1 = **Group P00 Basic settings** =
2
3 (% class="table-bordered" %)
4 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**P00-01**|(% style="text-align:center; vertical-align:middle" %)**Parameter name**|(% style="text-align:center; vertical-align:middle" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
5 |(% style="text-align:center; vertical-align:middle" %)Control mode|(% style="text-align:center; vertical-align:middle" %)(((
6 Shutdown setting
7 )))|(% style="text-align:center; vertical-align:middle" %)Effective immediately|(% style="text-align:center; vertical-align:middle" %)1|(% style="text-align:center; vertical-align:middle" %)1 to 6|(% style="text-align:center; vertical-align:middle" %)Basic setting|(% style="text-align:center; vertical-align:middle" %)-
8 |(% colspan="8" %)(((
9 Used to set the control mode of servo drive
10
11 (% class="table-bordered" %)
12 |(% style="text-align:center; vertical-align:middle; width:121px" %)**Setting value**|(% style="text-align:center; vertical-align:middle; width:145px" %)**Control mode**|(% style="text-align:center; vertical-align:middle" %)**Remarks**
13 |(% style="text-align:center; vertical-align:middle; width:121px" %)1|(% style="text-align:center; vertical-align:middle; width:145px" %)Position control|For position control parameter setting, please refer to __[[6.2 Position control mode>>http://13.229.109.52:8080/wiki/servo/view/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/06%20Operation/#HPositioncontrolmode]]__
14 |(% style="text-align:center; vertical-align:middle; width:121px" %)2|(% style="text-align:center; vertical-align:middle; width:145px" %)Speed control|For speed control parameter setting, please refer to __[[6.3 Speed control mode>>http://13.229.109.52:8080/wiki/servo/view/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/06%20Operation/#HSpeedcontrolmode]]__
15 |(% style="text-align:center; vertical-align:middle; width:121px" %)3|(% style="text-align:center; vertical-align:middle; width:145px" %)Torque control|For torque control parameter setting, please refer to __[[6.4 Torque control mode>>http://13.229.109.52:8080/wiki/servo/view/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/06%20Operation/#HTorquecontrolmode]]__
16 |(% style="text-align:center; vertical-align:middle; width:121px" %)4|(% style="text-align:center; vertical-align:middle; width:145px" %)Position/speed mix control|A DI terminal of the servo drive needs to be assigned to function 17 (MixModeSel, mixed mode selection), and the DI terminal logic is determined to be valid.(((
17 (% class="table-bordered" %)
18 |(% style="text-align:center; vertical-align:middle; width:480px" %)**MixModeSel terminal logic**|(% style="text-align:center; vertical-align:middle; width:419px" %)**Control mode**
19 |(% style="text-align:center; vertical-align:middle; width:480px" %)Invalid|(% style="text-align:center; vertical-align:middle; width:419px" %)Position control
20 |(% style="text-align:center; vertical-align:middle; width:480px" %)Valid|(% style="text-align:center; vertical-align:middle; width:419px" %)Speed control
21 )))
22 |(% style="text-align:center; vertical-align:middle; width:121px" %)5|(% style="text-align:center; vertical-align:middle; width:145px" %)Position/torque mix control|A DI terminal of the servo drive needs to be assigned to function 17 (MixModeSel, mixed mode selection), and the DI terminal logic is determined to be valid.(((
23 (% class="table-bordered" %)
24 |(% style="text-align:center; vertical-align:middle; width:482px" %)**MixModeSel terminal logic**|(% style="text-align:center; vertical-align:middle; width:417px" %)**Control mode**
25 |(% style="text-align:center; vertical-align:middle; width:482px" %)Invalid|(% style="text-align:center; vertical-align:middle; width:417px" %)Position control
26 |(% style="text-align:center; vertical-align:middle; width:482px" %)Valid|(% style="text-align:center; vertical-align:middle; width:417px" %)Torque control
27 )))
28 |(% style="text-align:center; vertical-align:middle; width:121px" %)6|(% style="text-align:center; vertical-align:middle; width:145px" %)Speed/torque mix control|A DI terminal of the servo drive needs to be assigned to function 17 (MixModeSel, mixed mode selection), and the DI terminal logic is determined to be valid.(((
29 (% class="table-bordered" %)
30 |(% style="text-align:center; vertical-align:middle; width:482px" %)**MixModeSel terminal logic**|(% style="text-align:center; vertical-align:middle; width:417px" %)**Control mode**
31 |(% style="text-align:center; vertical-align:middle; width:482px" %)Invalid|(% style="text-align:center; vertical-align:middle; width:417px" %)Speed control
32 |(% style="text-align:center; vertical-align:middle; width:482px" %)Valid|(% style="text-align:center; vertical-align:middle; width:417px" %)Torque control
33 )))
34
35 When P00-01 is set to 4, 5 or, please refer to __[[6.5 Mixed control mode>>http://13.229.109.52:8080/wiki/servo/view/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/06%20Operation/#HMixedcontrolmode]]__.
36 )))
37
38 (% class="table-bordered" %)
39 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**P00-04**|(% style="text-align:center; vertical-align:middle" %)**Parameter name**|(% style="text-align:center; vertical-align:middle" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
40 |(% style="text-align:center; vertical-align:middle" %)Rotation direction|(% style="text-align:center; vertical-align:middle" %)(((
41 Shutdown setting
42 )))|(% style="text-align:center; vertical-align:middle" %)Effective immediately|(% style="text-align:center; vertical-align:middle" %)0|(% style="text-align:center; vertical-align:middle" %)0 to 1|(% style="text-align:center; vertical-align:middle" %)Basic setting|(% style="text-align:center; vertical-align:middle" %)-
43 |(% colspan="8" style="text-align:center; vertical-align:middle" %)(((
44 Set the forward rotation direction of the motor when looking at the motor axis.
45
46 (% class="table-bordered" %)
47 |(% style="text-align:center; vertical-align:middle" %)**Setting value**|(% style="text-align:center; vertical-align:middle" %)**Rotation direction**|(% style="text-align:center; vertical-align:middle" %)**Remarks**
48 |(% style="text-align:center; vertical-align:middle" %)1|(% style="text-align:center; vertical-align:middle" %)Take CW as forward direction|(% style="text-align:center; vertical-align:middle" %)When looking at the motor axis, the rotation direction of the motor is clockwise
49 |(% style="text-align:center; vertical-align:middle" %)2|(% style="text-align:center; vertical-align:middle" %)Take CCW as forward direction|(% style="text-align:center; vertical-align:middle" %)When looking at the motor axis, the rotation direction of the motor is anticlockwise
50
51 [[image:image-20220608155014-1.png]]
52 )))
53
54 (% class="table-bordered" %)
55 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**P00-05**|(% style="text-align:center; vertical-align:middle" %)**Parameter name**|(% style="text-align:center; vertical-align:middle" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
56 |(% style="text-align:center; vertical-align:middle" %)Servo OFF shutdown method|(% style="text-align:center; vertical-align:middle" %)(((
57 Shutdown setting
58 )))|(% style="text-align:center; vertical-align:middle" %)Effective immediately|(% style="text-align:center; vertical-align:middle" %)0|(% style="text-align:center; vertical-align:middle" %)0 to 1|(% style="text-align:center; vertical-align:middle" %)Basic setting|(% style="text-align:center; vertical-align:middle" %)-
59 |(% colspan="8" %)Set the forward rotation direction of the motor when looking at the motor axis.(((
60 (% class="table-bordered" %)
61 |(% style="text-align:center; vertical-align:middle" %)**Setting value**|(% style="text-align:center; vertical-align:middle" %)**Shutdown method**|(% style="text-align:center; vertical-align:middle" %)**Remarks**
62 |(% style="text-align:center; vertical-align:middle" %)1|(% style="text-align:center; vertical-align:middle" %)(((
63 Free shutdown.
64
65 The motor shaft remains free
66 )))|(% rowspan="2" %)(((
67 Please set reasonable shutdown according to the machinery and running requirement.
68
69 Please refer to __[[6.1.7 Servo shutdown>>http://13.229.109.52:8080/wiki/servo/view/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/06%20Operation/#HServoshutdown]]__
70 )))
71 |(% style="text-align:center; vertical-align:middle" %)2|(% style="text-align:center; vertical-align:middle" %)(((
72 Zero-speed shutdown.
73
74 The motor shaft remains free
75 )))
76 )))
77
78 (% class="table-bordered" %)
79 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**P00-09**|(% style="text-align:center; vertical-align:middle" %)**Parameter name**|(% style="text-align:center; vertical-align:middle" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
80 |(% style="text-align:center; vertical-align:middle" %)Braking resistor setting|(% style="text-align:center; vertical-align:middle" %)(((
81 Operation setting
82 )))|(% style="text-align:center; vertical-align:middle" %)Effective immediately|(% style="text-align:center; vertical-align:middle" %)0|(% style="text-align:center; vertical-align:middle" %)0 to 3|(% style="text-align:center; vertical-align:middle" %)Basic setting|(% style="text-align:center; vertical-align:middle" %)-
83 |(% colspan="8" %)(((
84 Used to set the way in which braking energy is absorbed and released.
85
86 (% class="table-bordered" %)
87 |(% style="text-align:center; vertical-align:middle" %)**Setting value**|(% style="text-align:center; vertical-align:middle" %)**Braking resistor setting**|(% style="text-align:center; vertical-align:middle" %)**Remarks**
88 |(% style="text-align:center; vertical-align:middle" %)0|Use built-in braking resistor|(% rowspan="4" %)Please refer to __[[6.1.5 Braking resistor>>http://13.229.109.52:8080/wiki/servo/view/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/06%20Operation/#HBrakingresistor]]__ to choose the right braking method
89 |(% style="text-align:center; vertical-align:middle" %)1|Use external braking resistor and natural cooling
90 |(% style="text-align:center; vertical-align:middle" %)2|Use external braking resistor and forced air cooling (not settable)
91 |(% style="text-align:center; vertical-align:middle" %)3|No braking resistors are used, and all are absorbed by capacitance
92
93 ✎**Note:  **VD2-010SA1G and VD2F-010SA1P drives has no built-in braking resistor by default, so the default value of P00-09 is 3 (No braking resistors are used, and all are absorbed by capacitance).
94 )))
95
96 (% class="table-bordered" %)
97 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**P00-10**|(% style="text-align:center; vertical-align:middle" %)**Parameter name**|(% style="text-align:center; vertical-align:middle" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
98 |(% style="text-align:center; vertical-align:middle" %)External braking resistor value|(% style="text-align:center; vertical-align:middle" %)(((
99 Operation setting
100 )))|(% style="text-align:center; vertical-align:middle" %)Effective immediately|(% style="text-align:center; vertical-align:middle" %)50|(% style="text-align:center; vertical-align:middle" %)0 to 65535|(% style="text-align:center; vertical-align:middle" %)Basic setting|(% style="text-align:center; vertical-align:middle" %)Ω
101 |(% colspan="8" %)(((
102 Used to set the power of external braking resistor of servo drive.
103
104 When the maximum braking energy calculated value is greater than the maximum braking energy absorbed by capacitor, and the braking power calculated value is greater than the built-in braking resistor power, use external braking resistor.
105
106 If the value of P00-10 is too large, Er.25 (too large braking resistor value) or Er.22 (main power supply is over voltage) will occur.
107
108 When using an external braking resistor, the short wiring between C and D must be disconnected, and the external braking resistor should wiring between P+ and D.
109
110 Please refer to __[[g>>http://13.229.109.52:8080/wiki/servo/view/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/02%20Product%20Information/#HThecompositionoftheservodrive]]'g'g'g'g'g'g'g'g'g'g'g'g'g'g'g'g'g'g__.
111 )))
112
113 (% class="table-bordered" %)
114 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**P00-11**|(% style="text-align:center; vertical-align:middle" %)**Parameter name**|(% style="text-align:center; vertical-align:middle" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
115 |(% style="text-align:center; vertical-align:middle" %)External braking resistor power|(% style="text-align:center; vertical-align:middle" %)(((
116 Operation setting
117 )))|(% style="text-align:center; vertical-align:middle" %)Effective immediately|(% style="text-align:center; vertical-align:middle" %)100|(% style="text-align:center; vertical-align:middle" %)0 to 65535|(% style="text-align:center; vertical-align:middle" %)Basic setting|(% style="text-align:center; vertical-align:middle" %)W
118 |(% colspan="8" %)Used to set resistor value of external braking resistor of servo drive. The power of external braking resistor (P00-11) can not less than the braking resistance power calculation value.
119
120 (% class="table-bordered" %)
121 |(% rowspan="2" style="text-align:center; vertical-align:middle; width:85px" %)**P00-12**|(% style="text-align:center; vertical-align:middle; width:306px" %)**Parameter name**|(% style="text-align:center; vertical-align:middle; width:181px" %)**Setting method**|(% style="text-align:center; vertical-align:middle; width:216px" %)**Effective time**|(% style="text-align:center; vertical-align:middle; width:91px" %)**Default**|(% style="text-align:center; vertical-align:middle; width:122px" %)**Range**|(% style="text-align:center; vertical-align:middle; width:136px" %)**Category**|(% style="text-align:center; vertical-align:middle; width:64px" %)**Unit**
122 |(% style="text-align:center; vertical-align:middle; width:306px" %)(((
123 Position pulse type selection
124 )))|(% style="text-align:center; vertical-align:middle; width:181px" %)(((
125 Operation setting
126 )))|(% style="text-align:center; vertical-align:middle; width:216px" %)(((
127 Power-on again
128 )))|(% style="text-align:center; vertical-align:middle; width:91px" %)0|(% style="text-align:center; vertical-align:middle; width:122px" %)0 to 5|(% style="text-align:center; vertical-align:middle; width:136px" %)(((
129 Position mode
130 )))|(% style="text-align:center; vertical-align:middle; width:64px" %)-
131 |(% colspan="8" %)In position control mode, when position instruction source is pulse instruction (P01-06=0) , input pulse pattern.(((
132 (% class="table-bordered" %)
133 |(% style="text-align:center; vertical-align:middle" %)**Setting value**|(% style="text-align:center; vertical-align:middle" %)**Pulse pattern**|(% style="text-align:center; vertical-align:middle" %)**Remarks**
134 |(% style="text-align:center; vertical-align:middle" %)0|Direction + pulse(positive logic)|(% rowspan="6" %)Please refer to __[[Table 6-15>>http://13.229.109.52:8080/wiki/servo/view/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/06%20Operation/#HPositioninstructioninputsetting]]__ in __[[6.2.1 Position instruction input setting>>http://13.229.109.52:8080/wiki/servo/view/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/06%20Operation/#HPositioninstructioninputsetting]]__
135 |(% style="text-align:center; vertical-align:middle" %)1|CW/CCW
136 |(% style="text-align:center; vertical-align:middle" %)2|AB phase orthogonal pulse (4 times frequency)
137 |(% style="text-align:center; vertical-align:middle" %)3|Direction + pulse (negative logic)
138 |(% style="text-align:center; vertical-align:middle" %)4|CW/CCW (negative logic)
139 |(% style="text-align:center; vertical-align:middle" %)5|AB phase orthogonal pulse (4 times frequency negative logic)
140 )))
141
142 (% class="table-bordered" %)
143 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**P00-13**|(% style="text-align:center; vertical-align:middle" %)**Parameter name**|(% style="text-align:center; vertical-align:middle" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
144 |(% style="text-align:center; vertical-align:middle" %)Maximum position pulse frequency|(% style="text-align:center; vertical-align:middle" %)(((
145 Shutdown setting
146 )))|(% style="text-align:center; vertical-align:middle" %)Effective immediately|(% style="text-align:center; vertical-align:middle" %)300|(% style="text-align:center; vertical-align:middle" %)1 to 500|(% style="text-align:center; vertical-align:middle" %)(((
147 Position mode
148 )))|(% style="text-align:center; vertical-align:middle" %)KHz
149 |(% colspan="8" %)In position control mode, when position instruction source is pulse instruction (P01-06=0) , input the maximum frequency of pulse When the actual pulse input frequency is greater than the setting value of P00-13, A-86 would occurs (The input pulse frequency is too high).
150
151 (% class="table-bordered" %)
152 |(% rowspan="2" style="text-align:center; vertical-align:middle; width:279px" %)**P00-14**|(% style="text-align:center; vertical-align:middle; width:407px" %)**Parameter name**|(% style="text-align:center; vertical-align:middle; width:178px" %)**Setting method**|(% style="text-align:center; vertical-align:middle; width:208px" %)**Effective time**|(% style="text-align:center; vertical-align:middle; width:92px" %)**Default**|(% style="text-align:center; vertical-align:middle; width:101px" %)**Range**|(% style="text-align:center; vertical-align:middle; width:148px" %)**Category**|(% style="text-align:center; vertical-align:middle; width:58px" %)**Unit**
153 |(% style="text-align:center; vertical-align:middle; width:407px" %)(((
154 Position pulse anti-interference level
155 )))|(% style="text-align:center; vertical-align:middle; width:178px" %)(((
156 Operation setting
157 )))|(% style="text-align:center; vertical-align:middle; width:208px" %)(((
158 Power-on again
159 )))|(% style="text-align:center; vertical-align:middle; width:92px" %)2|(% style="text-align:center; vertical-align:middle; width:101px" %)0 to 9|(% style="text-align:center; vertical-align:middle; width:148px" %)(((
160 Position mode
161 )))|(% style="text-align:center; vertical-align:middle; width:58px" %)-
162 |(% colspan="8" %)In position control mode, filter the input pulse. The larger the P00-14 setting value, the greater the filter depth.(((
163 (% class="table-bordered" %)
164 |(% style="text-align:center; vertical-align:middle" %)**Setting value**|(% style="text-align:center; vertical-align:middle" %)**Filtering time**|(% style="text-align:center; vertical-align:middle" %)**Setting value**|(% style="text-align:center; vertical-align:middle" %)**Filtering time**
165 |(% style="text-align:center; vertical-align:middle" %)0|(% style="text-align:center; vertical-align:middle" %)No filtering|(% style="text-align:center; vertical-align:middle" %)5|(% style="text-align:center; vertical-align:middle" %)2.048us
166 |(% style="text-align:center; vertical-align:middle" %)1|(% style="text-align:center; vertical-align:middle" %)128ns|(% style="text-align:center; vertical-align:middle" %)6|(% style="text-align:center; vertical-align:middle" %)4.096 us
167 |(% style="text-align:center; vertical-align:middle" %)2|(% style="text-align:center; vertical-align:middle" %)256ns|(% style="text-align:center; vertical-align:middle" %)7|(% style="text-align:center; vertical-align:middle" %)8.192 us
168 |(% style="text-align:center; vertical-align:middle" %)3|(% style="text-align:center; vertical-align:middle" %)512ns|(% style="text-align:center; vertical-align:middle" %)8|(% style="text-align:center; vertical-align:middle" %)16.384 us
169 |(% style="text-align:center; vertical-align:middle" %)4|(% style="text-align:center; vertical-align:middle" %)1.024us|(% style="text-align:center; vertical-align:middle" %)9|(% style="text-align:center; vertical-align:middle" %)VD2: 32.768us. VD2F: 25.5us
170 )))
171
172 (% class="table-bordered" %)
173 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**P00-16**|(% style="text-align:center; vertical-align:middle; width:338px" %)**Parameter name**|(% style="text-align:center; vertical-align:middle; width:186px" %)**Setting method**|(% style="text-align:center; vertical-align:middle; width:207px" %)**Effective time**|(% style="text-align:center; vertical-align:middle; width:96px" %)**Default**|(% style="text-align:center; vertical-align:middle; width:101px" %)**Range**|(% style="text-align:center; vertical-align:middle; width:147px" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
174 |(% style="text-align:center; vertical-align:middle; width:338px" %)Number of instruction pulses per turn of motor|(% style="text-align:center; vertical-align:middle; width:186px" %)(((
175 Shutdown setting
176 )))|(% style="text-align:center; vertical-align:middle; width:207px" %)Effective immediately|(% style="text-align:center; vertical-align:middle; width:96px" %)10000|(% style="text-align:center; vertical-align:middle; width:101px" %)0 to 131072|(% style="text-align:center; vertical-align:middle; width:147px" %)(((
177 Position mode
178 )))|(% style="text-align:center; vertical-align:middle" %)W
179 |(% colspan="8" %)Used to set the number of instruction pulses required for per turn of motor
180
181 (% class="table-bordered" %)
182 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**P00-17**|(% style="text-align:center; vertical-align:middle; width:266px" %)**Parameter name**|(% style="text-align:center; vertical-align:middle; width:196px" %)**Setting method**|(% style="text-align:center; vertical-align:middle; width:248px" %)**Effective time**|(% style="text-align:center; vertical-align:middle; width:82px" %)**Default**|(% style="text-align:center; vertical-align:middle; width:145px" %)**Range**|(% style="text-align:center; vertical-align:middle; width:115px" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
183 |(% style="text-align:center; vertical-align:middle; width:266px" %)(((
184 Electronic gear 1 numerator
185 )))|(% style="text-align:center; vertical-align:middle; width:196px" %)(((
186 Operationsetting
187 )))|(% style="text-align:center; vertical-align:middle; width:248px" %)Effective immediately|(% style="text-align:center; vertical-align:middle; width:82px" %)1|(% style="text-align:center; vertical-align:middle; width:145px" %)0 to 4294967294|(% style="text-align:center; vertical-align:middle; width:115px" %)(((
188 Position mode
189 )))|(% style="text-align:center; vertical-align:middle" %)W
190 |(% colspan="8" %)Used to set the numerator of the first group electronic gear for position instruction. This function code is only valid when P00-16=0.
191
192 (% class="table-bordered" %)
193 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**P00-18**|(% style="text-align:center; vertical-align:middle; width:266px" %)**Parameter name**|(% style="text-align:center; vertical-align:middle; width:199px" %)**Setting method**|(% style="text-align:center; vertical-align:middle; width:247px" %)**Effective time**|(% style="text-align:center; vertical-align:middle; width:88px" %)**Default**|(% style="text-align:center; vertical-align:middle; width:136px" %)**Range**|(% style="text-align:center; vertical-align:middle; width:121px" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
194 |(% style="text-align:center; vertical-align:middle; width:266px" %)(((
195 Electronic gear 1 denominator
196 )))|(% style="text-align:center; vertical-align:middle; width:199px" %)(((
197 Operation setting
198 )))|(% style="text-align:center; vertical-align:middle; width:247px" %)Effective immediately|(% style="text-align:center; vertical-align:middle; width:88px" %)1|(% style="text-align:center; vertical-align:middle; width:136px" %)0 to 4294967294|(% style="text-align:center; vertical-align:middle; width:121px" %)(((
199 Position mode
200 )))|(% style="text-align:center; vertical-align:middle" %)W
201 |(% colspan="8" %)Used to set the numerator of the first group electronic gear for position instruction. This function code is only valid when P00-16=0.
202
203 (% class="table-bordered" %)
204 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**P00-19**|(% style="text-align:center; vertical-align:middle; width:268px" %)**Parameter name**|(% style="text-align:center; vertical-align:middle; width:198px" %)**Setting method**|(% style="text-align:center; vertical-align:middle; width:245px" %)**Effective time**|(% style="text-align:center; vertical-align:middle; width:95px" %)**Default**|(% style="text-align:center; vertical-align:middle; width:133px" %)**Range**|(% style="text-align:center; vertical-align:middle; width:123px" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
205 |(% style="text-align:center; vertical-align:middle; width:268px" %)(((
206 Electronic gear 2 numerator
207 )))|(% style="text-align:center; vertical-align:middle; width:198px" %)(((
208 Operation setting
209 )))|(% style="text-align:center; vertical-align:middle; width:245px" %)Effective immediately|(% style="text-align:center; vertical-align:middle; width:95px" %)1|(% style="text-align:center; vertical-align:middle; width:133px" %)0 to 4294967294|(% style="text-align:center; vertical-align:middle; width:123px" %)(((
210 Position mode
211 )))|(% style="text-align:center; vertical-align:middle" %)W
212 |(% colspan="8" %)Used to set the numerator of the second group electronic gear for position instruction. This function code is only valid when P00-16=0.
213
214 (% class="table-bordered" %)
215 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**P00-20**|(% style="text-align:center; vertical-align:middle; width:261px" %)**Parameter name**|(% style="text-align:center; vertical-align:middle; width:208px" %)**Setting method**|(% style="text-align:center; vertical-align:middle; width:246px" %)**Effective time**|(% style="text-align:center; vertical-align:middle; width:99px" %)**Default**|(% style="text-align:center; vertical-align:middle; width:132px" %)**Range**|(% style="text-align:center; vertical-align:middle; width:120px" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
216 |(% style="text-align:center; vertical-align:middle; width:261px" %)(((
217 Electronic gear 2 denominator
218 )))|(% style="text-align:center; vertical-align:middle; width:208px" %)(((
219 Operation setting
220 )))|(% style="text-align:center; vertical-align:middle; width:246px" %)Effective immediately|(% style="text-align:center; vertical-align:middle; width:99px" %)1|(% style="text-align:center; vertical-align:middle; width:132px" %)0 to 4294967294|(% style="text-align:center; vertical-align:middle; width:120px" %)(((
221 Position mode
222 )))|(% style="text-align:center; vertical-align:middle" %)W
223 |(% colspan="8" %)Used to set the numerator of the second group electronic gear for position instruction. This function code is only valid when P00-16=0.
224
225 (% class="table-bordered" %)
226 |(% rowspan="2" style="text-align:center; vertical-align:middle; width:79px" %)(((
227 **P00-21**
228
229
230 )))|(% style="text-align:center; vertical-align:middle; width:290px" %)**Parameter name**|(% style="text-align:center; vertical-align:middle; width:193px" %)**Setting method**|(% style="text-align:center; vertical-align:middle; width:235px" %)**Effective time**|(% style="text-align:center; vertical-align:middle; width:174px" %)**Default**|(% style="text-align:center; vertical-align:middle; width:202px" %)**Range**|(% style="text-align:center; vertical-align:middle; width:166px" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
231 |(% style="text-align:center; vertical-align:middle; width:290px" %)Pulse frequency division output direction|(% style="text-align:center; vertical-align:middle; width:193px" %)(((
232 Operation setting
233 )))|(% style="text-align:center; vertical-align:middle; width:235px" %)(((
234 Power-on again
235 )))|(% style="text-align:center; vertical-align:middle; width:174px" %)2|(% style="text-align:center; vertical-align:middle; width:202px" %)0 to 1|(% style="text-align:center; vertical-align:middle; width:166px" %)(((
236 Position mode
237 )))|(% style="text-align:center; vertical-align:middle" %)-
238 |(% colspan="8" %)Used to set the pulse frequency division output direction(((
239 (% class="table-bordered" %)
240 |(% style="text-align:center; vertical-align:middle" %)**Setting value**|(% style="text-align:center; vertical-align:middle" %)**Output direction**
241 |(% style="text-align:center; vertical-align:middle" %)0|(% style="text-align:center; vertical-align:middle" %)CW is forward direction (A is ahead of B)
242 |(% style="text-align:center; vertical-align:middle" %)1|(% style="text-align:center; vertical-align:middle" %)CCW is forward direction (A is ahead of B)
243 )))
244
245 “☆” indicates that the VD2F servo drive does not support this function code.
246
247 (% class="table-bordered" %)
248 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)(((
249 **P00-22**
250
251
252 )))|(% style="text-align:center; vertical-align:middle; width:331px" %)**Parameter name**|(% style="text-align:center; vertical-align:middle; width:211px" %)**Setting method**|(% style="text-align:center; vertical-align:middle; width:176px" %)**Effective time**|(% style="text-align:center; vertical-align:middle; width:100px" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
253 |(% style="text-align:center; vertical-align:middle; width:331px" %)The number of output pulses per turn of motor|(% style="text-align:center; vertical-align:middle; width:211px" %)(((
254 Operation setting
255 )))|(% style="text-align:center; vertical-align:middle; width:176px" %)(((
256 Power-on again
257 )))|(% style="text-align:center; vertical-align:middle; width:100px" %)2500|(% style="text-align:center; vertical-align:middle" %)0 to 2500|(% style="text-align:center; vertical-align:middle" %)(((
258 Position mode
259 )))|(% style="text-align:center; vertical-align:middle" %)-
260 |(% colspan="8" %)✎**Note:** Each rotation of the motor, phase A and phase B can each output up to 2500 pulses, and the control device receiver device needs to support 4 times frequency analysis to get 10000 pulses.
261
262 “☆” indicates that the VD2F servo drive does not support this function code.
263
264 (% class="table-bordered" %)
265 |(% rowspan="2" style="text-align:center; vertical-align:middle; width:72px" %)(((
266 **P00-23**
267
268
269 )))|(% style="text-align:center; vertical-align:middle; width:230px" %)**Parameter name**|(% style="text-align:center; vertical-align:middle; width:201px" %)**Setting method**|(% style="text-align:center; vertical-align:middle; width:171px" %)**Effective time**|(% style="text-align:center; vertical-align:middle; width:127px" %)**Default**|(% style="text-align:center; vertical-align:middle; width:158px" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
270 |(% style="text-align:center; vertical-align:middle; width:230px" %)Z pulse output OZ polarity|(% style="text-align:center; vertical-align:middle; width:201px" %)(((
271 Operation setting
272 )))|(% style="text-align:center; vertical-align:middle; width:171px" %)(((
273 Power-on again
274 )))|(% style="text-align:center; vertical-align:middle; width:127px" %)2|(% style="text-align:center; vertical-align:middle; width:158px" %)0 to 1|(% style="text-align:center; vertical-align:middle" %)Position mode|(% style="text-align:center; vertical-align:middle" %)-
275 |(% colspan="8" %)Used to set the level logic of Z pulse(((
276 (% class="table-bordered" %)
277 |(% style="text-align:center; vertical-align:middle" %)**Setting value**|(% style="text-align:center; vertical-align:middle" %)**Output direction**
278 |(% style="text-align:center; vertical-align:middle" %)0|(% style="text-align:center; vertical-align:middle" %)Active high level
279 |(% style="text-align:center; vertical-align:middle" %)1|(% style="text-align:center; vertical-align:middle" %)Active low level
280 )))
281
282 (% class="table-bordered" %)
283 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**P00-25**|(% style="text-align:center; vertical-align:middle" %)**Parameter name**|(% style="text-align:center; vertical-align:middle; width:169px" %)**Setting method**|(% style="text-align:center; vertical-align:middle; width:185px" %)**Effective time**|(% style="text-align:center; vertical-align:middle; width:105px" %)**Default**|(% style="text-align:center; vertical-align:middle; width:154px" %)**Range**|(% style="text-align:center; vertical-align:middle; width:115px" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
284 |(% style="text-align:center; vertical-align:middle" %)Position deviation limit|(% style="text-align:center; vertical-align:middle; width:169px" %)Shutdown setting|(% style="text-align:center; vertical-align:middle; width:185px" %)Effective immediately|(% style="text-align:center; vertical-align:middle; width:105px" %)60000|(% style="text-align:center; vertical-align:middle; width:154px" %)0 to 2147483646|(% style="text-align:center; vertical-align:middle; width:115px" %)(((
285 Position mode
286 )))|(% style="text-align:center; vertical-align:middle" %)Equivalent pulse unit
287 |(% colspan="8" %)(((
288 Used to set position deviation limit value. When the actual deviation of motor exceeds the setting value of this function code, Er.36 would occurs (position deviation is too large).
289
290 When the function code is set to 0, positional bias is ignored.
291 )))
292
293 (% class="table-bordered" %)
294 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)(((
295 **P00-27**
296
297
298 )))|(% style="text-align:center; vertical-align:middle; width:329px" %)**Parameter name**|(% style="text-align:center; vertical-align:middle; width:196px" %)**Setting method**|(% style="text-align:center; vertical-align:middle; width:161px" %)**Effective time**|(% style="text-align:center; vertical-align:middle; width:121px" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
299 |(% style="text-align:center; vertical-align:middle; width:329px" %)Pulse output frequency division numerator|(% style="text-align:center; vertical-align:middle; width:196px" %)(((
300 Operation setting
301 )))|(% style="text-align:center; vertical-align:middle; width:161px" %)(((
302 Power-on again
303 )))|(% style="text-align:center; vertical-align:middle; width:121px" %)1|(% style="text-align:center; vertical-align:middle" %)1 to 2500|(% style="text-align:center; vertical-align:middle" %)Position mode|(% style="text-align:center; vertical-align:middle" %)-
304 |(% colspan="8" %)Orthogonal coded output (numerator/denominator format). Used to set pulse output frequency division numerator. (When P00-22=0, and the pulse output frequency division numerator value is less than the pulse output frequency division denominator value, this function code is valid)
305
306 “☆” indicates that the VD2F servo drive does not support this function code.
307
308 (% class="table-bordered" %)
309 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)(((
310 **P00-28**
311
312
313 )))|(% style="text-align:center; vertical-align:middle; width:332px" %)**Parameter name**|(% style="text-align:center; vertical-align:middle; width:194px" %)**Setting method**|(% style="text-align:center; vertical-align:middle; width:162px" %)**Effective time**|(% style="text-align:center; vertical-align:middle; width:123px" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
314 |(% style="text-align:center; vertical-align:middle; width:332px" %)Pulse output frequency division denominator|(% style="text-align:center; vertical-align:middle; width:194px" %)(((
315 Operation setting
316 )))|(% style="text-align:center; vertical-align:middle; width:162px" %)(((
317 Power-on again
318 )))|(% style="text-align:center; vertical-align:middle; width:123px" %)1|(% style="text-align:center; vertical-align:middle" %)1 to 2500|(% style="text-align:center; vertical-align:middle" %)Position mode|(% style="text-align:center; vertical-align:middle" %)-
319 |(% colspan="8" %)Orthogonal coded output (numerator/denominator format). Used to set pulse output frequency division denominator. (When P00-22=0, and the pulse output frequency division denominator value is greater than the pulse output frequency division numerator value, this function code is valid)
320
321 “☆” indicates that the VD2F servo drive does not support this function code.
322
323 (% class="table-bordered" %)
324 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**P00-29**|(% style="text-align:center; vertical-align:middle; width:369px" %)**Parameter name**|(% style="text-align:center; vertical-align:middle; width:170px" %)**Setting method**|(% style="text-align:center; vertical-align:middle; width:169px" %)**Effective time**|(% style="text-align:center; vertical-align:middle; width:110px" %)**Default**|(% style="text-align:center; vertical-align:middle; width:124px" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
325 |(% style="text-align:center; vertical-align:middle; width:369px" %)The number of equivalent position units in one circle|(% style="text-align:center; vertical-align:middle; width:170px" %)Shutdown setting|(% style="text-align:center; vertical-align:middle; width:169px" %)Effective immediately|(% style="text-align:center; vertical-align:middle; width:110px" %)10000|(% style="text-align:center; vertical-align:middle; width:124px" %)0 to 131072|(% style="text-align:center; vertical-align:middle" %)Position mode|(% style="text-align:center; vertical-align:middle" %)-
326 |(% colspan="8" %)The equivalent position unit of one circle of the motor
327
328 (% class="table-bordered" %)
329 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**P00-30**|(% style="text-align:center; vertical-align:middle; width:367px" %)**Parameter name**|(% style="text-align:center; vertical-align:middle; width:173px" %)**Setting method**|(% style="text-align:center; vertical-align:middle; width:170px" %)**Effective time**|(% style="text-align:center; vertical-align:middle; width:111px" %)**Default**|(% style="text-align:center; vertical-align:middle; width:112px" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
330 |(% style="text-align:center; vertical-align:middle; width:367px" %)Shielded multi-turn absolute encoder battery failure|(% style="text-align:center; vertical-align:middle; width:173px" %)(((
331 Operation setting
332 )))|(% style="text-align:center; vertical-align:middle; width:170px" %)(((
333 Power-on again
334 )))|(% style="text-align:center; vertical-align:middle; width:111px" %)2|(% style="text-align:center; vertical-align:middle; width:112px" %)0 to 1|(% style="text-align:center; vertical-align:middle" %)Basic setting|(% style="text-align:center; vertical-align:middle" %)-
335 |(% colspan="8" %)Used to set multi-turn absolute encoder battery fault alarm setting function. (VD2-SA V1.13 firmware added)(((
336 (% class="table-bordered" %)
337 |(% style="text-align:center; vertical-align:middle" %)**Setting value**|(% style="text-align:center; vertical-align:middle" %)**Function**|(% style="text-align:center; vertical-align:middle" %)**Remarks**
338 |(% style="text-align:center; vertical-align:middle" %)0|(% style="text-align:center; vertical-align:middle" %)Shield|Detect multi-turn absolute encoder battery under voltage and battery low-voltage fault. Please refer to __[[6.6 Absolute system>>http://13.229.109.52:8080/wiki/servo/view/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/06%20Operation/#HAbsolutesystem]]__.
339 |(% style="text-align:center; vertical-align:middle" %)1|(% style="text-align:center; vertical-align:middle" %)Not shield|Shield multi-turn absolute encoder battery under voltage and battery low-voltage fault.This would cause mechanical failure, please use with caution.
340 )))
341
342 = **Group P01 Control parameters** =
343
344 (% class="table-bordered" %)
345 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**P01-01**|(% style="text-align:center; vertical-align:middle" %)**Parameter name**|(% style="text-align:center; vertical-align:middle" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
346 |(% style="text-align:center; vertical-align:middle" %)Speed instruction source|(% style="text-align:center; vertical-align:middle" %)Shutdown setting|(% style="text-align:center; vertical-align:middle" %)Power-on again|(% style="text-align:center; vertical-align:middle" %)0|(% style="text-align:center; vertical-align:middle" %)0 to 1|(% style="text-align:center; vertical-align:middle" %)Speed mode|(% style="text-align:center; vertical-align:middle" %)-
347 |(% colspan="8" %)(((
348 Select speed instruction source
349
350 (% class="table-bordered" %)
351 |(% style="text-align:center; vertical-align:middle" %)**Setting value**|(% style="text-align:center; vertical-align:middle" %)**Function**|(% style="text-align:center; vertical-align:middle" %)**Remarks**
352 |(% style="text-align:center; vertical-align:middle" %)0|(% style="text-align:center; vertical-align:middle" %)Internal speed instruction|(% style="text-align:center; vertical-align:middle" %)Please refer to __[[6.3.1 Speed instruction input setting>>http://13.229.109.52:8080/wiki/servo/view/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/06%20Operation/#HSpeedinstructioninputsetting]]__.
