Changes for page 08 Communication

Last modified by Iris on 2025/07/24 15:23

From version 14.1
edited by Mora Zhou
on 2025/04/29 14:22
Change comment: There is no comment for this version
To version 12.1
edited by Mora Zhou
on 2024/07/17 14:19
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -272,20 +272,13 @@
272 272  Operation setting
273 273  )))|(% style="text-align:center; vertical-align:middle; width:165px" %)(((
274 274  Effective immediately
275 -)))|(% style="text-align:center; vertical-align:middle; width:109px" %)2|(% style="text-align:center; vertical-align:middle; width:85px" %)0 to 6|(% style="width:224px" %)(((
276 -0: 2400bps
277 -
278 -1: 4800bps
279 -
280 -2: 9600bps
281 -
282 -3: 19200bps
283 -
284 -4: 38400bps
285 -
286 -5: 57600bp
287 -
288 -6:115200bps
275 +)))|(% style="text-align:center; vertical-align:middle; width:109px" %)2|(% style="text-align:center; vertical-align:middle; width:85px" %)0 to 5|(% style="width:224px" %)(((
276 +* 0: 2400bps
277 +* 1: 4800bps
278 +* 2: 9600bps
279 +* 3: 19200bps
280 +* 4: 38400bps
281 +* 5: 57600bp
289 289  )))|(% style="text-align:center; vertical-align:middle; width:69px" %)-
290 290  |(% style="text-align:center; vertical-align:middle; width:121px" %)P12-03|(% style="text-align:center; vertical-align:middle; width:165px" %)Serial data format|(% style="text-align:center; vertical-align:middle; width:148px" %)(((
291 291  Operation setting
... ... @@ -292,13 +292,10 @@
292 292  )))|(% style="text-align:center; vertical-align:middle; width:165px" %)(((
293 293  Effective immediately
294 294  )))|(% style="text-align:center; vertical-align:middle; width:109px" %)0|(% style="text-align:center; vertical-align:middle; width:85px" %)0 to 3|(% style="width:224px" %)(((
295 -0: 1 stop bit, no parity
296 -
297 -1: 1 stop bit, odd parity
298 -
299 -2: 1 stop bit, even parity
300 -
301 -3: 2 stop bits, no parity
288 +* 0: 1 stop bit, no parity
289 +* 1: 1 stop bit, odd parity
290 +* 2: 1 stop bit, even parity
291 +* 3: 2 stop bits, no parity
302 302  )))|(% style="text-align:center; vertical-align:middle; width:69px" %)-
303 303  |(% style="text-align:center; vertical-align:middle; width:121px" %)P12-04|(% style="text-align:center; vertical-align:middle; width:165px" %)Modbus communication data is written into EEPROM|(% style="text-align:center; vertical-align:middle; width:148px" %)(((
304 304  Operation setting
... ... @@ -305,9 +305,8 @@
305 305  )))|(% style="text-align:center; vertical-align:middle; width:165px" %)(((
306 306  Effective immediately
307 307  )))|(% style="text-align:center; vertical-align:middle; width:109px" %)0|(% style="text-align:center; vertical-align:middle; width:85px" %)0 to 1|(% style="width:224px" %)(((
308 -0: Do not write to EEPROM, and do not store after power failure;
309 -
310 -1: Write to EEPROM, power-down storage.
298 +* 0: Do not write to EEPROM, and do not store after power failure;
299 +* 1: Write to EEPROM, power-down storage.
311 311  )))|(% style="text-align:center; vertical-align:middle; width:69px" %)-
312 312  |P12-06|Modbus 32-bit variable big endian and little endian|(((
313 313  Operation
... ... @@ -356,7 +356,7 @@
356 356  )))|=(% style="text-align: center; vertical-align: middle; width: 278px;" %)(((
357 357  **Modbus address (Decimal)**
358 358  )))|=(% style="text-align: center; vertical-align: middle; width: 192px;" %)**Category**|=(% style="text-align: center; vertical-align: middle; width: 142px;" %)**Name**
359 -|(% style="text-align:center; vertical-align:middle; width:162px" %)P00-01|(% style="text-align:center; vertical-align:middle; width:302px" %)0x0001|(% style="text-align:center; vertical-align:middle; width:278px" %)1|(% style="text-align:center; vertical-align:middle; width:192px" %)Basic settings|(% style="text-align:center; vertical-align:middle; width:142px" %)Control mode
348 +|(% style="text-align:center; vertical-align:middle; width:162px" %)P0-1|(% style="text-align:center; vertical-align:middle; width:302px" %)0x0001|(% style="text-align:center; vertical-align:middle; width:278px" %)1|(% style="text-align:center; vertical-align:middle; width:192px" %)Basic settings|(% style="text-align:center; vertical-align:middle; width:142px" %)Control mode
360 360  
361 361  For detailed parameter addresses, please refer to __[["11.1 Lists of parameters".>>https://docs.we-con.com.cn/bin/view/Servo/Manual/02%20VD2%20SA%20Series/11%20Appendix/#HListsofparameters]]__
362 362