Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Stone
1 +XWiki.Mora
Content
... ... @@ -272,13 +272,20 @@
272 272  Operation setting
273 273  )))|(% style="text-align:center; vertical-align:middle; width:165px" %)(((
274 274  Effective immediately
275 -)))|(% style="text-align:center; vertical-align:middle; width:109px" %)2|(% style="text-align:center; vertical-align:middle; width:85px" %)0 to 5|(% style="width:224px" %)(((
276 -* 0: 2400bps
277 -* 1: 4800bps
278 -* 2: 9600bps
279 -* 3: 19200bps
280 -* 4: 38400bps
281 -* 5: 57600bp
275 +)))|(% style="text-align:center; vertical-align:middle; width:109px" %)2|(% style="text-align:center; vertical-align:middle; width:85px" %)0 to 6|(% style="width:224px" %)(((
276 +0: 2400bps
277 +
278 +1: 4800bps
279 +
280 +2: 9600bps
281 +
282 +3: 19200bps
283 +
284 +4: 38400bps
285 +
286 +5: 57600bp
287 +
288 +6:115200bps
282 282  )))|(% style="text-align:center; vertical-align:middle; width:69px" %)-
283 283  |(% style="text-align:center; vertical-align:middle; width:121px" %)P12-03|(% style="text-align:center; vertical-align:middle; width:165px" %)Serial data format|(% style="text-align:center; vertical-align:middle; width:148px" %)(((
284 284  Operation setting
... ... @@ -285,10 +285,13 @@
285 285  )))|(% style="text-align:center; vertical-align:middle; width:165px" %)(((
286 286  Effective immediately
287 287  )))|(% style="text-align:center; vertical-align:middle; width:109px" %)0|(% style="text-align:center; vertical-align:middle; width:85px" %)0 to 3|(% style="width:224px" %)(((
288 -* 0: 1 stop bit, no parity
289 -* 1: 1 stop bit, odd parity
290 -* 2: 1 stop bit, even parity
291 -* 3: 2 stop bits, no parity
295 +0: 1 stop bit, no parity
296 +
297 +1: 1 stop bit, odd parity
298 +
299 +2: 1 stop bit, even parity
300 +
301 +3: 2 stop bits, no parity
292 292  )))|(% style="text-align:center; vertical-align:middle; width:69px" %)-
293 293  |(% style="text-align:center; vertical-align:middle; width:121px" %)P12-04|(% style="text-align:center; vertical-align:middle; width:165px" %)Modbus communication data is written into EEPROM|(% style="text-align:center; vertical-align:middle; width:148px" %)(((
294 294  Operation setting
... ... @@ -295,10 +295,24 @@
295 295  )))|(% style="text-align:center; vertical-align:middle; width:165px" %)(((
296 296  Effective immediately
297 297  )))|(% style="text-align:center; vertical-align:middle; width:109px" %)0|(% style="text-align:center; vertical-align:middle; width:85px" %)0 to 1|(% style="width:224px" %)(((
298 -* 0: Do not write to EEPROM, and do not store after power failure;
299 -* 1: Write to EEPROM, power-down storage.
308 +0: Do not write to EEPROM, and do not store after power failure;
309 +
310 +1: Write to EEPROM, power-down storage.
300 300  )))|(% style="text-align:center; vertical-align:middle; width:69px" %)-
312 +|P12-06|Modbus 32-bit variable big endian and little endian|(((
313 +Operation
301 301  
315 +setting
316 +)))|(((
317 +Effective
318 +
319 +immediately
320 +)))|0|0-1|(((
321 +0: Big-endian mode, the lower address stores the higher 16 bits of data, and the higher address stores the lower 16 bits of data
322 +
323 +1: Little-endian mode, the lower address stores the lower 16 bits of data, and the higher address stores the higher 16 bits of data
324 +)))|-
325 +
302 302  = **Modbus communication variable address and value** =
303 303  