353 |(% style="text-align:center; vertical-align:middle" %)1*|(% style="text-align:center; vertical-align:middle" %)AI_1 analog input|(% style="text-align:center; vertical-align:middle" %)Please refer to __[[4 Wiring>>http://13.229.109.52:8080/wiki/servo/view/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/04%20Wiring/]]__.
354
355 “*” indicates that the VD2F servo drive does not support this function code.
356 )))
357
358 (% class="table-bordered" %)
359 |(% rowspan="3" style="text-align:center; vertical-align:middle" %)**P01-02**|(% style="text-align:center; vertical-align:middle" %)**Parameter name**|(% style="text-align:center; vertical-align:middle" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
360 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)Internal speed instruction 0|(% rowspan="2" style="text-align:center; vertical-align:middle" %)Operation setting|(% rowspan="2" style="text-align:center; vertical-align:middle" %)Effective immediately|(% rowspan="2" style="text-align:center; vertical-align:middle" %)0|(% style="text-align:center; vertical-align:middle" %)-3000 to 3000|(% rowspan="2" style="text-align:center; vertical-align:middle" %)Speed mode|(% rowspan="2" style="text-align:center; vertical-align:middle" %)rpm
361 |(% style="text-align:center; vertical-align:middle" %)-5000 to 5000*
362 |(% colspan="8" %)Used to set speed value of internal speed instruction when servo drive is in speed control mode, and only valid when P01-01=0. “*” indicates that the setting range of VD2F servo drive.
363
364 (% class="table-bordered" %)
365 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**P01-03**|(% style="text-align:center; vertical-align:middle" %)**Parameter name**|(% style="text-align:center; vertical-align:middle" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
366 |(% style="text-align:center; vertical-align:middle" %)Acceleration time|(% style="text-align:center; vertical-align:middle" %)Operation setting|(% style="text-align:center; vertical-align:middle" %)Effective immediately|(% style="text-align:center; vertical-align:middle" %)50|(% style="text-align:center; vertical-align:middle" %)0 to 65535|(% style="text-align:center; vertical-align:middle" %)Speed mode|(% style="text-align:center; vertical-align:middle" %)ms
367 |(% colspan="8" %)(((
368 The time that the speed instruction accelerates from 0 to 1000 rpm.
369
370 Please refer to __[[6.3.2 Acceleration and deceleration time setting>>http://13.229.109.52:8080/wiki/servo/view/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/06%20Operation/#HAccelerationanddecelerationtimesetting]]__
371 )))
372
373 (% class="table-bordered" %)
374 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**P01-04**|(% style="text-align:center; vertical-align:middle" %)**Parameter name**|(% style="text-align:center; vertical-align:middle" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
375 |(% style="text-align:center; vertical-align:middle" %)deceleration time|(% style="text-align:center; vertical-align:middle" %)Operation setting|(% style="text-align:center; vertical-align:middle" %)Effective immediately|(% style="text-align:center; vertical-align:middle" %)50|(% style="text-align:center; vertical-align:middle" %)0 to 65535|(% style="text-align:center; vertical-align:middle" %)Speed mode|(% style="text-align:center; vertical-align:middle" %)ms
376 |(% colspan="8" %)(((
377 The time that the speed instruction decelerates from 0 to 1000 rpm.
378
379 Please refer to __[[6.3.2 Acceleration and deceleration time setting>>http://13.229.109.52:8080/wiki/servo/view/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/06%20Operation/#HAccelerationanddecelerationtimesetting]]__
380 )))
381
382 (% class="table-bordered" %)
383 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**P01-06**|(% style="text-align:center; vertical-align:middle; width:224px" %)**Parameter name**|(% style="text-align:center; vertical-align:middle; width:194px" %)**Setting method**|(% style="text-align:center; vertical-align:middle; width:231px" %)**Effective time**|(% style="text-align:center; vertical-align:middle; width:101px" %)**Default**|(% style="text-align:center; vertical-align:middle; width:130px" %)**Range**|(% style="text-align:center; vertical-align:middle; width:153px" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
384 |(% style="text-align:center; vertical-align:middle; width:224px" %)Position instruction source|(% style="text-align:center; vertical-align:middle; width:194px" %)Operation setting|(% style="text-align:center; vertical-align:middle; width:231px" %)Effective immediately|(% style="text-align:center; vertical-align:middle; width:101px" %)0|(% style="text-align:center; vertical-align:middle; width:130px" %)0 to 1|(% style="text-align:center; vertical-align:middle; width:153px" %)-|(% style="text-align:center; vertical-align:middle" %)-
385 |(% colspan="8" %)(((
386 Used to select position instruction source when servo drive is in position control mode.
387
388 (% class="table-bordered" %)
389 |(% style="text-align:center; vertical-align:middle; width:115px" %)**Setting value**|(% style="text-align:center; vertical-align:middle; width:174px" %)**Instruction source**|(% style="text-align:center; vertical-align:middle; width:894px" %)**Remarks**
390 |(% style="text-align:center; vertical-align:middle; width:115px" %)0|(% style="text-align:center; vertical-align:middle; width:174px" %)Pulse instruction|(% style="width:894px" %)Pulse instructions are generated by PLC or other pulse generator and input to servo drive via the hardware terminals. Please refer to __[[6.2.1 Position instruction input setting>>http://13.229.109.52:8080/wiki/servo/view/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/06%20Operation/#HPositioninstructioninputsetting]]__
391 |(% style="text-align:center; vertical-align:middle; width:115px" %)1|(% style="text-align:center; vertical-align:middle; width:174px" %)Internal position instruction|(% style="width:894px" %)The internal multi-segment position instruction is triggered by DI function 20 (internal multi-segment position enable signal). Please refer to __[[internal multi-segment position function>>url:http://docs.we-con.com.cn/wiki/servo/view/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/#F611]]__.
392
393 “*” indicates that the VD2F servo drive does not support this function code.
394 )))
395
396 (% class="table-bordered" %)
397 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**P01-07**|(% style="text-align:center; vertical-align:middle" %)**Parameter name**|(% style="text-align:center; vertical-align:middle" %)**Setting method**|(% style="text-align:center; vertical-align:middle; width:184px" %)**Effective time**|(% style="text-align:center; vertical-align:middle; width:126px" %)**Default**|(% style="text-align:center; vertical-align:middle; width:105px" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
398 |(% style="text-align:center; vertical-align:middle" %)(((
399 Torque instruction source
400 )))|(% style="text-align:center; vertical-align:middle" %)Shutdown setting|(% style="text-align:center; vertical-align:middle; width:184px" %)Effective immediately|(% style="text-align:center; vertical-align:middle; width:126px" %)0|(% style="text-align:center; vertical-align:middle; width:105px" %)0 to 1|(% style="text-align:center; vertical-align:middle" %)Torque mode|(% style="text-align:center; vertical-align:middle" %)-
401 |(% colspan="8" %)(((
402 Used to select torque instruction source when servo drive is in torque control mode.
403
404 (% class="table-bordered" %)
405 |(% style="text-align:center; vertical-align:middle" %)**Setting value**|(% style="text-align:center; vertical-align:middle" %)**Instruction source**|(% style="text-align:center; vertical-align:middle" %)**Remarks**
406 |(% style="text-align:center; vertical-align:middle" %)0|(% style="text-align:center; vertical-align:middle" %)Internal torque instruction|Please refer to __[[6.4.1 Torque instruction input setting>>http://13.229.109.52:8080/wiki/servo/view/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/06%20Operation/#HTorqueinstructioninputsetting]]__
407 |(% style="text-align:center; vertical-align:middle" %)1*|(% style="text-align:center; vertical-align:middle" %)AI_1 analog input|Please refer to __[[4 Wiring>>http://13.229.109.52:8080/wiki/servo/view/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/04%20Wiring/]]__
408
409 “*” indicates that the VD2F servo drive does not support this instruction source
410 )))
411
412 (% class="table-bordered" %)
413 |(% rowspan="2" style="text-align:center; vertical-align:middle; width:120px" %)**P01-08**|(% colspan="2" style="text-align:center; vertical-align:middle; width:173px" %)**Parameter name**|(% colspan="2" style="text-align:center; vertical-align:middle; width:164px" %)**Setting method**|(% colspan="2" style="text-align:center; vertical-align:middle; width:85px" %)**Effective time**|(% colspan="2" style="text-align:center; vertical-align:middle; width:261px" %)**Default**|(% colspan="2" style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% colspan="2" style="text-align:center; vertical-align:middle" %)**Unit**
414 |(% colspan="2" style="text-align:center; vertical-align:middle; width:173px" %)Torque instruction keyboard setting value|(% colspan="2" style="text-align:center; vertical-align:middle; width:164px" %)Operation setting|(% colspan="2" style="text-align:center; vertical-align:middle; width:85px" %)Effective immediately|(% colspan="2" style="text-align:center; vertical-align:middle; width:261px" %)0|(% colspan="2" style="text-align:center; vertical-align:middle" %)-3000 to 3000|(% style="text-align:center; vertical-align:middle" %) |(% colspan="2" style="text-align:center; vertical-align:middle" %)0.1%
415 |(% colspan="14" %)Used to set the required torque instruction value when P01-07 is set to 0 (internal torque instruction).
416 |(% rowspan="2" style="text-align:center; vertical-align:middle; width:120px" %)**P01-09**|(% style="text-align:center; vertical-align:middle; width:171px" %)**Parameter name**|(% colspan="2" style="text-align:center; vertical-align:middle; width:202px" %)**Setting method**|(% colspan="2" style="text-align:center; vertical-align:middle; width:145px" %)**Effective time**|(% colspan="2" style="text-align:center; vertical-align:middle; width:79px" %)**Default**|(% colspan="2" style="text-align:center; vertical-align:middle; width:224px" %)**Range**|(% colspan="3" style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
417 |(% style="text-align:center; vertical-align:middle; width:171px" %)Speed limit source in torque mode|(% colspan="2" style="text-align:center; vertical-align:middle; width:202px" %)Shutdown setting|(% colspan="2" style="text-align:center; vertical-align:middle; width:145px" %)Effective immediately|(% colspan="2" style="text-align:center; vertical-align:middle; width:79px" %)0|(% colspan="2" style="text-align:center; vertical-align:middle; width:224px" %)0 to 1|(% colspan="3" style="text-align:center; vertical-align:middle" %)Torque mode|(% style="text-align:center; vertical-align:middle" %)-
418 |(% colspan="14" %)(((
419 Used to set speed limit source when servo drive is in torque control mode.
420
421 (% class="table-bordered" %)
422 |(% style="text-align:center; vertical-align:middle" %)**Setting value**|(% style="text-align:center; vertical-align:middle" %)**Instruction source**|(% style="text-align:center; vertical-align:middle" %)**Remarks**
423 |(% style="text-align:center; vertical-align:middle" %)0|(% style="text-align:center; vertical-align:middle" %)Internal instruction|Please refer to __[[6.4.4 Speed limit in torque mode>>http://13.229.109.52:8080/wiki/servo/view/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/06%20Operation/#HSpeedlimitintorquemode]]__
424 |(% style="text-align:center; vertical-align:middle" %)1*|(% style="text-align:center; vertical-align:middle" %)AI_2 analog input|Please refer to __[[4 Wiring>>http://13.229.109.52:8080/wiki/servo/view/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/04%20Wiring/]]__
425
426 “*” indicates that the VD2F servo drive does not support this instruction source.
427 )))
428
429 (% class="table-bordered" %)
430 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**P01-10**|(% style="text-align:center; vertical-align:middle" %)**Parameter name**|(% style="text-align:center; vertical-align:middle" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
431 |(% style="text-align:center; vertical-align:middle" %)Maximum speed threshold|(% style="text-align:center; vertical-align:middle" %)Operation setting|(% style="text-align:center; vertical-align:middle" %)Effective immediately|(% style="text-align:center; vertical-align:middle" %)3600|(% style="text-align:center; vertical-align:middle" %)0 to 5000|(% style="text-align:center; vertical-align:middle" %)Protection and restriction|(% style="text-align:center; vertical-align:middle" %)rpm
432 |(% colspan="8" %)Used to set the maximum speed limit value. If the actual speed of motor exceeds this value, Er.32 would occur (Exceed the maximum speed of motor).
433
434 (% class="table-bordered" %)
435 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**P01-11**|(% style="text-align:center; vertical-align:middle; width:242px" %)**Parameter name**|(% style="text-align:center; vertical-align:middle; width:171px" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
436 |(% style="text-align:center; vertical-align:middle; width:242px" %)Warning speed threshold|(% style="text-align:center; vertical-align:middle; width:171px" %)Operation setting|(% style="text-align:center; vertical-align:middle" %)Effective immediately|(% style="text-align:center; vertical-align:middle" %)3300|(% style="text-align:center; vertical-align:middle" %)0 to 5000|(% style="text-align:center; vertical-align:middle" %)Protection and restriction|(% style="text-align:center; vertical-align:middle" %)rpm
437 |(% colspan="8" %)Used to set the limit value of maximum speed. If the actual speed of motor exceeds this value, A-81 would occur (Exceed the maximum speed of motor).
438
439 (% class="table-bordered" %)
440 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**P01-12**|(% style="text-align:center; vertical-align:middle" %)**Parameter name**|(% style="text-align:center; vertical-align:middle" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
441 |(% style="text-align:center; vertical-align:middle" %)Forward speed threshold|(% style="text-align:center; vertical-align:middle" %)Operation setting|(% style="text-align:center; vertical-align:middle" %)Effective immediately|(% style="text-align:center; vertical-align:middle" %)3000|(% style="text-align:center; vertical-align:middle" %)0 to 5000|(% style="text-align:center; vertical-align:middle" %)Protection and restriction|(% style="text-align:center; vertical-align:middle" %)rpm
442 |(% colspan="8" %)Used to set the limit value of forward speed
443
444 (% class="table-bordered" %)
445 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**P01-13**|(% style="text-align:center; vertical-align:middle" %)**Parameter name**|(% style="text-align:center; vertical-align:middle" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
446 |(% style="text-align:center; vertical-align:middle" %)Reverse speed threshold|(% style="text-align:center; vertical-align:middle" %)Operation setting|(% style="text-align:center; vertical-align:middle" %)Effective immediately|(% style="text-align:center; vertical-align:middle" %)3000|(% style="text-align:center; vertical-align:middle" %)0 to 5000|(% style="text-align:center; vertical-align:middle" %)Protection and restriction|(% style="text-align:center; vertical-align:middle" %)rpm
447 |(% colspan="8" %)Used to set the limit value of reverse speed
448
449 (% class="table-bordered" %)
450 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**P01-14**|(% style="text-align:center; vertical-align:middle; width:229px" %)**Parameter name**|(% style="text-align:center; vertical-align:middle; width:175px" %)**Setting method**|(% style="text-align:center; vertical-align:middle; width:211px" %)**Effective time**|(% style="text-align:center; vertical-align:middle; width:88px" %)**Default**|(% style="text-align:center; vertical-align:middle; width:104px" %)**Range**|(% style="text-align:center; vertical-align:middle; width:239px" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
451 |(% style="text-align:center; vertical-align:middle; width:229px" %)Torque limit source|(% style="text-align:center; vertical-align:middle; width:175px" %)Shutdown setting|(% style="text-align:center; vertical-align:middle; width:211px" %)Effective immediately|(% style="text-align:center; vertical-align:middle; width:88px" %)0|(% style="text-align:center; vertical-align:middle; width:104px" %)0 to 1|(% style="text-align:center; vertical-align:middle; width:239px" %)Protection and restriction|(% style="text-align:center; vertical-align:middle" %)-
452 |(% colspan="8" %)Used to select torque instruction source when servo drive is in torque control mode.(((
453 (% class="table-bordered" %)
454 |(% style="text-align:center; vertical-align:middle" %)**Setting value**|(% style="text-align:center; vertical-align:middle" %)**Instruction source**|(% style="text-align:center; vertical-align:middle" %)**Remarks**
455 |(% style="text-align:center; vertical-align:middle" %)0|(% style="text-align:center; vertical-align:middle" %)Internal instruction|Please refer to __[[6.4.3 Torque instruction limit>>http://13.229.109.52:8080/wiki/servo/view/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/06%20Operation/#HTorqueinstructionlimit]]__
456 |(% style="text-align:center; vertical-align:middle" %)1|(% style="text-align:center; vertical-align:middle" %)AI_2 analog input|Please refer to __[[4 Wiring>>http://13.229.109.52:8080/wiki/servo/view/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/04%20Wiring/]]__
457 )))
458
459 (% class="table-bordered" %)
460 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**P01-15**|(% style="text-align:center; vertical-align:middle" %)**Parameter name**|(% style="text-align:center; vertical-align:middle" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
461 |(% style="text-align:center; vertical-align:middle" %)(((
462 Forward torque limit
463 )))|(% style="text-align:center; vertical-align:middle" %)Operation setting|(% style="text-align:center; vertical-align:middle" %)Effective immediately|(% style="text-align:center; vertical-align:middle" %)3000|(% style="text-align:center; vertical-align:middle" %)0 to 3000|(% style="text-align:center; vertical-align:middle" %)Protection and restriction|(% style="text-align:center; vertical-align:middle" %)0.1%
464 |(% colspan="8" %)Used to set the limit value of forward speed
465
466 (% class="table-bordered" %)
467 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**P01-16**|(% style="text-align:center; vertical-align:middle; width:207px" %)**Parameter name**|(% style="text-align:center; vertical-align:middle; width:174px" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
468 |(% style="text-align:center; vertical-align:middle; width:207px" %)(((
469 Reverse torque limit
470 )))|(% style="text-align:center; vertical-align:middle; width:174px" %)Operation setting|(% style="text-align:center; vertical-align:middle" %)Effective immediately|(% style="text-align:center; vertical-align:middle" %)3000|(% style="text-align:center; vertical-align:middle" %)0 to 3000|(% style="text-align:center; vertical-align:middle" %)Protection and restriction|(% style="text-align:center; vertical-align:middle" %)0.1%
471 |(% colspan="8" %)(((
472 When P01-14 is set to 0 ()internal) , the setting value of this function code is reverse torque limit value.
473
474 If the value of P01-15 and P01-16 is set too small, the servo motor may be insufficient torque phenomenon when performing acceleration and deceleration movements. Please refer to __[[6.4.3 Torque instruction limit>>http://13.229.109.52:8080/wiki/servo/view/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/06%20Operation/#HTorqueinstructionlimit]]__.
475 )))
476
477 (% class="table-bordered" %)
478 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**P01-17**|(% style="text-align:center; vertical-align:middle; width:264px" %)**Parameter name**|(% style="text-align:center; vertical-align:middle; width:206px" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
479 |(% style="text-align:center; vertical-align:middle; width:264px" %)Forward speed limit in torque mode|(% style="text-align:center; vertical-align:middle; width:206px" %)Operation setting|(% style="text-align:center; vertical-align:middle" %)Effective immediately|(% style="text-align:center; vertical-align:middle" %)3000|(% style="text-align:center; vertical-align:middle" %)0 to 5000|(% style="text-align:center; vertical-align:middle" %)Protection and restriction|(% style="text-align:center; vertical-align:middle" %)rpm
480 |(% colspan="8" %)Used to set forward speed limit value in torque control mode. Please refer to __[[6.4.4 Speed limit in torque mode>>http://13.229.109.52:8080/wiki/servo/view/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/06%20Operation/#HSpeedlimitintorquemode]]__
481 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**P01-18**|(% style="text-align:center; vertical-align:middle; width:264px" %)**Parameter name**|(% style="text-align:center; vertical-align:middle; width:206px" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
482 |(% style="text-align:center; vertical-align:middle; width:264px" %)Reverse speed limit in torque mode|(% style="text-align:center; vertical-align:middle; width:206px" %)Operation setting|(% style="text-align:center; vertical-align:middle" %)Effective immediately|(% style="text-align:center; vertical-align:middle" %)3000|(% style="text-align:center; vertical-align:middle" %)0 to 5000|(% style="text-align:center; vertical-align:middle" %)Protection and restriction|(% style="text-align:center; vertical-align:middle" %)rpm
483 |(% colspan="8" %)Used to set reverse speed limit value in torque control mode. Please refer to __[[6.4.4 Speed limit in torque mode>>http://13.229.109.52:8080/wiki/servo/view/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/06%20Operation/#HSpeedlimitintorquemode]]__
484
485 (% class="table-bordered" %)
486 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**P01-19**|(% style="text-align:center; vertical-align:middle" %)**Parameter name**|(% style="text-align:center; vertical-align:middle" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
487 |(% style="text-align:center; vertical-align:middle" %)Torque saturation timeout|(% style="text-align:center; vertical-align:middle" %)Operation setting|(% style="text-align:center; vertical-align:middle" %)Effective immediately|(% style="text-align:center; vertical-align:middle" %)1000|(% style="text-align:center; vertical-align:middle" %)0 to 65535|(% style="text-align:center; vertical-align:middle" %)Protection and restriction|(% style="text-align:center; vertical-align:middle" %)ms
488 |(% colspan="8" %)(((
489 When torque is limited by the setting value of P01-15 or P01-16, and exceeds the setting time, drive would report fault “torque saturation abnormal”.
490
491 ✎**Note:** When this function code is set to 0, saturation timeout fault detection would not be performed, and ignore this fault,
492 )))
493
494 (% class="table-bordered" %)
495 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**P01-21**|(% style="text-align:center; vertical-align:middle; width:280px" %)**Parameter name**|(% style="text-align:center; vertical-align:middle; width:175px" %)**Setting method**|(% style="text-align:center; vertical-align:middle; width:218px" %)**Effective time**|(% style="text-align:center; vertical-align:middle; width:147px" %)**Default**|(% style="text-align:center; vertical-align:middle; width:93px" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
496 |(% style="text-align:center; vertical-align:middle; width:280px" %)Zero-speed clamp function selection|(% style="text-align:center; vertical-align:middle; width:175px" %)Operation setting|(% style="text-align:center; vertical-align:middle; width:218px" %)Effective immediately|(% style="text-align:center; vertical-align:middle; width:147px" %)0|(% style="text-align:center; vertical-align:middle; width:93px" %)0 to 3|(% style="text-align:center; vertical-align:middle" %)Speed mode|(% style="text-align:center; vertical-align:middle" %)-
497 |(% colspan="8" %)Please refer to __[[6.3.4 Zero-speed clamp function>>http://13.229.109.52:8080/wiki/servo/view/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/06%20Operation/#HZero-speedclampfunction]]__(((
498 (% class="table-bordered" %)
499 |(% style="text-align:center; vertical-align:middle" %)**Setting value**|(% style="text-align:center; vertical-align:middle" %)**Function**
500 |(% style="text-align:center; vertical-align:middle" %)0|Force speed to 0
501 |(% style="text-align:center; vertical-align:middle" %)1|Force speed to 0, and keep position locked when the actual speed is less than P01-22
502 |(% style="text-align:center; vertical-align:middle" %)2|When the actual speed is less than P01-22, force speed to 0, and keep position locked
503 |(% style="text-align:center; vertical-align:middle" %)3|Invalid. Ignore zero-speed clamp input
504 )))
505
506 (% class="table-bordered" %)
507 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**P01-22**|(% style="text-align:center; vertical-align:middle; width:280px" %)**Parameter name**|(% style="text-align:center; vertical-align:middle; width:172px" %)**Setting method**|(% style="text-align:center; vertical-align:middle; width:222px" %)**Effective time**|(% style="text-align:center; vertical-align:middle; width:145px" %)**Default**|(% style="text-align:center; vertical-align:middle; width:97px" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
508 |(% style="text-align:center; vertical-align:middle; width:280px" %)Zero speed clamp speed threshold|(% style="text-align:center; vertical-align:middle; width:172px" %)Operation setting|(% style="text-align:center; vertical-align:middle; width:222px" %)Effective immediately|(% style="text-align:center; vertical-align:middle; width:145px" %)20|(% style="text-align:center; vertical-align:middle; width:97px" %)0 to 1000|(% style="text-align:center; vertical-align:middle" %)Speed mode|(% style="text-align:center; vertical-align:middle" %)rpm
509 |(% colspan="8" %)Used to set the speed threshold of zero-speed clamp function Please refer to __[[6.3.4 Zero-speed clamp function>>http://13.229.109.52:8080/wiki/servo/view/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/06%20Operation/#HZero-speedclampfunction]]__.
510
511 (% class="table-bordered" %)
512 |(% rowspan="3" style="text-align:center; vertical-align:middle" %)**P01-23**|(% style="text-align:center; vertical-align:middle" %)**Parameter name**|(% style="text-align:center; vertical-align:middle" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
513 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)(((
514 Internal speed Instruction 1
515 )))|(% rowspan="2" style="text-align:center; vertical-align:middle" %)Operation setting|(% rowspan="2" style="text-align:center; vertical-align:middle" %)Effective immediately|(% rowspan="2" style="text-align:center; vertical-align:middle" %)0|(% style="text-align:center; vertical-align:middle" %)-3000 to 3000|(% rowspan="2" style="text-align:center; vertical-align:middle" %)Speed mode|(% rowspan="2" style="text-align:center; vertical-align:middle" %)rpm
516 |(% style="text-align:center; vertical-align:middle" %)-5000 to 5000
517 |(% colspan="8" %)(((
518 Used to set the speed value of internal speed instruction 2. To use internal speed instruction 1 to 7, you need to set 3 DI terminals as DI function 13 (INSPD1, internal speed instruction 1) to (INSPD3, internal speed instruction 3) . The switch of the internal speed instruction section is realized by controlling the DI terminal logic of the servo control device. The running instruction segment number is 3-bit binary number. The corresponding relationships between internal speed instruction 1 to 3 and running segment number are as below.
519
520 (% class="table-bordered" %)
521 |(% style="text-align:center; vertical-align:middle" %)**INSPD3**|(% style="text-align:center; vertical-align:middle" %)**INSPD2**|(% style="text-align:center; vertical-align:middle" %)**INSPD1**|(% style="text-align:center; vertical-align:middle" %)**Internal speed instruction segment number**
522 |(% style="text-align:center; vertical-align:middle" %)0|(% style="text-align:center; vertical-align:middle" %)0|(% style="text-align:center; vertical-align:middle" %)0|(% style="text-align:center; vertical-align:middle" %)0
523 |(% style="text-align:center; vertical-align:middle" %)0|(% style="text-align:center; vertical-align:middle" %)0|(% style="text-align:center; vertical-align:middle" %)1|(% style="text-align:center; vertical-align:middle" %)1
524 |(% style="text-align:center; vertical-align:middle" %)0|(% style="text-align:center; vertical-align:middle" %)1|(% style="text-align:center; vertical-align:middle" %)0|(% style="text-align:center; vertical-align:middle" %)2
525 |(% colspan="4" %)…………
526 |(% style="text-align:center; vertical-align:middle" %)1|(% style="text-align:center; vertical-align:middle" %)1|(% style="text-align:center; vertical-align:middle" %)1|(% style="text-align:center; vertical-align:middle" %)7
527
528 Please refer to __[[6.3.1 Speed instruction input setting>>http://13.229.109.52:8080/wiki/servo/view/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/06%20Operation/#HSpeedinstructioninputsetting]]__
529
530 “*” indicates that the setting range of VD2F servo drive.
531 )))
532
533 (% class="table-bordered" %)
534 |(% rowspan="3" style="text-align:center; vertical-align:middle" %)**P01-24**|(% style="text-align:center; vertical-align:middle" %)**Parameter name**|(% style="text-align:center; vertical-align:middle" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
535 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)(((
536 Internal speed Instruction 2
537 )))|(% rowspan="2" style="text-align:center; vertical-align:middle" %)Operation setting|(% rowspan="2" style="text-align:center; vertical-align:middle" %)Effective immediately|(% rowspan="2" style="text-align:center; vertical-align:middle" %)0|(% style="text-align:center; vertical-align:middle" %)-3000 to 3000|(% rowspan="2" style="text-align:center; vertical-align:middle" %)Speed mode|(% rowspan="2" style="text-align:center; vertical-align:middle" %)rpm
538 |(% style="text-align:center; vertical-align:middle" %)-5000 to 5000*
539 |(% colspan="8" %)(((
540 Used to set the speed value of internal speed instruction 2.
541
542 “*” indicates that the setting range of VD2F servo drive.
543 )))
544
545 (% class="table-bordered" %)
546 |(% rowspan="3" style="text-align:center; vertical-align:middle" %)**P01-25**|(% style="text-align:center; vertical-align:middle" %)**Parameter name**|(% style="text-align:center; vertical-align:middle" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
547 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)(((
548 Internal speed Instruction 3
549 )))|(% rowspan="2" style="text-align:center; vertical-align:middle" %)Operation setting|(% rowspan="2" style="text-align:center; vertical-align:middle" %)Effective immediately|(% rowspan="2" style="text-align:center; vertical-align:middle" %)0|(% style="text-align:center; vertical-align:middle" %)-3000 to 3000|(% rowspan="2" style="text-align:center; vertical-align:middle" %)Speed mode|(% rowspan="2" style="text-align:center; vertical-align:middle" %)rpm
550 |(% style="text-align:center; vertical-align:middle" %)-5000 to 5000*
551 |(% colspan="8" %)(((
552 Used to set the speed value of internal speed instruction 3.
553
554 “*” indicates that the setting range of VD2F servo drive.
555 )))
556 |(% rowspan="3" style="text-align:center; vertical-align:middle" %)**P01-26**|(% style="text-align:center; vertical-align:middle" %)**Parameter name**|(% style="text-align:center; vertical-align:middle" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
557 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)(((
558 Internal speed Instruction 4
559 )))|(% rowspan="2" style="text-align:center; vertical-align:middle" %)Operation setting|(% rowspan="2" style="text-align:center; vertical-align:middle" %)Effective immediately|(% rowspan="2" style="text-align:center; vertical-align:middle" %)0|(% style="text-align:center; vertical-align:middle" %)-3000 to 3000|(% rowspan="2" style="text-align:center; vertical-align:middle" %)Speed mode|(% rowspan="2" style="text-align:center; vertical-align:middle" %)rpm
560 |(% style="text-align:center; vertical-align:middle" %)-5000 to 5000*
561 |(% colspan="8" %)(((
562 Used to set the speed value of internal speed instruction 4.
563
564 “*” indicates that the setting range of VD2F servo drive.
565 )))
566
567 (% class="table-bordered" %)
568 |(% rowspan="3" style="text-align:center; vertical-align:middle" %)**P01-27**|(% style="text-align:center; vertical-align:middle" %)**Parameter name**|(% style="text-align:center; vertical-align:middle" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
569 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)(((
570 Internal speed Instruction 5
571 )))|(% rowspan="2" style="text-align:center; vertical-align:middle" %)Operation setting|(% rowspan="2" style="text-align:center; vertical-align:middle" %)Effective immediately|(% rowspan="2" style="text-align:center; vertical-align:middle" %)0|(% style="text-align:center; vertical-align:middle" %)-3000 to 3000|(% rowspan="2" style="text-align:center; vertical-align:middle" %)Speed mode|(% rowspan="2" style="text-align:center; vertical-align:middle" %)rpm
572 |(% style="text-align:center; vertical-align:middle" %)-5000 to 5000*
573 |(% colspan="8" %)(((
574 Used to set the speed value of internal speed instruction 5.
575
576 “*” indicates that the setting range of VD2F servo drive.
577 )))
578
579 (% class="table-bordered" %)
580 |(% rowspan="3" style="text-align:center; vertical-align:middle" %)**P01-28**|(% style="text-align:center; vertical-align:middle" %)**Parameter name**|(% style="text-align:center; vertical-align:middle" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
581 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)(((
582 Internal speed Instruction 6
583 )))|(% rowspan="2" style="text-align:center; vertical-align:middle" %)Operation setting|(% rowspan="2" style="text-align:center; vertical-align:middle" %)Effective immediately|(% rowspan="2" style="text-align:center; vertical-align:middle" %)0|(% style="text-align:center; vertical-align:middle" %)-3000 to 3000|(% rowspan="2" style="text-align:center; vertical-align:middle" %)Speed mode|(% rowspan="2" style="text-align:center; vertical-align:middle" %)rpm
584 |(% style="text-align:center; vertical-align:middle" %)-5000 to 5000*
585 |(% colspan="8" %)(((
586 Used to set the speed value of internal speed instruction 6.
587
588 “*” indicates that the setting range of VD2F servo drive.
589 )))
590
591 (% class="table-bordered" %)
592 |(% rowspan="3" style="text-align:center; vertical-align:middle" %)**P01-29**|(% style="text-align:center; vertical-align:middle" %)**Parameter name**|(% style="text-align:center; vertical-align:middle" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
593 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)(((
594 Internal speed Instruction 7
595 )))|(% rowspan="2" style="text-align:center; vertical-align:middle" %)Operation setting|(% rowspan="2" style="text-align:center; vertical-align:middle" %)Effective immediately|(% rowspan="2" style="text-align:center; vertical-align:middle" %)0|(% style="text-align:center; vertical-align:middle" %)-3000 to 3000|(% rowspan="2" style="text-align:center; vertical-align:middle" %)Speed mode|(% rowspan="2" style="text-align:center; vertical-align:middle" %)rpm
596 |(% style="text-align:center; vertical-align:middle" %)-5000 to 5000*
597 |(% colspan="8" %)(((
598 Used to set the speed value of internal speed instruction 7.
599
600 “*” indicates that the setting range of VD2F servo drive.
601 )))
602
603 |(% rowspan="2" %)**P01-30**|**Parameter name**|**Setting method**|**Effective time**|**Default**|**Range**|**Category**|**Unit**
604 |Delay from brake output ON to instruction reception|Operation setting|Effective immediately|250|0 to 500|-|rpm
605 |(% colspan="8" %)Set the delay time from the brake (BRK-OFF) output is ON to the servo drive allows to start receiving input instructions. When the brake output (BRK-OFF) is not allocated, this function code has no effect. Please refer to __[[6.1.8 Brake device>>http://13.229.109.52:8080/wiki/servo/view/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/06%20Operation/#HBrakedevice]]__.
606
607 (% class="table-bordered" %)
608 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**P01-31**|(% style="text-align:center; vertical-align:middle" %)**Parameter name**|(% style="text-align:center; vertical-align:middle" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
609 |(% style="text-align:center; vertical-align:middle" %)Stationary state. delay from the brake output is OFF to the motor is not energized|(% style="text-align:center; vertical-align:middle" %)Operation setting|(% style="text-align:center; vertical-align:middle" %)Effective immediately|(% style="text-align:center; vertical-align:middle" %)150|(% style="text-align:center; vertical-align:middle" %)1 to 1000|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)rpm
610 |(% colspan="8" %)When the motor is in a static state, set the delay time from the brake (BRK-OFF) output is OFF to the servo drive is in the non-powered state. When the brake output (BRK-OFF) is not allocated, this function code has no effect. Please refer to __[[6.1.8 Brake device>>http://13.229.109.52:8080/wiki/servo/view/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/06%20Operation/#HBrakedevice]]__.
611
612 (% class="table-bordered" %)
613 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**P01-32**|(% style="text-align:center; vertical-align:middle" %)**Parameter name**|(% style="text-align:center; vertical-align:middle" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
614 |(% style="text-align:center; vertical-align:middle" %)Rotation state, when the brake output is OFF, the speed threshold|(% style="text-align:center; vertical-align:middle" %)Operation setting|(% style="text-align:center; vertical-align:middle" %)Effective immediately|(% style="text-align:center; vertical-align:middle" %)30|(% style="text-align:center; vertical-align:middle" %)0 to 3000|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)rpm
615 |(% colspan="8" %)The motor is rotating, the motor speed threshold when the brake (BRK-OFF) is allowed to output OFF. When the brake output (BRK-OFF) is not allocated, this function code has no effect. Please refer to __[[6.1.8 Brake device>>http://13.229.109.52:8080/wiki/servo/view/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/06%20Operation/#HBrakedevice]]__.
616
617 (% class="table-bordered" %)
618 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**P01-33**|(% style="text-align:center; vertical-align:middle; width:495px" %)**Parameter name**|(% style="text-align:center; vertical-align:middle; width:149px" %)**Setting method**|(% style="text-align:center; vertical-align:middle; width:163px" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
619 |(% style="text-align:center; vertical-align:middle; width:495px" %)Rotation status, delay from servo enable OFF to brake output OFF|(% style="text-align:center; vertical-align:middle; width:149px" %)Operation setting|(% style="text-align:center; vertical-align:middle; width:163px" %)500|(% style="text-align:center; vertical-align:middle" %) |(% style="text-align:center; vertical-align:middle" %)1 to 1000|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)rpm
620 |(% colspan="8" %)The motor is rotating, the delay time from the brake (BRK-OFF) output OFF is allowed to the servo enable (S-ON) OFF. When the brake output (BRK-OFF) is not allocated, this function code has no effect. Please refer to __[[6.1.8 Brake device>>http://13.229.109.52:8080/wiki/servo/view/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/06%20Operation/#HBrakedevice]]__.
621
622 = **Group P02 Gain adjustment** =
623
624 (% class="table-bordered" %)
625 |(% rowspan="2" style="text-align:center; vertical-align:middle; width:83px" %)**P02-01**|(% style="text-align:center; vertical-align:middle; width:245px" %)**Parameter name**|(% style="text-align:center; vertical-align:middle" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
626 |(% style="text-align:center; vertical-align:middle; width:245px" %)1st position loop gain|(% style="text-align:center; vertical-align:middle" %)Operation setting|(% style="text-align:center; vertical-align:middle" %)Effective immediately|(% style="text-align:center; vertical-align:middle" %)400|(% style="text-align:center; vertical-align:middle" %)0 to 6200|(% style="text-align:center; vertical-align:middle" %)Gain control|(% style="text-align:center; vertical-align:middle" %)0.1Hz
627 |(% colspan="8" %)Set the proportional gain of the 1st position loop to determine the responsiveness of position control system.
628
629 (% class="table-bordered" %)
630 |(% rowspan="2" style="text-align:center; vertical-align:middle; width:83px" %)**P02-02**|(% style="text-align:center; vertical-align:middle; width:240px" %)**Parameter name**|(% style="text-align:center; vertical-align:middle; width:200px" %)**Setting method**|(% style="text-align:center; vertical-align:middle; width:220px" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
631 |(% style="text-align:center; vertical-align:middle; width:240px" %)1st speed loop gain|(% style="text-align:center; vertical-align:middle; width:200px" %)Operation setting|(% style="text-align:center; vertical-align:middle; width:220px" %)Effective immediately|(% style="text-align:center; vertical-align:middle" %)65|(% style="text-align:center; vertical-align:middle" %)0 to 35000|(% style="text-align:center; vertical-align:middle" %)Gain control|(% style="text-align:center; vertical-align:middle" %)0.1Hz
632 |(% colspan="8" %)Set the proportional gain of the 1st speed loop to determine the responsiveness of speed loop.
