Changes for page 08 Communication
Last modified by Iris on 2025/07/24 15:23
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Iris1 +XWiki.Mora - Content
-
... ... @@ -34,9 +34,7 @@ 34 34 35 35 (% class="table-bordered" %) 36 36 (% class="warning" %)|(% style="text-align:center; vertical-align:middle" %)[[image:image-20220611153144-2.png]] 37 -|((( 38 -The grounding wire cannot form a closed loop under no circumstances. 39 -))) 37 +|Under no circumstances can the grounding wire form a closed loop. 40 40 41 41 When wiring, consider the drive capability of the computer/PLC and the distance between the computer/PLC and the servo drive. If the drive capacity is insufficient, a repeater is needed. 42 42 ... ... @@ -274,20 +274,13 @@ 274 274 Operation setting 275 275 )))|(% style="text-align:center; vertical-align:middle; width:165px" %)((( 276 276 Effective immediately 277 -)))|(% style="text-align:center; vertical-align:middle; width:109px" %)2|(% style="text-align:center; vertical-align:middle; width:85px" %)0 to 6|(% style="width:224px" %)((( 278 -0: 2400bps 279 - 280 -1: 4800bps 281 - 282 -2: 9600bps 283 - 284 -3: 19200bps 285 - 286 -4: 38400bps 287 - 288 -5: 57600bp 289 - 290 -6:115200bps 275 +)))|(% style="text-align:center; vertical-align:middle; width:109px" %)2|(% style="text-align:center; vertical-align:middle; width:85px" %)0 to 5|(% style="width:224px" %)((( 276 +* 0: 2400bps 277 +* 1: 4800bps 278 +* 2: 9600bps 279 +* 3: 19200bps 280 +* 4: 38400bps 281 +* 5: 57600bp 291 291 )))|(% style="text-align:center; vertical-align:middle; width:69px" %)- 292 292 |(% style="text-align:center; vertical-align:middle; width:121px" %)P12-03|(% style="text-align:center; vertical-align:middle; width:165px" %)Serial data format|(% style="text-align:center; vertical-align:middle; width:148px" %)((( 293 293 Operation setting ... ... @@ -294,13 +294,10 @@ 294 294 )))|(% style="text-align:center; vertical-align:middle; width:165px" %)((( 295 295 Effective immediately 296 296 )))|(% style="text-align:center; vertical-align:middle; width:109px" %)0|(% style="text-align:center; vertical-align:middle; width:85px" %)0 to 3|(% style="width:224px" %)((( 297 -0: 1 stop bit, no parity 298 - 299 -1: 1 stop bit, odd parity 300 - 301 -2: 1 stop bit, even parity 302 - 303 -3: 2 stop bits, no parity 288 +* 0: 1 stop bit, no parity 289 +* 1: 1 stop bit, odd parity 290 +* 2: 1 stop bit, even parity 291 +* 3: 2 stop bits, no parity 304 304 )))|(% style="text-align:center; vertical-align:middle; width:69px" %)- 305 305 |(% style="text-align:center; vertical-align:middle; width:121px" %)P12-04|(% style="text-align:center; vertical-align:middle; width:165px" %)Modbus communication data is written into EEPROM|(% style="text-align:center; vertical-align:middle; width:148px" %)((( 306 306 Operation setting ... ... @@ -307,9 +307,8 @@ 307 307 )))|(% style="text-align:center; vertical-align:middle; width:165px" %)((( 308 308 Effective immediately 309 309 )))|(% style="text-align:center; vertical-align:middle; width:109px" %)0|(% style="text-align:center; vertical-align:middle; width:85px" %)0 to 1|(% style="width:224px" %)((( 310 -0: Do not write to EEPROM, and do not store after power failure; 311 - 312 -1: Write to EEPROM, power-down storage. 298 +* 0: Do not write to EEPROM, and do not store after power failure; 299 +* 1: Write to EEPROM, power-down storage. 313 313 )))|(% style="text-align:center; vertical-align:middle; width:69px" %)- 314 314 |P12-06|Modbus 32-bit variable big endian and little endian|((( 315 315 Operation ... ... @@ -358,7 +358,7 @@ 358 358 )))|=(% style="text-align: center; vertical-align: middle; width: 278px;" %)((( 359 359 **Modbus address (Decimal)** 360 360 )))|=(% style="text-align: center; vertical-align: middle; width: 192px;" %)**Category**|=(% style="text-align: center; vertical-align: middle; width: 142px;" %)**Name** 361 -|(% style="text-align:center; vertical-align:middle; width:162px" %)P0 0-01|(% style="text-align:center; vertical-align:middle; width:302px" %)0x0001|(% style="text-align:center; vertical-align:middle; width:278px" %)1|(% style="text-align:center; vertical-align:middle; width:192px" %)Basic settings|(% style="text-align:center; vertical-align:middle; width:142px" %)Control mode348 +|(% style="text-align:center; vertical-align:middle; width:162px" %)P0-1|(% style="text-align:center; vertical-align:middle; width:302px" %)0x0001|(% style="text-align:center; vertical-align:middle; width:278px" %)1|(% style="text-align:center; vertical-align:middle; width:192px" %)Basic settings|(% style="text-align:center; vertical-align:middle; width:142px" %)Control mode 362 362 363 363 For detailed parameter addresses, please refer to __[["11.1 Lists of parameters".>>https://docs.we-con.com.cn/bin/view/Servo/Manual/02%20VD2%20SA%20Series/11%20Appendix/#HListsofparameters]]__ 364 364