Changes for page 07 Adjustments
Last modified by Iris on 2025/07/24 11:03
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -768,30 +768,22 @@ 768 768 )))|=(% style="text-align: center; vertical-align: middle; width: 157px;" %)((( 769 769 **Effective time** 770 770 )))|=(% style="text-align: center; vertical-align: middle; width: 121px;" %)**Default value**|=(% style="text-align: center; vertical-align: middle; width: 116px;" %)**Range**|=(% style="text-align: center; vertical-align: middle; width: 462px;" %)**Definition**|=(% style="text-align: center; vertical-align: middle; width: 115px;" %)**Unit** 771 -|=(% style="text-align: center; vertical-align: middle; width: 134px;" %)P4-11((( 772 -〇 773 -)))|(% style="text-align:center; vertical-align:middle; width:258px" %)Enable low-frequency vibration suppression function|(% style="text-align:center; vertical-align:middle; width:127px" %)((( 771 +|=(% style="text-align: center; vertical-align: middle; width: 134px;" %)P4-11|(% style="text-align:center; vertical-align:middle; width:258px" %)Enable low-frequency vibration suppression function|(% style="text-align:center; vertical-align:middle; width:127px" %)((( 774 774 Operation setting 775 775 )))|(% style="text-align:center; vertical-align:middle; width:157px" %)((( 776 776 Effective immediately 777 777 )))|(% style="text-align:center; vertical-align:middle; width:121px" %)0|(% style="text-align:center; vertical-align:middle; width:116px" %)0 to 1|(% style="width:462px" %)When the function code is set to 1, enable the low-frequency vibration suppression function.|(% style="width:115px" %) 778 -|=(% style="text-align: center; vertical-align: middle; width: 134px;" %)P4-12((( 779 -〇 780 -)))|(% style="text-align:center; vertical-align:middle; width:258px" %)Low-frequency vibration suppression frequency|(% style="text-align:center; vertical-align:middle; width:127px" %)((( 776 +|=(% style="text-align: center; vertical-align: middle; width: 134px;" %)P4-12|(% style="text-align:center; vertical-align:middle; width:258px" %)Low-frequency vibration suppression frequency|(% style="text-align:center; vertical-align:middle; width:127px" %)((( 781 781 Operation setting 782 782 )))|(% style="text-align:center; vertical-align:middle; width:157px" %)((( 783 783 Effective immediately 784 784 )))|(% style="text-align:center; vertical-align:middle; width:121px" %)800|(% style="text-align:center; vertical-align:middle; width:116px" %)10 to 2000|(% style="width:462px" %)Set the vibration frequency when vibration occurs at the load end.|(% style="text-align:center; vertical-align:middle; width:115px" %)0.1HZ 785 -|=(% style="text-align: center; vertical-align: middle; width: 134px;" %)P4-14((( 786 -〇 787 -)))|(% style="text-align:center; vertical-align:middle; width:258px" %)Shutdown vibration detection amplitude|(% style="text-align:center; vertical-align:middle; width:127px" %)((( 781 +|=(% style="text-align: center; vertical-align: middle; width: 134px;" %)P4-14|(% style="text-align:center; vertical-align:middle; width:258px" %)Shutdown vibration detection amplitude|(% style="text-align:center; vertical-align:middle; width:127px" %)((( 788 788 Operation setting 789 789 )))|(% style="text-align:center; vertical-align:middle; width:157px" %)((( 790 790 Effective immediately 791 791 )))|(% style="text-align:center; vertical-align:middle; width:121px" %)100|(% style="text-align:center; vertical-align:middle; width:116px" %)0 to 1000|(% style="width:462px" %)When the vibration amplitude is greater than (P5-12*P4-14 detection amplitude ratio), the low-frequency vibration frequency can be recognized and updated to the U0-16 monitor quantity.|(% style="text-align:center; vertical-align:middle; width:115px" %)0.001 792 792 793 -〇 indicates that VD2L servo drive does not support this function code. 794 - 795 795 **Vibration frequency detection:** 796 796 797 797 * Users can measure vibration by measuring equipment such as laser displacement.