633
634 (% class="table-bordered" %)
635 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**P02-03**|(% style="text-align:center; vertical-align:middle; width:280px" %)**Parameter name**|(% style="text-align:center; vertical-align:middle; width:206px" %)**Setting method**|(% style="text-align:center; vertical-align:middle; width:195px" %)**Effective time**|(% style="text-align:center; vertical-align:middle; width:108px" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
636 |(% style="text-align:center; vertical-align:middle; width:280px" %)1st speed loop integral time constant|(% style="text-align:center; vertical-align:middle; width:206px" %)(((
637 Operation setting
638 )))|(% style="text-align:center; vertical-align:middle; width:195px" %)Effective immediately|(% style="text-align:center; vertical-align:middle; width:108px" %)1000|(% style="text-align:center; vertical-align:middle" %)100 to 65535|(% style="text-align:center; vertical-align:middle" %)Gain control|(% style="text-align:center; vertical-align:middle" %)0.1ms
639 |(% colspan="8" %)Set the 1st speed loop integral constant. The smaller the set value, the stronger the integral effect.
640
641 (% class="table-bordered" %)
642 |(% rowspan="2" style="text-align:center; vertical-align:middle; width:84px" %)**P02-04**|(% style="text-align:center; vertical-align:middle; width:237px" %)**Parameter name**|(% style="text-align:center; vertical-align:middle; width:208px" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
643 |(% style="text-align:center; vertical-align:middle; width:237px" %)2nd position loop gain|(% style="text-align:center; vertical-align:middle; width:208px" %)Operation setting|(% style="text-align:center; vertical-align:middle" %)Effective immediately|(% style="text-align:center; vertical-align:middle" %)35|(% style="text-align:center; vertical-align:middle" %)0 to 6200|(% style="text-align:center; vertical-align:middle" %)Gain control|(% style="text-align:center; vertical-align:middle" %)0.1Hz
644 |(% colspan="8" %)Set the proportional gain of the 2nd position loop to determine the responsiveness of position control system.
645
646 (% class="table-bordered" %)
647 |(% rowspan="2" style="text-align:center; vertical-align:middle; width:87px" %)**P02-05**|(% style="text-align:center; vertical-align:middle; width:230px" %)**Parameter name**|(% style="text-align:center; vertical-align:middle; width:215px" %)**Setting method**|(% style="text-align:center; vertical-align:middle; width:224px" %)**Effective time**|(% style="text-align:center; vertical-align:middle; width:89px" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
648 |(% style="text-align:center; vertical-align:middle; width:230px" %)2nd speed loop gain|(% style="text-align:center; vertical-align:middle; width:215px" %)Operation setting|(% style="text-align:center; vertical-align:middle; width:224px" %)Effective immediately|(% style="text-align:center; vertical-align:middle; width:89px" %)65|(% style="text-align:center; vertical-align:middle" %)0 to 35000|(% style="text-align:center; vertical-align:middle" %)Gain control|(% style="text-align:center; vertical-align:middle" %)0.1Hz
649 |(% colspan="8" %)Set the proportional gain of the 2nd speed loop to determine the responsiveness of speed loop.
650
651 (% class="table-bordered" %)
652 |(% rowspan="2" style="text-align:center; vertical-align:middle; width:85px" %)**P02-06**|(% style="text-align:center; vertical-align:middle; width:281px" %)**Parameter name**|(% style="text-align:center; vertical-align:middle; width:184px" %)**Setting method**|(% style="text-align:center; vertical-align:middle; width:209px" %)**Effective time**|(% style="text-align:center; vertical-align:middle; width:113px" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
653 |(% style="text-align:center; vertical-align:middle; width:281px" %)2nd speed loop integral time constant|(% style="text-align:center; vertical-align:middle; width:184px" %)(((
654 Operation setting
655 )))|(% style="text-align:center; vertical-align:middle; width:209px" %)Effective immediately|(% style="text-align:center; vertical-align:middle; width:113px" %)1000|(% style="text-align:center; vertical-align:middle" %)100 to 65535|(% style="text-align:center; vertical-align:middle" %)Gain control|(% style="text-align:center; vertical-align:middle" %)0.1ms
656 |(% colspan="8" %)Set the 2nd speed loop integral constant. The smaller the set value, the stronger the integral effect.
657
658 (% class="table-bordered" %)
659 |(% rowspan="2" style="text-align:center; vertical-align:middle; width:84px" %)**P02-07**|(% style="text-align:center; vertical-align:middle; width:280px" %)**Parameter name**|(% style="text-align:center; vertical-align:middle" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
660 |(% style="text-align:center; vertical-align:middle; width:280px" %)2nd gain switching mode|(% style="text-align:center; vertical-align:middle" %)(((
661 Operation setting
662 )))|(% style="text-align:center; vertical-align:middle" %)Effective immediately|(% style="text-align:center; vertical-align:middle" %)0|(% style="text-align:center; vertical-align:middle" %)0 to 3|(% style="text-align:center; vertical-align:middle" %)Gain control|(% style="text-align:center; vertical-align:middle" %)-
663 |(% colspan="8" %)Used to set the 2nd gain switching mode.(((
664 (% class="table-bordered" %)
665 |(% style="text-align:center; vertical-align:middle" %)**Setting value**|(% style="text-align:center; vertical-align:middle" %)**Definition**
666 |(% style="text-align:center; vertical-align:middle" %)0|Switch by DI terminal
667 |(% style="text-align:center; vertical-align:middle" %)1|Speed instruction change rate is too large
668 |(% style="text-align:center; vertical-align:middle" %)2|Large position deviation
669 |(% style="text-align:center; vertical-align:middle" %)3|None
670 )))
671
672 (% class="table-bordered" %)
673 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**P02-09**|(% style="text-align:center; vertical-align:middle; width:259px" %)**Parameter name**|(% style="text-align:center; vertical-align:middle; width:189px" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
674 |(% style="text-align:center; vertical-align:middle; width:259px" %)Speed feedforward gain|(% style="text-align:center; vertical-align:middle; width:189px" %)(((
675 Operation setting
676 )))|(% style="text-align:center; vertical-align:middle" %)Effective immediately|(% style="text-align:center; vertical-align:middle" %)0|(% style="text-align:center; vertical-align:middle" %)0 to 1000|(% style="text-align:center; vertical-align:middle" %)Gain control|(% style="text-align:center; vertical-align:middle" %)0.1%
677 |(% colspan="8" %)Set speed feedforward gain
678
679 (% class="table-bordered" %)
680 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**P02-10**|(% style="text-align:center; vertical-align:middle; width:298px" %)**Parameter name**|(% style="text-align:center; vertical-align:middle; width:179px" %)**Setting method**|(% style="text-align:center; vertical-align:middle; width:219px" %)**Effective time**|(% style="text-align:center; vertical-align:middle; width:118px" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
681 |(% style="text-align:center; vertical-align:middle; width:298px" %)Speed feedforward filtering time constant|(% style="text-align:center; vertical-align:middle; width:179px" %)(((
682 Operation setting
683 )))|(% style="text-align:center; vertical-align:middle; width:219px" %)Effective immediately|(% style="text-align:center; vertical-align:middle; width:118px" %)50|(% style="text-align:center; vertical-align:middle" %)0 to 10000|(% style="text-align:center; vertical-align:middle" %)Gain control|(% style="text-align:center; vertical-align:middle" %)0.1ms
684 |(% colspan="8" %)Set the time constant of one delay filter related to the speed feedforward input.
685 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**P02-11**|(% style="text-align:center; vertical-align:middle; width:298px" %)**Parameter name**|(% style="text-align:center; vertical-align:middle; width:179px" %)**Setting method**|(% style="text-align:center; vertical-align:middle; width:219px" %)**Effective time**|(% style="text-align:center; vertical-align:middle; width:118px" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
686 |(% style="text-align:center; vertical-align:middle; width:298px" %)Torque feedforward gain|(% style="text-align:center; vertical-align:middle; width:179px" %)(((
687 Operation setting
688 )))|(% style="text-align:center; vertical-align:middle; width:219px" %)Effective immediately|(% style="text-align:center; vertical-align:middle; width:118px" %)0|(% style="text-align:center; vertical-align:middle" %)0 to 2000|(% style="text-align:center; vertical-align:middle" %)Gain control|(% style="text-align:center; vertical-align:middle" %)0.1%
689 |(% colspan="8" %)Set torque feedforward gain
690
691 (% class="table-bordered" %)
692 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**P02-12**|(% style="text-align:center; vertical-align:middle; width:297px" %)**Parameter name**|(% style="text-align:center; vertical-align:middle; width:182px" %)**Setting method**|(% style="text-align:center; vertical-align:middle; width:216px" %)**Effective time**|(% style="text-align:center; vertical-align:middle; width:121px" %)**Default**|(% style="text-align:center; vertical-align:middle; width:103px" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
693 |(% style="text-align:center; vertical-align:middle; width:297px" %)Torque feedforward filter time constant|(% style="text-align:center; vertical-align:middle; width:182px" %)(((
694 Operation setting
695 )))|(% style="text-align:center; vertical-align:middle; width:216px" %)Effective immediately|(% style="text-align:center; vertical-align:middle; width:121px" %)50|(% style="text-align:center; vertical-align:middle; width:103px" %)0 to 10000|(% style="text-align:center; vertical-align:middle" %)Gain control|(% style="text-align:center; vertical-align:middle" %)0.1ms
696 |(% colspan="8" %)Set the time constant of one delay filter related to the torque feedforward input.
697
698 = **Group P03 Self-adjusting parameters** =
699
700 (% class="table-bordered" %)
701 |(% rowspan="2" style="text-align:center; vertical-align:middle; width:83px" %)**P03-01**|(% style="text-align:center; vertical-align:middle; width:287px" %)**Parameter name**|(% style="text-align:center; vertical-align:middle; width:186px" %)**Setting method**|(% style="text-align:center; vertical-align:middle; width:224px" %)**Effective time**|(% style="text-align:center; vertical-align:middle; width:119px" %)**Default**|(% style="text-align:center; vertical-align:middle; width:110px" %)**Range**|(% style="text-align:center; vertical-align:middle; width:125px" %)**Category**|(% style="text-align:center; vertical-align:middle; width:67px" %)**Unit**
702 |(% style="text-align:center; vertical-align:middle; width:287px" %)Load inertia ratio|(% style="text-align:center; vertical-align:middle; width:186px" %)(((
703 Operation setting
704 )))|(% style="text-align:center; vertical-align:middle; width:224px" %)Effective immediately|(% style="text-align:center; vertical-align:middle; width:119px" %)300*|(% style="text-align:center; vertical-align:middle; width:110px" %)100 to 10000|(% style="text-align:center; vertical-align:middle; width:125px" %)Self-tuning|(% style="text-align:center; vertical-align:middle; width:67px" %)0.01
705 |(% colspan="8" %)(((
706 Set load inertia ratio: 0.00 to 100.00 times.
707
708 “*” indicates that the factory defaults for different models may differ.
709 )))
710
711 (% class="table-bordered" %)
712 |(% rowspan="2" style="text-align:center; vertical-align:middle; width:83px" %)**P03-02**|(% style="text-align:center; vertical-align:middle; width:288px" %)**Parameter name**|(% style="text-align:center; vertical-align:middle; width:186px" %)**Setting method**|(% style="text-align:center; vertical-align:middle; width:225px" %)**Effective time**|(% style="text-align:center; vertical-align:middle; width:119px" %)**Default**|(% style="text-align:center; vertical-align:middle; width:100px" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
713 |(% style="text-align:center; vertical-align:middle; width:288px" %)Load rigidity grade selection|(% style="text-align:center; vertical-align:middle; width:186px" %)(((
714 Operation setting
715 )))|(% style="text-align:center; vertical-align:middle; width:225px" %)Effective immediately|(% style="text-align:center; vertical-align:middle; width:119px" %)14*|(% style="text-align:center; vertical-align:middle; width:100px" %)0 to 31|(% style="text-align:center; vertical-align:middle" %)Self-tuning|(% style="text-align:center; vertical-align:middle" %)-
716 |(% colspan="8" %)Set the rigidity of servo system. The higher the value, the faster the response, but too high rigidity will cause vibration. “*” indicates that the factory defaults for different models may differ.
717
718 (% class="table-bordered" %)
719 |(% rowspan="2" style="text-align:center; vertical-align:middle; width:84px" %)**P03-03**|(% style="text-align:center; vertical-align:middle; width:291px" %)**Parameter name**|(% style="text-align:center; vertical-align:middle; width:183px" %)**Setting method**|(% style="text-align:center; vertical-align:middle; width:230px" %)**Effective time**|(% style="text-align:center; vertical-align:middle; width:128px" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
720 |(% style="text-align:center; vertical-align:middle; width:291px" %)Self-adjusting mode selection|(% style="text-align:center; vertical-align:middle; width:183px" %)(((
721 Operation setting
722 )))|(% style="text-align:center; vertical-align:middle; width:230px" %)Effective immediately|(% style="text-align:center; vertical-align:middle; width:128px" %)0|(% style="text-align:center; vertical-align:middle" %)0 to 2|(% style="text-align:center; vertical-align:middle" %)Self-tuning|(% style="text-align:center; vertical-align:middle" %)-
723 |(% colspan="8" %)Different gain adjustment modes could be set, and the relevant gain parameters could be set manually or automatically set according to the rigidity level table.(((
724 (% class="table-bordered" %)
725 |(% style="text-align:center; vertical-align:middle; width:116px" %)**Setting value**|(% style="text-align:center; vertical-align:middle; width:177px" %)**Instruction source**|(% style="text-align:center; vertical-align:middle" %)**Remarks**
726 |(% style="text-align:center; vertical-align:middle; width:116px" %)0|(% style="width:177px" %)Self-adjusting mode.|Position loop gain, speed loop gain, speed loop integral time constant, torque filter parameter settings are automatically adjusted according to the rigidity grade setting.
727 |(% style="text-align:center; vertical-align:middle; width:116px" %)1|(% style="width:177px" %)Manual setting|You need to manually set the position loop gain, speed loop gain, speed loop integral time constant, torque filter parameter
728 |(% style="text-align:center; vertical-align:middle; width:116px" %)2|(% style="width:177px" %)Online automatic self-adjusting mode|Not implemented yet
729 )))
730
731 (% class="table-bordered" %)
732 |(% rowspan="2" style="text-align:center; vertical-align:middle; width:84px" %)**P03-04**|(% style="text-align:center; vertical-align:middle; width:283px" %)**Parameter name**|(% style="text-align:center; vertical-align:middle; width:199px" %)**Setting method**|(% style="text-align:center; vertical-align:middle; width:230px" %)**Effective time**|(% style="text-align:center; vertical-align:middle; width:126px" %)**Default**|(% style="text-align:center; vertical-align:middle; width:93px" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
733 |(% style="text-align:center; vertical-align:middle; width:283px" %)Online inertia recognition sensitivity|(% style="text-align:center; vertical-align:middle; width:199px" %)(((
734 Operation setting
735 )))|(% style="text-align:center; vertical-align:middle; width:230px" %)Effective immediately|(% style="text-align:center; vertical-align:middle; width:126px" %)0|(% style="text-align:center; vertical-align:middle; width:93px" %)0 to 2|(% style="text-align:center; vertical-align:middle" %)Self-tuning|(% style="text-align:center; vertical-align:middle" %)-
736 |(% colspan="8" %)Not implemented yet.
737
738 (% class="table-bordered" %)
739 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**P03-05**|(% style="text-align:center; vertical-align:middle; width:282px" %)**Parameter name**|(% style="text-align:center; vertical-align:middle; width:199px" %)**Setting method**|(% style="text-align:center; vertical-align:middle; width:227px" %)**Effective time**|(% style="text-align:center; vertical-align:middle; width:127px" %)**Default**|(% style="text-align:center; vertical-align:middle; width:94px" %)**Range**|(% style="text-align:center; vertical-align:middle; width:110px" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
740 |(% style="text-align:center; vertical-align:middle; width:282px" %)Number of circles Inertia recognition|(% style="text-align:center; vertical-align:middle; width:199px" %)Shutdown setting|(% style="text-align:center; vertical-align:middle; width:227px" %)Effective immediately|(% style="text-align:center; vertical-align:middle; width:127px" %)2|(% style="text-align:center; vertical-align:middle; width:94px" %)1 to 20|(% style="text-align:center; vertical-align:middle; width:110px" %)Self-tuning|(% style="text-align:center; vertical-align:middle" %)Circle
741 |(% colspan="8" %)Offline load inertia recognition process, motor rotation number setting
742
743 (% class="table-bordered" %)
744 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**P03-06**|(% style="text-align:center; vertical-align:middle; width:282px" %)**Parameter name**|(% style="text-align:center; vertical-align:middle; width:202px" %)**Setting method**|(% style="text-align:center; vertical-align:middle; width:224px" %)**Effective time**|(% style="text-align:center; vertical-align:middle; width:110px" %)**Default**|(% style="text-align:center; vertical-align:middle; width:116px" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
745 |(% style="text-align:center; vertical-align:middle; width:282px" %)(((
746 Inertia recognition maximum speed
747 )))|(% style="text-align:center; vertical-align:middle; width:202px" %)Shutdown setting|(% style="text-align:center; vertical-align:middle; width:224px" %)Effective immediately|(% style="text-align:center; vertical-align:middle; width:110px" %)1000|(% style="text-align:center; vertical-align:middle; width:116px" %)300 to 2000|(% style="text-align:center; vertical-align:middle" %)Self-tuning|(% style="text-align:center; vertical-align:middle" %)rpm
748 |(% colspan="8" %)Set the allowable maximum motor speed instruction in offline inertia recognition mode. The faster the speed during inertia recognition, the more accurate the recognition result will be. You are advised to keep the default value.
749
750 (% class="table-bordered" %)
751 |(% rowspan="2" style="text-align:center; vertical-align:middle; width:84px" %)**P03-07**|(% style="text-align:center; vertical-align:middle; width:301px" %)**Parameter name**|(% style="text-align:center; vertical-align:middle; width:170px" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
752 |(% style="text-align:center; vertical-align:middle; width:301px" %)(((
753 Parameter recognition rotation direction
754 )))|(% style="text-align:center; vertical-align:middle; width:170px" %)(((
755 Shutdown setting
756 )))|(% style="text-align:center; vertical-align:middle" %)Effective immediately|(% style="text-align:center; vertical-align:middle" %)0|(% style="text-align:center; vertical-align:middle" %)0 to 2|(% style="text-align:center; vertical-align:middle" %)Self-tuning|(% style="text-align:center; vertical-align:middle" %)-
757 |(% colspan="8" %)Set parameter recognition rotation direction(((
758 (% class="table-bordered" %)
759 |(% style="text-align:center; vertical-align:middle" %)**Setting value**|(% style="text-align:center; vertical-align:middle" %)**Rotation direction**
760 |(% style="text-align:center; vertical-align:middle" %)0|Forward and reverse reciprocating rotation
761 |(% style="text-align:center; vertical-align:middle" %)1|Forward one-way rotation
762 |(% style="text-align:center; vertical-align:middle" %)2|Reverse one-way rotation
763 )))
764
765 (% class="table-bordered" %)
766 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**P03-08**|(% style="text-align:center; vertical-align:middle" %)**Parameter name**|(% style="text-align:center; vertical-align:middle" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
767 |(% style="text-align:center; vertical-align:middle" %)(((
768 Parameter recognition waiting time
769 )))|(% style="text-align:center; vertical-align:middle" %)(((
770 Shutdown setting
771 )))|(% style="text-align:center; vertical-align:middle" %)Effective immediately|(% style="text-align:center; vertical-align:middle" %)1000|(% style="text-align:center; vertical-align:middle" %)300 to 10000|(% style="text-align:center; vertical-align:middle" %)Self-tuning|(% style="text-align:center; vertical-align:middle" %)ms
772 |(% colspan="8" %)During offline inertia recognition, the time interval between two consecutive speed instructions
773
774 = **Group P04 Vibration suppression** =
775
776 (% class="table-bordered" %)
777 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**P04-01**|(% style="text-align:center; vertical-align:middle" %)**Parameter name**|(% style="text-align:center; vertical-align:middle" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
778 |(% style="text-align:center; vertical-align:middle" %)Pulse instruction filtering method|(% style="text-align:center; vertical-align:middle" %)(((
779 Shutdown setting
780 )))|(% style="text-align:center; vertical-align:middle" %)Effective immediately|(% style="text-align:center; vertical-align:middle" %)0|(% style="text-align:center; vertical-align:middle" %)0 to 1|(% style="text-align:center; vertical-align:middle" %)Position mode|(% style="text-align:center; vertical-align:middle" %)-
781 |(% colspan="8" %)(((
782 (% class="table-bordered" %)
783 |(% style="text-align:center; vertical-align:middle" %)**Setting value**|(% style="text-align:center; vertical-align:middle" %)**Filtering method**
784 |(% style="text-align:center; vertical-align:middle" %)0|First-order low-pass filter
785 |(% style="text-align:center; vertical-align:middle" %)1|Average filtering
786 )))
787
788 (% class="table-bordered" %)
789 |(% rowspan="2" style="text-align:center; vertical-align:middle; width:90px" %)**P04-02**|(% style="text-align:center; vertical-align:middle; width:422px" %)**Parameter name**|(% style="text-align:center; vertical-align:middle; width:176px" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
790 |(% style="text-align:center; vertical-align:middle; width:422px" %)Position instruction first-order low-pass filtering time constant|(% style="text-align:center; vertical-align:middle; width:176px" %)(((
791 Shutdown setting
792 )))|(% style="text-align:center; vertical-align:middle" %)Effective immediately|(% style="text-align:center; vertical-align:middle" %)0|(% style="text-align:center; vertical-align:middle" %)0 to 1000|(% style="text-align:center; vertical-align:middle" %)Position mode|(% style="text-align:center; vertical-align:middle" %)ms
793 |(% colspan="8" %)Used to set position instructions first-order low-pass filtering time constant.(((
794 (% class="table-bordered" %)
795 |(% style="text-align:center; vertical-align:middle" %)The position instructions is rectangular waves|(% style="text-align:center; vertical-align:middle" %)[[image:image-20220608160631-5.png]]
796 |(% style="text-align:center; vertical-align:middle" %)The position instruction is trapezoidal wave|(% style="text-align:center; vertical-align:middle" %)[[image:image-20220608160833-6.png]]
797 )))
798
799 (% class="table-bordered" %)
800 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**P04-03**|(% style="text-align:center; vertical-align:middle" %)**Parameter name**|(% style="text-align:center; vertical-align:middle" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
801 |(% style="text-align:center; vertical-align:middle" %)Position instruction average filtering time constant|(% style="text-align:center; vertical-align:middle" %)(((
802 Shutdown setting
803 )))|(% style="text-align:center; vertical-align:middle" %)Effective immediately|(% style="text-align:center; vertical-align:middle" %)0|(% style="text-align:center; vertical-align:middle" %)0 to 128|(% style="text-align:center; vertical-align:middle" %)Position mode|(% style="text-align:center; vertical-align:middle" %)ms
804 |(% colspan="8" %)Used to set average filtering time constant.(((
805 (% class="table-bordered" %)
806 |(% style="text-align:center; vertical-align:middle" %)The position instructions is rectangular waves|(% style="text-align:center; vertical-align:middle" %)[[image:image-20220608155753-2.png]]
807 |(% style="text-align:center; vertical-align:middle" %)The position instruction is trapezoidal wave|(% style="text-align:center; vertical-align:middle" %)[[image:image-20220608160104-3.png]]
808 )))
809
810 (% class="table-bordered" %)
811 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**P04-04**|(% style="text-align:center; vertical-align:middle" %)**Parameter name**|(% style="text-align:center; vertical-align:middle" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
812 |(% style="text-align:center; vertical-align:middle" %)Torque filtering time constant|(% style="text-align:center; vertical-align:middle" %)Operation setting|(% style="text-align:center; vertical-align:middle" %)Effective immediately|(% style="text-align:center; vertical-align:middle" %)50|(% style="text-align:center; vertical-align:middle" %)10 to 2500|(% style="text-align:center; vertical-align:middle" %)Vibration suppression|(% style="text-align:center; vertical-align:middle" %)0.01ms
813 |(% colspan="8" %)Used to set torque filtering time constant. When the function code P03-03(Self-adjustment mode selection) is set to 0, the parameter is automatically set by servo. Please refer to __[[6.4.2 Torque instruction filtering>>http://13.229.109.52:8080/wiki/servo/view/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/06%20Operation/#HTorqueinstructionfiltering]]__
814
815 (% class="table-bordered" %)
816 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**P04-05**|(% style="text-align:center; vertical-align:middle" %)**Parameter name**|(% style="text-align:center; vertical-align:middle" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
817 |(% style="text-align:center; vertical-align:middle" %)1st notch filter frequency|(% style="text-align:center; vertical-align:middle" %)(((
818 Operation setting
819 )))|(% style="text-align:center; vertical-align:middle" %)Effective immediately|(% style="text-align:center; vertical-align:middle" %)300|(% style="text-align:center; vertical-align:middle" %)250 to 5000|(% style="text-align:center; vertical-align:middle" %)Vibration suppression|(% style="text-align:center; vertical-align:middle" %)Hz
820 |(% colspan="8" %)(((
821 Set the center frequency of the 1st notch filter.
822
823 When the function code is set to 5000, the function of the notch filter is invalid.
824 )))
825
826 (% class="table-bordered" %)
827 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**P04-06**|(% style="text-align:center; vertical-align:middle" %)**Parameter name**|(% style="text-align:center; vertical-align:middle" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
828 |(% style="text-align:center; vertical-align:middle" %)1st notch filter depth|(% style="text-align:center; vertical-align:middle" %)(((
829 Operation setting
830 )))|(% style="text-align:center; vertical-align:middle" %)Effective immediately|(% style="text-align:center; vertical-align:middle" %)100|(% style="text-align:center; vertical-align:middle" %)0 to100|(% style="text-align:center; vertical-align:middle" %)Vibration suppression|(% style="text-align:center; vertical-align:middle" %)-
831 |(% colspan="8" %)(((
832 Set the notch filter depth grade (the ratio between input and output at the center frequency of the notch filter)
833
834 The larger the set value of this function code is, the smaller the notch filter depth is, and the weaker the suppression effect of mechanical vibration is. However, setting too large could cause system instability. Please refer to __[[7.4.2 Notch filter>>http://13.229.109.52:8080/wiki/servo/view/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/07%20Adjustments/#HNotchfilter]]__
835 )))
836
837 (% class="table-bordered" %)
838 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**P04-07**|(% style="text-align:center; vertical-align:middle" %)**Parameter name**|(% style="text-align:center; vertical-align:middle" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
839 |(% style="text-align:center; vertical-align:middle" %)1st notch filter width|(% style="text-align:center; vertical-align:middle" %)(((
840 Operation setting
841 )))|(% style="text-align:center; vertical-align:middle" %)Effective immediately|(% style="text-align:center; vertical-align:middle" %)4|(% style="text-align:center; vertical-align:middle" %)0 to 12|(% style="text-align:center; vertical-align:middle" %)Vibration suppression|(% style="text-align:center; vertical-align:middle" %)-
842 |(% colspan="8" %)Set the notch filter width grade (the ratio between input and output at the center frequency of the notch filter)
843
844 (% class="table-bordered" %)
845 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**P04-08**|(% style="text-align:center; vertical-align:middle" %)**Parameter name**|(% style="text-align:center; vertical-align:middle" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
846 |(% style="text-align:center; vertical-align:middle" %)2nd notch filter frequency|(% style="text-align:center; vertical-align:middle" %)(((
847 Operation setting
848 )))|(% style="text-align:center; vertical-align:middle" %)Effective immediately|(% style="text-align:center; vertical-align:middle" %)500|(% style="text-align:center; vertical-align:middle" %)250 to 5000|(% style="text-align:center; vertical-align:middle" %)Vibration suppression|(% style="text-align:center; vertical-align:middle" %)Hz
849 |(% colspan="8" %)(((
850 Set the center frequency of the 1st notch filter.
851
852 When the function code is set to 5000, the function of the notch filter is invalid.
853 )))
854
855 (% class="table-bordered" %)
856 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**P04-09**|(% style="text-align:center; vertical-align:middle" %)**Parameter name**|(% style="text-align:center; vertical-align:middle" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
857 |(% style="text-align:center; vertical-align:middle" %)2nd notch filter depth|(% style="text-align:center; vertical-align:middle" %)(((
858 Operation setting
859 )))|(% style="text-align:center; vertical-align:middle" %)Effective immediately|(% style="text-align:center; vertical-align:middle" %)100|(% style="text-align:center; vertical-align:middle" %)0 to 100|(% style="text-align:center; vertical-align:middle" %)Vibration suppression|(% style="text-align:center; vertical-align:middle" %)-
860
861 (% class="table-bordered" %)
862 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**P04-10**|(% style="text-align:center; vertical-align:middle" %)**Parameter name**|(% style="text-align:center; vertical-align:middle" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
863 |(% style="text-align:center; vertical-align:middle" %)2nd notch filter width|(% style="text-align:center; vertical-align:middle" %)(((
864 Operation setting
865 )))|(% style="text-align:center; vertical-align:middle" %)Effective immediately|(% style="text-align:center; vertical-align:middle" %)4|(% style="text-align:center; vertical-align:middle" %)0 to 12|(% style="text-align:center; vertical-align:middle" %)Vibration suppression|(% style="text-align:center; vertical-align:middle" %)-
866
867 = **Group P05 Signal input and output** =
868
869 (% class="table-bordered" %)
870 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**P05-01☆**|(% style="text-align:center; vertical-align:middle" %)**Parameter name**|(% style="text-align:center; vertical-align:middle" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
871 |(% style="text-align:center; vertical-align:middle" %)AI_1 input bias|(% style="text-align:center; vertical-align:middle" %)Operation setting|(% style="text-align:center; vertical-align:middle" %)Effective immediately|(% style="text-align:center; vertical-align:middle" %)0|(% style="text-align:center; vertical-align:middle" %)-5000 to 5000|(% style="text-align:center; vertical-align:middle" %)Analog input|(% style="text-align:center; vertical-align:middle" %)mV
872 |(% colspan="8" style="text-align:center; vertical-align:middle" %)(((
873 Set AI_1 channel analog bias value
874
875 [[image:image-20220608160946-7.png]]
876
877 “☆” indicates that the VD2F servo drive does not support this function code.
878 )))
879
880 (% class="table-bordered" %)
881 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**P05-02☆**|(% style="text-align:center; vertical-align:middle" %)**Parameter name**|(% style="text-align:center; vertical-align:middle" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
882 |(% style="text-align:center; vertical-align:middle" %)AI_1 input filter time constant|(% style="text-align:center; vertical-align:middle" %)Operation setting|(% style="text-align:center; vertical-align:middle" %)Effective immediately|(% style="text-align:center; vertical-align:middle" %)200|(% style="text-align:center; vertical-align:middle" %)0 to 60000|(% style="text-align:center; vertical-align:middle" %)Analog input|(% style="text-align:center; vertical-align:middle" %)0.01ms
883 |(% colspan="8" %)(((
884 Set AI_1 channel input first-order low-pass filter time constant
885
886 “☆” indicates that the VD2F servo drive does not support this function code.
887 )))
888
889 (% class="table-bordered" %)
890 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**P05-03☆**|(% style="text-align:center; vertical-align:middle" %)**Parameter name**|(% style="text-align:center; vertical-align:middle" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
891 |(% style="text-align:center; vertical-align:middle" %)AI_1 dead zone|(% style="text-align:center; vertical-align:middle" %)Operation setting|(% style="text-align:center; vertical-align:middle" %)Effective immediately|(% style="text-align:center; vertical-align:middle" %)20|(% style="text-align:center; vertical-align:middle" %)0 to 1000|(% style="text-align:center; vertical-align:middle" %)Analog input|(% style="text-align:center; vertical-align:middle" %)mV
892 |(% colspan="8" style="text-align:center; vertical-align:middle" %)(((
893 Set AI_1 channel analog quantity dead zone value. “Dead zone” is the input voltage interval when the sample voltage is 0.
894
895 [[image:image-20220608161112-8.png]]
896
897 “☆” indicates that the VD2F servo drive does not support this function code.
898 )))
899
900 (% class="table-bordered" %)
901 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**P05-04☆**|(% style="text-align:center; vertical-align:middle" %)**Parameter name**|(% style="text-align:center; vertical-align:middle" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
902 |(% style="text-align:center; vertical-align:middle" %)AI_1 zero drift|(% style="text-align:center; vertical-align:middle" %)Operation setting|(% style="text-align:center; vertical-align:middle" %)Effective immediately|(% style="text-align:center; vertical-align:middle" %)0|(% style="text-align:center; vertical-align:middle" %)-500 to 500|(% style="text-align:center; vertical-align:middle" %)Analog input|(% style="text-align:center; vertical-align:middle" %)mV
903 |(% colspan="8" style="text-align:center; vertical-align:middle" %)(((
904 Set the zero drift of AI_1 channel analog. “zero drift” is the sample voltage co voltage relative to GND when analog channel voltage is 0.
905
906 [[image:image-20220608161203-9.png]]
907
908 “☆” indicates that the VD2F servo drive does not support this function code.
909 )))
910
911 (% class="table-bordered" %)
912 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**P05-05☆**|(% style="text-align:center; vertical-align:middle" %)**Parameter name**|(% style="text-align:center; vertical-align:middle" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
913 |(% style="text-align:center; vertical-align:middle" %)AI_2 input bias|(% style="text-align:center; vertical-align:middle" %)Operation setting|(% style="text-align:center; vertical-align:middle" %)Effective immediately|(% style="text-align:center; vertical-align:middle" %)0|(% style="text-align:center; vertical-align:middle" %)-5000 to 5000|(% style="text-align:center; vertical-align:middle" %)Analog input|(% style="text-align:center; vertical-align:middle" %)mV
914 |(% colspan="8" %)“☆” indicates that the VD2F servo drive does not support this function code.
915
916 (% class="table-bordered" %)
917 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**P05-06☆**|(% style="text-align:center; vertical-align:middle; width:254px" %)**Parameter name**|(% style="text-align:center; vertical-align:middle; width:205px" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
918 |(% style="text-align:center; vertical-align:middle; width:254px" %)AI_2 input filter time constant|(% style="text-align:center; vertical-align:middle; width:205px" %)Operation setting|(% style="text-align:center; vertical-align:middle" %)Effective immediately|(% style="text-align:center; vertical-align:middle" %)200|(% style="text-align:center; vertical-align:middle" %)0 to 60000|(% style="text-align:center; vertical-align:middle" %)Analog input|(% style="text-align:center; vertical-align:middle" %)0.01ms
919 |(% colspan="8" %)“☆” indicates that the VD2F servo drive does not support this function code.
920
921 (% class="table-bordered" %)
922 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**P05-07☆**|(% style="text-align:center; vertical-align:middle" %)**Parameter name**|(% style="text-align:center; vertical-align:middle" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
923 |(% style="text-align:center; vertical-align:middle" %)AI_2 dead zone|(% style="text-align:center; vertical-align:middle" %)Operation setting|(% style="text-align:center; vertical-align:middle" %)Effective immediately|(% style="text-align:center; vertical-align:middle" %)20|(% style="text-align:center; vertical-align:middle" %)0 to 500|(% style="text-align:center; vertical-align:middle" %)Analog input|(% style="text-align:center; vertical-align:middle" %)mV
924 |(% colspan="8" %)“☆” indicates that the VD2F servo drive does not support this function code.
925
926 (% class="table-bordered" %)
927 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**P05-08☆**|(% style="text-align:center; vertical-align:middle" %)**Parameter name**|(% style="text-align:center; vertical-align:middle" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
928 |(% style="text-align:center; vertical-align:middle" %)AI_2 zero drift|(% style="text-align:center; vertical-align:middle" %)Operation setting|(% style="text-align:center; vertical-align:middle" %)Effective immediately|(% style="text-align:center; vertical-align:middle" %)0|(% style="text-align:center; vertical-align:middle" %)-500 to 500|(% style="text-align:center; vertical-align:middle" %)Analog input|(% style="text-align:center; vertical-align:middle" %)mV
929 |(% colspan="8" %)“☆” indicates that the VD2F servo drive does not support this function code.
930
931 (% class="table-bordered" %)
932 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**P05-09☆**|(% style="text-align:center; vertical-align:middle" %)**Parameter name**|(% style="text-align:center; vertical-align:middle" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
933 |(% style="text-align:center; vertical-align:middle" %)Analog 10V corresponds to the speed value|(% style="text-align:center; vertical-align:middle" %)Shutdown setting|(% style="text-align:center; vertical-align:middle" %)Effective immediately|(% style="text-align:center; vertical-align:middle" %)3000|(% style="text-align:center; vertical-align:middle" %)1000 to 4500|(% style="text-align:center; vertical-align:middle" %)Analog input|(% style="text-align:center; vertical-align:middle" %)rpm
934 |(% colspan="8" %)(((
935 Set the speed value corresponding to the analog 10V
936
937 (% class="table-bordered" %)
938 |(% style="text-align:center; vertical-align:middle" %)**Mode**|(% style="text-align:center; vertical-align:middle" %)**Function code value**|(% style="text-align:center; vertical-align:middle" %)**Sampling voltage and speed diagram**
939 |(% style="text-align:center; vertical-align:middle" %)Speed mode|(% style="text-align:center; vertical-align:middle" %)P01-01=1|(% style="text-align:center; vertical-align:middle" %)[[image:image-20220608161505-10.png]]
940
941 Given speed = sampling voltage / 10 * (P05-09)
942
943 “☆” indicates that the VD2F servo drive does not support this function code.
944 )))
945
946 (% class="table-bordered" %)
947 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**P05-10☆**|(% style="text-align:center; vertical-align:middle" %)**Parameter name**|(% style="text-align:center; vertical-align:middle" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
948 |(% style="text-align:center; vertical-align:middle" %)Analog 10V corresponds to the torque value|(% style="text-align:center; vertical-align:middle" %)Shutdown setting|(% style="text-align:center; vertical-align:middle" %)Effective immediately|(% style="text-align:center; vertical-align:middle" %)1000|(% style="text-align:center; vertical-align:middle" %)0 to 3000|(% style="text-align:center; vertical-align:middle" %)Analog input|(% style="text-align:center; vertical-align:middle" %)0.1%
949 |(% colspan="8" %)(((
950 Set the torque value corresponding to the analog 10V
951
952 (% class="table-bordered" %)
953 |(% style="text-align:center; vertical-align:middle" %)**Mode**|(% style="text-align:center; vertical-align:middle" %)**Function code value**|(% style="text-align:center; vertical-align:middle" %)**Sampling voltage and speed diagram**
954 |(% style="text-align:center; vertical-align:middle" %)Torque mode|(% style="text-align:center; vertical-align:middle" %)P01-07=1|(% style="text-align:center; vertical-align:middle" %)[[image:image-20220608161825-11.png]]
955
956 Given torque= sampling voltage / 10 * (P05-09)
957
958 “☆” indicates that the VD2F servo drive does not support this function code.
