
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -121,12 +121,8 @@ 121 121 122 122 (% class="table-bordered" style="margin-right:auto" %) 123 123 (% class="warning" %)|(% style="text-align:center; vertical-align:middle" %)[[image:image-20220611152630-1.png]] 124 -|(% style="text-align:left; vertical-align:middle" %)((( 125 -Before adjusting the rigidity grade, set the appropriate load inertia ratio P03-01 correctly. 124 +|(% style="text-align:left; vertical-align:middle" %)Before adjusting the rigidity grade, set the appropriate load inertia ratio P03-01 correctly. 126 126 127 -**VD2L drive does not support automatic gain adjustment!** 128 -))) 129 - 130 130 The value range of the rigidity grade is between 0 and 31. Grade 0 corresponds to the weakest rigidity and minimum gain, and grade 31 corresponds to the strongest rigidity and maximum gain. According to different load types, the values in the table below are for reference. 131 131 132 132 (% class="table-bordered" %) ... ... @@ -168,11 +168,9 @@ 168 168 )))|(% style="text-align:center; vertical-align:middle; width:105px" %)((( 169 169 Effective immediately 170 170 )))|(% style="text-align:center; vertical-align:middle; width:87px" %)0|(% style="text-align:center; vertical-align:middle; width:83px" %)0 to 2|(% style="width:431px" %)((( 171 -0: Rigidity grade self-adjusting mode. Position loop gain, speed loop gain, speed loop integral time constant, torque filter parameter settings are automatically adjusted according to the rigidity grade setting. 172 - 173 -1: Manual setting; you need to manually set the position loop gain, speed loop gain, speed loop integral time constant, torque filter parameter setting 174 - 175 -2: Online automatic parameter self-adjusting mode (Not implemented yet) 167 +* 0: Rigidity grade self-adjusting mode. Position loop gain, speed loop gain, speed loop integral time constant, torque filter parameter settings are automatically adjusted according to the rigidity grade setting. 168 +* 1: Manual setting; you need to manually set the position loop gain, speed loop gain, speed loop integral time constant, torque filter parameter setting 169 +* 2: Online automatic parameter self-adjusting mode (Not implemented yet) 176 176 )))|(% style="text-align:center; vertical-align:middle" %)- 177 177 178 178 Table 7-4 Details of self-adjusting mode selection parameters ... ... @@ -219,7 +219,7 @@ 219 219 Operation setting 220 220 )))|(% style="text-align:center; vertical-align:middle; width:128px" %)((( 221 221 Effective immediately 222 -)))|(% style="text-align:center; vertical-align:middle; width:103px" %) 200|(% style="text-align:center; vertical-align:middle; width:107px" %)0 to 35000|(% style="width:321px" %)Set speed loop proportional gain to determine the responsiveness of speed loop.|(% style="text-align:center; vertical-align:middle" %)0.1Hz216 +)))|(% style="text-align:center; vertical-align:middle; width:103px" %)65|(% style="text-align:center; vertical-align:middle; width:107px" %)0 to 35000|(% style="width:321px" %)Set speed loop proportional gain to determine the responsiveness of speed loop.|(% style="text-align:center; vertical-align:middle" %)0.1Hz 223 223 |=(% style="text-align: center; vertical-align: middle; width: 120px;" %)P02-05|(% style="text-align:center; vertical-align:middle; width:163px" %)2nd speed loop gain|(% style="text-align:center; vertical-align:middle; width:122px" %)((( 224 224 Operation setting 225 225 )))|(% style="text-align:center; vertical-align:middle; width:128px" %)((( ... ... @@ -250,7 +250,7 @@ 250 250 Operation setting 251 251 )))|(% style="text-align:center; vertical-align:middle; width:112px" %)((( 252 252 Effective immediately 253 -)))|(% style="text-align:center; vertical-align:middle; width:109px" %) 210|(% style="text-align:center; vertical-align:middle; width:114px" %)100 to 65535|(% style="width:278px" %)Set the speed loop integral constant. The smaller the set value, the stronger the integral effect.