Changes for page 08 Communication

Last modified by Iris on 2025/07/24 15:23

From version 7.1
edited by Stone Wu
on 2022/08/30 09:52
Change comment: There is no comment for this version
To version 8.1
edited by Stone Wu
on 2022/08/30 09:53
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -11,7 +11,7 @@
11 11  
12 12  Figure 8-1 The position of RS485 communication port of VD2B drive
13 13  
14 -For the position of the RS485 communication port of other models, see __[[4.5 Communication signal wiring>>https://docs.we-con.com.cn/bin/view/Servo/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/04%20Wiring/#HCommunicationsignalwiring]]__.
14 +For the position of the RS485 communication port of other models, see __[[4.5 Communication signal wiring>>https://docs.we-con.com.cn/bin/view/Servo/Manual/02%20VD2%20SA%20Series/04%20Wiring/#HCommunicationsignalwiring]]__.
15 15  
16 16  The servo drive adopts RS485 half-duplex communication mode. The 485 bus should adopt the hand-in-hand structure instead of the star structure or the bifurcated structure. The star structure or bifurcation structure will produce reflected signals, which will affect the 485 communication.
17 17  
... ... @@ -202,7 +202,6 @@
202 202  |**high byte**|**low byte**|**high byte**|**low byte**
203 203  |01|06|01|0A|0B|B8|AF, 76
204 204  
205 -
206 206  **10 Function code write**
207 207  
208 208  P07-09 set the 1st segment position to 2000, and this variable corresponds to the Modbus address: 1801 (0x0709).