959 )))
960
961 (% class="table-bordered" %)
962 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**P05-11**|(% style="text-align:center; vertical-align:middle" %)**Parameter name**|(% style="text-align:center; vertical-align:middle" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
963 |(% style="text-align:center; vertical-align:middle" %)Positioning completion, positioning approach condition setting|(% style="text-align:center; vertical-align:middle" %)Operation setting|(% style="text-align:center; vertical-align:middle" %)Effective immediately|(% style="text-align:center; vertical-align:middle" %)0|(% style="text-align:center; vertical-align:middle" %)0 to 3|(% style="text-align:center; vertical-align:middle" %)Position mode|(% style="text-align:center; vertical-align:middle" %)-
964 |(% colspan="8" %)(((
965 Set the conditions of setting positioning completion and positioning approach. When servo is in position mode, and the absolute value of the positional deviation is within the range of P05-12 (positioning complete threshold) or P05-13 (positioning approach threshold), servo would output the positioning complete signal and positioning approach signal.
966
967 (% class="table-bordered" %)
968 |(% style="text-align:center; vertical-align:middle; width:88px" %)**Set value**|(% style="text-align:center; vertical-align:middle; width:1095px" %)**Output condition**
969 |(% style="text-align:center; vertical-align:middle; width:88px" %)0|(% style="width:1095px" %)It is valid when the absolute value of the position deviation is smaller than or close to the threshold
970 |(% style="text-align:center; vertical-align:middle; width:88px" %)1|(% style="width:1095px" %)It is valid when the absolute value of the position deviation is smaller than or close to the threshold and input position instruction is 0
971 |(% style="text-align:center; vertical-align:middle; width:88px" %)2|(% style="width:1095px" %)It is valid when the absolute value of the position deviation is smaller than or close to the threshold and input position instruction filtering value is 0
972 |(% style="text-align:center; vertical-align:middle; width:88px" %)3|(% style="width:1095px" %)It is valid when the absolute value of the position deviation is smaller than or close to the threshold, input position instruction filtering value is 0, and continuous positioning detects window time
973
974 Given torque= sampling voltage / 10 * (P05-09)
975
976 “☆” indicates that the VD2F servo drive does not support this function code.
977 )))
978
979 (% class="table-bordered" %)
980 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**P05-12**|(% style="text-align:center; vertical-align:middle" %)**Parameter name**|(% style="text-align:center; vertical-align:middle" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
981 |(% style="text-align:center; vertical-align:middle" %)Positioning completion threshold|(% style="text-align:center; vertical-align:middle" %)Operation setting|(% style="text-align:center; vertical-align:middle" %)Effective immediately|(% style="text-align:center; vertical-align:middle" %)800|(% style="text-align:center; vertical-align:middle" %)1 to 65535|(% style="text-align:center; vertical-align:middle" %)Position mode|(% style="text-align:center; vertical-align:middle" %)Equivalent pulse unit
982 |(% colspan="8" %)Set the threshold of absolute value of position deviation when servo drive output positioning completion signal
983
984 (% class="table-bordered" %)
985 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**P05-13**|(% style="text-align:center; vertical-align:middle" %)**Parameter name**|(% style="text-align:center; vertical-align:middle" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
986 |(% style="text-align:center; vertical-align:middle" %)Positioning approach threshold|(% style="text-align:center; vertical-align:middle" %)Operation setting|(% style="text-align:center; vertical-align:middle" %)Effective immediately|(% style="text-align:center; vertical-align:middle" %)5000|(% style="text-align:center; vertical-align:middle" %)1 to 65535|(% style="text-align:center; vertical-align:middle" %)Position mode|(% style="text-align:center; vertical-align:middle" %)Equivalent pulse unit
987 |(% colspan="8" %)Set the threshold of absolute value of position deviation when servo drive output positioning approach signal
988
989 (% class="table-bordered" %)
990 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**P05-14**|(% style="text-align:center; vertical-align:middle; width:262px" %)**Parameter name**|(% style="text-align:center; vertical-align:middle; width:179px" %)**Setting method**|(% style="text-align:center; vertical-align:middle; width:222px" %)**Effective time**|(% style="text-align:center; vertical-align:middle; width:120px" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
991 |(% style="text-align:center; vertical-align:middle; width:262px" %)Position detection window time|(% style="text-align:center; vertical-align:middle; width:179px" %)Operation setting|(% style="text-align:center; vertical-align:middle; width:222px" %)Effective immediately|(% style="text-align:center; vertical-align:middle; width:120px" %)10|(% style="text-align:center; vertical-align:middle" %)0 to 20000|(% style="text-align:center; vertical-align:middle" %)Position mode|(% style="text-align:center; vertical-align:middle" %)ms
992 |(% colspan="8" %)Set the detection window time for positioning completion
993
994 (% class="table-bordered" %)
995 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**P05-15**|(% style="text-align:center; vertical-align:middle" %)**Parameter name**|(% style="text-align:center; vertical-align:middle" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
996 |(% style="text-align:center; vertical-align:middle" %)Positioning signal holding time|(% style="text-align:center; vertical-align:middle" %)Operation setting|(% style="text-align:center; vertical-align:middle" %)Effective immediately|(% style="text-align:center; vertical-align:middle" %)100|(% style="text-align:center; vertical-align:middle" %)0 to 20000|(% style="text-align:center; vertical-align:middle" %)Position mode|(% style="text-align:center; vertical-align:middle" %)ms
997 |(% colspan="8" %)Set the time for the signal to remain in effect after positioning when P05-11=3 (Positioning completion and positioning approach condition setting)
998
999 (% class="table-bordered" %)
1000 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**P05-16**|(% style="text-align:center; vertical-align:middle" %)**Parameter name**|(% style="text-align:center; vertical-align:middle" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
1001 |(% style="text-align:center; vertical-align:middle" %)Rotation detection speed threshold|(% style="text-align:center; vertical-align:middle" %)Operation setting|(% style="text-align:center; vertical-align:middle" %)Effective immediately|(% style="text-align:center; vertical-align:middle" %)20|(% style="text-align:center; vertical-align:middle" %)0 to 1000|(% style="text-align:center; vertical-align:middle" %)Speed mode|(% style="text-align:center; vertical-align:middle" %)rpm
1002 |(% colspan="8" %)Set the speed threshold that triggers the motor rotation signal. The motor rotation signal (TGON) is used to confirm that the motor has rotated. Please refer to __[[6.3.5 Speed-related DO output function>>http://13.229.109.52:8080/wiki/servo/view/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/06%20Operation/#HSpeed-relatedDOoutputfunction]]__
1003
1004 (% class="table-bordered" %)
1005 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**P05-17**|(% style="text-align:center; vertical-align:middle" %)**Parameter name**|(% style="text-align:center; vertical-align:middle" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
1006 |(% style="text-align:center; vertical-align:middle" %)Speed consistent signal threshold|(% style="text-align:center; vertical-align:middle" %)Operation setting|(% style="text-align:center; vertical-align:middle" %)Effective immediately|(% style="text-align:center; vertical-align:middle" %)10|(% style="text-align:center; vertical-align:middle" %)0 to 100|(% style="text-align:center; vertical-align:middle" %)Speed mode|rpm
1007 |(% colspan="8" %)Set the speed threshold that triggers the motor speed consistent signal. The motor outputs speed consistent signal (V-COIN) indicates that the actual speed has reached the speed instruction setting value. Please refer to __[[6.3.5 Speed-related DO output function>>http://13.229.109.52:8080/wiki/servo/view/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/06%20Operation/#HSpeed-relatedDOoutputfunction]]__
1008
1009 (% class="table-bordered" %)
1010 |(% rowspan="2" style="text-align:center; vertical-align:middle; width:84px" %)**P05-18**|(% style="text-align:center; vertical-align:middle; width:316px" %)**Parameter name**|(% style="text-align:center; vertical-align:middle" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
1011 |(% style="text-align:center; vertical-align:middle; width:316px" %)Speed approach signal threshold|(% style="text-align:center; vertical-align:middle" %)Operation setting|(% style="text-align:center; vertical-align:middle" %)Effective immediately|(% style="text-align:center; vertical-align:middle" %)100|(% style="text-align:center; vertical-align:middle" %)10 to 6000|(% style="text-align:center; vertical-align:middle" %)Speed mode|(% style="text-align:center; vertical-align:middle" %)rpm
1012 |(% colspan="8" %)Set the speed threshold that triggers the motor speed approach signal. The motor outputs speed approach signal (V-NEAR) indicates that the actual speed has reached the expected value. Please refer to __[[6.3.5 Speed-related DO output function>>http://13.229.109.52:8080/wiki/servo/view/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/06%20Operation/#HSpeed-relatedDOoutputfunction]]__
1013
1014 (% class="table-bordered" %)
1015 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**P05-19**|(% style="text-align:center; vertical-align:middle" %)**Parameter name**|(% style="text-align:center; vertical-align:middle" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
1016 |(% style="text-align:center; vertical-align:middle" %)Zero speed output signal threshold|(% style="text-align:center; vertical-align:middle" %)Operation setting|(% style="text-align:center; vertical-align:middle" %)Effective immediately|(% style="text-align:center; vertical-align:middle" %)10|(% style="text-align:center; vertical-align:middle" %)0 to 6000|(% style="text-align:center; vertical-align:middle" %)Speed mode|(% style="text-align:center; vertical-align:middle" %)rpm
1017 |(% colspan="8" %)Set the speed threshold that triggers the motor zero speed output signal. The motor outputs zero speed signal (ZSP) indicates that the actual speed is almost stationary. Please refer to __[[6.3.5 Speed-related DO output function>>http://13.229.109.52:8080/wiki/servo/view/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/06%20Operation/#HSpeed-relatedDOoutputfunction]]__
1018
1019 (% class="table-bordered" %)
1020 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**P05-20**|(% style="text-align:center; vertical-align:middle" %)**Parameter name**|(% style="text-align:center; vertical-align:middle" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
1021 |(% style="text-align:center; vertical-align:middle" %)Torque arrival threshold|(% style="text-align:center; vertical-align:middle" %)Operation setting|(% style="text-align:center; vertical-align:middle" %)Effective immediately|(% style="text-align:center; vertical-align:middle" %)100|(% style="text-align:center; vertical-align:middle" %)0 to 300|(% style="text-align:center; vertical-align:middle" %)Torque mode|(% style="text-align:center; vertical-align:middle" %)%
1022 |(% colspan="8" %)Please refer to __[[6.4.5 Torque-related DO output functions>>http://13.229.109.52:8080/wiki/servo/view/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/06%20Operation/#HTorque-relatedDOoutputfunctions]]__
1023
1024 (% class="table-bordered" %)
1025 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**P05-21**|(% style="text-align:center; vertical-align:middle" %)**Parameter name**|(% style="text-align:center; vertical-align:middle" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
1026 |(% style="text-align:center; vertical-align:middle" %)Torque arrival hysteresis value|(% style="text-align:center; vertical-align:middle" %)Operation setting|(% style="text-align:center; vertical-align:middle" %)Effective immediately|(% style="text-align:center; vertical-align:middle" %)10|(% style="text-align:center; vertical-align:middle" %)0 to 20|(% style="text-align:center; vertical-align:middle" %)Torque mode|(% style="text-align:center; vertical-align:middle" %)%
1027 |(% colspan="8" %)Please refer to __[[6.4.5 Torque-related DO output functions>>http://13.229.109.52:8080/wiki/servo/view/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/06%20Operation/#HTorque-relatedDOoutputfunctions]]__
1028
1029 = **Group P06 DI/DO configuration** =
1030
1031 (% class="table-bordered" %)
1032 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**P06-02**|(% style="text-align:center; vertical-align:middle" %)**Parameter name**|(% style="text-align:center; vertical-align:middle" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
1033 |(% style="text-align:center; vertical-align:middle" %)DI_1 channel function selection|(% style="text-align:center; vertical-align:middle" %)Operation setting|(% style="text-align:center; vertical-align:middle" %)Power on again|(% style="text-align:center; vertical-align:middle" %)01|(% style="text-align:center; vertical-align:middle" %)0 to 32|(% style="text-align:center; vertical-align:middle" %)DI/DO|(% style="text-align:center; vertical-align:middle" %)-
1034 |(% colspan="8" %)(((
1035 Set DI functions corresponding to hardware DI_1. The related functions are as below.
1036
1037 (% class="table-bordered" %)
1038 |(% style="text-align:center; vertical-align:middle" %)**Set value**|(% style="text-align:center; vertical-align:middle" %)**DI channel function**|(% style="text-align:center; vertical-align:middle" %)**Set value**|(% style="text-align:center; vertical-align:middle" %)**DI channel function**
1039 |(% style="text-align:center; vertical-align:middle" %)0|Off (not used)|(% style="text-align:center; vertical-align:middle" %)13|INSPD1 (Internal speed instruction selection 1)
1040 |(% style="text-align:center; vertical-align:middle" %)1|S-ON (Servo enable)|(% style="text-align:center; vertical-align:middle" %)14|INSPD2 (Internal speed instruction selection 2)
1041 |(% style="text-align:center; vertical-align:middle" %)2|A-CLR (Fault and warning clear)|(% style="text-align:center; vertical-align:middle" %)15|INSPD3 (Internal speed instruction selection 3)
1042 |(% style="text-align:center; vertical-align:middle" %)3|POT (Forward drive prohibition)|(% style="text-align:center; vertical-align:middle" %)16|J-SEL Inertia ratio switch (not implemented yet)
1043 |(% style="text-align:center; vertical-align:middle" %)4|NOT (Reverse drive prohibition)|(% style="text-align:center; vertical-align:middle" %)17|MixModeSel Mix mode selection
1044 |(% style="text-align:center; vertical-align:middle" %)5|ZCLAMP (Zero-speed clamp)|(% style="text-align:center; vertical-align:middle" %)18|None
1045 |(% style="text-align:center; vertical-align:middle" %)6|CL (Clear deviation counter)|(% style="text-align:center; vertical-align:middle" %)19|None
1046 |(% style="text-align:center; vertical-align:middle" %)7|C-SIGN (instruction is reversed)|(% style="text-align:center; vertical-align:middle" %)20|ENINPOS (Internal multi-segment enable signal)
1047 |(% style="text-align:center; vertical-align:middle" %)8|E-STOP (Emergency stop)|(% style="text-align:center; vertical-align:middle" %)21|(((
1048 INPOS1
1049
1050 (Internal multi-segment position selection 1)
1051 )))
1052 |(% style="text-align:center; vertical-align:middle" %)9|GEAR-SEL (Electronic Gear Switch 1)|(% style="text-align:center; vertical-align:middle" %)22|(((
1053 INPOS2
1054
1055 (Internal multi-segment position selection 2)
1056 )))
1057 |(% style="text-align:center; vertical-align:middle" %)10|GAIN-SEL (Gain switch)|(% style="text-align:center; vertical-align:middle" %)23|(((
1058 INPOS3
1059
1060 (Internal multi-segment position selection 3)
1061 )))
1062 |(% style="text-align:center; vertical-align:middle" %)11|INH (Instruction pulse prohibited input)|(% style="text-align:center; vertical-align:middle" %)24|(((
1063 INPOS4
1064
1065 (Internal multi-segment position selection 4)
1066 )))
1067 |(% style="text-align:center; vertical-align:middle" %)12|VSSEL (Vibration control switching input)|(% style="text-align:center; vertical-align:middle" %)-|-
1068
1069 If P06-02 is set to a value other than that in the preceding table, the DI port function is not require
1070
1071 The same DI channel function could not be allocated to multiple DI ports, otherwise servo drive will occur A-89 (DI port configuration duplication)
1072 )))
1073
1074 (% class="table-bordered" %)
1075 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**P06-03**|(% style="text-align:center; vertical-align:middle" %)**Parameter name**|(% style="text-align:center; vertical-align:middle" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
1076 |(% style="text-align:center; vertical-align:middle" %)DI_1 channel logic selection|(% style="text-align:center; vertical-align:middle" %)Operation setting|(% style="text-align:center; vertical-align:middle" %)Effective immediately|(% style="text-align:center; vertical-align:middle" %)0|(% style="text-align:center; vertical-align:middle" %)0 to 1|(% style="text-align:center; vertical-align:middle" %)DI/DO|(% style="text-align:center; vertical-align:middle" %)-
1077 |(% colspan="8" %)DI port input logic validity function selection(((
1078 (% class="table-bordered" %)
1079 |(% style="text-align:center; vertical-align:middle" %)**Set value**|(% style="text-align:center; vertical-align:middle" %)**Content**|(% style="text-align:center; vertical-align:middle" %)**Illustration**
1080 |(% style="text-align:center; vertical-align:middle" %)0|(% style="text-align:center; vertical-align:middle" %)(((
1081 Normally open input.
1082
1083 Active low level (switch on)
1084 )))|(% style="text-align:center; vertical-align:middle" %)[[image:image-20220608161925-12.png]]
1085 |(% style="text-align:center; vertical-align:middle" %)1|(% style="text-align:center; vertical-align:middle" %)(((
1086 Normally closed input.
1087
1088 Active high level (switch off)
1089 )))|(% style="text-align:center; vertical-align:middle" %)[[image:image-20220608162007-13.png]]
1090 )))
1091
1092 (% class="table-bordered" %)
1093 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**P06-04**|(% style="text-align:center; vertical-align:middle" %)**Parameter name**|(% style="text-align:center; vertical-align:middle" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
1094 |(% style="text-align:center; vertical-align:middle" %)DI_1 input source selection|(% style="text-align:center; vertical-align:middle" %)Operation setting|(% style="text-align:center; vertical-align:middle" %)Effective immediately|(% style="text-align:center; vertical-align:middle" %)0|(% style="text-align:center; vertical-align:middle" %)0 to 1|(% style="text-align:center; vertical-align:middle" %)DI/DO|(% style="text-align:center; vertical-align:middle" %)-
1095 |(% colspan="8" %)Select the enabled DI_1 port type(((
1096 (% class="table-bordered" %)
1097 |(% style="text-align:center; vertical-align:middle" %)**Set value**|(% style="text-align:center; vertical-align:middle" %)**Content**
1098 |(% style="text-align:center; vertical-align:middle" %)0|Hardware DI_1 input terminal
1099 |(% style="text-align:center; vertical-align:middle" %)1|Virtual VDI_1 input terminal
1100 )))
1101
1102 (% class="table-bordered" %)
1103 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**P06-05**|(% style="text-align:center; vertical-align:middle; width:293px" %)**Parameter name**|(% style="text-align:center; vertical-align:middle; width:198px" %)**Setting method**|(% style="text-align:center; vertical-align:middle; width:227px" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
1104 |(% style="text-align:center; vertical-align:middle; width:293px" %)DI_2 channel function selection|(% style="text-align:center; vertical-align:middle; width:198px" %)Operation setting|(% style="text-align:center; vertical-align:middle; width:227px" %)Power on again|(% style="text-align:center; vertical-align:middle" %)2|(% style="text-align:center; vertical-align:middle" %)0 to 32|(% style="text-align:center; vertical-align:middle" %)DI/DO|(% style="text-align:center; vertical-align:middle" %)-
1105
1106 (% class="table-bordered" %)
1107 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**P06-06**|(% style="text-align:center; vertical-align:middle" %)**Parameter name**|(% style="text-align:center; vertical-align:middle" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
1108 |(% style="text-align:center; vertical-align:middle" %)DI_2 channel logic selection|(% style="text-align:center; vertical-align:middle" %)Operation setting|(% style="text-align:center; vertical-align:middle" %)Effective immediately|(% style="text-align:center; vertical-align:middle" %)0|(% style="text-align:center; vertical-align:middle" %)0 to 1|(% style="text-align:center; vertical-align:middle" %)DI/DO|(% style="text-align:center; vertical-align:middle" %)-
1109
1110 (% class="table-bordered" %)
1111 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**P06-07**|(% style="text-align:center; vertical-align:middle" %)**Parameter name**|(% style="text-align:center; vertical-align:middle" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
1112 |(% style="text-align:center; vertical-align:middle" %)DI_2 input source selection|(% style="text-align:center; vertical-align:middle" %)Operation setting|(% style="text-align:center; vertical-align:middle" %)Effective immediately|(% style="text-align:center; vertical-align:middle" %)0|(% style="text-align:center; vertical-align:middle" %)0 to 1|(% style="text-align:center; vertical-align:middle" %)DI/DO|(% style="text-align:center; vertical-align:middle" %)-
1113
1114 (% class="table-bordered" %)
1115 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**P06-08**|(% style="text-align:center; vertical-align:middle; width:287px" %)**Parameter name**|(% style="text-align:center; vertical-align:middle; width:203px" %)**Setting method**|(% style="text-align:center; vertical-align:middle; width:228px" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
1116 |(% style="text-align:center; vertical-align:middle; width:287px" %)DI_3 channel function selection|(% style="text-align:center; vertical-align:middle; width:203px" %)Operation setting|(% style="text-align:center; vertical-align:middle; width:228px" %)Power on again|(% style="text-align:center; vertical-align:middle" %)3|(% style="text-align:center; vertical-align:middle" %)0 to 32|(% style="text-align:center; vertical-align:middle" %)DI/DO|(% style="text-align:center; vertical-align:middle" %)-
1117
1118 (% class="table-bordered" %)
1119 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**P06-09**|(% style="text-align:center; vertical-align:middle" %)**Parameter name**|(% style="text-align:center; vertical-align:middle" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
1120 |(% style="text-align:center; vertical-align:middle" %)DI_3 channel logic selection|(% style="text-align:center; vertical-align:middle" %)Operation setting|(% style="text-align:center; vertical-align:middle" %)Effective immediately|(% style="text-align:center; vertical-align:middle" %)0|(% style="text-align:center; vertical-align:middle" %)0 to 1|(% style="text-align:center; vertical-align:middle" %)DI/DO|(% style="text-align:center; vertical-align:middle" %)-
1121
1122 (% class="table-bordered" %)
1123 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**P06-10**|(% style="text-align:center; vertical-align:middle" %)**Parameter name**|(% style="text-align:center; vertical-align:middle" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
1124 |(% style="text-align:center; vertical-align:middle" %)DI_3 input source selection|(% style="text-align:center; vertical-align:middle" %)Operation setting|(% style="text-align:center; vertical-align:middle" %)Effective immediately|(% style="text-align:center; vertical-align:middle" %)0|(% style="text-align:center; vertical-align:middle" %)0 to 1|(% style="text-align:center; vertical-align:middle" %)DI/DO|(% style="text-align:center; vertical-align:middle" %)-
1125
1126 (% class="table-bordered" %)
1127 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**P06-11**|(% style="text-align:center; vertical-align:middle; width:292px" %)**Parameter name**|(% style="text-align:center; vertical-align:middle; width:202px" %)**Setting method**|(% style="text-align:center; vertical-align:middle; width:231px" %)**Effective time**|(% style="text-align:center; vertical-align:middle; width:95px" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
1128 |(% style="text-align:center; vertical-align:middle; width:292px" %)DI_4 channel function selection|(% style="text-align:center; vertical-align:middle; width:202px" %)Operation setting|(% style="text-align:center; vertical-align:middle; width:231px" %)Power on again|(% style="text-align:center; vertical-align:middle; width:95px" %)4|(% style="text-align:center; vertical-align:middle" %)0 to 32|(% style="text-align:center; vertical-align:middle" %)DI/DO|(% style="text-align:center; vertical-align:middle" %)-
1129
1130 (% class="table-bordered" %)
1131 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**P06-12**|(% style="text-align:center; vertical-align:middle" %)**Parameter name**|(% style="text-align:center; vertical-align:middle" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
1132 |(% style="text-align:center; vertical-align:middle" %)DI_4 channel logic selection|(% style="text-align:center; vertical-align:middle" %)Operation setting|(% style="text-align:center; vertical-align:middle" %)Effective immediately|(% style="text-align:center; vertical-align:middle" %)0|(% style="text-align:center; vertical-align:middle" %)0 to 1|(% style="text-align:center; vertical-align:middle" %)DI/DO|(% style="text-align:center; vertical-align:middle" %)-
1133
1134 (% class="table-bordered" %)
1135 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**P06-13**|(% style="text-align:center; vertical-align:middle" %)**Parameter name**|(% style="text-align:center; vertical-align:middle" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
1136 |(% style="text-align:center; vertical-align:middle" %)DI_4 input source selection|(% style="text-align:center; vertical-align:middle" %)Operation setting|(% style="text-align:center; vertical-align:middle" %)Effective immediately|(% style="text-align:center; vertical-align:middle" %)0|(% style="text-align:center; vertical-align:middle" %)0 to 1|(% style="text-align:center; vertical-align:middle" %)DI/DO|(% style="text-align:center; vertical-align:middle" %)-
1137
1138 (% class="table-bordered" %)
1139 |(% rowspan="2" style="text-align:center; vertical-align:middle; width:94px" %)**P06-14☆**|(% style="text-align:center; vertical-align:middle; width:297px" %)**Parameter name**|(% style="text-align:center; vertical-align:middle; width:195px" %)**Setting method**|(% style="text-align:center; vertical-align:middle; width:241px" %)**Effective time**|(% style="text-align:center; vertical-align:middle; width:93px" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
1140 |(% style="text-align:center; vertical-align:middle; width:297px" %)DI_5 channel function selection|(% style="text-align:center; vertical-align:middle; width:195px" %)Operation setting|(% style="text-align:center; vertical-align:middle; width:241px" %)Power on again|(% style="text-align:center; vertical-align:middle; width:93px" %)7|(% style="text-align:center; vertical-align:middle" %)0 to 32|(% style="text-align:center; vertical-align:middle" %)DI/DO|(% style="text-align:center; vertical-align:middle" %)-
1141
1142 “☆” indicates that the VD2F servo drive does not support this function code.
1143
1144 (% class="table-bordered" %)
1145 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**P06-15☆**|(% style="text-align:center; vertical-align:middle; width:286px" %)**Parameter name**|(% style="text-align:center; vertical-align:middle; width:199px" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
1146 |(% style="text-align:center; vertical-align:middle; width:286px" %)DI_5 channel logic selection|(% style="text-align:center; vertical-align:middle; width:199px" %)Operation setting|(% style="text-align:center; vertical-align:middle" %)Effective immediately|(% style="text-align:center; vertical-align:middle" %)0|(% style="text-align:center; vertical-align:middle" %)0 to 1|(% style="text-align:center; vertical-align:middle" %)DI/DO|(% style="text-align:center; vertical-align:middle" %)-
1147
1148 “☆” indicates that the VD2F servo drive does not support this function code.
1149
1150 (% class="table-bordered" %)
1151 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**P06-16☆**|(% style="text-align:center; vertical-align:middle" %)**Parameter name**|(% style="text-align:center; vertical-align:middle" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
1152 |(% style="text-align:center; vertical-align:middle" %)DI_5 input source selection|(% style="text-align:center; vertical-align:middle" %)Operation setting|(% style="text-align:center; vertical-align:middle" %)Effective immediately|(% style="text-align:center; vertical-align:middle" %)0|(% style="text-align:center; vertical-align:middle" %)0 to 1|(% style="text-align:center; vertical-align:middle" %)DI/DO|(% style="text-align:center; vertical-align:middle" %)-
1153
1154 “☆” indicates that the VD2F servo drive does not support this function code.
1155
1156 (% class="table-bordered" %)
1157 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**P06-17☆**|(% style="text-align:center; vertical-align:middle; width:288px" %)**Parameter name**|(% style="text-align:center; vertical-align:middle; width:195px" %)**Setting method**|(% style="text-align:center; vertical-align:middle; width:230px" %)**Effective time**|(% style="text-align:center; vertical-align:middle; width:94px" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
1158 |(% style="text-align:center; vertical-align:middle; width:288px" %)DI_6 channel function selection|(% style="text-align:center; vertical-align:middle; width:195px" %)Operation setting|(% style="text-align:center; vertical-align:middle; width:230px" %)Power on again|(% style="text-align:center; vertical-align:middle; width:94px" %)11|(% style="text-align:center; vertical-align:middle" %)0 to 32|(% style="text-align:center; vertical-align:middle" %)DI/DO|(% style="text-align:center; vertical-align:middle" %)-
1159
1160 “☆” indicates that the VD2F servo drive does not support this function code.
1161
1162 (% class="table-bordered" %)
1163 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**P06-18☆**|(% style="text-align:center; vertical-align:middle" %)**Parameter name**|(% style="text-align:center; vertical-align:middle" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
1164 |(% style="text-align:center; vertical-align:middle" %)DI_6 channel logic selection|(% style="text-align:center; vertical-align:middle" %)Operation setting|(% style="text-align:center; vertical-align:middle" %)Effective immediately|(% style="text-align:center; vertical-align:middle" %)0|(% style="text-align:center; vertical-align:middle" %)0 to 1|(% style="text-align:center; vertical-align:middle" %)DI/DO|(% style="text-align:center; vertical-align:middle" %)-
1165
1166 “☆” indicates that the VD2F servo drive does not support this function code.
1167
1168 (% class="table-bordered" %)
1169 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**P06-19☆**|(% style="text-align:center; vertical-align:middle" %)**Parameter name**|(% style="text-align:center; vertical-align:middle" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
1170 |(% style="text-align:center; vertical-align:middle" %)DI_6 input source selection|(% style="text-align:center; vertical-align:middle" %)Operation setting|(% style="text-align:center; vertical-align:middle" %)Effective immediately|(% style="text-align:center; vertical-align:middle" %)0|(% style="text-align:center; vertical-align:middle" %)0 to 1|(% style="text-align:center; vertical-align:middle" %)DI/DO|(% style="text-align:center; vertical-align:middle" %)-
1171
1172 “☆” indicates that the VD2F servo drive does not support this function code.
1173
1174 (% class="table-bordered" %)
1175 |(% rowspan="2" style="text-align:center; vertical-align:middle; width:109px" %)**P06-20☆**|(% style="text-align:center; vertical-align:middle; width:294px" %)**Parameter name**|(% style="text-align:center; vertical-align:middle; width:193px" %)**Setting method**|(% style="text-align:center; vertical-align:middle; width:226px" %)**Effective time**|(% style="text-align:center; vertical-align:middle; width:98px" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
1176 |(% style="text-align:center; vertical-align:middle; width:294px" %)DI_7 channel function selection|(% style="text-align:center; vertical-align:middle; width:193px" %)Operation setting|(% style="text-align:center; vertical-align:middle; width:226px" %)Power on again|(% style="text-align:center; vertical-align:middle; width:98px" %)2|(% style="text-align:center; vertical-align:middle" %)0 to 32|(% style="text-align:center; vertical-align:middle" %)DI/DO|(% style="text-align:center; vertical-align:middle" %)-
1177
1178 “☆” indicates that the VD2F servo drive does not support this function code.
1179
1180 (% class="table-bordered" %)
1181 |(% rowspan="2" style="text-align:center; vertical-align:middle; width:111px" %)**P06-21☆**|(% style="text-align:center; vertical-align:middle; width:289px" %)**Parameter name**|(% style="text-align:center; vertical-align:middle; width:199px" %)**Setting method**|(% style="text-align:center; vertical-align:middle; width:223px" %)**Effective time**|(% style="text-align:center; vertical-align:middle; width:94px" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
1182 |(% style="text-align:center; vertical-align:middle; width:289px" %)DI_7 channel logic selection|(% style="text-align:center; vertical-align:middle; width:199px" %)Operation setting|(% style="text-align:center; vertical-align:middle; width:223px" %)Power on again|(% style="text-align:center; vertical-align:middle; width:94px" %)0|(% style="text-align:center; vertical-align:middle" %)0 to 1|(% style="text-align:center; vertical-align:middle" %)DI/DO|(% style="text-align:center; vertical-align:middle" %)-
1183
1184 “☆” indicates that the VD2F servo drive does not support this function code.
1185
1186 (% class="table-bordered" %)
1187 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**P06-22☆**|(% style="text-align:center; vertical-align:middle" %)**Parameter name**|(% style="text-align:center; vertical-align:middle" %)**Setting method**|(% style="text-align:center; vertical-align:middle; width:227px" %)**Effective time**|(% style="text-align:center; vertical-align:middle; width:105px" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
1188 |(% style="text-align:center; vertical-align:middle" %)DI_7 input source selection|(% style="text-align:center; vertical-align:middle" %)Operation setting|(% style="text-align:center; vertical-align:middle; width:227px" %)Effective immediately|(% style="text-align:center; vertical-align:middle; width:105px" %)0|(% style="text-align:center; vertical-align:middle" %)0 to 1|(% style="text-align:center; vertical-align:middle" %)DI/DO|(% style="text-align:center; vertical-align:middle" %)-
1189
1190 “☆” indicates that the VD2F servo drive does not support this function code.
1191
1192 (% class="table-bordered" %)
1193 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**P06-23☆**|(% style="text-align:center; vertical-align:middle; width:292px" %)**Parameter name**|(% style="text-align:center; vertical-align:middle; width:195px" %)**Setting method**|(% style="text-align:center; vertical-align:middle; width:220px" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
1194 |(% style="text-align:center; vertical-align:middle; width:292px" %)DI_8 channel function selection|(% style="text-align:center; vertical-align:middle; width:195px" %)Operation setting|(% style="text-align:center; vertical-align:middle; width:220px" %)Power on again|(% style="text-align:center; vertical-align:middle" %)2|(% style="text-align:center; vertical-align:middle" %)0 to 32|(% style="text-align:center; vertical-align:middle" %)DI/DO|(% style="text-align:center; vertical-align:middle" %)-
1195
1196 “☆” indicates that the VD2F servo drive does not support this function code.
1197
1198 (% class="table-bordered" %)
1199 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**P06-24☆**|(% style="text-align:center; vertical-align:middle; width:290px" %)**Parameter name**|(% style="text-align:center; vertical-align:middle; width:188px" %)**Setting method**|(% style="text-align:center; vertical-align:middle; width:230px" %)**Effective time**|(% style="text-align:center; vertical-align:middle; width:90px" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
1200 |(% style="text-align:center; vertical-align:middle; width:290px" %)DI_8 channel logic selection|(% style="text-align:center; vertical-align:middle; width:188px" %)Operation setting|(% style="text-align:center; vertical-align:middle; width:230px" %)Power on again|(% style="text-align:center; vertical-align:middle; width:90px" %)0|(% style="text-align:center; vertical-align:middle" %)0 to 1|(% style="text-align:center; vertical-align:middle" %)DI/DO|(% style="text-align:center; vertical-align:middle" %)-
1201
1202 “☆” indicates that the VD2F servo drive does not support this function code.
1203
1204 (% class="table-bordered" %)
1205 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**P06-25☆**|(% style="text-align:center; vertical-align:middle" %)**Parameter name**|(% style="text-align:center; vertical-align:middle" %)**Setting method**|(% style="text-align:center; vertical-align:middle; width:221px" %)**Effective time**|(% style="text-align:center; vertical-align:middle; width:111px" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
1206 |(% style="text-align:center; vertical-align:middle" %)DI_8 input source selection|(% style="text-align:center; vertical-align:middle" %)Operation setting|(% style="text-align:center; vertical-align:middle; width:221px" %)Effective immediately|(% style="text-align:center; vertical-align:middle; width:111px" %)0|(% style="text-align:center; vertical-align:middle" %)0 to 1|(% style="text-align:center; vertical-align:middle" %)DI/DO|(% style="text-align:center; vertical-align:middle" %)-
1207
1208 “☆” indicates that the VD2F servo drive does not support this function code.
1209
1210 (% class="table-bordered" %)
1211 |(% rowspan="2" style="text-align:center; vertical-align:middle; width:117px" %)**P06-26**|(% style="text-align:center; vertical-align:middle; width:280px" %)**Parameter name**|(% style="text-align:center; vertical-align:middle; width:194px" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
1212 |(% style="text-align:center; vertical-align:middle; width:280px" %)DO_1 channel function selection|(% style="text-align:center; vertical-align:middle; width:194px" %)Operation setting|(% style="text-align:center; vertical-align:middle" %)Effective immediately|(% style="text-align:center; vertical-align:middle" %)132|(% style="text-align:center; vertical-align:middle" %)128 to 142|(% style="text-align:center; vertical-align:middle" %)DI/DO|(% style="text-align:center; vertical-align:middle" %)-
1213 |(% colspan="8" %)(((
1214 Set DO functions corresponding to hardware DO_1. The related functions are as below.
1215
1216 (% class="table-bordered" %)
1217 |(% style="text-align:center; vertical-align:middle" %)Set value|(% style="text-align:center; vertical-align:middle" %)DO channel function|(% style="text-align:center; vertical-align:middle" %)Set value|(% style="text-align:center; vertical-align:middle" %)DO channel function
1218 |(% style="text-align:center; vertical-align:middle" %)128|(% style="text-align:center; vertical-align:middle" %)Close (not used)|(% style="text-align:center; vertical-align:middle" %)139|(% style="text-align:center; vertical-align:middle" %)T-LIMIT (Torque limit)
1219 |(% style="text-align:center; vertical-align:middle" %)129|(% style="text-align:center; vertical-align:middle" %)RDY (Servo ready)|(% style="text-align:center; vertical-align:middle" %)140|(% style="text-align:center; vertical-align:middle" %)140-V-LIMIT (speed limited)
1220 |(% style="text-align:center; vertical-align:middle" %)130|(% style="text-align:center; vertical-align:middle" %)ALM (fault signal)|(% style="text-align:center; vertical-align:middle" %)141|(% style="text-align:center; vertical-align:middle" %)141-BRK-OFF (brake output)**✎**
1221 |(% style="text-align:center; vertical-align:middle" %)131|(% style="text-align:center; vertical-align:middle" %)WARN (warning signal)|(% style="text-align:center; vertical-align:middle" %)142|(% style="text-align:center; vertical-align:middle" %)142-SRV-ST (Servo on state output)
1222 |(% style="text-align:center; vertical-align:middle" %)132|(% style="text-align:center; vertical-align:middle" %)TGON (rotation detection)|(% style="text-align:center; vertical-align:middle" %)143|(% style="text-align:center; vertical-align:middle" %)OZ (Z pulse output)
1223 |(% style="text-align:center; vertical-align:middle" %)133|(% style="text-align:center; vertical-align:middle" %)ZSP (zero speed signal)|(% style="text-align:center; vertical-align:middle" %)144|(% style="text-align:center; vertical-align:middle" %)None
1224 |(% style="text-align:center; vertical-align:middle" %)134|(% style="text-align:center; vertical-align:middle" %)P-COIN (positioning completed)|(% style="text-align:center; vertical-align:middle" %)145|(% style="text-align:center; vertical-align:middle" %)COM_VDO1 (communication VDO1 output)
1225 |(% style="text-align:center; vertical-align:middle" %)135|(% style="text-align:center; vertical-align:middle" %)P-NEAR (positioning approach)|(% style="text-align:center; vertical-align:middle" %)146|(% style="text-align:center; vertical-align:middle" %)COM_VDO1 (communication VDO2 output)
1226 |(% style="text-align:center; vertical-align:middle" %)136|(% style="text-align:center; vertical-align:middle" %)V-COIN (consistent speed)|(% style="text-align:center; vertical-align:middle" %)147|(% style="text-align:center; vertical-align:middle" %)COM_VDO1 (communication VDO3 output)
1227 |(% style="text-align:center; vertical-align:middle" %)137|(% style="text-align:center; vertical-align:middle" %)V-NEAR (speed approach)|(% style="text-align:center; vertical-align:middle" %)148|(% style="text-align:center; vertical-align:middle" %)COM_VDO1 (communication VDO4 output)
1228 |(% style="text-align:center; vertical-align:middle" %)138|(% style="text-align:center; vertical-align:middle" %)T-COIN (torque arrival)|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)
1229
1230 If P06-26 is set to a value other than that in the preceding table, the DO port function is not required
1231
1232 The same DO channel function could not be allocated to multiple DO ports, otherwise servo drive will occur A-90 (DO port configuration duplication)
1233
1234 “✎” means use the function code BRK-OFF would be effective after power on again.
