Changes for page 08 Communication
Last modified by Iris on 2025/07/24 15:23
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -272,13 +272,20 @@ 272 272 Operation setting 273 273 )))|(% style="text-align:center; vertical-align:middle; width:165px" %)((( 274 274 Effective immediately 275 -)))|(% style="text-align:center; vertical-align:middle; width:109px" %)2|(% style="text-align:center; vertical-align:middle; width:85px" %)0 to 5|(% style="width:224px" %)((( 276 -* 0: 2400bps 277 -* 1: 4800bps 278 -* 2: 9600bps 279 -* 3: 19200bps 280 -* 4: 38400bps 281 -* 5: 57600bp 275 +)))|(% style="text-align:center; vertical-align:middle; width:109px" %)2|(% style="text-align:center; vertical-align:middle; width:85px" %)0 to 6|(% style="width:224px" %)((( 276 +0: 2400bps 277 + 278 +1: 4800bps 279 + 280 +2: 9600bps 281 + 282 +3: 19200bps 283 + 284 +4: 38400bps 285 + 286 +5: 57600bp 287 + 288 +6:115200bps 282 282 )))|(% style="text-align:center; vertical-align:middle; width:69px" %)- 283 283 |(% style="text-align:center; vertical-align:middle; width:121px" %)P12-03|(% style="text-align:center; vertical-align:middle; width:165px" %)Serial data format|(% style="text-align:center; vertical-align:middle; width:148px" %)((( 284 284 Operation setting ... ... @@ -285,10 +285,13 @@ 285 285 )))|(% style="text-align:center; vertical-align:middle; width:165px" %)((( 286 286 Effective immediately 287 287 )))|(% style="text-align:center; vertical-align:middle; width:109px" %)0|(% style="text-align:center; vertical-align:middle; width:85px" %)0 to 3|(% style="width:224px" %)((( 288 -* 0: 1 stop bit, no parity 289 -* 1: 1 stop bit, odd parity 290 -* 2: 1 stop bit, even parity 291 -* 3: 2 stop bits, no parity 295 +0: 1 stop bit, no parity 296 + 297 +1: 1 stop bit, odd parity 298 + 299 +2: 1 stop bit, even parity 300 + 301 +3: 2 stop bits, no parity 292 292 )))|(% style="text-align:center; vertical-align:middle; width:69px" %)- 293 293 |(% style="text-align:center; vertical-align:middle; width:121px" %)P12-04|(% style="text-align:center; vertical-align:middle; width:165px" %)Modbus communication data is written into EEPROM|(% style="text-align:center; vertical-align:middle; width:148px" %)((( 294 294 Operation setting ... ... @@ -295,8 +295,9 @@ 295 295 )))|(% style="text-align:center; vertical-align:middle; width:165px" %)((( 296 296 Effective immediately 297 297 )))|(% style="text-align:center; vertical-align:middle; width:109px" %)0|(% style="text-align:center; vertical-align:middle; width:85px" %)0 to 1|(% style="width:224px" %)((( 298 -* 0: Do not write to EEPROM, and do not store after power failure; 299 -* 1: Write to EEPROM, power-down storage. 308 +0: Do not write to EEPROM, and do not store after power failure; 309 + 310 +1: Write to EEPROM, power-down storage. 300 300 )))|(% style="text-align:center; vertical-align:middle; width:69px" %)- 301 301 |P12-06|Modbus 32-bit variable big endian and little endian|((( 302 302 Operation