Changes for page 08 Communication
Last modified by Iris on 2025/07/24 15:23
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -272,20 +272,13 @@ 272 272 Operation setting 273 273 )))|(% style="text-align:center; vertical-align:middle; width:165px" %)((( 274 274 Effective immediately 275 -)))|(% style="text-align:center; vertical-align:middle; width:109px" %)2|(% style="text-align:center; vertical-align:middle; width:85px" %)0 to 6|(% style="width:224px" %)((( 276 -0: 2400bps 277 - 278 -1: 4800bps 279 - 280 -2: 9600bps 281 - 282 -3: 19200bps 283 - 284 -4: 38400bps 285 - 286 -5: 57600bp 287 - 288 -6:115200bps 275 +)))|(% style="text-align:center; vertical-align:middle; width:109px" %)2|(% style="text-align:center; vertical-align:middle; width:85px" %)0 to 5|(% style="width:224px" %)((( 276 +* 0: 2400bps 277 +* 1: 4800bps 278 +* 2: 9600bps 279 +* 3: 19200bps 280 +* 4: 38400bps 281 +* 5: 57600bp 289 289 )))|(% style="text-align:center; vertical-align:middle; width:69px" %)- 290 290 |(% style="text-align:center; vertical-align:middle; width:121px" %)P12-03|(% style="text-align:center; vertical-align:middle; width:165px" %)Serial data format|(% style="text-align:center; vertical-align:middle; width:148px" %)((( 291 291 Operation setting ... ... @@ -292,13 +292,10 @@ 292 292 )))|(% style="text-align:center; vertical-align:middle; width:165px" %)((( 293 293 Effective immediately 294 294 )))|(% style="text-align:center; vertical-align:middle; width:109px" %)0|(% style="text-align:center; vertical-align:middle; width:85px" %)0 to 3|(% style="width:224px" %)((( 295 -0: 1 stop bit, no parity 296 - 297 -1: 1 stop bit, odd parity 298 - 299 -2: 1 stop bit, even parity 300 - 301 -3: 2 stop bits, no parity 288 +* 0: 1 stop bit, no parity 289 +* 1: 1 stop bit, odd parity 290 +* 2: 1 stop bit, even parity 291 +* 3: 2 stop bits, no parity 302 302 )))|(% style="text-align:center; vertical-align:middle; width:69px" %)- 303 303 |(% style="text-align:center; vertical-align:middle; width:121px" %)P12-04|(% style="text-align:center; vertical-align:middle; width:165px" %)Modbus communication data is written into EEPROM|(% style="text-align:center; vertical-align:middle; width:148px" %)((( 304 304 Operation setting ... ... @@ -305,24 +305,10 @@ 305 305 )))|(% style="text-align:center; vertical-align:middle; width:165px" %)((( 306 306 Effective immediately 307 307 )))|(% style="text-align:center; vertical-align:middle; width:109px" %)0|(% style="text-align:center; vertical-align:middle; width:85px" %)0 to 1|(% style="width:224px" %)((( 308 -0: Do not write to EEPROM, and do not store after power failure; 309 - 310 -1: Write to EEPROM, power-down storage. 298 +* 0: Do not write to EEPROM, and do not store after power failure; 299 +* 1: Write to EEPROM, power-down storage. 311 311 )))|(% style="text-align:center; vertical-align:middle; width:69px" %)- 312 -|P12-06|Modbus 32-bit variable big endian and little endian|((( 313 -Operation 314 314 315 -setting 316 -)))|((( 317 -Effective 318 - 319 -immediately 320 -)))|0|0-1|((( 321 -0: Big-endian mode, the lower address stores the higher 16 bits of data, and the higher address stores the lower 16 bits of data 322 - 323 -1: Little-endian mode, the lower address stores the lower 16 bits of data, and the higher address stores the higher 16 bits of data 324 -)))|- 325 - 326 326 = **Modbus communication variable address and value** = 327 327 328 328 == **Variable address** == ... ... @@ -356,7 +356,7 @@ 356 356 )))|=(% style="text-align: center; vertical-align: middle; width: 278px;" %)((( 357 357 **Modbus address (Decimal)** 358 358 )))|=(% style="text-align: center; vertical-align: middle; width: 192px;" %)**Category**|=(% style="text-align: center; vertical-align: middle; width: 142px;" %)**Name** 359 -|(% style="text-align:center; vertical-align:middle; width:162px" %)P0 0-01|(% style="text-align:center; vertical-align:middle; width:302px" %)0x0001|(% style="text-align:center; vertical-align:middle; width:278px" %)1|(% style="text-align:center; vertical-align:middle; width:192px" %)Basic settings|(% style="text-align:center; vertical-align:middle; width:142px" %)Control mode335 +|(% style="text-align:center; vertical-align:middle; width:162px" %)P0-1|(% style="text-align:center; vertical-align:middle; width:302px" %)0x0001|(% style="text-align:center; vertical-align:middle; width:278px" %)1|(% style="text-align:center; vertical-align:middle; width:192px" %)Basic settings|(% style="text-align:center; vertical-align:middle; width:142px" %)Control mode 360 360 361 361 For detailed parameter addresses, please refer to __[["11.1 Lists of parameters".>>https://docs.we-con.com.cn/bin/view/Servo/Manual/02%20VD2%20SA%20Series/11%20Appendix/#HListsofparameters]]__ 362 362