1235
1236 ✎**Note:** Only VD2F supports 143: OZ (Z pulse output). The function of VD2-0SA1G is empty.
1237 )))
1238
1239 (% class="table-bordered" %)
1240 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**P06-27**|(% style="text-align:center; vertical-align:middle" %)**Parameter name**|(% style="text-align:center; vertical-align:middle" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
1241 |(% style="text-align:center; vertical-align:middle" %)DO_1 channel logic selection|(% style="text-align:center; vertical-align:middle" %)Operation setting|(% style="text-align:center; vertical-align:middle" %)Effective immediately|(% style="text-align:center; vertical-align:middle" %)0|(% style="text-align:center; vertical-align:middle" %)0 to 1|(% style="text-align:center; vertical-align:middle" %)DI/DO|(% style="text-align:center; vertical-align:middle" %)-
1242 |(% colspan="8" %)DO Port input logic validity function selection.(((
1243 (% class="table-bordered" %)
1244 |(% style="text-align:center; vertical-align:middle" %)**Set value**|(% style="text-align:center; vertical-align:middle" %)**Content**
1245 |(% style="text-align:center; vertical-align:middle" %)0|Output transistor is on when the output is valid, and output transistor is off when the output is invalid.
1246 |(% style="text-align:center; vertical-align:middle" %)1|Output transistor is off when the output is valid, and output transistor is on when the output is invalid.
1247 )))
1248
1249 (% class="table-bordered" %)
1250 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**P06-28**|(% style="text-align:center; vertical-align:middle" %)**Parameter name**|(% style="text-align:center; vertical-align:middle" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
1251 |(% style="text-align:center; vertical-align:middle" %)DO_2 channel function selection|(% style="text-align:center; vertical-align:middle" %)Operation setting|(% style="text-align:center; vertical-align:middle" %)Effective immediately|(% style="text-align:center; vertical-align:middle" %)130|(% style="text-align:center; vertical-align:middle" %)128 to 142|(% style="text-align:center; vertical-align:middle" %)DI/DO|(% style="text-align:center; vertical-align:middle" %)-
1252
1253 (% class="table-bordered" %)
1254 |(% rowspan="2" style="text-align:center; vertical-align:middle; width:89px" %)**P06-29**|(% style="text-align:center; vertical-align:middle; width:321px" %)**Parameter name**|(% style="text-align:center; vertical-align:middle; width:183px" %)**Setting method**|(% style="text-align:center; vertical-align:middle; width:218px" %)**Effective time**|(% style="text-align:center; vertical-align:middle; width:96px" %)**Default**|(% style="text-align:center; vertical-align:middle; width:118px" %)**Range**|(% style="text-align:center; vertical-align:middle; width:107px" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
1255 |(% style="text-align:center; vertical-align:middle; width:321px" %)DO_2 channel logic selection|(% style="text-align:center; vertical-align:middle; width:183px" %)Operation setting|(% style="text-align:center; vertical-align:middle; width:218px" %)Effective immediately|(% style="text-align:center; vertical-align:middle; width:96px" %)0|(% style="text-align:center; vertical-align:middle; width:118px" %)0 to 1|(% style="text-align:center; vertical-align:middle; width:107px" %)DI/DO|(% style="text-align:center; vertical-align:middle" %)-
1256
1257 (% class="table-bordered" %)
1258 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**P06-30**|(% style="text-align:center; vertical-align:middle" %)**Parameter name**|(% style="text-align:center; vertical-align:middle" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
1259 |(% style="text-align:center; vertical-align:middle" %)DO_3 channel function selection|(% style="text-align:center; vertical-align:middle" %)Operation setting|(% style="text-align:center; vertical-align:middle" %)Effective immediately|(% style="text-align:center; vertical-align:middle" %)129|(% style="text-align:center; vertical-align:middle" %)128 to 142|(% style="text-align:center; vertical-align:middle" %)DI/DO|(% style="text-align:center; vertical-align:middle" %)-
1260
1261 (% class="table-bordered" %)
1262 |(% rowspan="2" style="text-align:center; vertical-align:middle; width:87px" %)**P06-31**|(% style="text-align:center; vertical-align:middle; width:321px" %)**Parameter name**|(% style="text-align:center; vertical-align:middle; width:185px" %)**Setting method**|(% style="text-align:center; vertical-align:middle; width:219px" %)**Effective time**|(% style="text-align:center; vertical-align:middle; width:96px" %)**Default**|(% style="text-align:center; vertical-align:middle; width:119px" %)**Range**|(% style="text-align:center; vertical-align:middle; width:105px" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
1263 |(% style="text-align:center; vertical-align:middle; width:321px" %)DO_3 channel logic selection|(% style="text-align:center; vertical-align:middle; width:185px" %)Operation setting|(% style="text-align:center; vertical-align:middle; width:219px" %)Effective immediately|(% style="text-align:center; vertical-align:middle; width:96px" %)0|(% style="text-align:center; vertical-align:middle; width:119px" %)0 to 1|(% style="text-align:center; vertical-align:middle; width:105px" %)DI/DO|(% style="text-align:center; vertical-align:middle" %)-
1264
1265 (% class="table-bordered" %)
1266 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**P06-32**|(% style="text-align:center; vertical-align:middle" %)**Parameter name**|(% style="text-align:center; vertical-align:middle" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
1267 |(% style="text-align:center; vertical-align:middle" %)DO_4 channel function selection|(% style="text-align:center; vertical-align:middle" %)Operation setting|(% style="text-align:center; vertical-align:middle" %)Effective immediately|(% style="text-align:center; vertical-align:middle" %)134|(% style="text-align:center; vertical-align:middle" %)128 to 142|(% style="text-align:center; vertical-align:middle" %)DI/DO|(% style="text-align:center; vertical-align:middle" %)-
1268
1269 (% class="table-bordered" %)
1270 |(% rowspan="2" style="text-align:center; vertical-align:middle; width:86px" %)**P06-33**|(% style="text-align:center; vertical-align:middle; width:320px" %)**Parameter name**|(% style="text-align:center; vertical-align:middle; width:187px" %)**Setting method**|(% style="text-align:center; vertical-align:middle; width:220px" %)**Effective time**|(% style="text-align:center; vertical-align:middle; width:94px" %)**Default**|(% style="text-align:center; vertical-align:middle; width:116px" %)**Range**|(% style="text-align:center; vertical-align:middle; width:109px" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
1271 |(% style="text-align:center; vertical-align:middle; width:320px" %)DO_4 channel logic selection|(% style="text-align:center; vertical-align:middle; width:187px" %)Operation setting|(% style="text-align:center; vertical-align:middle; width:220px" %)Effective immediately|(% style="text-align:center; vertical-align:middle; width:94px" %)0|(% style="text-align:center; vertical-align:middle; width:116px" %)0 to 1|(% style="text-align:center; vertical-align:middle; width:109px" %)DI/DO|(% style="text-align:center; vertical-align:middle" %)-
1272
1273 = **Group P07 multi-segment position** =
1274
1275 (% class="table-bordered" %)
1276 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**P07-01**|(% style="text-align:center; vertical-align:middle" %)**Parameter name**|(% style="text-align:center; vertical-align:middle" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
1277 |(% style="text-align:center; vertical-align:middle" %)Multi-segment position operation mode|(% style="text-align:center; vertical-align:middle" %)Shutdown setting|(% style="text-align:center; vertical-align:middle" %)Effective immediately|(% style="text-align:center; vertical-align:middle" %)0|(% style="text-align:center; vertical-align:middle" %)0 to 2|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)-
1278 |(% colspan="8" %)(((
1279 When servo is in position mode, and P01-06 (position instruction source) =1, set the operation mode of multi-segment position
1280
1281 (% class="table-bordered" %)
1282 |(% style="text-align:center; vertical-align:middle" %)**Set value**|(% style="text-align:center; vertical-align:middle" %)**Operation mode**|(% style="text-align:center; vertical-align:middle" %)**Remarks**
1283 |(% style="text-align:center; vertical-align:middle" %)0|Single running|Stop after running one round. The segment number automatic increment switching.
1284 |(% style="text-align:center; vertical-align:middle" %)1|Cycle running|Cycle running. The segment number automatic increment switching.
1285 |(% style="text-align:center; vertical-align:middle" %)2|DI switching running|Segment number updates can continue to run. The segment numbers are determined by the DI terminal logic
1286
1287 To use multi-segment position function, a DI port channel of servo drive should configured to function 20 (ENINPOS, internal multi-segment position enable signal), and the logic of the DI terminal valid should be confirmed. Please refer to __[[Group P06 DI/DO configuration>>http://13.229.109.52:8080/wiki/servo/view/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/11%20Appendix/#HGroupP06DIDOconfiguration]]__
1288 )))
1289
1290 (% class="table-bordered" %)
1291 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**P07-02**|(% style="text-align:center; vertical-align:middle" %)**Parameter name**|(% style="text-align:center; vertical-align:middle" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
1292 |(% style="text-align:center; vertical-align:middle" %)(((
1293 Starting position number
1294 )))|(% style="text-align:center; vertical-align:middle" %)Shutdown setting|(% style="text-align:center; vertical-align:middle" %)Effective immediately|(% style="text-align:center; vertical-align:middle" %)1|(% style="text-align:center; vertical-align:middle" %)1 to 16|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)-
1295 |(% colspan="8" %)(((
1296 Set the starting segment number in single running or cycle running.
1297
1298 When P07-01≠2, the segment number automatic increment switching.
1299
1300 When P07-01=2, 4 DI ports need be set to DI function 21 (INPOS1, internal multi-segment position segment selection 1 to INPOS4, internal multi-segment position segment selection 4 ), and the segment number is switched by the servo host computer to control the DI terminal logic. Multi-segment number is 4-bit binary number. The corresponding relations between internal multi-segment position segment selection and segment number are as below.
1301
1302 If DI terminal logic is valid, the value of internal multi-segment position segment selection is 1, otherwise it is 0.
1303
1304 (% class="table-bordered" %)
1305 |(% style="text-align:center; vertical-align:middle" %)**INPOS4**|(% style="text-align:center; vertical-align:middle" %)**INPOS3**|(% style="text-align:center; vertical-align:middle" %)**INPOS2**|(% style="text-align:center; vertical-align:middle" %)**INPOS1**|(% style="text-align:center; vertical-align:middle" %)**Operation segment number**
1306 |(% style="text-align:center; vertical-align:middle" %)0|(% style="text-align:center; vertical-align:middle" %)0|(% style="text-align:center; vertical-align:middle" %)0|(% style="text-align:center; vertical-align:middle" %)0|(% style="text-align:center; vertical-align:middle" %)1
1307 |(% style="text-align:center; vertical-align:middle" %)0|(% style="text-align:center; vertical-align:middle" %)0|(% style="text-align:center; vertical-align:middle" %)0|(% style="text-align:center; vertical-align:middle" %)1|(% style="text-align:center; vertical-align:middle" %)2
1308 |(% style="text-align:center; vertical-align:middle" %)0|(% style="text-align:center; vertical-align:middle" %)0|(% style="text-align:center; vertical-align:middle" %)1|(% style="text-align:center; vertical-align:middle" %)0|(% style="text-align:center; vertical-align:middle" %)3
1309 |(% colspan="5" style="text-align:center; vertical-align:middle" %)…………
1310 |(% style="text-align:center; vertical-align:middle" %)1|(% style="text-align:center; vertical-align:middle" %)1|(% style="text-align:center; vertical-align:middle" %)1|(% style="text-align:center; vertical-align:middle" %)1|(% style="text-align:center; vertical-align:middle" %)16
1311 )))
1312
1313 (% class="table-bordered" %)
1314 |(% rowspan="2" %)**P07-03**|**Parameter name**|**Setting method**|**Effective time**|**Default**|**Range**|**Category**|**Unit**
1315 |(((
1316 End position number
1317 )))|Shutdown setting|Effective immediately|1|1 to 16|-|-
1318 |(% colspan="8" %)(((
1319 Set the end segment number in single running or cycle running.
1320
1321 When P07-01≠2, the segment number automatic increment switching. The switching sequence is: P07-02, ……, P07-03.
1322 )))
1323
1324 (% class="table-bordered" %)
1325 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**P07-04**|(% style="text-align:center; vertical-align:middle" %)**Parameter name**|(% style="text-align:center; vertical-align:middle" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
1326 |(% style="text-align:center; vertical-align:middle" %)(((
1327 Margin handling method
1328 )))|(% style="text-align:center; vertical-align:middle" %)Shutdown setting|(% style="text-align:center; vertical-align:middle" %)Effective immediately|(% style="text-align:center; vertical-align:middle" %)0|(% style="text-align:center; vertical-align:middle" %)0 to 1|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)-
1329 |(% colspan="8" %)(((
1330 The starting segment number used for the servo drive will run when it resumes after pausing in multi-segment.
1331
1332 “Pause” indicates that internal multi-segment position enable signal changes from valid to invalid.
1333
1334 (% class="table-bordered" %)
1335 |(% style="text-align:center; vertical-align:middle; width:95px" %)**Set value**|(% style="text-align:center; vertical-align:middle; width:285px" %)**Margin handling method**|(% style="text-align:center; vertical-align:middle; width:803px" %)**Remarks**
1336 |(% style="text-align:center; vertical-align:middle; width:95px" %)0|(% style="width:285px" %)Run the remaining positions|(% style="width:803px" %)If P07-03 (end segment number) =16, servo would stop running in the 2nd segment. After restoring the "Internal Multi-Segment Enable Signal", servo would run from the 3rd segment.
1337 |(% style="text-align:center; vertical-align:middle; width:95px" %)1|(% style="width:285px" %)Run again from the starting position|(% style="width:803px" %)If P07-02 (start segment number) =1, and P07-03 (end segment number) =16, servo would stop running in the 2nd segment. After restoring the "Internal Multi-Segment Enable Signal", servo would run from the set value of P07-02
1338
1339 Once paused during multi-segment position operation, the servo drive will abandon the unfinished position instructions in this segment and shutdown. Please refer to __[[Margin handling method>>url:http://docs.we-con.com.cn/wiki/servo/view/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/#F614]]__
1340 )))
1341
1342 (% class="table-bordered" %)
1343 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**P07-05**|(% style="text-align:center; vertical-align:middle" %)**Parameter name**|(% style="text-align:center; vertical-align:middle" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
1344 |(% style="text-align:center; vertical-align:middle" %)Displacement instruction type|(% style="text-align:center; vertical-align:middle" %)Shutdown setting|(% style="text-align:center; vertical-align:middle" %)Effective immediately|(% style="text-align:center; vertical-align:middle" %)0|(% style="text-align:center; vertical-align:middle" %)0 to 1|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)-
1345 |(% colspan="8" %)Set the displacement instruction type of multi-segment position function. “Displacement instruction” is the sum of the displacement instructions over a period of time.(((
1346 (% class="table-bordered" %)
1347 |(% style="text-align:center; vertical-align:middle" %)**Set value**|(% style="text-align:center; vertical-align:middle" %)**Instruction type**|(% style="text-align:center; vertical-align:middle" %)**Remarks**
1348 |(% style="text-align:center; vertical-align:middle" %)0|Relative position instruction|Relative displacement is the increment of the position of the target relative to the current position of motor.
1349 |(% style="text-align:center; vertical-align:middle" %)1|Absolute position instruction|Absolute displacement is the increment of the position of the target relative to the origin of motor
1350 )))
1351
1352 (% class="table-bordered" %)
1353 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**P07-06**|(% style="text-align:center; vertical-align:middle" %)**Parameter name**|(% style="text-align:center; vertical-align:middle" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
1354 |(% style="text-align:center; vertical-align:middle" %)(((
1355 Waiting time unit
1356 )))|(% style="text-align:center; vertical-align:middle" %)Shutdown setting|(% style="text-align:center; vertical-align:middle" %)Effective immediately|(% style="text-align:center; vertical-align:middle" %)0|(% style="text-align:center; vertical-align:middle" %)0 to 1|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)-
1357 |(% colspan="8" %)Set the waiting unit of multi-segment position function. “waiting time” is the interval between the end of this instruction and the start of the next instruction.(((
1358 (% class="table-bordered" %)
1359 |(% style="text-align:center; vertical-align:middle" %)**Set value**|(% style="text-align:center; vertical-align:middle" %)**Waiting time unit**
1360 |(% style="text-align:center; vertical-align:middle" %)0|(% style="text-align:center; vertical-align:middle" %)ms
1361 |(% style="text-align:center; vertical-align:middle" %)1|(% style="text-align:center; vertical-align:middle" %)s
1362 )))
1363
1364 (% class="table-bordered" %)
1365 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**P07-09**|(% style="text-align:center; vertical-align:middle" %)**Parameter name**|(% style="text-align:center; vertical-align:middle" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
1366 |(% style="text-align:center; vertical-align:middle" %)The 1st segment displacement|(% style="text-align:center; vertical-align:middle" %)Operation setting|(% style="text-align:center; vertical-align:middle" %)Effective immediately|(% style="text-align:center; vertical-align:middle" %)10000|(% style="text-align:center; vertical-align:middle" %)-2147483647 to 2147483646|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)-
1367 |(% colspan="8" %)Set the 1st segment position displacement
1368
1369 (% class="table-bordered" %)
1370 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**P07-10**|(% style="text-align:center; vertical-align:middle; width:358px" %)**Parameter name**|(% style="text-align:center; vertical-align:middle; width:209px" %)**Setting method**|(% style="text-align:center; vertical-align:middle; width:218px" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
1371 |(% style="text-align:center; vertical-align:middle; width:358px" %)Maximum speed of the 1st segment displacement|(% style="text-align:center; vertical-align:middle; width:209px" %)Operation setting|(% style="text-align:center; vertical-align:middle; width:218px" %)Effective immediately|(% style="text-align:center; vertical-align:middle" %)100|(% style="text-align:center; vertical-align:middle" %)1 to 5000|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)rpm
1372 |(% colspan="8" %)Set the maximum speed of the 1st position displacement. Maximum running speed refers to the speed the motor that is not in the process of acceleration and deceleration. If P07-09 (1st position displacement) is set too small, the actual speed of motor would be less than P07-10.
1373
1374 (% class="table-bordered" %)
1375 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**P07-11**|(% style="text-align:center; vertical-align:middle" %)**Parameter name**|(% style="text-align:center; vertical-align:middle" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
1376 |(% style="text-align:center; vertical-align:middle" %)Acceleration and deceleration time of the 1st segment displacement|(% style="text-align:center; vertical-align:middle" %)Operation setting|(% style="text-align:center; vertical-align:middle" %)Effective immediately|(% style="text-align:center; vertical-align:middle" %)100|(% style="text-align:center; vertical-align:middle" %)1 to 65535|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)ms
1377 |(% colspan="8" %)Used to set the time when the motor in the multi-segment position is uniformly accelerated from 0rpm to the P07-10 (maximum speed of the 1st segment displacement) in the multi-segment position.
1378
1379 (% class="table-bordered" %)
1380 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**P07-12**|(% style="text-align:center; vertical-align:middle" %)**Parameter name**|(% style="text-align:center; vertical-align:middle" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
1381 |(% style="text-align:center; vertical-align:middle" %)Waiting time after completion of the 1st segment displacement|(% style="text-align:center; vertical-align:middle" %)Operation setting|(% style="text-align:center; vertical-align:middle" %)Effective immediately|(% style="text-align:center; vertical-align:middle" %)100|(% style="text-align:center; vertical-align:middle" %)1 to 65535|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)Set by P07-06
1382 |(% colspan="8" %)Used to set the waiting time before running the next segment displacement after the multi-segment position of the 1st displacement is completed
1383
1384 (% class="table-bordered" %)
1385 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**P07-13**|(% style="text-align:center; vertical-align:middle" %)**Parameter name**|(% style="text-align:center; vertical-align:middle" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
1386 |(% style="text-align:center; vertical-align:middle" %)(((
1387 The 2nd segment displacement
1388 )))|(% style="text-align:center; vertical-align:middle" %)Operation setting|(% style="text-align:center; vertical-align:middle" %)Effective immediately|(% style="text-align:center; vertical-align:middle" %)10000|(% style="text-align:center; vertical-align:middle" %)-2147483647 to 2147483646|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)-
1389
1390 (% class="table-bordered" %)
1391 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**P07-14**|(% style="text-align:center; vertical-align:middle" %)**Parameter name**|(% style="text-align:center; vertical-align:middle" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
1392 |(% style="text-align:center; vertical-align:middle" %)Maximum speed of the 2nd segment displacement|(% style="text-align:center; vertical-align:middle" %)Operation setting|(% style="text-align:center; vertical-align:middle" %)Effective immediately|(% style="text-align:center; vertical-align:middle" %)100|(% style="text-align:center; vertical-align:middle" %)1 to 5000|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)rpm
1393
1394 (% class="table-bordered" %)
1395 |(% rowspan="2" style="text-align:center; vertical-align:middle; width:80px" %)**P07-15**|(% style="text-align:center; vertical-align:middle; width:501px" %)**Parameter name**|(% style="text-align:center; vertical-align:middle" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
1396 |(% style="text-align:center; vertical-align:middle; width:501px" %)Acceleration and deceleration time of the 2nd segment displacement|(% style="text-align:center; vertical-align:middle" %)Operation setting|(% style="text-align:center; vertical-align:middle" %)Effective immediately|(% style="text-align:center; vertical-align:middle" %)100|(% style="text-align:center; vertical-align:middle" %)1 to 65535|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)ms
1397
1398 (% class="table-bordered" %)
1399 |(% rowspan="2" style="text-align:center; vertical-align:middle; width:76px" %)**P07-16**|(% style="text-align:center; vertical-align:middle; width:455px" %)**Parameter name**|(% style="text-align:center; vertical-align:middle" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
1400 |(% style="text-align:center; vertical-align:middle; width:455px" %)Waiting time after completion of the 2nd segment displacement|(% style="text-align:center; vertical-align:middle" %)Operation setting|(% style="text-align:center; vertical-align:middle" %)Effective immediately|(% style="text-align:center; vertical-align:middle" %)100|(% style="text-align:center; vertical-align:middle" %)1 to 65535|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)Set by P07-06
1401
1402 (% class="table-bordered" %)
1403 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**P07-17**|(% style="text-align:center; vertical-align:middle" %)**Parameter name**|(% style="text-align:center; vertical-align:middle" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
1404 |(% style="text-align:center; vertical-align:middle" %)(((
1405 The 3rd segment displacement
1406 )))|(% style="text-align:center; vertical-align:middle" %)Operation setting|(% style="text-align:center; vertical-align:middle" %)Effective immediately|(% style="text-align:center; vertical-align:middle" %)10000|(% style="text-align:center; vertical-align:middle" %)-2147483647 to 2147483646|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)-
1407
1408 (% class="table-bordered" %)
1409 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**P07-18**|(% style="text-align:center; vertical-align:middle" %)**Parameter name**|(% style="text-align:center; vertical-align:middle" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
1410 |(% style="text-align:center; vertical-align:middle" %)Maximum speed of the 3rd segment displacement|(% style="text-align:center; vertical-align:middle" %)Operation setting|(% style="text-align:center; vertical-align:middle" %)Effective immediately|(% style="text-align:center; vertical-align:middle" %)100|(% style="text-align:center; vertical-align:middle" %)1 to 5000|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)rpm
1411
1412 (% class="table-bordered" %)
1413 |(% rowspan="2" style="text-align:center; vertical-align:middle; width:79px" %)**P07-19**|(% style="text-align:center; vertical-align:middle; width:500px" %)**Parameter name**|(% style="text-align:center; vertical-align:middle" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
1414 |(% style="text-align:center; vertical-align:middle; width:500px" %)Acceleration and deceleration time of the 3rd segment displacement|(% style="text-align:center; vertical-align:middle" %)Operation setting|(% style="text-align:center; vertical-align:middle" %)Effective immediately|(% style="text-align:center; vertical-align:middle" %)100|(% style="text-align:center; vertical-align:middle" %)1 to 65535|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)ms
1415
1416 (% class="table-bordered" %)
1417 |(% rowspan="2" style="text-align:center; vertical-align:middle; width:80px" %)**P07-20**|(% style="text-align:center; vertical-align:middle; width:449px" %)**Parameter name**|(% style="text-align:center; vertical-align:middle" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
1418 |(% style="text-align:center; vertical-align:middle; width:449px" %)Waiting time after completion of the 3rd segment displacement|(% style="text-align:center; vertical-align:middle" %)Operation setting|(% style="text-align:center; vertical-align:middle" %)Effective immediately|(% style="text-align:center; vertical-align:middle" %)100|(% style="text-align:center; vertical-align:middle" %)1 to 65535|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)Set by P07-06
1419
1420 (% class="table-bordered" %)
1421 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**P07-21**|(% style="text-align:center; vertical-align:middle" %)**Parameter name**|(% style="text-align:center; vertical-align:middle" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
1422 |(% style="text-align:center; vertical-align:middle" %)(((
1423 The 4th segment displacement
1424 )))|(% style="text-align:center; vertical-align:middle" %)Operation setting|(% style="text-align:center; vertical-align:middle" %)Effective immediately|(% style="text-align:center; vertical-align:middle" %)10000|(% style="text-align:center; vertical-align:middle" %)-2147483647 to 2147483646|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)-
1425
1426 (% class="table-bordered" %)
1427 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**P07-22**|(% style="text-align:center; vertical-align:middle" %)**Parameter name**|(% style="text-align:center; vertical-align:middle" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
1428 |(% style="text-align:center; vertical-align:middle" %)Maximum speed of the 4th segment displacement|(% style="text-align:center; vertical-align:middle" %)Operation setting|(% style="text-align:center; vertical-align:middle" %)Effective immediately|(% style="text-align:center; vertical-align:middle" %)100|(% style="text-align:center; vertical-align:middle" %)1 to 5000|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)rpm
1429
1430 (% class="table-bordered" %)
1431 |(% rowspan="2" style="text-align:center; vertical-align:middle; width:79px" %)**P07-23**|(% style="text-align:center; vertical-align:middle; width:499px" %)**Parameter name**|(% style="text-align:center; vertical-align:middle" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
1432 |(% style="text-align:center; vertical-align:middle; width:499px" %)Acceleration and deceleration time of the 4th segment displacement|(% style="text-align:center; vertical-align:middle" %)Operation setting|(% style="text-align:center; vertical-align:middle" %)Effective immediately|(% style="text-align:center; vertical-align:middle" %)100|(% style="text-align:center; vertical-align:middle" %)1 to 65535|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)ms
1433
1434 (% class="table-bordered" %)
1435 |(% rowspan="2" style="text-align:center; vertical-align:middle; width:80px" %)**P07-24**|(% style="text-align:center; vertical-align:middle; width:449px" %)**Parameter name**|(% style="text-align:center; vertical-align:middle" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
1436 |(% style="text-align:center; vertical-align:middle; width:449px" %)Waiting time after completion of the 4th segment displacement|(% style="text-align:center; vertical-align:middle" %)Operation setting|(% style="text-align:center; vertical-align:middle" %)Effective immediately|(% style="text-align:center; vertical-align:middle" %)100|(% style="text-align:center; vertical-align:middle" %)1 to 65535|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)Set by P07-06
1437
1438 (% class="table-bordered" %)
1439 |(% rowspan="2" style="text-align:center; vertical-align:middle; width:78px" %)**P07-25**|(% style="text-align:center; vertical-align:middle; width:229px" %)**Parameter name**|(% style="text-align:center; vertical-align:middle; width:139px" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
1440 |(% style="text-align:center; vertical-align:middle; width:229px" %)(((
1441 The 5th segment displacement
1442 )))|(% style="text-align:center; vertical-align:middle; width:139px" %)Operation setting|(% style="text-align:center; vertical-align:middle" %)Effective immediately|(% style="text-align:center; vertical-align:middle" %)10000|(% style="text-align:center; vertical-align:middle" %)-2147483647 to 2147483646|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)-
1443
1444 (% class="table-bordered" %)
1445 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**P07-26**|(% style="text-align:center; vertical-align:middle" %)**Parameter name**|(% style="text-align:center; vertical-align:middle" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
1446 |(% style="text-align:center; vertical-align:middle" %)Maximum speed of the 5th segment displacement|(% style="text-align:center; vertical-align:middle" %)Operation setting|(% style="text-align:center; vertical-align:middle" %)Effective immediately|(% style="text-align:center; vertical-align:middle" %)100|(% style="text-align:center; vertical-align:middle" %)1 to 5000|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)rpm
1447
1448 (% class="table-bordered" %)
1449 |(% rowspan="2" style="text-align:center; vertical-align:middle; width:81px" %)**P07-27**|(% style="text-align:center; vertical-align:middle; width:497px" %)**Parameter name**|(% style="text-align:center; vertical-align:middle" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
1450 |(% style="text-align:center; vertical-align:middle; width:497px" %)Acceleration and deceleration time of the 5th segment displacement|(% style="text-align:center; vertical-align:middle" %)Operation setting|(% style="text-align:center; vertical-align:middle" %)Effective immediately|(% style="text-align:center; vertical-align:middle" %)100|(% style="text-align:center; vertical-align:middle" %)1 to 65535|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)ms
1451
1452 (% class="table-bordered" %)
1453 |(% rowspan="2" style="text-align:center; vertical-align:middle; width:79px" %)**P07-28**|(% style="text-align:center; vertical-align:middle; width:450px" %)**Parameter name**|(% style="text-align:center; vertical-align:middle" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
1454 |(% style="text-align:center; vertical-align:middle; width:450px" %)Waiting time after completion of the 5th segment displacement|(% style="text-align:center; vertical-align:middle" %)Operation setting|(% style="text-align:center; vertical-align:middle" %)Effective immediately|(% style="text-align:center; vertical-align:middle" %)100|(% style="text-align:center; vertical-align:middle" %)1 to 65535|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)Set by P07-06
1455
1456 (% class="table-bordered" %)
1457 |(% rowspan="2" style="text-align:center; vertical-align:middle; width:80px" %)**P07-29**|(% style="text-align:center; vertical-align:middle; width:241px" %)**Parameter name **|(% style="text-align:center; vertical-align:middle; width:181px" %)**Setting method**|(% style="text-align:center; vertical-align:middle; width:174px" %)**Effective time**|(% style="text-align:center; vertical-align:middle; width:92px" %)**Default**|(% style="text-align:center; vertical-align:middle; width:253px" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
1458 |(% style="text-align:center; vertical-align:middle; width:241px" %)(((
1459 The 6th segment displacement
1460 )))|(% style="text-align:center; vertical-align:middle; width:181px" %)Operation setting|(% style="text-align:center; vertical-align:middle; width:174px" %)Effective immediately|(% style="text-align:center; vertical-align:middle; width:92px" %)10000|(% style="text-align:center; vertical-align:middle; width:253px" %)-2147483647 to 2147483646|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)-
1461
1462 (% class="table-bordered" %)
1463 |(% rowspan="2" style="text-align:center; vertical-align:middle; width:81px" %)**P07-30**|(% style="text-align:center; vertical-align:middle; width:421px" %)**Parameter name**|(% style="text-align:center; vertical-align:middle" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
1464 |(% style="text-align:center; vertical-align:middle; width:421px" %)Maximum speed of the 6th segment displacement|(% style="text-align:center; vertical-align:middle" %)Operation setting|(% style="text-align:center; vertical-align:middle" %)Effective immediately|(% style="text-align:center; vertical-align:middle" %)100|(% style="text-align:center; vertical-align:middle" %)1 to 5000|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)rpm
1465
1466 (% class="table-bordered" %)
1467 |(% rowspan="2" style="text-align:center; vertical-align:middle; width:82px" %)**P07-31**|(% style="text-align:center; vertical-align:middle; width:491px" %)**Parameter name**|(% style="text-align:center; vertical-align:middle" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
1468 |(% style="text-align:center; vertical-align:middle; width:491px" %)Acceleration and deceleration time of the 6th segment displacement|(% style="text-align:center; vertical-align:middle" %)Operation setting|(% style="text-align:center; vertical-align:middle" %)Effective immediately|(% style="text-align:center; vertical-align:middle" %)100|(% style="text-align:center; vertical-align:middle" %)1 to 65535|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)ms
1469
1470 (% class="table-bordered" %)
1471 |(% rowspan="2" style="text-align:center; vertical-align:middle; width:85px" %)**P07-32**|(% style="text-align:center; vertical-align:middle; width:439px" %)**Parameter name**|(% style="text-align:center; vertical-align:middle" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
1472 |(% style="text-align:center; vertical-align:middle; width:439px" %)Waiting time after completion of the 6th segment displacement|(% style="text-align:center; vertical-align:middle" %)Operation setting|(% style="text-align:center; vertical-align:middle" %)Effective immediately|(% style="text-align:center; vertical-align:middle" %)100|(% style="text-align:center; vertical-align:middle" %)1 to 65535|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)Set by P07-06
1473
1474 (% class="table-bordered" %)
1475 |(% rowspan="2" style="text-align:center; vertical-align:middle; width:85px" %)**P07-33**|(% style="text-align:center; vertical-align:middle; width:222px" %)**Parameter name**|(% style="text-align:center; vertical-align:middle; width:142px" %)**Setting method**|(% style="text-align:center; vertical-align:middle; width:206px" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
1476 |(% style="text-align:center; vertical-align:middle; width:222px" %)(((
1477 The 7th segment displacement
1478 )))|(% style="text-align:center; vertical-align:middle; width:142px" %)Operation setting|(% style="text-align:center; vertical-align:middle; width:206px" %)Effective immediately|(% style="text-align:center; vertical-align:middle" %)10000|(% style="text-align:center; vertical-align:middle" %)-2147483647 to 2147483646|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)-
1479
1480 (% class="table-bordered" %)
1481 |(% rowspan="2" style="text-align:center; vertical-align:middle; width:88px" %)**P07-34**|(% style="text-align:center; vertical-align:middle; width:414px" %)**Parameter name**|(% style="text-align:center; vertical-align:middle" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
1482 |(% style="text-align:center; vertical-align:middle; width:414px" %)Maximum speed of the 7th segment displacement|(% style="text-align:center; vertical-align:middle" %)Operation setting|(% style="text-align:center; vertical-align:middle" %)Effective immediately|(% style="text-align:center; vertical-align:middle" %)100|(% style="text-align:center; vertical-align:middle" %)1 to 5000|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)rpm
1483
1484 (% class="table-bordered" %)
1485 |(% rowspan="2" style="text-align:center; vertical-align:middle; width:87px" %)**P07-35**|(% style="text-align:center; vertical-align:middle; width:486px" %)**Parameter name**|(% style="text-align:center; vertical-align:middle" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
1486 |(% style="text-align:center; vertical-align:middle; width:486px" %)Acceleration and deceleration time of the 7th segment displacement|(% style="text-align:center; vertical-align:middle" %)Operation setting|(% style="text-align:center; vertical-align:middle" %)Effective immediately|(% style="text-align:center; vertical-align:middle" %)100|(% style="text-align:center; vertical-align:middle" %)1 to 65535|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)ms
1487
1488 (% class="table-bordered" %)
1489 |(% rowspan="2" style="text-align:center; vertical-align:middle; width:86px" %)**P07-36**|(% style="text-align:center; vertical-align:middle; width:438px" %)**Parameter name**|(% style="text-align:center; vertical-align:middle" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
1490 |(% style="text-align:center; vertical-align:middle; width:438px" %)Waiting time after completion of the 7th segment displacement|(% style="text-align:center; vertical-align:middle" %)Operation setting|(% style="text-align:center; vertical-align:middle" %)Effective immediately|(% style="text-align:center; vertical-align:middle" %)100|(% style="text-align:center; vertical-align:middle" %)1 to 65535|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)Set by P07-06
1491
1492 (% class="table-bordered" %)
1493 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**P07-37**|(% style="text-align:center; vertical-align:middle; width:218px" %)**Parameter name**|(% style="text-align:center; vertical-align:middle; width:138px" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
1494 |(% style="text-align:center; vertical-align:middle; width:218px" %)(((
1495 The 8th segment displacement
1496 )))|(% style="text-align:center; vertical-align:middle; width:138px" %)Operation setting|(% style="text-align:center; vertical-align:middle" %)Effective immediately|(% style="text-align:center; vertical-align:middle" %)10000|(% style="text-align:center; vertical-align:middle" %)-2147483647 to 2147483646|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)-
1497
1498 (% class="table-bordered" %)
1499 |(% rowspan="2" style="text-align:center; vertical-align:middle; width:87px" %)**P07-38**|(% style="text-align:center; vertical-align:middle; width:415px" %)**Parameter name**|(% style="text-align:center; vertical-align:middle" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
1500 |(% style="text-align:center; vertical-align:middle; width:415px" %)Maximum speed of the 8th segment displacement|(% style="text-align:center; vertical-align:middle" %)Operation setting|(% style="text-align:center; vertical-align:middle" %)Effective immediately|(% style="text-align:center; vertical-align:middle" %)100|(% style="text-align:center; vertical-align:middle" %)1 to 5000|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)rpm