|(% style="text-align:center; vertical-align:middle; width:78px" %)(((247 +)))|(% style="text-align:center; vertical-align:middle; width:109px" %)1000|(% style="text-align:center; vertical-align:middle; width:114px" %)100 to 65535|(% style="width:278px" %)Set the speed loop integral constant. The smaller the set value, the stronger the integral effect.|(% style="text-align:center; vertical-align:middle; width:78px" %)((( 254 254 0.1ms 255 255 ))) 256 256 |=(% style="text-align: center; vertical-align: middle; width: 98px;" %)P02-06|(% style="text-align:center; vertical-align:middle; width:173px" %)((( ... ... @@ -285,7 +285,7 @@ 285 285 Operation setting 286 286 )))|(% style="text-align:center; vertical-align:middle; width:114px" %)((( 287 287 Effective immediately 288 -)))|(% style="text-align:center; vertical-align:middle; width:79px" %) 232|(% style="text-align:center; vertical-align:middle; width:91px" %)0 to 6200|(% style="width:355px" %)Set position loop proportional gain to determine the responsiveness of position control system.|(% style="text-align:center; vertical-align:middle" %)0.1Hz282 +)))|(% style="text-align:center; vertical-align:middle; width:79px" %)400|(% style="text-align:center; vertical-align:middle; width:91px" %)0 to 6200|(% style="width:355px" %)Set position loop proportional gain to determine the responsiveness of position control system.|(% style="text-align:center; vertical-align:middle" %)0.1Hz 289 289 |=(% style="text-align: center; vertical-align: middle; width: 95px;" %)P02-04|(% style="text-align:center; vertical-align:middle; width:174px" %)2nd position loop gain|(% style="text-align:center; vertical-align:middle; width:120px" %)((( 290 290 Operation setting 291 291 )))|(% style="text-align:center; vertical-align:middle; width:114px" %)((( ... ... @@ -309,12 +309,12 @@ 309 309 **Setting method** 310 310 )))|=(% style="text-align: center; vertical-align: middle; width: 127px;" %)((( 311 311 **Effective time** 312 -)))|=(% style="text-align: center; vertical-align: middle; width: 79px;" %)**Default value**|=(% style="text-align: center; vertical-align: middle; width: 79px;" %)Range|=(% style="text-align: center; vertical-align: middle; width:371px;" %)**Definition**|=(% style="text-align: center; vertical-align: middle;" %)**Unit**306 +)))|=(% style="text-align: center; vertical-align: middle; width: 79px;" %)**Default value**|=(% style="text-align: center; vertical-align: middle; width: 371px;" %)**Definition**|=(% style="text-align: center; vertical-align: middle;" %)**Unit** 313 313 |=(% style="text-align: center; vertical-align: middle; width: 117px;" %)P04-04|(% style="text-align:center; vertical-align:middle; width:200px" %)Torque filter time constant|(% style="text-align:center; vertical-align:middle; width:120px" %)((( 314 314 Operation setting 315 315 )))|(% style="text-align:center; vertical-align:middle; width:127px" %)((( 316 316 Effective immediately 317 -)))|(% style="text-align:center; vertical-align:middle; width:79px" %) 80|(% style="text-align:center; vertical-align:middle; width:79px" %)10 to 2500|(% style="width:371px" %)This parameter is automatically set when “self-adjustment mode selection” is selected as 1 or 2|(% style="text-align:center; vertical-align:middle" %)0.01ms311 +)))|(% style="text-align:center; vertical-align:middle; width:79px" %)50|(% style="width:371px" %)This parameter is automatically set when “self-adjustment mode selection” is selected as 1 or 2|(% style="text-align:center; vertical-align:middle" %)0.01ms 318 318 319 319 Table 7-8 Details of torque filter time constant parameters 320 320 ... ... @@ -704,9 +704,8 @@ 704 704 )))|(% style="text-align:center; vertical-align:middle; width:121px" %)((( 705 705 Effective immediately 706 706 )))|(% style="text-align:center; vertical-align:middle; width:99px" %)100|(% style="text-align:center; vertical-align:middle; width:102px" %)0 to 100|(% style="width:362px" %)((( 707 -0: all truncated 708 - 709 -100: all passed 701 +1. 0: all truncated 702 +1. 