1501
1502 (% class="table-bordered" %)
1503 |(% rowspan="2" style="text-align:center; vertical-align:middle; width:86px" %)**P07-39**|(% style="text-align:center; vertical-align:middle; width:487px" %)**Parameter name**|(% style="text-align:center; vertical-align:middle" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
1504 |(% style="text-align:center; vertical-align:middle; width:487px" %)Acceleration and deceleration time of the 8th segment displacement|(% style="text-align:center; vertical-align:middle" %)Operation setting|(% style="text-align:center; vertical-align:middle" %)Effective immediately|(% style="text-align:center; vertical-align:middle" %)100|(% style="text-align:center; vertical-align:middle" %)1 to 65535|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)ms
1505
1506 (% class="table-bordered" %)
1507 |(% rowspan="2" style="text-align:center; vertical-align:middle; width:88px" %)**P07-40**|(% style="text-align:center; vertical-align:middle; width:436px" %)**Parameter name**|(% style="text-align:center; vertical-align:middle" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
1508 |(% style="text-align:center; vertical-align:middle; width:436px" %)Waiting time after completion of the 8th segment displacement|(% style="text-align:center; vertical-align:middle" %)Operation setting|(% style="text-align:center; vertical-align:middle" %)Effective immediately|(% style="text-align:center; vertical-align:middle" %)100|(% style="text-align:center; vertical-align:middle" %)1 to 65535|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)Set by P07-06
1509
1510 (% class="table-bordered" %)
1511 |(% rowspan="2" style="text-align:center; vertical-align:middle; width:88px" %)**P07-41**|(% style="text-align:center; vertical-align:middle; width:259px" %)**Parameter name**|(% style="text-align:center; vertical-align:middle" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
1512 |(% style="text-align:center; vertical-align:middle; width:259px" %)(((
1513 The 9th segment displacement
1514 )))|(% style="text-align:center; vertical-align:middle" %)Operation setting|(% style="text-align:center; vertical-align:middle" %)Effective immediately|(% style="text-align:center; vertical-align:middle" %)10000|(% style="text-align:center; vertical-align:middle" %)-2147483647 to 2147483646|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)-
1515
1516 (% class="table-bordered" %)
1517 |(% rowspan="2" style="text-align:center; vertical-align:middle; width:85px" %)**P07-42**|(% style="text-align:center; vertical-align:middle; width:417px" %)**Parameter name**|(% style="text-align:center; vertical-align:middle" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
1518 |(% style="text-align:center; vertical-align:middle; width:417px" %)Maximum speed of the 9th segment displacement|(% style="text-align:center; vertical-align:middle" %)Operation setting|(% style="text-align:center; vertical-align:middle" %)Effective immediately|(% style="text-align:center; vertical-align:middle" %)100|(% style="text-align:center; vertical-align:middle" %)1 to 5000|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)rpm
1519
1520 (% class="table-bordered" %)
1521 |(% rowspan="2" style="text-align:center; vertical-align:middle; width:86px" %)**P07-43**|(% style="text-align:center; vertical-align:middle; width:487px" %)**Parameter name**|(% style="text-align:center; vertical-align:middle" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
1522 |(% style="text-align:center; vertical-align:middle; width:487px" %)Acceleration and deceleration time of the 9th segment displacement|(% style="text-align:center; vertical-align:middle" %)Operation setting|(% style="text-align:center; vertical-align:middle" %)Effective immediately|(% style="text-align:center; vertical-align:middle" %)100|(% style="text-align:center; vertical-align:middle" %)1 to 65535|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)ms
1523
1524 (% class="table-bordered" %)
1525 |(% rowspan="2" style="text-align:center; vertical-align:middle; width:86px" %)**P07-44**|(% style="text-align:center; vertical-align:middle; width:438px" %)**Parameter name**|(% style="text-align:center; vertical-align:middle" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
1526 |(% style="text-align:center; vertical-align:middle; width:438px" %)Waiting time after completion of the 9th segment displacement|(% style="text-align:center; vertical-align:middle" %)Operation setting|(% style="text-align:center; vertical-align:middle" %)Effective immediately|(% style="text-align:center; vertical-align:middle" %)100|(% style="text-align:center; vertical-align:middle" %)1 to 65535|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)Set by P07-06
1527
1528 (% class="table-bordered" %)
1529 |(% rowspan="2" style="text-align:center; vertical-align:middle; width:85px" %)**P07-45**|(% style="text-align:center; vertical-align:middle; width:265px" %)**Parameter name**|(% style="text-align:center; vertical-align:middle" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
1530 |(% style="text-align:center; vertical-align:middle; width:265px" %)(((
1531 The 10th segment displacement
1532 )))|(% style="text-align:center; vertical-align:middle" %)Operation setting|(% style="text-align:center; vertical-align:middle" %)Effective immediately|(% style="text-align:center; vertical-align:middle" %)10000|(% style="text-align:center; vertical-align:middle" %)-2147483647 to 2147483646|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)-
1533
1534 (% class="table-bordered" %)
1535 |(% rowspan="2" style="text-align:center; vertical-align:middle; width:84px" %)**P07-46**|(% style="text-align:center; vertical-align:middle; width:419px" %)**Parameter name**|(% style="text-align:center; vertical-align:middle" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
1536 |(% style="text-align:center; vertical-align:middle; width:419px" %)Maximum speed of the 10th segment displacement|(% style="text-align:center; vertical-align:middle" %)Operation setting|(% style="text-align:center; vertical-align:middle" %)Effective immediately|(% style="text-align:center; vertical-align:middle" %)100|(% style="text-align:center; vertical-align:middle" %)1 to 5000|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)rpm
1537
1538 (% class="table-bordered" %)
1539 |(% rowspan="2" style="text-align:center; vertical-align:middle; width:83px" %)**P07-47**|(% style="text-align:center; vertical-align:middle; width:489px" %)**Parameter name**|(% style="text-align:center; vertical-align:middle" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
1540 |(% style="text-align:center; vertical-align:middle; width:489px" %)Acceleration and deceleration time of the 10th segment displacement|(% style="text-align:center; vertical-align:middle" %)Operation setting|(% style="text-align:center; vertical-align:middle" %)Effective immediately|(% style="text-align:center; vertical-align:middle" %)100|(% style="text-align:center; vertical-align:middle" %)1 to 65535|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)ms
1541
1542 (% class="table-bordered" %)
1543 |(% rowspan="2" style="text-align:center; vertical-align:middle; width:83px" %)**P07-48**|(% style="text-align:center; vertical-align:middle; width:440px" %)**Parameter name**|(% style="text-align:center; vertical-align:middle" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
1544 |(% style="text-align:center; vertical-align:middle; width:440px" %)Waiting time after completion of the 10th segment displacement|(% style="text-align:center; vertical-align:middle" %)Operation setting|(% style="text-align:center; vertical-align:middle" %)Effective immediately|(% style="text-align:center; vertical-align:middle" %)100|(% style="text-align:center; vertical-align:middle" %)1 to 65535|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)Set by P07-06
1545
1546 (% class="table-bordered" %)
1547 |(% rowspan="2" style="text-align:center; vertical-align:middle; width:82px" %)**P07-49**|(% style="text-align:center; vertical-align:middle; width:233px" %)**Parameter name**|(% style="text-align:center; vertical-align:middle; width:163px" %)**Setting method**|(% style="text-align:center; vertical-align:middle; width:172px" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
1548 |(% style="text-align:center; vertical-align:middle; width:233px" %)(((
1549 The 11th segment displacement
1550 )))|(% style="text-align:center; vertical-align:middle; width:163px" %)Operation setting|(% style="text-align:center; vertical-align:middle; width:172px" %)Effective immediately|(% style="text-align:center; vertical-align:middle" %)10000|(% style="text-align:center; vertical-align:middle" %)-2147483647 to 2147483646|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)-
1551
1552 (% class="table-bordered" %)
1553 |(% rowspan="2" style="text-align:center; vertical-align:middle; width:82px" %)**P07-50**|(% style="text-align:center; vertical-align:middle; width:396px" %)**Parameter name**|(% style="text-align:center; vertical-align:middle; width:184px" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
1554 |(% style="text-align:center; vertical-align:middle; width:396px" %)Maximum speed of the 11th segment displacement|(% style="text-align:center; vertical-align:middle; width:184px" %)Operation setting|(% style="text-align:center; vertical-align:middle" %)Effective immediately|(% style="text-align:center; vertical-align:middle" %)100|(% style="text-align:center; vertical-align:middle" %)1 to 5000|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)rpm
1555
1556 (% class="table-bordered" %)
1557 |(% rowspan="2" style="text-align:center; vertical-align:middle; width:80px" %)**P07-51**|(% style="text-align:center; vertical-align:middle; width:492px" %)**Parameter name**|(% style="text-align:center; vertical-align:middle" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
1558 |(% style="text-align:center; vertical-align:middle; width:492px" %)Acceleration and deceleration time of the 11th segment displacement|(% style="text-align:center; vertical-align:middle" %)Operation setting|(% style="text-align:center; vertical-align:middle" %)Effective immediately|(% style="text-align:center; vertical-align:middle" %)100|(% style="text-align:center; vertical-align:middle" %)1 to 65535|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)ms
1559
1560 (% class="table-bordered" %)
1561 |(% rowspan="2" style="text-align:center; vertical-align:middle; width:80px" %)**P07-52**|(% style="text-align:center; vertical-align:middle; width:443px" %)**Parameter name**|(% style="text-align:center; vertical-align:middle" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
1562 |(% style="text-align:center; vertical-align:middle; width:443px" %)Waiting time after completion of the 11th segment displacement|(% style="text-align:center; vertical-align:middle" %)Operation setting|(% style="text-align:center; vertical-align:middle" %)Effective immediately|(% style="text-align:center; vertical-align:middle" %)100|(% style="text-align:center; vertical-align:middle" %)1 to 65535|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)Set by P07-06
1563
1564 (% class="table-bordered" %)
1565 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**P07-53**|(% style="text-align:center; vertical-align:middle" %)**Parameter name**|(% style="text-align:center; vertical-align:middle" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
1566 |(% style="text-align:center; vertical-align:middle" %)(((
1567 The 12th segment displacement
1568 )))|(% style="text-align:center; vertical-align:middle" %)Operation setting|(% style="text-align:center; vertical-align:middle" %)Effective immediately|(% style="text-align:center; vertical-align:middle" %)10000|(% style="text-align:center; vertical-align:middle" %)-2147483647 to 2147483646|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)-
1569
1570 (% class="table-bordered" %)
1571 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**P07-54**|(% style="text-align:center; vertical-align:middle" %)**Parameter name**|(% style="text-align:center; vertical-align:middle" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
1572 |(% style="text-align:center; vertical-align:middle" %)Maximum speed of the 12th segment displacement|(% style="text-align:center; vertical-align:middle" %)Operation setting|(% style="text-align:center; vertical-align:middle" %)Effective immediately|(% style="text-align:center; vertical-align:middle" %)100|(% style="text-align:center; vertical-align:middle" %)1 to 5000|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)rpm
1573
1574 (% class="table-bordered" %)
1575 |(% rowspan="2" style="text-align:center; vertical-align:middle; width:75px" %)**P07-55**|(% style="text-align:center; vertical-align:middle; width:497px" %)**Parameter name**|(% style="text-align:center; vertical-align:middle" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
1576 |(% style="text-align:center; vertical-align:middle; width:497px" %)Acceleration and deceleration time of the 12th segment displacement|(% style="text-align:center; vertical-align:middle" %)Operation setting|(% style="text-align:center; vertical-align:middle" %)Effective immediately|(% style="text-align:center; vertical-align:middle" %)100|(% style="text-align:center; vertical-align:middle" %)1 to 65535|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)ms
1577
1578 (% class="table-bordered" %)
1579 |(% rowspan="2" style="text-align:center; vertical-align:middle; width:77px" %)**P07-56**|(% style="text-align:center; vertical-align:middle; width:446px" %)**Parameter name**|(% style="text-align:center; vertical-align:middle" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
1580 |(% style="text-align:center; vertical-align:middle; width:446px" %)Waiting time after completion of the 12th segment displacement|(% style="text-align:center; vertical-align:middle" %)Operation setting|(% style="text-align:center; vertical-align:middle" %)Effective immediately|(% style="text-align:center; vertical-align:middle" %)100|(% style="text-align:center; vertical-align:middle" %)1 to 65535|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)Set by P07-06
1581
1582 (% class="table-bordered" %)
1583 |(% rowspan="2" style="text-align:center; vertical-align:middle; width:77px" %)**P07-57**|(% style="text-align:center; vertical-align:middle; width:252px" %)**Parameter name**|(% style="text-align:center; vertical-align:middle; width:159px" %)**Setting method**|(% style="text-align:center; vertical-align:middle; width:162px" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
1584 |(% style="text-align:center; vertical-align:middle; width:252px" %)(((
1585 The 13th segment displacement
1586 )))|(% style="text-align:center; vertical-align:middle; width:159px" %)Operation setting|(% style="text-align:center; vertical-align:middle; width:162px" %)Effective immediately|(% style="text-align:center; vertical-align:middle" %)10000|(% style="text-align:center; vertical-align:middle" %)-2147483647 to 2147483646|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)-
1587
1588 (% class="table-bordered" %)
1589 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**P07-58**|(% style="text-align:center; vertical-align:middle" %)**Parameter name**|(% style="text-align:center; vertical-align:middle" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
1590 |(% style="text-align:center; vertical-align:middle" %)Maximum speed of the 13th segment displacement|(% style="text-align:center; vertical-align:middle" %)Operation setting|(% style="text-align:center; vertical-align:middle" %)Effective immediately|(% style="text-align:center; vertical-align:middle" %)100|(% style="text-align:center; vertical-align:middle" %)1 to 5000|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)rpm
1591
1592 (% class="table-bordered" %)
1593 |(% rowspan="2" style="text-align:center; vertical-align:middle; width:78px" %)**P07-59**|(% style="text-align:center; vertical-align:middle; width:494px" %)**Parameter name**|(% style="text-align:center; vertical-align:middle" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
1594 |(% style="text-align:center; vertical-align:middle; width:494px" %)Acceleration and deceleration time of the 13th segment displacement|(% style="text-align:center; vertical-align:middle" %)Operation setting|(% style="text-align:center; vertical-align:middle" %)Effective immediately|(% style="text-align:center; vertical-align:middle" %)100|(% style="text-align:center; vertical-align:middle" %)1 to 65535|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)ms
1595
1596 (% class="table-bordered" %)
1597 |(% rowspan="2" style="text-align:center; vertical-align:middle; width:79px" %)**P07-60**|(% style="text-align:center; vertical-align:middle; width:444px" %)**Parameter name**|(% style="text-align:center; vertical-align:middle" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
1598 |(% style="text-align:center; vertical-align:middle; width:444px" %)Waiting time after completion of the 13th segment displacement|(% style="text-align:center; vertical-align:middle" %)Operation setting|(% style="text-align:center; vertical-align:middle" %)Effective immediately|(% style="text-align:center; vertical-align:middle" %)100|(% style="text-align:center; vertical-align:middle" %)1 to 65535|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)Set by P07-06
1599
1600 (% class="table-bordered" %)
1601 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**P07-61**|(% style="text-align:center; vertical-align:middle" %)**Parameter name**|(% style="text-align:center; vertical-align:middle" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
1602 |(% style="text-align:center; vertical-align:middle" %)(((
1603 The 14th segment displacement
1604 )))|(% style="text-align:center; vertical-align:middle" %)Operation setting|(% style="text-align:center; vertical-align:middle" %)Effective immediately|(% style="text-align:center; vertical-align:middle" %)10000|(% style="text-align:center; vertical-align:middle" %)-2147483647 to 2147483646|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)-
1605
1606 (% class="table-bordered" %)
1607 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**P07-62**|(% style="text-align:center; vertical-align:middle" %)**Parameter name**|(% style="text-align:center; vertical-align:middle" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
1608 |(% style="text-align:center; vertical-align:middle" %)Maximum speed of the 14th segment displacement|(% style="text-align:center; vertical-align:middle" %)Operation setting|(% style="text-align:center; vertical-align:middle" %)Effective immediately|(% style="text-align:center; vertical-align:middle" %)100|(% style="text-align:center; vertical-align:middle" %)1 to 5000|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)rpm
1609
1610 (% class="table-bordered" %)
1611 |(% rowspan="2" style="text-align:center; vertical-align:middle; width:77px" %)**P07-63**|(% style="text-align:center; vertical-align:middle; width:495px" %)**Parameter name**|(% style="text-align:center; vertical-align:middle" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
1612 |(% style="text-align:center; vertical-align:middle; width:495px" %)Acceleration and deceleration time of the 14th segment displacement|(% style="text-align:center; vertical-align:middle" %)Operation setting|(% style="text-align:center; vertical-align:middle" %)Effective immediately|(% style="text-align:center; vertical-align:middle" %)100|(% style="text-align:center; vertical-align:middle" %)1 to 65535|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)ms
1613
1614 (% class="table-bordered" %)
1615 |(% rowspan="2" style="text-align:center; vertical-align:middle; width:78px" %)**P07-64**|(% style="text-align:center; vertical-align:middle; width:445px" %)**Parameter name**|(% style="text-align:center; vertical-align:middle" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
1616 |(% style="text-align:center; vertical-align:middle; width:445px" %)Waiting time after completion of the 14th segment displacement|(% style="text-align:center; vertical-align:middle" %)Operation setting|(% style="text-align:center; vertical-align:middle" %)Effective immediately|(% style="text-align:center; vertical-align:middle" %)100|(% style="text-align:center; vertical-align:middle" %)1 to 65535|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)Set by P07-06
1617
1618 (% class="table-bordered" %)
1619 |(% rowspan="2" style="text-align:center; vertical-align:middle; width:79px" %)**P07-65**|(% style="text-align:center; vertical-align:middle; width:242px" %)**Parameter name**|(% style="text-align:center; vertical-align:middle; width:152px" %)**Setting method**|(% style="text-align:center; vertical-align:middle; width:177px" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
1620 |(% style="text-align:center; vertical-align:middle; width:242px" %)(((
1621 The 15th segment displacement
1622 )))|(% style="text-align:center; vertical-align:middle; width:152px" %)Operation setting|(% style="text-align:center; vertical-align:middle; width:177px" %)Effective immediately|(% style="text-align:center; vertical-align:middle" %)10000|(% style="text-align:center; vertical-align:middle" %)-2147483647 to 2147483646|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)-
1623
1624 (% class="table-bordered" %)
1625 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**P07-66**|(% style="text-align:center; vertical-align:middle" %)**Parameter name**|(% style="text-align:center; vertical-align:middle" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
1626 |(% style="text-align:center; vertical-align:middle" %)Maximum speed of the 15th segment displacement|(% style="text-align:center; vertical-align:middle" %)Operation setting|(% style="text-align:center; vertical-align:middle" %)Effective immediately|(% style="text-align:center; vertical-align:middle" %)100|(% style="text-align:center; vertical-align:middle" %)1 to 5000|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)rpm
1627
1628 (% class="table-bordered" %)
1629 |(% rowspan="2" style="text-align:center; vertical-align:middle; width:77px" %)**P07-67**|(% style="text-align:center; vertical-align:middle; width:495px" %)**Parameter name**|(% style="text-align:center; vertical-align:middle" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
1630 |(% style="text-align:center; vertical-align:middle; width:495px" %)Acceleration and deceleration time of the 15th segment displacement|(% style="text-align:center; vertical-align:middle" %)Operation setting|(% style="text-align:center; vertical-align:middle" %)Effective immediately|(% style="text-align:center; vertical-align:middle" %)100|(% style="text-align:center; vertical-align:middle" %)1 to 65535|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)ms
1631
1632 (% class="table-bordered" %)
1633 |(% rowspan="2" style="text-align:center; vertical-align:middle; width:75px" %)**P07-68**|(% style="text-align:center; vertical-align:middle; width:448px" %)**Parameter name**|(% style="text-align:center; vertical-align:middle" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
1634 |(% style="text-align:center; vertical-align:middle; width:448px" %)Waiting time after completion of the 15th segment displacement|(% style="text-align:center; vertical-align:middle" %)Operation setting|(% style="text-align:center; vertical-align:middle" %)Effective immediately|(% style="text-align:center; vertical-align:middle" %)100|(% style="text-align:center; vertical-align:middle" %)1 to 65535|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)Set by P07-06
1635
1636 (% class="table-bordered" %)
1637 |(% rowspan="2" style="text-align:center; vertical-align:middle; width:77px" %)**P07-69**|(% style="text-align:center; vertical-align:middle; width:231px" %)**Parameter name**|(% style="text-align:center; vertical-align:middle; width:133px" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
1638 |(% style="text-align:center; vertical-align:middle; width:231px" %)(((
1639 The 16th segment displacement
1640 )))|(% style="text-align:center; vertical-align:middle; width:133px" %)Operation setting|(% style="text-align:center; vertical-align:middle" %)Effective immediately|(% style="text-align:center; vertical-align:middle" %)10000|(% style="text-align:center; vertical-align:middle" %)-2147483647 to 2147483646|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)-
1641
1642 (% class="table-bordered" %)
1643 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**P07-70**|(% style="text-align:center; vertical-align:middle" %)**Parameter name**|(% style="text-align:center; vertical-align:middle" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
1644 |(% style="text-align:center; vertical-align:middle" %)Maximum speed of the 16th segment displacement|(% style="text-align:center; vertical-align:middle" %)Operation setting|(% style="text-align:center; vertical-align:middle" %)Effective immediately|(% style="text-align:center; vertical-align:middle" %)100|(% style="text-align:center; vertical-align:middle" %)1 to 5000|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)rpm
1645
1646 (% class="table-bordered" %)
1647 |(% rowspan="2" style="text-align:center; vertical-align:middle; width:76px" %)**P07-71**|(% style="text-align:center; vertical-align:middle; width:496px" %)**Parameter name**|(% style="text-align:center; vertical-align:middle" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
1648 |(% style="text-align:center; vertical-align:middle; width:496px" %)Acceleration and deceleration time of the 16th segment displacement|(% style="text-align:center; vertical-align:middle" %)Operation setting|(% style="text-align:center; vertical-align:middle" %)Effective immediately|(% style="text-align:center; vertical-align:middle" %)100|(% style="text-align:center; vertical-align:middle" %)1 to 65535|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)ms
1649
1650 (% class="table-bordered" %)
1651 |(% rowspan="2" style="text-align:center; vertical-align:middle; width:77px" %)**P07-72**|(% style="text-align:center; vertical-align:middle; width:446px" %)**Parameter name**|(% style="text-align:center; vertical-align:middle" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
1652 |(% style="text-align:center; vertical-align:middle; width:446px" %)Waiting time after completion of the 16th segment displacement|(% style="text-align:center; vertical-align:middle" %)Operation setting|(% style="text-align:center; vertical-align:middle" %)Effective immediately|(% style="text-align:center; vertical-align:middle" %)100|(% style="text-align:center; vertical-align:middle" %)1 to 65535|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)Set by P07-06
1653
1654 = **Group P10 Accessibility** =
1655
1656 (% class="table-bordered" %)
1657 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**P10-01**|(% style="text-align:center; vertical-align:middle" %)**Parameter name**|(% style="text-align:center; vertical-align:middle" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
1658 |(% style="text-align:center; vertical-align:middle" %)JOG speed|(% style="text-align:center; vertical-align:middle" %)Operation setting|(% style="text-align:center; vertical-align:middle" %)Effective immediately|(% style="text-align:center; vertical-align:middle" %)100|(% style="text-align:center; vertical-align:middle" %)0 to 3000|(% style="text-align:center; vertical-align:middle" %)Accessibility|(% style="text-align:center; vertical-align:middle" %)ms
1659 |(% colspan="8" %)Used to set JOG speed
1660
1661 (% class="table-bordered" %)
1662 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**P10-02**|(% style="text-align:center; vertical-align:middle" %)**Parameter name**|(% style="text-align:center; vertical-align:middle" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
1663 |(% style="text-align:center; vertical-align:middle" %)Factory reset|(% style="text-align:center; vertical-align:middle" %)Shutdown setting|(% style="text-align:center; vertical-align:middle" %)Effective immediately|(% style="text-align:center; vertical-align:middle" %)0|(% style="text-align:center; vertical-align:middle" %)0 to 1|(% style="text-align:center; vertical-align:middle" %)Accessibility|(% style="text-align:center; vertical-align:middle" %)-
1664 |(% colspan="8" %)Write 1 to factory reset
1665
1666 (% class="table-bordered" %)
1667 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**P10-03**|(% style="text-align:center; vertical-align:middle" %)**Parameter name**|(% style="text-align:center; vertical-align:middle" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
1668 |(% style="text-align:center; vertical-align:middle" %)Fault clearing|(% style="text-align:center; vertical-align:middle" %)Operation setting|(% style="text-align:center; vertical-align:middle" %)Effective immediately|(% style="text-align:center; vertical-align:middle" %)0|(% style="text-align:center; vertical-align:middle" %)0 to 1|(% style="text-align:center; vertical-align:middle" %)Accessibility|(% style="text-align:center; vertical-align:middle" %)-
1669 |(% colspan="8" %)(((
1670 Fault reset operation selection
1671
1672 (% class="table-bordered" %)
1673 |(% style="text-align:center; vertical-align:middle; width:96px" %)**Set value**|(% style="text-align:center; vertical-align:middle; width:138px" %)**Function**|(% style="text-align:center; vertical-align:middle; width:926px" %)**Remarks**
1674 |(% style="text-align:center; vertical-align:middle; width:96px" %)0|(% style="width:138px" %)No operation|(% style="width:926px" %)-
1675 |(% style="text-align:center; vertical-align:middle; width:96px" %)1|(% style="width:138px" %)Fault clearing|(% style="width:926px" %)For clearable faults, after the cause of fault is removed, and write 1 to the function code, the drive will stop the fault display and enter the Rdy (or RUN) state again.
1676
1677 ✎**Note:** If the servo S-ON is valid, when the fault is removed and cleared, the servo will directly enter “Run” state. When performing fault clearing actions, please be sure to stop sending control instructions such as pulses to ensure personal safety.
1678 )))
1679
1680 (% class="table-bordered" %)
1681 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**P10-04**|(% style="text-align:center; vertical-align:middle; width:333px" %)**Parameter name**|(% style="text-align:center; vertical-align:middle; width:188px" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
1682 |(% style="text-align:center; vertical-align:middle; width:333px" %)Motor overload protection time factor|(% style="text-align:center; vertical-align:middle; width:188px" %)Operation setting|(% style="text-align:center; vertical-align:middle" %)Effective immediately|(% style="text-align:center; vertical-align:middle" %)100|(% style="text-align:center; vertical-align:middle" %)0 to 800|(% style="text-align:center; vertical-align:middle" %)Accessibility|(% style="text-align:center; vertical-align:middle" %)%
1683 |(% colspan="8" %)(((
1684 Set the time for code A-82 (Motor overload warning) and Er.34 (Motor overload protection fault) through this function code.
1685
1686 According to the heating condition of the motor, modifying this value could make the overload protection time fluctuate up and down the reference value. 50 corresponds to 50%, that is, the time is reduced by half; 300 corresponds to 300%, that is, the time is extended to 3 times.
1687 )))
1688
1689 (% class="table-bordered" %)
1690 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**P10-05**|(% style="text-align:center; vertical-align:middle" %)**Parameter name**|(% style="text-align:center; vertical-align:middle" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
1691 |(% style="text-align:center; vertical-align:middle" %)Motor model|(% style="text-align:center; vertical-align:middle" %)Operation setting|(% style="text-align:center; vertical-align:middle" %)Power-on again|(% style="text-align:center; vertical-align:middle" %)0|(% style="text-align:center; vertical-align:middle" %)0 to 65535|(% style="text-align:center; vertical-align:middle" %)Accessibility|(% style="text-align:center; vertical-align:middle" %)-
1692 |(% colspan="8" %)(((
1693 This function code displays the motor code code of the motor currently recognized by the servo drive (including the last successful recognition).
1694
1695 ✎**Note:** It is necessary to connect the motor first, and then power on the drive. Otherwise, it will report “Er.27” (encoder disconnection fault) .
1696 )))
1697
1698 (% class="table-bordered" %)
1699 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**P10-06**|(% style="text-align:center; vertical-align:middle" %)**Parameter name**|(% style="text-align:center; vertical-align:middle" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
1700 |(% style="text-align:center; vertical-align:middle" %)Multi-turn absolute encoder reset|(% style="text-align:center; vertical-align:middle" %)Shutdown setting|(% style="text-align:center; vertical-align:middle" %)Effective immediately|(% style="text-align:center; vertical-align:middle" %)0|(% style="text-align:center; vertical-align:middle" %)0 to 1|(% style="text-align:center; vertical-align:middle" %)Accessibility|(% style="text-align:center; vertical-align:middle" %)-
1701 |(% colspan="8" %)(((
1702 Used to clear the rotation number of multi-turn absolute encoder (U0-55), current position (U0-56) or clear the encoder fault alarms
1703
1704 (% class="table-bordered" %)
1705 |(% style="text-align:center; vertical-align:middle" %)**Set value**|(% style="text-align:center; vertical-align:middle" %)**Function**
1706 |(% style="text-align:center; vertical-align:middle" %)0|No operation;
1707 |(% style="text-align:center; vertical-align:middle" %)1|Clear multi-turn data, encoder current position and encoder fault alarms
1708
1709 ✎**Note:** After reset (P10-06 is set to 1), the absolute position of the encoder will change suddenly, and the mechanical origin return operation is required.
1710 )))
1711
1712 = **Group P12 Communication parameters** =
1713
1714 (% class="table-bordered" %)
1715 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**P12-01**|(% style="text-align:center; vertical-align:middle" %)**Parameter name**|(% style="text-align:center; vertical-align:middle" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
1716 |(% style="text-align:center; vertical-align:middle" %)Servo address|(% style="text-align:center; vertical-align:middle" %)Operation setting|(% style="text-align:center; vertical-align:middle" %)Effective immediately|(% style="text-align:center; vertical-align:middle" %)1|(% style="text-align:center; vertical-align:middle" %)1 to 247|(% style="text-align:center; vertical-align:middle" %)Communication parameter|(% style="text-align:center; vertical-align:middle" %)-
1717 |(% colspan="8" %)Set the Modbus communication address of servo drive
1718
1719 (% class="table-bordered" %)
1720 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**P12-02**|(% style="text-align:center; vertical-align:middle" %)**Parameter name**|(% style="text-align:center; vertical-align:middle" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
1721 |(% style="text-align:center; vertical-align:middle" %)Baud rate|(% style="text-align:center; vertical-align:middle" %)Operation setting|(% style="text-align:center; vertical-align:middle" %)Effective immediately|(% style="text-align:center; vertical-align:middle" %)2|(% style="text-align:center; vertical-align:middle" %)0 to 5|(% style="text-align:center; vertical-align:middle" %)Communication parameter|(% style="text-align:center; vertical-align:middle" %)-
1722 |(% colspan="8" %)Set the communication rate between servo drive and Modbus software. The communication rate of the servo drive must be consistent with that of the ModBus software, otherwise it could not communicate.(((
1723 (% class="table-bordered" %)
1724 |(% style="text-align:center; vertical-align:middle" %)**Set value**|(% style="text-align:center; vertical-align:middle" %)**Baud rate setting**|(% style="text-align:center; vertical-align:middle" %)**Set value**|(% style="text-align:center; vertical-align:middle" %)**Baud rate setting**
1725 |(% style="text-align:center; vertical-align:middle" %)0|(% style="text-align:center; vertical-align:middle" %)2400 bps|(% style="text-align:center; vertical-align:middle" %)3|(% style="text-align:center; vertical-align:middle" %)19200 bps
1726 |(% style="text-align:center; vertical-align:middle" %)1|(% style="text-align:center; vertical-align:middle" %)4800 bps|(% style="text-align:center; vertical-align:middle" %)4|(% style="text-align:center; vertical-align:middle" %)38400 bps
1727 |(% style="text-align:center; vertical-align:middle" %)2|(% style="text-align:center; vertical-align:middle" %)9600 bps|(% style="text-align:center; vertical-align:middle" %)5|(% style="text-align:center; vertical-align:middle" %)57600 bps
1728 )))
1729
1730 (% class="table-bordered" %)
1731 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**P12-03**|(% style="text-align:center; vertical-align:middle" %)**Parameter name**|(% style="text-align:center; vertical-align:middle" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
1732 |(% style="text-align:center; vertical-align:middle" %)Serial data format|(% style="text-align:center; vertical-align:middle" %)Operation setting|(% style="text-align:center; vertical-align:middle" %)Effective immediately|(% style="text-align:center; vertical-align:middle" %)0|(% style="text-align:center; vertical-align:middle" %)0 to 3|(% style="text-align:center; vertical-align:middle" %)Communication parameter|(% style="text-align:center; vertical-align:middle" %)-
1733 |(% colspan="8" %)Used to set the data verification mode when the servo drive communicates with ModBus. The data format of servo drive must be consistent with that of the ModBus software, otherwise it could not communicate.(((
1734 (% class="table-bordered" %)
1735 |(% style="text-align:center; vertical-align:middle" %)**Set value**|(% style="text-align:center; vertical-align:middle" %)**Data format**
1736 |(% style="text-align:center; vertical-align:middle" %)0|(% style="text-align:center; vertical-align:middle" %)1 stop bit, no parity
1737 |(% style="text-align:center; vertical-align:middle" %)1|(% style="text-align:center; vertical-align:middle" %)1 stop bit, odd parity
1738 |(% style="text-align:center; vertical-align:middle" %)2|(% style="text-align:center; vertical-align:middle" %)1 stop bit, even parity
1739 |(% style="text-align:center; vertical-align:middle" %)3|(% style="text-align:center; vertical-align:middle" %)2 stop bits, no parity
1740 )))
1741
1742 (% class="table-bordered" %)
1743 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**P12-04**|(% style="text-align:center; vertical-align:middle; width:328px" %)**Parameter name**|(% style="text-align:center; vertical-align:middle; width:165px" %)**Setting method**|(% style="text-align:center; vertical-align:middle; width:205px" %)**Effective time**|(% style="text-align:center; vertical-align:middle; width:95px" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
1744 |(% style="text-align:center; vertical-align:middle; width:328px" %)(((
1745 Write Modbus communication data to EEPROM
1746 )))|(% style="text-align:center; vertical-align:middle; width:165px" %)Operation setting|(% style="text-align:center; vertical-align:middle; width:205px" %)Effective immediately|(% style="text-align:center; vertical-align:middle; width:95px" %)0|(% style="text-align:center; vertical-align:middle" %)0 to 1|(% style="text-align:center; vertical-align:middle" %)Communication parameter|(% style="text-align:center; vertical-align:middle" %)-
1747 |(% colspan="8" %)(((
1748 Whether the function code written by the communication method is saved to EEPRO
1749
1750 (% class="table-bordered" %)
1751 |(% style="text-align:center; vertical-align:middle" %)**Set value**|(% style="text-align:center; vertical-align:middle" %)**Whether the function code written by the communication method is saved to EEPROM**
1752 |(% style="text-align:center; vertical-align:middle" %)0|Do not write to EEPROM, and do not save data after power failure;
1753 |(% style="text-align:center; vertical-align:middle" %)1|Write to EEPROM, and save data after power failure;
1754
1755 ✎**Note:** If you need to change the function code value frequently, it is recommended to set the function code to 0, otherwise the EEPROM would be damaged due to frequent erase of EEPROM. “Er.02” (Parameter Storage Error) will occur on the servo drive.
1756 )))
1757
1758 (% class="table-bordered" %)
1759 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)(((
1760 **P12-05**
1761
1762
1763 )))|(% style="text-align:center; vertical-align:middle" %)**Parameter name**|(% style="text-align:center; vertical-align:middle" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
1764 |(% style="text-align:center; vertical-align:middle" %)RS422/RS485 function selection|(% style="text-align:center; vertical-align:middle" %)Operation setting|(% style="text-align:center; vertical-align:middle" %)Effective immediately|(% style="text-align:center; vertical-align:middle" %)0|(% style="text-align:center; vertical-align:middle" %)0 to 1|(% style="text-align:center; vertical-align:middle" %)Communication parameter|(% style="text-align:center; vertical-align:middle" %)-
1765 |(% colspan="8" %)(((
1766 Used to set the communication method of VD2F servo drive (The CN3 and CN4 of VD2F are time division multiplexing communication ports, and support RS422 and RS485 time division multiplexing)
1767
1768 (% class="table-bordered" %)
1769 |(% style="text-align:center; vertical-align:middle" %)**Set value**|(% style="text-align:center; vertical-align:middle" %)**Communication method**
1770 |(% style="text-align:center; vertical-align:middle" %)0|(% style="text-align:center; vertical-align:middle" %)RS422 communication
1771 |(% style="text-align:center; vertical-align:middle" %)1|(% style="text-align:center; vertical-align:middle" %)RS485 communication
1772
1773 ✎**Note:** **“☆”** indicates that only VD2F servo drive support this function code. The VD2-0XXSA1G model does not have this function code.
1774 )))
1775
1776 = **Group P13 Communication input and output terminal** =
1777
1778 (% class="table-bordered" %)
1779 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**P13-01**|(% style="text-align:center; vertical-align:middle" %)**Parameter name**|(% style="text-align:center; vertical-align:middle" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
1780 |(% style="text-align:center; vertical-align:middle" %)Virtual VDI_1 input value|(% style="text-align:center; vertical-align:middle" %)Operation setting|(% style="text-align:center; vertical-align:middle" %)Effective immediately|(% style="text-align:center; vertical-align:middle" %)0|(% style="text-align:center; vertical-align:middle" %)0 to 1|(% style="text-align:center; vertical-align:middle" %)DI/DO|(% style="text-align:center; vertical-align:middle" %)-
1781 |(% colspan="8" %)When P06-04 is set to 1, DI_1 channel logic is controlled by this function code.(((
1782 (% class="table-bordered" %)
1783 |(% style="text-align:center; vertical-align:middle" %)**Set value**|(% style="text-align:center; vertical-align:middle" %)**VDI_1 input level**
1784 |(% style="text-align:center; vertical-align:middle" %)0|(% style="text-align:center; vertical-align:middle" %)High level
1785 |(% style="text-align:center; vertical-align:middle" %)1|(% style="text-align:center; vertical-align:middle" %)Low level
1786 )))
1787
1788 (% class="table-bordered" %)
1789 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**P13-02**|(% style="text-align:center; vertical-align:middle" %)**Parameter name**|(% style="text-align:center; vertical-align:middle" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
1790 |(% style="text-align:center; vertical-align:middle" %)Virtual VDI_2 input value|(% style="text-align:center; vertical-align:middle" %)Operation setting|(% style="text-align:center; vertical-align:middle" %)Effective immediately|(% style="text-align:center; vertical-align:middle" %)0|(% style="text-align:center; vertical-align:middle" %)0 to 1|(% style="text-align:center; vertical-align:middle" %)DI/DO|(% style="text-align:center; vertical-align:middle" %)-
1791 |(% colspan="8" %)When P06-07 is set to 1, DI_2 channel logic is controlled by this function code.
1792
1793 (% class="table-bordered" %)
1794 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**P13-03**|(% style="text-align:center; vertical-align:middle" %)**Parameter name**|(% style="text-align:center; vertical-align:middle" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
1795 |(% style="text-align:center; vertical-align:middle" %)Virtual VDI_3 input value|(% style="text-align:center; vertical-align:middle" %)Operation setting|(% style="text-align:center; vertical-align:middle" %)Effective immediately|(% style="text-align:center; vertical-align:middle" %)0|(% style="text-align:center; vertical-align:middle" %)0 to 1|(% style="text-align:center; vertical-align:middle" %)DI/DO|(% style="text-align:center; vertical-align:middle" %)-
1796 |(% colspan="8" %)When P06-10 is set to 1, DI_3 channel logic is controlled by this function code.
1797
1798 (% class="table-bordered" %)
1799 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**P13-04**|(% style="text-align:center; vertical-align:middle" %)**Parameter name**|(% style="text-align:center; vertical-align:middle" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
1800 |(% style="text-align:center; vertical-align:middle" %)Virtual VDI_2 input value|(% style="text-align:center; vertical-align:middle" %)Operation setting|(% style="text-align:center; vertical-align:middle" %)Effective immediately|(% style="text-align:center; vertical-align:middle" %)0|(% style="text-align:center; vertical-align:middle" %)0 to 1|(% style="text-align:center; vertical-align:middle" %)DI/DO|(% style="text-align:center; vertical-align:middle" %)-
1801 |(% colspan="8" %)When P06-13 is set to 1, DI_4 channel logic is controlled by this function code.
1802
1803 (% class="table-bordered" %)
1804 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**P13-05**|(% style="text-align:center; vertical-align:middle" %)**Parameter name**|(% style="text-align:center; vertical-align:middle" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
1805 |(% style="text-align:center; vertical-align:middle" %)Virtual VDI_5 input value|(% style="text-align:center; vertical-align:middle" %)Operation setting|(% style="text-align:center; vertical-align:middle" %)Effective immediately|(% style="text-align:center; vertical-align:middle" %)0|(% style="text-align:center; vertical-align:middle" %)0 to 1|(% style="text-align:center; vertical-align:middle" %)DI/DO|(% style="text-align:center; vertical-align:middle" %)-
1806 |(% colspan="8" %)When P06-16 is set to 1, DI_5 channel logic is controlled by this function code.
1807
1808 (% class="table-bordered" %)
1809 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)(((
1810 **P13-06**
1811
1812
1813 )))|(% style="text-align:center; vertical-align:middle" %)**Parameter name**|(% style="text-align:center; vertical-align:middle" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
1814 |(% style="text-align:center; vertical-align:middle" %)Virtual VDI_6 input value|(% style="text-align:center; vertical-align:middle" %)Operation setting|(% style="text-align:center; vertical-align:middle" %)Effective immediately|(% style="text-align:center; vertical-align:middle" %)0|(% style="text-align:center; vertical-align:middle" %)0 to 1|(% style="text-align:center; vertical-align:middle" %)DI/DO|(% style="text-align:center; vertical-align:middle" %)-
1815 |(% colspan="8" %)(((
1816 When P06-19 is set to 1, DI_6 channel logic is controlled by this function code.
1817
1818 “☆” indicates that the VD2F servo drive does not support this function code.
1819 )))
1820
1821 (% class="table-bordered" %)
1822 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)(((
1823 **P13-07**
1824
1825
1826 )))|(% style="text-align:center; vertical-align:middle" %)**Parameter name**|(% style="text-align:center; vertical-align:middle" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
1827 |(% style="text-align:center; vertical-align:middle" %)Virtual VDI_7 input value|(% style="text-align:center; vertical-align:middle" %)Operation setting|(% style="text-align:center; vertical-align:middle" %)Effective immediately|(% style="text-align:center; vertical-align:middle" %)0|(% style="text-align:center; vertical-align:middle" %)0 to 1|(% style="text-align:center; vertical-align:middle" %)DI/DO|(% style="text-align:center; vertical-align:middle" %)-
1828 |(% colspan="8" %)(((
1829 When P06-22 is set to 1, DI_7 channel logic is controlled by this function code.
1830
1831 “☆” indicates that the VD2F servo drive does not support this function code.
1832 )))
1833
1834 (% class="table-bordered" %)
1835 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)(((
1836 **P13-08**
1837
1838
1839 )))|(% style="text-align:center; vertical-align:middle" %)**Parameter name**|(% style="text-align:center; vertical-align:middle" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
1840 |(% style="text-align:center; vertical-align:middle" %)Virtual VDI_8 input value|(% style="text-align:center; vertical-align:middle" %)Operation setting|(% style="text-align:center; vertical-align:middle" %)Effective immediately|(% style="text-align:center; vertical-align:middle" %)0|(% style="text-align:center; vertical-align:middle" %)0 to 1|(% style="text-align:center; vertical-align:middle" %)DI/DO|(% style="text-align:center; vertical-align:middle" %)-
1841 |(% colspan="8" %)(((
1842 When P06-25 is set to 1, DI_8 channel logic is controlled by this function code.
1843
1844 “☆” indicates that the VD2F servo drive does not support this function code.
1845 )))
1846
1847 (% class="table-bordered" %)
1848 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**P13-11**|(% style="text-align:center; vertical-align:middle" %)**Parameter name**|(% style="text-align:center; vertical-align:middle" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
1849 |(% style="text-align:center; vertical-align:middle" %)Virtual VDO_1 input value|(% style="text-align:center; vertical-align:middle" %)Operation setting|(% style="text-align:center; vertical-align:middle" %)Effective immediately|(% style="text-align:center; vertical-align:middle" %)0|(% style="text-align:center; vertical-align:middle" %)0 to 1|(% style="text-align:center; vertical-align:middle" %)DI/DO|(% style="text-align:center; vertical-align:middle" %)-
1850 |(% colspan="8" %)Used to set the input level logic when the DO function selected by VDO_1 is valid(((
1851 (% class="table-bordered" %)
1852 |(% style="text-align:center; vertical-align:middle" %)**Set value**|(% style="text-align:center; vertical-align:middle" %)**VDo_1 input level**
1853 |(% style="text-align:center; vertical-align:middle" %)0|(% style="text-align:center; vertical-align:middle" %)High level
1854 |(% style="text-align:center; vertical-align:middle" %)1|(% style="text-align:center; vertical-align:middle" %)Low level
1855 )))
1856
1857 (% class="table-bordered" %)
1858 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**P13-12**|(% style="text-align:center; vertical-align:middle" %)**Parameter name**|(% style="text-align:center; vertical-align:middle" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
1859 |(% style="text-align:center; vertical-align:middle" %)Virtual VD0_2 input value|(% style="text-align:center; vertical-align:middle" %)Operation setting|(% style="text-align:center; vertical-align:middle" %)Effective immediately|(% style="text-align:center; vertical-align:middle" %)0|(% style="text-align:center; vertical-align:middle" %)0 to 1|(% style="text-align:center; vertical-align:middle" %)DI/DO|(% style="text-align:center; vertical-align:middle" %)-
1860
1861 (% class="table-bordered" %)
1862 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**P13-13**|(% style="text-align:center; vertical-align:middle" %)**Parameter name**|(% style="text-align:center; vertical-align:middle" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
1863 |(% style="text-align:center; vertical-align:middle" %)Virtual VD0_3 input value|(% style="text-align:center; vertical-align:middle" %)Operation setting|(% style="text-align:center; vertical-align:middle" %)Effective immediately|(% style="text-align:center; vertical-align:middle" %)0|(% style="text-align:center; vertical-align:middle" %)0 to 1|(% style="text-align:center; vertical-align:middle" %)DI/DO|(% style="text-align:center; vertical-align:middle" %)-
1864
1865 (% class="table-bordered" %)
1866 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**P13-14**|(% style="text-align:center; vertical-align:middle" %)**Parameter name**|(% style="text-align:center; vertical-align:middle" %)**Setting method**|(% style="text-align:center; vertical-align:middle" %)**Effective time**|(% style="text-align:center; vertical-align:middle" %)**Default**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Unit**
1867 |(% style="text-align:center; vertical-align:middle" %)Virtual VD0_4 input value|(% style="text-align:center; vertical-align:middle" %)Operation setting|(% style="text-align:center; vertical-align:middle" %)Effective immediately|(% style="text-align:center; vertical-align:middle" %)0|(% style="text-align:center; vertical-align:middle" %)0 to 1|(% style="text-align:center; vertical-align:middle" %)DI/DO|(% style="text-align:center; vertical-align:middle" %)-
1868
1869 = **Group U0 Universal monitoring** =
1870
1871 (% class="table-bordered" %)
1872 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**U0-01**|(% style="text-align:center; vertical-align:middle" %)**Monitoring name**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Panel display**|(% style="text-align:center; vertical-align:middle" %)**Unit**|(% style="text-align:center; vertical-align:middle" %)**Data type**
1873 |(% style="text-align:center; vertical-align:middle" %)Servo status|(% style="text-align:center; vertical-align:middle" %)1 to 4|(% style="text-align:center; vertical-align:middle" %)Universal|(% style="text-align:center; vertical-align:middle" %)Decimal|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)16-bit
1874 |(% colspan="7" %)Display the status of servo drive.(((
1875 (% class="table-bordered" %)
1876 |(% style="text-align:center; vertical-align:middle" %)**Display value**|(% style="text-align:center; vertical-align:middle" %)**Status**|(% style="text-align:center; vertical-align:middle" %)**Display value**|(% style="text-align:center; vertical-align:middle" %)**Status**
1877 |(% style="text-align:center; vertical-align:middle" %)1|(% style="text-align:center; vertical-align:middle" %)Initialization|(% style="text-align:center; vertical-align:middle" %)3|(% style="text-align:center; vertical-align:middle" %)Run
1878 |(% style="text-align:center; vertical-align:middle" %)2|(% style="text-align:center; vertical-align:middle" %)Rdy and JOG|(% style="text-align:center; vertical-align:middle" %)4|(% style="text-align:center; vertical-align:middle" %)Fault
1879 )))
1880
1881 (% class="table-bordered" %)
1882 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**U0-02**|(% style="text-align:center; vertical-align:middle" %)**Monitoring name**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Panel display**|(% style="text-align:center; vertical-align:middle" %)**Unit**|(% style="text-align:center; vertical-align:middle" %)**Data type**
1883 |(% style="text-align:center; vertical-align:middle" %)Servo motor speed|(% style="text-align:center; vertical-align:middle" %)-5000 to 5000|(% style="text-align:center; vertical-align:middle" %)Universal|(% style="text-align:center; vertical-align:middle" %)Decimal|(% style="text-align:center; vertical-align:middle" %)rpm|(% style="text-align:center; vertical-align:middle" %)16-bit
1884 |(% colspan="7" %)Display the actual speed of servo drive. The accuracy is 1 rpm. The display of servo drive panel is as below.(((
1885 (% class="table-bordered" %)
1886 |(% style="text-align:center; vertical-align:middle; width:576px" %)500 rpm display|(% style="text-align:center; vertical-align:middle; width:584px" %)-500 rpm display
1887 |(% style="text-align:center; vertical-align:middle; width:576px" %)[[image:http://docs.we-con.com.cn/wiki/servo/download/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/WebHome/Wecon%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29_html_1f240ce417f0d67b.gif?rev=1.1||alt="Wecon VD2 SA Series Servo Drives Manual (Full V1.1)_html_1f240ce417f0d67b.gif"]]|(% style="text-align:center; vertical-align:middle; width:584px" %)[[image:http://docs.we-con.com.cn/wiki/servo/download/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/WebHome/Wecon%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29_html_7d756cf7cdf4bcb9.gif?rev=1.1||alt="Wecon VD2 SA Series Servo Drives Manual (Full V1.1)_html_7d756cf7cdf4bcb9.gif"]]
1888 )))
1889
1890 (% class="table-bordered" %)
1891 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**U0-03**|(% style="text-align:center; vertical-align:middle; width:273px" %)**Monitoring name**|(% style="text-align:center; vertical-align:middle; width:209px" %)**Range**|(% style="text-align:center; vertical-align:middle; width:160px" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Panel display**|(% style="text-align:center; vertical-align:middle" %)**Unit**|(% style="text-align:center; vertical-align:middle" %)**Data type**
1892 |(% style="text-align:center; vertical-align:middle; width:273px" %)Input speed instruction|(% style="text-align:center; vertical-align:middle; width:209px" %)-5000 to 5000|(% style="text-align:center; vertical-align:middle; width:160px" %)Universal|(% style="text-align:center; vertical-align:middle" %)Decimal|(% style="text-align:center; vertical-align:middle" %)rpm|(% style="text-align:center; vertical-align:middle" %)16-bit
1893 |(% colspan="7" %)Display input speed instruction. The accuracy is 1 rpm. The display of servo drive panel is as below.(((
1894 (% class="table-bordered" %)
1895 |(% style="text-align:center; vertical-align:middle" %)3000 rpm display|(% style="text-align:center; vertical-align:middle" %)-3000 rpm display
1896 |(% style="text-align:center; vertical-align:middle" %)[[image:http://docs.we-con.com.cn/wiki/servo/download/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/WebHome/Wecon%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29_html_ef89879c3fe06a09.gif?rev=1.1||alt="Wecon VD2 SA Series Servo Drives Manual (Full V1.1)_html_ef89879c3fe06a09.gif"]]|(% style="text-align:center; vertical-align:middle" %)[[image:http://docs.we-con.com.cn/wiki/servo/download/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/WebHome/Wecon%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29_html_eb1e0ee021f5cc6c.gif?rev=1.1||alt="Wecon VD2 SA Series Servo Drives Manual (Full V1.1)_html_eb1e0ee021f5cc6c.gif"]]
1897 )))
1898
1899 (% class="table-bordered" %)
1900 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**U0-04**|(% style="text-align:center; vertical-align:middle; width:336px" %)**Monitoring name**|(% style="text-align:center; vertical-align:middle; width:208px" %)**Range**|(% style="text-align:center; vertical-align:middle; width:193px" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Panel display**|(% style="text-align:center; vertical-align:middle" %)**Unit**|(% style="text-align:center; vertical-align:middle" %)**Data type**
1901 |(% style="text-align:center; vertical-align:middle; width:336px" %)Corresponding speed of position instruction|(% style="text-align:center; vertical-align:middle; width:208px" %)-5000 to 5000|(% style="text-align:center; vertical-align:middle; width:193px" %)Universal|(% style="text-align:center; vertical-align:middle" %)Decimal|(% style="text-align:center; vertical-align:middle" %)rpm|(% style="text-align:center; vertical-align:middle" %)16-bit
1902 |(% colspan="7" %)Display the current speed instruction value of servo drive in position mode. The accuracy is 1 rpm. The display of servo drive panel is as below.(((
1903 (% class="table-bordered" %)
1904 |(% style="text-align:center; vertical-align:middle" %)3000 rpm display|(% style="text-align:center; vertical-align:middle" %)-3000 rpm display
1905 |(% style="text-align:center; vertical-align:middle" %)[[image:http://docs.we-con.com.cn/wiki/servo/download/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/WebHome/Wecon%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29_html_ef89879c3fe06a09.gif?rev=1.1||alt="Wecon VD2 SA Series Servo Drives Manual (Full V1.1)_html_ef89879c3fe06a09.gif"]]|(% style="text-align:center; vertical-align:middle" %)[[image:http://docs.we-con.com.cn/wiki/servo/download/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/WebHome/Wecon%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29_html_eb1e0ee021f5cc6c.gif?rev=1.1||alt="Wecon VD2 SA Series Servo Drives Manual (Full V1.1)_html_eb1e0ee021f5cc6c.gif"]]
1906 )))
1907
1908 (% class="table-bordered" %)
1909 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**U0-05**|(% style="text-align:center; vertical-align:middle" %)**Monitoring name**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle; width:141px" %)**Category**|(% style="text-align:center; vertical-align:middle; width:153px" %)**Panel display**|(% style="text-align:center; vertical-align:middle" %)**Unit**|(% style="text-align:center; vertical-align:middle" %)**Data type**
1910 |(% style="text-align:center; vertical-align:middle" %)Pulse deviation|(% style="text-align:center; vertical-align:middle" %)-2^^31^^ to 2^^31^^|(% style="text-align:center; vertical-align:middle; width:141px" %)Universal|(% style="text-align:center; vertical-align:middle; width:153px" %)Decimal|(% style="text-align:center; vertical-align:middle" %)(((
1911 Equivalent pulse deviation
1912 )))|(% style="text-align:center; vertical-align:middle" %)32-bit
1913 |(% colspan="7" style="text-align:center; vertical-align:middle" %)(((
1914 Display pulse deviation. If U0-05 is set to 32768, the display of servo drive panel is as below.
1915
1916 [[image:image-20220608162142-14.png]]
1917 )))
1918
1919 (% class="table-bordered" %)
1920 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**U0-08**|(% style="text-align:center; vertical-align:middle; width:357px" %)**Monitoring name**|(% style="text-align:center; vertical-align:middle; width:149px" %)**Range**|(% style="text-align:center; vertical-align:middle; width:151px" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Panel display**|(% style="text-align:center; vertical-align:middle" %)**Unit**|(% style="text-align:center; vertical-align:middle" %)**Data type**
1921 |(% style="text-align:center; vertical-align:middle; width:357px" %)Input instruction pulse frequency|(% style="text-align:center; vertical-align:middle; width:149px" %)-|(% style="text-align:center; vertical-align:middle; width:151px" %)Universal|(% style="text-align:center; vertical-align:middle" %)Decimal|(% style="text-align:center; vertical-align:middle" %)KHz|(% style="text-align:center; vertical-align:middle" %)16-bit
1922 |(% colspan="7" %)Display the input instruction pulse frequency of servo drive.
1923
1924 (% class="table-bordered" %)
1925 |(% rowspan="2" style="text-align:center; vertical-align:middle; width:120px" %)**U0-09**|(% style="text-align:center; vertical-align:middle; width:247px" %)**Monitoring name**|(% style="text-align:center; vertical-align:middle; width:163px" %)**Range**|(% style="text-align:center; vertical-align:middle; width:261px" %)**Category**|(% style="text-align:center; vertical-align:middle; width:368px" %)**Panel display**|(% style="text-align:center; vertical-align:middle; width:208px" %)**Unit**|(% style="text-align:center; vertical-align:middle; width:118px" %)**Data type**
1926 |(% style="text-align:center; vertical-align:middle; width:247px" %)Input instruction pulse number|(% style="text-align:center; vertical-align:middle; width:163px" %)-2^^31^^ to 2^^31^^|(% style="text-align:center; vertical-align:middle; width:261px" %)Universal|(% style="text-align:center; vertical-align:middle; width:368px" %)Decimal|(% style="text-align:center; vertical-align:middle; width:208px" %)(((
1927 Equivalent pulse deviation
1928 )))|(% style="text-align:center; vertical-align:middle; width:118px" %)32-bit
1929 |(% colspan="7" style="text-align:center; vertical-align:middle" %)(((
1930 Display instruction pulse number that input the servo drive. If U0-09 is set to -2147483646, the display of servo drive panel is as below.
1931
1932 [[image:image-20220608162219-15.png]]
1933 )))
1934
1935 (% class="table-bordered" %)
1936 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**U0-13**|(% style="text-align:center; vertical-align:middle; width:542px" %)**Monitoring name**|(% style="text-align:center; vertical-align:middle; width:167px" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Panel display**|(% style="text-align:center; vertical-align:middle" %)**Unit**|(% style="text-align:center; vertical-align:middle" %)**Data type**
1937 |(% style="text-align:center; vertical-align:middle; width:542px" %)(((
1938 Encoder cumulative position (Lower 32 bits)
1939 )))|(% style="text-align:center; vertical-align:middle; width:167px" %)-2^^31^^ to 2^^31^^|(% style="text-align:center; vertical-align:middle" %)Universal|(% style="text-align:center; vertical-align:middle" %)Decimal|(% style="text-align:center; vertical-align:middle" %)Encoder unit|(% style="text-align:center; vertical-align:middle" %)32-bit
1940
1941 (% class="table-bordered" %)
1942 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**U0-15**|(% style="text-align:center; vertical-align:middle" %)**Monitoring name**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Panel display**|(% style="text-align:center; vertical-align:middle" %)**Unit**|(% style="text-align:center; vertical-align:middle" %)**Data type**
1943 |(% style="text-align:center; vertical-align:middle" %)(((
1944 Encoder cumulative position (High 32 bits)
1945 )))|(% style="text-align:center; vertical-align:middle" %)-2^^31^^ to 2^^31^^|(% style="text-align:center; vertical-align:middle" %)Universal|(% style="text-align:center; vertical-align:middle" %)Decimal|(% style="text-align:center; vertical-align:middle" %)Encoder unit|(% style="text-align:center; vertical-align:middle" %)32-bit
1946 |(% colspan="7" %)Display the cumulative data of encoder position. It is used with U0-13 cooperatively.
1947
1948 (% class="table-bordered" %)
1949 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**U0-17**|(% style="text-align:center; vertical-align:middle" %)**Monitoring name**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Panel display**|(% style="text-align:center; vertical-align:middle" %)**Unit**|(% style="text-align:center; vertical-align:middle" %)**Data type**
1950 |(% style="text-align:center; vertical-align:middle" %)DI input signal status|(% style="text-align:center; vertical-align:middle" %)(((
1951 00000000 to 11111111
1952 )))|(% style="text-align:center; vertical-align:middle" %)Universal|(% style="text-align:center; vertical-align:middle" %)Binary|(% style="text-align:center; vertical-align:middle" %)Encoder unit|(% style="text-align:center; vertical-align:middle" %)16-bit
1953 |(% colspan="7" %)(((
1954 Display the current level status of DI terminal. The upper part of the digital tube of servo drive panel is lit up to indicate a high level (denoted by "1"). The lower part is lit up to indicate a low level (denoted by "0").
1955
1956 Take the DI1 to DI7 terminals as the high level and DI8 as the low level as an example. The corresponding binary code is "01111111", and Wecon servo control device debugging software U0-17 displays the current binary value is 0b0111 1111. The panel of servo drive is displayed as below.
1957
1958 (% style="text-align:center" %)
1959 [[image:http://docs.we-con.com.cn/wiki/servo/download/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/WebHome/Wecon%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29_html_68355f9b7754c4a3.gif?rev=1.1||alt="Wecon VD2 SA Series Servo Drives Manual (Full V1.1)_html_68355f9b7754c4a3.gif"]]
1960 )))
1961
1962 (% class="table-bordered" %)
1963 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**U0-19**|(% style="text-align:center; vertical-align:middle" %)**Monitoring name**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Panel display**|(% style="text-align:center; vertical-align:middle" %)**Unit**|(% style="text-align:center; vertical-align:middle" %)**Data type**
1964 |(% style="text-align:center; vertical-align:middle" %)DO output signal status|(% style="text-align:center; vertical-align:middle" %)(((
1965 00000000 to 00001111
1966 )))|(% style="text-align:center; vertical-align:middle" %)Universal|(% style="text-align:center; vertical-align:middle" %)Binary|(% style="text-align:center; vertical-align:middle" %)Encoder unit|(% style="text-align:center; vertical-align:middle" %)16-bit
1967 |(% colspan="7" %)(((
1968 Display the current level status of 4 DO terminals. The upper part of the digital tube of servo drive panel is lit up to indicate a high level (denoted by "1"). The lower part is lit up to indicate a low level (denoted by "0").
1969
1970 Take the DO1, DO2 and DO3 terminals as the high level and DO2 as the low level as an example. The corresponding binary code is "1101", and Wecon servo upper computer debugging software U0-17 displays the current binary value is 0b0000 1101. The panel of servo drive is displayed as below.
1971
1972 (% style="text-align:center" %)
1973 [[image:http://docs.we-con.com.cn/wiki/servo/download/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/WebHome/Wecon%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29_html_9abfc1e331ff152b.gif?rev=1.1||alt="Wecon VD2 SA Series Servo Drives Manual (Full V1.1)_html_9abfc1e331ff152b.gif"]]
1974 )))
1975
1976 (% class="table-bordered" %)
1977 |(% rowspan="2" style="text-align:center; vertical-align:middle; width:196px" %)**U0-20**|(% style="text-align:center; vertical-align:middle; width:359px" %)**Monitoring name**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Panel display**|(% style="text-align:center; vertical-align:middle" %)**Unit**|(% style="text-align:center; vertical-align:middle" %)**Data type**
1978 |(% style="text-align:center; vertical-align:middle; width:359px" %)Real-time load inertia ratio|(% style="text-align:center; vertical-align:middle" %)0 to 1000000|(% style="text-align:center; vertical-align:middle" %)Universal|(% style="text-align:center; vertical-align:middle" %)Decimal|(% style="text-align:center; vertical-align:middle" %)%|(% style="text-align:center; vertical-align:middle" %)16-bit
1979 |(% colspan="7" style="text-align:center; vertical-align:middle" %)(((
1980 Display the current load inertia ratio. If the load inertia ratio is 3 times (300%) , the panel of servo drive is displayed as below.
1981
1982 [[image:http://docs.we-con.com.cn/wiki/servo/download/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/WebHome/Wecon%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29_html_834425fb42ffed4f.gif?rev=1.1||alt="Wecon VD2 SA Series Servo Drives Manual (Full V1.1)_html_834425fb42ffed4f.gif"]]
1983 )))
1984
1985 (% class="table-bordered" %)
1986 |(% rowspan="3" style="text-align:center; vertical-align:middle; width:192px" %)**U0-21**|(% style="text-align:center; vertical-align:middle; width:364px" %)**Monitoring name**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Panel display**|(% style="text-align:center; vertical-align:middle" %)**Unit**|(% style="text-align:center; vertical-align:middle" %)**Data type**
1987 |(% style="text-align:center; vertical-align:middle; width:364px" %)AI1 input voltage value|(% rowspan="2" style="text-align:center; vertical-align:middle" %)-|(% rowspan="2" style="text-align:center; vertical-align:middle" %)Universal|(% rowspan="2" style="text-align:center; vertical-align:middle" %)Decimal|(% rowspan="2" style="text-align:center; vertical-align:middle" %)V|(% rowspan="2" style="text-align:center; vertical-align:middle" %)16-bit
1988 |(% style="text-align:center; vertical-align:middle; width:364px" %)Reserved**☆**
1989 |(% colspan="7" %)(((
1990 Display the actual sampling voltage of analog channel 1.
1991
1992 (% class="table-bordered" %)
1993 |(% style="text-align:center; vertical-align:middle" %)10.00V display|(% style="text-align:center; vertical-align:middle" %)-10.00V display
1994 |(% style="text-align:center; vertical-align:middle" %)[[image:http://docs.we-con.com.cn/wiki/servo/download/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/WebHome/Wecon%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29_html_855140805a238a06.gif?rev=1.1||alt="Wecon VD2 SA Series Servo Drives Manual (Full V1.1)_html_855140805a238a06.gif"]]|(% style="text-align:center; vertical-align:middle" %)[[image:http://docs.we-con.com.cn/wiki/servo/download/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/WebHome/Wecon%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29_html_222555baaf8cf124.gif?rev=1.1||alt="Wecon VD2 SA Series Servo Drives Manual (Full V1.1)_html_222555baaf8cf124.gif"]]
1995
1996 “☆” indicates that the VD2F servo drive does not have this monitoring.
1997 )))
1998
1999 (% class="table-bordered" %)
2000 |(% rowspan="3" style="text-align:center; vertical-align:middle; width:194px" %)**U0-22**|(% style="text-align:center; vertical-align:middle; width:362px" %)**Monitoring name**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Panel display**|(% style="text-align:center; vertical-align:middle" %)**Unit**|(% style="text-align:center; vertical-align:middle" %)**Data type**
2001 |(% style="text-align:center; vertical-align:middle; width:362px" %)AI2 input voltage value|(% rowspan="2" style="text-align:center; vertical-align:middle" %)-|(% rowspan="2" style="text-align:center; vertical-align:middle" %)Universal|(% rowspan="2" style="text-align:center; vertical-align:middle" %)Decimal|(% rowspan="2" style="text-align:center; vertical-align:middle" %)V|(% rowspan="2" style="text-align:center; vertical-align:middle" %)16-bit
2002 |(% style="text-align:center; vertical-align:middle; width:362px" %)Reserved**☆**
2003 |(% colspan="7" %)“☆” indicates that the VD2F servo drive does not have this monitoring.
2004
2005 (% class="table-bordered" %)
2006 |(% rowspan="2" style="text-align:center; vertical-align:middle; width:191px" %)**U0-23**|(% style="text-align:center; vertical-align:middle; width:339px" %)**Monitoring name**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Panel display**|(% style="text-align:center; vertical-align:middle" %)**Unit**|(% style="text-align:center; vertical-align:middle" %)**Data type**
2007 |(% style="text-align:center; vertical-align:middle; width:339px" %)Vibration Frequency|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)Universal|(% style="text-align:center; vertical-align:middle" %)Decimal|(% style="text-align:center; vertical-align:middle" %)Hz|(% style="text-align:center; vertical-align:middle" %)16-bit
2008
2009 (% class="table-bordered" %)
2010 |(% rowspan="2" style="text-align:center; vertical-align:middle; width:189px" %)**U0-24**|(% style="text-align:center; vertical-align:middle; width:338px" %)**Monitoring name**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Panel display**|(% style="text-align:center; vertical-align:middle" %)**Unit**|(% style="text-align:center; vertical-align:middle" %)**Data type**
2011 |(% style="text-align:center; vertical-align:middle; width:338px" %)Vibration amplitude|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)Universal|(% style="text-align:center; vertical-align:middle" %)Decimal|(% style="text-align:center; vertical-align:middle" %)rpm|(% style="text-align:center; vertical-align:middle" %)16-bit
2012
2013 (% class="table-bordered" %)
2014 |(% rowspan="2" style="text-align:center; vertical-align:middle; width:192px" %)**U0-25**|(% style="text-align:center; vertical-align:middle; width:335px" %)**Monitoring name**|(% style="text-align:center; vertical-align:middle; width:154px" %)**Range**|(% style="text-align:center; vertical-align:middle; width:200px" %)**Category**|(% style="text-align:center; vertical-align:middle; width:271px" %)**Panel display**|(% style="text-align:center; vertical-align:middle; width:122px" %)**Unit**|(% style="text-align:center; vertical-align:middle; width:211px" %)**Data type**
2015 |(% style="text-align:center; vertical-align:middle; width:335px" %)Forward torque limit value|(% style="text-align:center; vertical-align:middle; width:154px" %)0 to 300|(% style="text-align:center; vertical-align:middle; width:200px" %)Universal|(% style="text-align:center; vertical-align:middle; width:271px" %)Decimal|(% style="text-align:center; vertical-align:middle; width:122px" %)%|(% style="text-align:center; vertical-align:middle; width:211px" %)16-bit
2016 |(% colspan="7" style="text-align:center; vertical-align:middle" %)(((
2017 Display the set value of P01-15 (forward torque limit) of servo drive. If U0-25 is 288%, the panel of servo drive is displayed as below.
2018
2019 [[image:http://docs.we-con.com.cn/wiki/servo/download/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/WebHome/Wecon%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29_html_941a1c305d659697.gif?rev=1.1||alt="Wecon VD2 SA Series Servo Drives Manual (Full V1.1)_html_941a1c305d659697.gif"]]
2020 )))
2021
2022 (% class="table-bordered" %)
2023 |(% rowspan="2" style="text-align:center; vertical-align:middle; width:190px" %)**U0-26**|(% style="text-align:center; vertical-align:middle; width:388px" %)**Monitoring name**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Panel display**|(% style="text-align:center; vertical-align:middle" %)**Unit**|(% style="text-align:center; vertical-align:middle" %)**Data type**
2024 |(% style="text-align:center; vertical-align:middle; width:388px" %)Reverse torque limit value|(% style="text-align:center; vertical-align:middle" %)0 to 300|(% style="text-align:center; vertical-align:middle" %)Universal|(% style="text-align:center; vertical-align:middle" %)Decimal|(% style="text-align:center; vertical-align:middle" %)%|(% style="text-align:center; vertical-align:middle" %)16-bit
2025 |(% colspan="7" style="text-align:center; vertical-align:middle" %)(((
2026 Display the set value of P01-16 (reverse torque limit) of servo drive. If U0-26 is 300%, the panel of servo drive is displayed as below.
2027
2028 [[image:http://docs.we-con.com.cn/wiki/servo/download/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/WebHome/Wecon%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29_html_a3c4812a51c03203.gif?rev=1.1||alt="Wecon VD2 SA Series Servo Drives Manual (Full V1.1)_html_a3c4812a51c03203.gif"]]
2029 )))
2030
2031 (% class="table-bordered" %)
2032 |(% rowspan="2" style="text-align:center; vertical-align:middle; width:193px" %)**U0-27**|(% style="text-align:center; vertical-align:middle; width:376px" %)**Monitoring name**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Panel display**|(% style="text-align:center; vertical-align:middle" %)**Unit**|(% style="text-align:center; vertical-align:middle" %)**Data type**
2033 |(% style="text-align:center; vertical-align:middle; width:376px" %)Forward speed limit value|(% style="text-align:center; vertical-align:middle" %)0 to 5000|(% style="text-align:center; vertical-align:middle" %)Universal|(% style="text-align:center; vertical-align:middle" %)Decimal|(% style="text-align:center; vertical-align:middle" %)rpm|(% style="text-align:center; vertical-align:middle" %)16-bit
2034 |(% colspan="7" style="text-align:center; vertical-align:middle" %)(((
2035 Display the set value of P01-12 (forward speed threshold) of servo drive. If P01-12 is set to 2000, the panel of servo drive is displayed as below.
2036
2037 [[image:http://docs.we-con.com.cn/wiki/servo/download/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/WebHome/Wecon%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29_html_fa4ee08874f253c8.gif?rev=1.1||alt="Wecon VD2 SA Series Servo Drives Manual (Full V1.1)_html_fa4ee08874f253c8.gif"]]
2038 )))
2039
2040 |(% rowspan="2" style="text-align:center; vertical-align:middle; width:188px" %)**U0-28**|(% style="text-align:center; vertical-align:middle; width:383px" %)**Monitoring name**|(% style="text-align:center; vertical-align:middle; width:184px" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle; width:230px" %)**Panel display**|(% style="text-align:center; vertical-align:middle; width:124px" %)**Unit**|(% style="text-align:center; vertical-align:middle" %)**Data type**
2041 |(% style="text-align:center; vertical-align:middle; width:383px" %)Reverse speed limit value|(% style="text-align:center; vertical-align:middle; width:184px" %)-5000 to 0|(% style="text-align:center; vertical-align:middle" %)Universal|(% style="text-align:center; vertical-align:middle; width:230px" %)Decimal|(% style="text-align:center; vertical-align:middle; width:124px" %)rpm|(% style="text-align:center; vertical-align:middle" %)16-bit
2042 |(% colspan="7" style="text-align:center; vertical-align:middle" %)(((
2043 Display the set value of P01-13 (reverse speed threshold) of servo drive. If P01-13 is set to 3000, the panel of servo drive is displayed as below.
2044
2045 [[image:http://docs.we-con.com.cn/wiki/servo/download/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/WebHome/Wecon%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29_html_eb1e0ee021f5cc6c.gif?rev=1.1||alt="Wecon VD2 SA Series Servo Drives Manual (Full V1.1)_html_eb1e0ee021f5cc6c.gif"]]
2046 )))
2047
2048 (% class="table-bordered" %)
2049 |(% rowspan="2" style="text-align:center; vertical-align:middle; width:188px" %)**U0-29**|(% style="text-align:center; vertical-align:middle; width:382px" %)**Monitoring name**|(% style="text-align:center; vertical-align:middle; width:183px" %)**Range**|(% style="text-align:center; vertical-align:middle; width:188px" %)**Category**|(% style="text-align:center; vertical-align:middle; width:214px" %)**Panel display**|(% style="text-align:center; vertical-align:middle; width:114px" %)**Unit**|(% style="text-align:center; vertical-align:middle" %)**Data type**
2050 |(% style="text-align:center; vertical-align:middle; width:382px" %)Mechanical angle|(% style="text-align:center; vertical-align:middle; width:183px" %)0 to 359|(% style="text-align:center; vertical-align:middle; width:188px" %)Universal|(% style="text-align:center; vertical-align:middle; width:214px" %)Decimal|(% style="text-align:center; vertical-align:middle; width:114px" %)°|(% style="text-align:center; vertical-align:middle" %)16-bit
2051 |(% colspan="7" style="text-align:center; vertical-align:middle" %)(((
2052 Display current mechanical angle of motor. 0 corresponds to a mechanical angle of 0 degree.
2053
2054 If the mechanical angle is 270°, the panel of servo drive is displayed as below.
2055
2056 [[image:http://docs.we-con.com.cn/wiki/servo/download/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/WebHome/Wecon%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29_html_7c9e640893ca731e.gif?rev=1.1||alt="Wecon VD2 SA Series Servo Drives Manual (Full V1.1)_html_7c9e640893ca731e.gif"]]
2057 )))
2058
2059 (% class="table-bordered" %)
2060 |(% rowspan="2" style="text-align:center; vertical-align:middle; width:189px" %)**U0-30**|(% style="text-align:center; vertical-align:middle; width:383px" %)**Monitoring name**|(% style="text-align:center; vertical-align:middle; width:175px" %)**Range**|(% style="text-align:center; vertical-align:middle; width:194px" %)**Category**|(% style="text-align:center; vertical-align:middle; width:208px" %)**Panel display**|(% style="text-align:center; vertical-align:middle" %)**Unit**|(% style="text-align:center; vertical-align:middle" %)**Data type**
2061 |(% style="text-align:center; vertical-align:middle; width:383px" %)Electrical angle|(% style="text-align:center; vertical-align:middle; width:175px" %)0 to 359|(% style="text-align:center; vertical-align:middle; width:194px" %)Universal|(% style="text-align:center; vertical-align:middle; width:208px" %)Decimal|(% style="text-align:center; vertical-align:middle" %)°|(% style="text-align:center; vertical-align:middle" %)16-bit
2062 |(% colspan="7" style="text-align:center; vertical-align:middle" %)(((
2063 Display current electrical angle of motor. The accuracy is 1°. When the motor rotates, the angle range is 360°. When the motor is 4 poles, every time the motor is rotated one turn, it undergoes a change process of 0° to 359° four times.