100: all passed 710 710 )))|(% style="text-align:center; vertical-align:middle; width:96px" %)- 711 711 |=(% style="text-align: center; vertical-align: middle; width: 113px;" %)P04-07|(% style="text-align:center; vertical-align:middle; width:155px" %)1st notch filter width|(% style="text-align:center; vertical-align:middle; width:115px" %)((( 712 712 Operation setting ... ... @@ -713,13 +713,10 @@ 713 713 )))|(% style="text-align:center; vertical-align:middle; width:121px" %)((( 714 714 Effective immediately 715 715 )))|(% style="text-align:center; vertical-align:middle; width:99px" %)4|(% style="text-align:center; vertical-align:middle; width:102px" %)0 to 12|(% style="width:362px" %)((( 716 -0: 0.5 times the bandwidth 717 - 718 -4: 1 times the bandwidth 719 - 720 -8: 2 times the bandwidth 721 - 722 -12: 4 times the bandwidth 709 +1. 0: 0.5 times the bandwidth 710 +1. 4: 1 times the bandwidth 711 +1. 8: 2 times the bandwidth 712 +1. 12: 4 times the bandwidth 723 723 )))|(% style="text-align:center; vertical-align:middle; width:96px" %)- 724 724 |=(% style="text-align: center; vertical-align: middle; width: 113px;" %)P04-08|(% style="text-align:center; vertical-align:middle; width:155px" %)2nd notch filter frequency|(% style="text-align:center; vertical-align:middle; width:115px" %)((( 725 725 Operation setting ... ... @@ -731,9 +731,8 @@ 731 731 )))|(% style="text-align:center; vertical-align:middle; width:121px" %)((( 732 732 Effective immediately 733 733 )))|(% style="text-align:center; vertical-align:middle; width:99px" %)100|(% style="text-align:center; vertical-align:middle; width:102px" %)0 to 100|(% style="width:362px" %)((( 734 -0: all truncated 735 - 736 -100: all passed 724 +1. 0: all truncated 725 +1. 100: all passed 737 737 )))|(% style="text-align:center; vertical-align:middle; width:96px" %)- 738 738 |=(% style="text-align: center; vertical-align: middle; width: 113px;" %)P04-10|(% style="text-align:center; vertical-align:middle; width:155px" %)2nd notch filter width|(% style="text-align:center; vertical-align:middle; width:115px" %)((( 739 739 Operation setting ... ... @@ -740,13 +740,10 @@ 740 740 )))|(% style="text-align:center; vertical-align:middle; width:121px" %)((( 741 741 Effective immediately 742 742 )))|(% style="text-align:center; vertical-align:middle; width:99px" %)4|(% style="text-align:center; vertical-align:middle; width:102px" %)0 to 12|(% style="width:362px" %)((( 743 -0: 0.5 times the bandwidth 744 - 745 -4: 1 times the bandwidth 746 - 747 -8: 2 times the bandwidth 748 - 749 -12: 4 times the bandwidth 732 +1. 0: 0.5 times the bandwidth 733 +1. 4: 1 times the bandwidth 734 +1. 8: 2 times the bandwidth 735 +1. 12: 4 times the bandwidth 750 750 )))|(% style="text-align:center; vertical-align:middle; width:96px" %)- 751 751 752 752 Table 7-11 Notch filter function code parameters ... ... @@ -755,8 +755,6 @@ 755 755 756 756 Low-frequency vibration suppression is suitable for working conditions where the motor vibrates during deceleration and shutdown after the position command is sent, and the vibration amplitude gradually decreases. The use of the low-frequency vibration suppression function is effective in reducing the time to complete positioning due to vibration effects. 757 757 758 -**VD2L drive does not support low frequency vibrartion suppression.** 759 - 760 760 (% style="text-align:center" %) 761 761 ((( 762 762 (% class="wikigeneratedid img-thumbnail" style="display:inline-block" %) ... ... @@ -805,8 +805,6 @@ 805 805 806 806 Type A vibration suppression is suitable for durational vibration during motor operation or shutdown. Use Type A suppression to help reduce vibrations at specific frequencies that occur during motion (For the situation where the vibration continues to maintain and the vibration amplitude is almost constant after the command is completed.) As shown in Figure 7-14. 807 807 808 -**VD2L drive does not support type A vibration suppression.** 809 - 810 810 (% style="text-align:center" %) 811 811 ((( 812 812 (% class="wikigeneratedid img-thumbnail" style="display:inline-block" %)