2064
2065 [[image:http://docs.we-con.com.cn/wiki/servo/download/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/WebHome/Wecon%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29_html_5b4f740abbf0a7d9.gif?rev=1.1||alt="Wecon VD2 SA Series Servo Drives Manual (Full V1.1)_html_5b4f740abbf0a7d9.gif"]]
2066 )))
2067
2068 (% class="table-bordered" %)
2069 |(% rowspan="2" style="text-align:center; vertical-align:middle; width:189px" %)**U0-31**|(% style="text-align:center; vertical-align:middle; width:387px" %)**Monitoring name**|(% style="text-align:center; vertical-align:middle; width:177px" %)**Range**|(% style="text-align:center; vertical-align:middle; width:199px" %)**Category**|(% style="text-align:center; vertical-align:middle; width:192px" %)**Panel display**|(% style="text-align:center; vertical-align:middle" %)**Unit**|(% style="text-align:center; vertical-align:middle" %)**Data type**
2070 |(% style="text-align:center; vertical-align:middle; width:387px" %)Bus voltage|(% style="text-align:center; vertical-align:middle; width:177px" %)-|(% style="text-align:center; vertical-align:middle; width:199px" %)Universal|(% style="text-align:center; vertical-align:middle; width:192px" %)Decimal|(% style="text-align:center; vertical-align:middle" %)V|(% style="text-align:center; vertical-align:middle" %)16-bit
2071 |(% colspan="7" style="text-align:center; vertical-align:middle" %)(((
2072 Display the DC bus voltage of the main circuit input voltage of servo drive after rectification. If the bus voltage is 310.9, the panel of servo drive is displayed as below.
2073
2074 [[image:http://docs.we-con.com.cn/wiki/servo/download/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/WebHome/Wecon%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29_html_968bf6918f15fbac.gif?rev=1.1||alt="Wecon VD2 SA Series Servo Drives Manual (Full V1.1)_html_968bf6918f15fbac.gif"]]
2075 )))
2076
2077 (% class="table-bordered" %)
2078 |(% rowspan="2" style="text-align:center; vertical-align:middle; width:183px" %)**U0-32**|(% style="text-align:center; vertical-align:middle; width:372px" %)**Monitoring name**|(% style="text-align:center; vertical-align:middle; width:139px" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Panel display**|(% style="text-align:center; vertical-align:middle" %)**Unit**|(% style="text-align:center; vertical-align:middle" %)**Data type**
2079 |(% style="text-align:center; vertical-align:middle; width:372px" %)Radiator temperature|(% style="text-align:center; vertical-align:middle; width:139px" %)-|(% style="text-align:center; vertical-align:middle" %)Universal|(% style="text-align:center; vertical-align:middle" %)Decimal|(% style="text-align:center; vertical-align:middle" %)°C|(% style="text-align:center; vertical-align:middle" %)16-bit
2080
2081 (% class="table-bordered" %)
2082 |(% rowspan="2" style="text-align:center; vertical-align:middle; width:184px" %)**U0-33**|(% style="text-align:center; vertical-align:middle; width:370px" %)**Monitoring name**|(% style="text-align:center; vertical-align:middle; width:141px" %)**Range**|(% style="text-align:center; vertical-align:middle; width:199px" %)**Category**|(% style="text-align:center; vertical-align:middle; width:266px" %)**Panel display**|(% style="text-align:center; vertical-align:middle; width:116px" %)**Unit**|(% style="text-align:center; vertical-align:middle; width:209px" %)**Data type**
2083 |(% style="text-align:center; vertical-align:middle; width:370px" %)Instantaneous output power|(% style="text-align:center; vertical-align:middle; width:141px" %)-|(% style="text-align:center; vertical-align:middle; width:199px" %)Universal|(% style="text-align:center; vertical-align:middle; width:266px" %)Decimal|(% style="text-align:center; vertical-align:middle; width:116px" %)W|(% style="text-align:center; vertical-align:middle; width:209px" %)16-bit
2084
2085 (% class="table-bordered" %)
2086 |(% rowspan="2" style="text-align:center; vertical-align:middle; width:186px" %)**U0-34**|(% style="text-align:center; vertical-align:middle; width:367px" %)**Monitoring name**|(% style="text-align:center; vertical-align:middle; width:144px" %)**Range**|(% style="text-align:center; vertical-align:middle; width:198px" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Panel display**|(% style="text-align:center; vertical-align:middle" %)**Unit**|(% style="text-align:center; vertical-align:middle" %)**Data type**
2087 |(% style="text-align:center; vertical-align:middle; width:367px" %)Average output power|(% style="text-align:center; vertical-align:middle; width:144px" %)-|(% style="text-align:center; vertical-align:middle; width:198px" %)Universal|(% style="text-align:center; vertical-align:middle" %)Decimal|(% style="text-align:center; vertical-align:middle" %)W|(% style="text-align:center; vertical-align:middle" %)16-bit
2088
2089 (% class="table-bordered" %)
2090 |(% rowspan="2" style="text-align:center; vertical-align:middle; width:186px" %)**U0-35**|(% style="text-align:center; vertical-align:middle; width:367px" %)**Monitoring name**|(% style="text-align:center; vertical-align:middle; width:146px" %)**Range**|(% style="text-align:center; vertical-align:middle; width:197px" %)**Category**|(% style="text-align:center; vertical-align:middle; width:266px" %)**Panel display**|(% style="text-align:center; vertical-align:middle; width:113px" %)**Unit**|(% style="text-align:center; vertical-align:middle; width:210px" %)**Data type**
2091 |(% style="text-align:center; vertical-align:middle; width:367px" %)Total operation time (hour)|(% style="text-align:center; vertical-align:middle; width:146px" %)-|(% style="text-align:center; vertical-align:middle; width:197px" %)Universal|(% style="text-align:center; vertical-align:middle; width:266px" %)Decimal|(% style="text-align:center; vertical-align:middle; width:113px" %)h|(% style="text-align:center; vertical-align:middle; width:210px" %)16-bit
2092
2093 (% class="table-bordered" %)
2094 |(% rowspan="2" style="text-align:center; vertical-align:middle; width:186px" %)**U0-37**|(% style="text-align:center; vertical-align:middle; width:368px" %)**Monitoring name**|(% style="text-align:center; vertical-align:middle; width:145px" %)**Range**|(% style="text-align:center; vertical-align:middle; width:198px" %)**Category**|(% style="text-align:center; vertical-align:middle; width:267px" %)**Panel display**|(% style="text-align:center; vertical-align:middle; width:111px" %)**Unit**|(% style="text-align:center; vertical-align:middle; width:210px" %)**Data type**
2095 |(% style="text-align:center; vertical-align:middle; width:368px" %)Total operation time (minutes)|(% style="text-align:center; vertical-align:middle; width:145px" %)-|(% style="text-align:center; vertical-align:middle; width:198px" %)Universal|(% style="text-align:center; vertical-align:middle; width:267px" %)Decimal|(% style="text-align:center; vertical-align:middle; width:111px" %)min|(% style="text-align:center; vertical-align:middle; width:210px" %)16-bit
2096
2097 (% class="table-bordered" %)
2098 |(% rowspan="2" style="text-align:center; vertical-align:middle; width:188px" %)**U0-38**|(% style="text-align:center; vertical-align:middle; width:366px" %)**Monitoring name**|(% style="text-align:center; vertical-align:middle; width:146px" %)**Range**|(% style="text-align:center; vertical-align:middle; width:197px" %)**Category**|(% style="text-align:center; vertical-align:middle; width:265px" %)**Panel display**|(% style="text-align:center; vertical-align:middle; width:117px" %)**Unit**|(% style="text-align:center; vertical-align:middle; width:206px" %)**Data type**
2099 |(% style="text-align:center; vertical-align:middle; width:366px" %)Total operation time (seconds)|(% style="text-align:center; vertical-align:middle; width:146px" %)-|(% style="text-align:center; vertical-align:middle; width:197px" %)Universal|(% style="text-align:center; vertical-align:middle; width:265px" %)Decimal|(% style="text-align:center; vertical-align:middle; width:117px" %)s|(% style="text-align:center; vertical-align:middle; width:206px" %)16-bit
2100
2101 (% class="table-bordered" %)
2102 |(% rowspan="2" style="text-align:center; vertical-align:middle; width:145px" %)**U0-39**|(% style="text-align:center; vertical-align:middle; width:410px" %)**Monitoring name**|(% style="text-align:center; vertical-align:middle; width:145px" %)**Range**|(% style="text-align:center; vertical-align:middle; width:199px" %)**Category**|(% style="text-align:center; vertical-align:middle; width:264px" %)**Panel display**|(% style="text-align:center; vertical-align:middle; width:107px" %)**Unit**|(% style="text-align:center; vertical-align:middle; width:215px" %)**Data type**
2103 |(% style="text-align:center; vertical-align:middle; width:410px" %)Load torque percentage|(% style="text-align:center; vertical-align:middle; width:145px" %)-|(% style="text-align:center; vertical-align:middle; width:199px" %)Universal|(% style="text-align:center; vertical-align:middle; width:264px" %)Decimal|(% style="text-align:center; vertical-align:middle; width:107px" %)%|(% style="text-align:center; vertical-align:middle; width:215px" %)16-bit
2104 |(% colspan="7" style="text-align:center; vertical-align:middle" %)(((
2105 Display current load torque percentage. If the current load torque percentage is 10.3%, the panel of servo drive is displayed as below.
2106
2107 [[image:http://docs.we-con.com.cn/wiki/servo/download/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/WebHome/Wecon%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29_html_26d3d1dc981bc243.gif?rev=1.1||alt="Wecon VD2 SA Series Servo Drives Manual (Full V1.1)_html_26d3d1dc981bc243.gif"]]
2108 )))
2109
2110 |(% rowspan="2" style="text-align:center; vertical-align:middle; width:195px" %)**U0-40**|(% style="text-align:center; vertical-align:middle; width:360px" %)**Monitoring name**|(% style="text-align:center; vertical-align:middle; width:153px" %)**Range**|(% style="text-align:center; vertical-align:middle; width:197px" %)**Category**|(% style="text-align:center; vertical-align:middle; width:263px" %)**Panel display**|(% style="text-align:center; vertical-align:middle; width:111px" %)**Unit**|(% style="text-align:center; vertical-align:middle; width:206px" %)**Data type**
2111 |(% style="text-align:center; vertical-align:middle; width:360px" %)Current operation time (hour)|(% style="text-align:center; vertical-align:middle; width:153px" %)-|(% style="text-align:center; vertical-align:middle; width:197px" %)Universal|(% style="text-align:center; vertical-align:middle; width:263px" %)Decimal|(% style="text-align:center; vertical-align:middle; width:111px" %)h|(% style="text-align:center; vertical-align:middle; width:206px" %)16-bit
2112
2113 |(% rowspan="2" style="text-align:center; vertical-align:middle; width:196px" %)**U0-42**|(% style="text-align:center; vertical-align:middle; width:363px" %)**Monitoring name**|(% style="text-align:center; vertical-align:middle; width:151px" %)**Range**|(% style="text-align:center; vertical-align:middle; width:197px" %)**Category**|(% style="text-align:center; vertical-align:middle; width:264px" %)**Panel display**|(% style="text-align:center; vertical-align:middle; width:110px" %)**Unit**|(% style="text-align:center; vertical-align:middle; width:204px" %)**Data type**
2114 |(% style="text-align:center; vertical-align:middle; width:363px" %)Current operation time (minutes)|(% style="text-align:center; vertical-align:middle; width:151px" %)-|(% style="text-align:center; vertical-align:middle; width:197px" %)Universal|(% style="text-align:center; vertical-align:middle; width:264px" %)Decimal|(% style="text-align:center; vertical-align:middle; width:110px" %)min|(% style="text-align:center; vertical-align:middle; width:204px" %)16-bit
2115
2116 |(% rowspan="2" style="text-align:center; vertical-align:middle; width:197px" %)**U0-43**|(% style="text-align:center; vertical-align:middle; width:362px" %)**Monitoring name**|(% style="text-align:center; vertical-align:middle; width:152px" %)**Range**|(% style="text-align:center; vertical-align:middle; width:199px" %)**Category**|(% style="text-align:center; vertical-align:middle; width:264px" %)**Panel display**|(% style="text-align:center; vertical-align:middle; width:111px" %)**Unit**|(% style="text-align:center; vertical-align:middle; width:200px" %)**Data type**
2117 |(% style="text-align:center; vertical-align:middle; width:362px" %)Current operation time (seconds)|(% style="text-align:center; vertical-align:middle; width:152px" %)-|(% style="text-align:center; vertical-align:middle; width:199px" %)Universal|(% style="text-align:center; vertical-align:middle; width:264px" %)Decimal|(% style="text-align:center; vertical-align:middle; width:111px" %)s|(% style="text-align:center; vertical-align:middle; width:200px" %)16-bit
2118
2119 |(% rowspan="2" style="text-align:center; vertical-align:middle; width:197px" %)**U0-44**|(% style="text-align:center; vertical-align:middle; width:365px" %)**Monitoring name**|(% style="text-align:center; vertical-align:middle; width:150px" %)**Range**|(% style="text-align:center; vertical-align:middle; width:200px" %)**Category**|(% style="text-align:center; vertical-align:middle; width:265px" %)**Panel display**|(% style="text-align:center; vertical-align:middle; width:111px" %)**Unit**|(% style="text-align:center; vertical-align:middle; width:197px" %)**Data type**
2120 |(% style="text-align:center; vertical-align:middle; width:365px" %)Instantaneous braking resistor power|(% style="text-align:center; vertical-align:middle; width:150px" %)-|(% style="text-align:center; vertical-align:middle; width:200px" %)Universal|(% style="text-align:center; vertical-align:middle; width:265px" %)Decimal|(% style="text-align:center; vertical-align:middle; width:111px" %)W|(% style="text-align:center; vertical-align:middle; width:197px" %)16-bit
2121
2122 |(% rowspan="2" style="text-align:center; vertical-align:middle; width:201px" %)**U0-46**|(% style="text-align:center; vertical-align:middle; width:361px" %)**Monitoring name**|(% style="text-align:center; vertical-align:middle; width:151px" %)**Range**|(% style="text-align:center; vertical-align:middle; width:203px" %)**Category**|(% style="text-align:center; vertical-align:middle; width:260px" %)**Panel display**|(% style="text-align:center; vertical-align:middle; width:110px" %)**Unit**|(% style="text-align:center; vertical-align:middle; width:199px" %)**Data type**
2123 |(% style="text-align:center; vertical-align:middle; width:361px" %)Average braking resistor power|(% style="text-align:center; vertical-align:middle; width:151px" %)-|(% style="text-align:center; vertical-align:middle; width:203px" %)Universal|(% style="text-align:center; vertical-align:middle; width:260px" %)Decimal|(% style="text-align:center; vertical-align:middle; width:110px" %)W|(% style="text-align:center; vertical-align:middle; width:199px" %)16-bit
2124
2125 |(% rowspan="2" style="text-align:center; vertical-align:middle; width:201px" %)**U0-48**|(% style="text-align:center; vertical-align:middle; width:360px" %)**Monitoring name**|(% style="text-align:center; vertical-align:middle; width:151px" %)**Range**|(% style="text-align:center; vertical-align:middle; width:206px" %)**Category**|(% style="text-align:center; vertical-align:middle; width:262px" %)**Panel display**|(% style="text-align:center; vertical-align:middle; width:111px" %)**Unit**|(% style="text-align:center; vertical-align:middle; width:194px" %)**Data type**
2126 |(% style="text-align:center; vertical-align:middle; width:360px" %)Power-on times|(% style="text-align:center; vertical-align:middle; width:151px" %)-|(% style="text-align:center; vertical-align:middle; width:206px" %)Universal|(% style="text-align:center; vertical-align:middle; width:262px" %)Decimal|(% style="text-align:center; vertical-align:middle; width:111px" %)Times|(% style="text-align:center; vertical-align:middle; width:194px" %)16-bit
2127
2128 |(% rowspan="2" style="text-align:center; vertical-align:middle; width:200px" %)**U0-50**|(% style="text-align:center; vertical-align:middle; width:360px" %)**Monitoring name**|(% style="text-align:center; vertical-align:middle; width:153px" %)**Range**|(% style="text-align:center; vertical-align:middle; width:206px" %)**Category**|(% style="text-align:center; vertical-align:middle; width:260px" %)**Panel display**|(% style="text-align:center; vertical-align:middle; width:113px" %)**Unit**|(% style="text-align:center; vertical-align:middle; width:193px" %)**Data type**
2129 |(% style="text-align:center; vertical-align:middle; width:360px" %)Motor cumulative number of turns (low 32 bits)|(% style="text-align:center; vertical-align:middle; width:153px" %)0 to 2^^32^^-1|(% style="text-align:center; vertical-align:middle; width:206px" %)Universal|(% style="text-align:center; vertical-align:middle; width:260px" %)Decimal|(% style="text-align:center; vertical-align:middle; width:113px" %)Cycles|(% style="text-align:center; vertical-align:middle; width:193px" %)32-bit
2130
2131 |(% rowspan="2" style="text-align:center; vertical-align:middle; width:200px" %)**U0-51**|(% style="text-align:center; vertical-align:middle; width:360px" %)**Monitoring name**|(% style="text-align:center; vertical-align:middle; width:154px" %)**Range**|(% style="text-align:center; vertical-align:middle; width:209px" %)**Category**|(% style="text-align:center; vertical-align:middle; width:258px" %)**Panel display**|(% style="text-align:center; vertical-align:middle; width:116px" %)**Unit**|(% style="text-align:center; vertical-align:middle; width:188px" %)**Data type**
2132 |(% style="text-align:center; vertical-align:middle; width:360px" %)Motor cumulative number of turns (high 32 bits)|(% style="text-align:center; vertical-align:middle; width:154px" %)0 to 2^^32^^-1|(% style="text-align:center; vertical-align:middle; width:209px" %)Universal|(% style="text-align:center; vertical-align:middle; width:258px" %)Decimal|(% style="text-align:center; vertical-align:middle; width:116px" %)Cycles|(% style="text-align:center; vertical-align:middle; width:188px" %)32-bit
2133
2134 |(% rowspan="2" style="text-align:center; vertical-align:middle; width:201px" %)**U0-53**|(% style="text-align:center; vertical-align:middle; width:361px" %)**Monitoring name**|(% style="text-align:center; vertical-align:middle; width:152px" %)**Range**|(% style="text-align:center; vertical-align:middle; width:208px" %)**Category**|(% style="text-align:center; vertical-align:middle; width:262px" %)**Panel display**|(% style="text-align:center; vertical-align:middle; width:117px" %)**Unit**|(% style="text-align:center; vertical-align:middle; width:184px" %)**Data type**
2135 |(% style="text-align:center; vertical-align:middle; width:361px" %)Motor model code|(% style="text-align:center; vertical-align:middle; width:152px" %)-|(% style="text-align:center; vertical-align:middle; width:208px" %)Universal|(% style="text-align:center; vertical-align:middle; width:262px" %)Hexadecimal|(% style="text-align:center; vertical-align:middle; width:117px" %)-|(% style="text-align:center; vertical-align:middle; width:184px" %)16-bit
2136 |(% colspan="7" %)(((
2137 Display current Motor model code. Take WD80M-07530S-A1F (A026) as an example, the panel of servo drive is displayed as below.
2138
2139 (% style="text-align:center" %)
2140 [[image:http://docs.we-con.com.cn/wiki/servo/download/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/WebHome/Wecon%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29_html_56418adb13fd0c69.gif?rev=1.1||alt="Wecon VD2 SA Series Servo Drives Manual (Full V1.1)_html_56418adb13fd0c69.gif"]]
2141 )))
2142
2143 |(% rowspan="2" style="text-align:center; vertical-align:middle; width:198px" %)**U0-54**|(% style="text-align:center; vertical-align:middle; width:364px" %)**Monitoring name**|(% style="text-align:center; vertical-align:middle; width:156px" %)**Range**|(% style="text-align:center; vertical-align:middle; width:221px" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Panel display**|(% style="text-align:center; vertical-align:middle" %)**Unit**|(% style="text-align:center; vertical-align:middle" %)**Data type**
2144 |(% style="text-align:center; vertical-align:middle; width:364px" %)Absolute encoder position within 1 circle|(% style="text-align:center; vertical-align:middle; width:156px" %)0 to 2^^32^^-1|(% style="text-align:center; vertical-align:middle; width:221px" %)Universal|(% style="text-align:center; vertical-align:middle" %)Decimal|(% style="text-align:center; vertical-align:middle" %)Encoder unit|(% style="text-align:center; vertical-align:middle" %)32-bit
2145 |(% colspan="7" %)Display the single turn position feedback value of absolute encoder
2146
2147 |(% rowspan="2" style="text-align:center; vertical-align:middle; width:201px" %)**U0-55**|(% style="text-align:center; vertical-align:middle; width:367px" %)**Monitoring name**|(% style="text-align:center; vertical-align:middle; width:157px" %)**Range**|(% style="text-align:center; vertical-align:middle; width:217px" %)**Category**|(% style="text-align:center; vertical-align:middle; width:185px" %)**Panel display**|(% style="text-align:center; vertical-align:middle" %)**Unit**|(% style="text-align:center; vertical-align:middle" %)**Data type**
2148 |(% style="text-align:center; vertical-align:middle; width:367px" %)Circle numbers of absolute encoder|(% style="text-align:center; vertical-align:middle; width:157px" %)0 to 65535|(% style="text-align:center; vertical-align:middle; width:217px" %)Universal|(% style="text-align:center; vertical-align:middle; width:185px" %)Decimal|(% style="text-align:center; vertical-align:middle" %)Encoder unit|(% style="text-align:center; vertical-align:middle" %)16-bit
2149 |(% colspan="7" %)Display the circle number of multi-turn absolute encoder
2150
2151 |(% rowspan="2" style="text-align:center; vertical-align:middle; width:199px" %)**U0-56**|(% style="text-align:center; vertical-align:middle; width:373px" %)**Monitoring name**|(% style="text-align:center; vertical-align:middle; width:168px" %)**Range**|(% style="text-align:center; vertical-align:middle; width:201px" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Panel display**|(% style="text-align:center; vertical-align:middle" %)**Unit**|(% style="text-align:center; vertical-align:middle" %)**Data type**
2152 |(% style="text-align:center; vertical-align:middle; width:373px" %)Multi-turn absolute encoder current position|(% style="text-align:center; vertical-align:middle; width:168px" %)-2^^31^^ to 2^^31^^|(% style="text-align:center; vertical-align:middle; width:201px" %)Universal|(% style="text-align:center; vertical-align:middle" %)Decimal|(% style="text-align:center; vertical-align:middle" %)Instruction unit|(% style="text-align:center; vertical-align:middle" %)32-bit
2153 |(% colspan="7" %)Display the absolute position of motor (instruction unit). It is only valid is multi-turn absolute encoder motor
2154
2155 = **Group U1 Warning monitoring** =
2156
2157 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**U1-01**|(% style="text-align:center; vertical-align:middle" %)**Monitoring name**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Panel display**|(% style="text-align:center; vertical-align:middle" %)**Unit**|(% style="text-align:center; vertical-align:middle" %)**Data type**
2158 |(% style="text-align:center; vertical-align:middle" %)Current fault code|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)Warning|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)16-bit
2159 |(% colspan="7" %)(((
2160 If there is fault in servo drive, it would display the corresponding fault. If not, the panel displays “~-~--”.
2161
2162 Take the fault “encoder disconnect” as an example, the panel of servo drive is displayed as below.
2163
2164 |(% style="text-align:center; vertical-align:middle" %)Servo drive has an fault “encoder disconnection”|(% style="text-align:center; vertical-align:middle" %)Servo drive has no fault
2165 |(% style="text-align:center; vertical-align:middle" %)[[image:http://docs.we-con.com.cn/wiki/servo/download/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/WebHome/Wecon%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29_html_d64b8e43582f33ef.gif?rev=1.1||alt="Wecon VD2 SA Series Servo Drives Manual (Full V1.1)_html_d64b8e43582f33ef.gif"]]|(% style="text-align:center; vertical-align:middle" %)[[image:http://docs.we-con.com.cn/wiki/servo/download/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/WebHome/Wecon%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29_html_bd4524b30a01d1ed.gif?rev=1.1||alt="Wecon VD2 SA Series Servo Drives Manual (Full V1.1)_html_bd4524b30a01d1ed.gif"]]
2166 )))
2167
2168 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**U1-02**|(% style="text-align:center; vertical-align:middle" %)**Monitoring name**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Panel display**|(% style="text-align:center; vertical-align:middle" %)**Unit**|(% style="text-align:center; vertical-align:middle" %)**Data type**
2169 |(% style="text-align:center; vertical-align:middle" %)Current warning code|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)Warning|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)16-bit
2170 |(% colspan="7" %)(((
2171 If there is warning in servo drive, it would display the corresponding warning. If not, the panel displays “~-~--”.
2172
2173 Take the warning“DI port configuration duplication” as an example, the panel is displayed as below.
2174
2175 |(% style="text-align:center; vertical-align:middle; width:897px" %)Servo drive has an warning “DI port configuration duplication”|(% style="text-align:center; vertical-align:middle; width:556px" %)Servo drive has no warning
2176 |(% style="text-align:center; vertical-align:middle; width:897px" %)[[image:http://docs.we-con.com.cn/wiki/servo/download/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/WebHome/Wecon%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29_html_90c7b633fe7be35d.gif?rev=1.1||alt="Wecon VD2 SA Series Servo Drives Manual (Full V1.1)_html_90c7b633fe7be35d.gif"]]|(% style="text-align:center; vertical-align:middle; width:556px" %)[[image:http://docs.we-con.com.cn/wiki/servo/download/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/WebHome/Wecon%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29_html_bd4524b30a01d1ed.gif?rev=1.1||alt="Wecon VD2 SA Series Servo Drives Manual (Full V1.1)_html_bd4524b30a01d1ed.gif"]]
2177 )))
2178
2179 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**U1-03**|(% style="text-align:center; vertical-align:middle" %)**Monitoring name**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Panel display**|(% style="text-align:center; vertical-align:middle" %)**Unit**|(% style="text-align:center; vertical-align:middle" %)**Data type**
2180 |(% style="text-align:center; vertical-align:middle" %)U phase current when faults occur|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)Warning|(% style="text-align:center; vertical-align:middle" %)Decimal|(% style="text-align:center; vertical-align:middle" %)A|(% style="text-align:center; vertical-align:middle" %)16-bit
2181
2182 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**U1-04**|(% style="text-align:center; vertical-align:middle" %)**Monitoring name**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Panel display**|(% style="text-align:center; vertical-align:middle" %)**Unit**|(% style="text-align:center; vertical-align:middle" %)**Data type**
2183 |(% style="text-align:center; vertical-align:middle" %)V phase current when faults occur|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)Warning|(% style="text-align:center; vertical-align:middle" %)Decimal|(% style="text-align:center; vertical-align:middle" %)A|(% style="text-align:center; vertical-align:middle" %)16-bit
2184
2185 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**U1-05**|(% style="text-align:center; vertical-align:middle" %)**Monitoring name**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Panel display**|(% style="text-align:center; vertical-align:middle" %)**Unit**|(% style="text-align:center; vertical-align:middle" %)**Data type**
2186 |(% style="text-align:center; vertical-align:middle" %)Bus voltage when faults occur|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)Warning|(% style="text-align:center; vertical-align:middle" %)Decimal|(% style="text-align:center; vertical-align:middle" %)V|(% style="text-align:center; vertical-align:middle" %)16-bit
2187
2188 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**U1-06**|(% style="text-align:center; vertical-align:middle" %)**Monitoring name**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Panel display**|(% style="text-align:center; vertical-align:middle" %)**Unit**|(% style="text-align:center; vertical-align:middle" %)**Data type**
2189 |(% style="text-align:center; vertical-align:middle" %)IGBT temperature when faults occur|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)Warning|(% style="text-align:center; vertical-align:middle" %)Decimal|(% style="text-align:center; vertical-align:middle" %)℃|(% style="text-align:center; vertical-align:middle" %)16-bit
2190
2191 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**U1-07**|(% style="text-align:center; vertical-align:middle" %)**Monitoring name**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Panel display**|(% style="text-align:center; vertical-align:middle" %)**Unit**|(% style="text-align:center; vertical-align:middle" %)**Data type**
2192 |(% style="text-align:center; vertical-align:middle" %)Torque component when faults occur|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)Warning|(% style="text-align:center; vertical-align:middle" %)Decimal|(% style="text-align:center; vertical-align:middle" %)%|(% style="text-align:center; vertical-align:middle" %)16-bit
2193
2194 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**U1-08**|(% style="text-align:center; vertical-align:middle" %)**Monitoring name**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Panel display**|(% style="text-align:center; vertical-align:middle" %)**Unit**|(% style="text-align:center; vertical-align:middle" %)**Data type**
2195 |(% style="text-align:center; vertical-align:middle" %)Excitation component when faults occur|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)Warning|(% style="text-align:center; vertical-align:middle" %)Decimal|(% style="text-align:center; vertical-align:middle" %)%|(% style="text-align:center; vertical-align:middle" %)16-bit
2196
2197 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**U1-09**|(% style="text-align:center; vertical-align:middle" %)**Monitoring name**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Panel display**|(% style="text-align:center; vertical-align:middle" %)**Unit**|(% style="text-align:center; vertical-align:middle" %)**Data type**
2198 |(% style="text-align:center; vertical-align:middle" %)Position deviation when faults occur|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)Warning|(% style="text-align:center; vertical-align:middle" %)Decimal|(% style="text-align:center; vertical-align:middle" %)Encoder unit|(% style="text-align:center; vertical-align:middle" %)32-bit
2199
2200 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**U1-10**|(% style="text-align:center; vertical-align:middle" %)**Monitoring name**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Panel display**|(% style="text-align:center; vertical-align:middle" %)**Unit**|(% style="text-align:center; vertical-align:middle" %)**Data type**
2201 |(% style="text-align:center; vertical-align:middle" %)The speed when faults occur|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)Warning|(% style="text-align:center; vertical-align:middle" %)Decimal|(% style="text-align:center; vertical-align:middle" %)rpm|(% style="text-align:center; vertical-align:middle" %)16-bit
2202
2203 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**U1-11**|(% style="text-align:center; vertical-align:middle" %)**Monitoring name**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Panel display**|(% style="text-align:center; vertical-align:middle" %)**Unit**|(% style="text-align:center; vertical-align:middle" %)**Data type**
2204 |(% style="text-align:center; vertical-align:middle" %)The time when faults occur|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)Warning|(% style="text-align:center; vertical-align:middle" %)Decimal|(% style="text-align:center; vertical-align:middle" %)s|(% style="text-align:center; vertical-align:middle" %)16-bit
2205
2206 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**U1-12**|(% style="text-align:center; vertical-align:middle" %)**Monitoring name**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Panel display**|(% style="text-align:center; vertical-align:middle" %)**Unit**|(% style="text-align:center; vertical-align:middle" %)**Data type**
2207 |(% style="text-align:center; vertical-align:middle" %)Number of faults in this operation|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)Warning|(% style="text-align:center; vertical-align:middle" %)Decimal|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)16-bit
2208
2209 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**U1-13**|(% style="text-align:center; vertical-align:middle" %)**Monitoring name**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Panel display**|(% style="text-align:center; vertical-align:middle" %)**Unit**|(% style="text-align:center; vertical-align:middle" %)**Data type**
2210 |(% style="text-align:center; vertical-align:middle" %)Number of warnings in this operation|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)Warning|(% style="text-align:center; vertical-align:middle" %)Decimal|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)16-bit
2211
2212 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**U1-14**|(% style="text-align:center; vertical-align:middle" %)**Monitoring name**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Panel display**|(% style="text-align:center; vertical-align:middle" %)**Unit**|(% style="text-align:center; vertical-align:middle" %)**Data type**
2213 |(% style="text-align:center; vertical-align:middle" %)Total number of historical faults|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)Warning|(% style="text-align:center; vertical-align:middle" %)Decimal|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)16-bit
2214
2215 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**U1-15**|(% style="text-align:center; vertical-align:middle" %)**Monitoring name**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Panel display**|(% style="text-align:center; vertical-align:middle" %)**Unit**|(% style="text-align:center; vertical-align:middle" %)**Data type**
2216 |(% style="text-align:center; vertical-align:middle" %)Total number of historical warnings|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)Warning|(% style="text-align:center; vertical-align:middle" %)Decimal|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)16-bit
2217
2218 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**U1-16**|(% style="text-align:center; vertical-align:middle" %)**Monitoring name**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Panel display**|(% style="text-align:center; vertical-align:middle" %)**Unit**|(% style="text-align:center; vertical-align:middle" %)**Data type**
2219 |(% style="text-align:center; vertical-align:middle" %)The 1st fault code of the most recent|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)Warning|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)16-bit
2220 |(% colspan="7" style="text-align:center; vertical-align:middle" %)Display the 1st fault code of the most recent of servo drive
2221
2222 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**U1-17**|(% style="text-align:center; vertical-align:middle" %)**Monitoring name**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Panel display**|(% style="text-align:center; vertical-align:middle" %)**Unit**|(% style="text-align:center; vertical-align:middle" %)**Data type**
2223 |(% style="text-align:center; vertical-align:middle" %)The 2nd fault code of the most recent|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)Warning|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)16-bit
2224
2225 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**U1-18**|(% style="text-align:center; vertical-align:middle" %)**Monitoring name**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Panel display**|(% style="text-align:center; vertical-align:middle" %)**Unit**|(% style="text-align:center; vertical-align:middle" %)**Data type**
2226 |(% style="text-align:center; vertical-align:middle" %)The 3rd fault code of the most recent|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)Warning|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)16-bit
2227
2228 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**U1-19**|(% style="text-align:center; vertical-align:middle" %)**Monitoring name**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Panel display**|(% style="text-align:center; vertical-align:middle" %)**Unit**|(% style="text-align:center; vertical-align:middle" %)**Data type**
2229 |(% style="text-align:center; vertical-align:middle" %)The 4th fault code of the most recent|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)Warning|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)16-bit
2230
2231 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**U1-20**|(% style="text-align:center; vertical-align:middle" %)**Monitoring name**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Panel display**|(% style="text-align:center; vertical-align:middle" %)**Unit**|(% style="text-align:center; vertical-align:middle" %)**Data type**
2232 |(% style="text-align:center; vertical-align:middle" %)The 5th fault code of the most recent|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)Warning|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)16-bit
2233
2234 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**U1-21**|(% style="text-align:center; vertical-align:middle; width:561px" %)**Monitoring name**|(% style="text-align:center; vertical-align:middle; width:141px" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Panel display**|(% style="text-align:center; vertical-align:middle" %)**Unit**|(% style="text-align:center; vertical-align:middle" %)**Data type**
2235 |(% style="text-align:center; vertical-align:middle; width:561px" %)The 1st warning code of the most recent|(% style="text-align:center; vertical-align:middle; width:141px" %)-|(% style="text-align:center; vertical-align:middle" %)Warning|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)16-bit
2236 |(% colspan="7" %)Display the 1st warning code of the most recent of servo drive
2237
2238 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**U1-22**|(% style="text-align:center; vertical-align:middle" %)**Monitoring name**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Panel display**|(% style="text-align:center; vertical-align:middle" %)**Unit**|(% style="text-align:center; vertical-align:middle" %)**Data type**
2239 |(% style="text-align:center; vertical-align:middle" %)The 2nd warning code of the most recent|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)Warning|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)16-bit
2240
2241 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**U1-23**|(% style="text-align:center; vertical-align:middle" %)**Monitoring name**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Panel display**|(% style="text-align:center; vertical-align:middle" %)**Unit**|(% style="text-align:center; vertical-align:middle" %)**Data type**
2242 |(% style="text-align:center; vertical-align:middle" %)The 3rd warning code of the most recent|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)Warning|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)16-bit
2243
2244 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**U1-24**|(% style="text-align:center; vertical-align:middle" %)**Monitoring name**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Panel display**|(% style="text-align:center; vertical-align:middle" %)**Unit**|(% style="text-align:center; vertical-align:middle" %)**Data type**
2245 |(% style="text-align:center; vertical-align:middle" %)The 4th warning code of the most recent|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)Warning|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)16-bit
2246
2247 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**U1-25**|(% style="text-align:center; vertical-align:middle" %)**Monitoring name**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Panel display**|(% style="text-align:center; vertical-align:middle" %)**Unit**|(% style="text-align:center; vertical-align:middle" %)**Data type**
2248 |(% style="text-align:center; vertical-align:middle" %)The 5th warning code of the most recent|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)Warning|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)16-bit
2249
2250 = **Group U2 Device monitoring** =
2251
2252 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**U2-01**|(% style="text-align:center; vertical-align:middle" %)**Monitoring name**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Panel display**|(% style="text-align:center; vertical-align:middle" %)**Unit**|(% style="text-align:center; vertical-align:middle" %)**Data type**
2253 |(% style="text-align:center; vertical-align:middle" %)Product series|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)Device|(% style="text-align:center; vertical-align:middle" %)Hexadecimal|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)16-bit
2254 |(% colspan="7" %)(((
2255 Display the product series code of servo drive.
2256
2257 The product series code of VD2A and VD2B is 0x4432. The product series code of VD2F is 0x3246.
2258
2259 There are displayed as below.
2260
2261 [[image:http://docs.we-con.com.cn/wiki/servo/download/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/WebHome/Wecon%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29_html_dd30cc3c7cd5315c.gif?rev=1.1||alt="Wecon VD2 SA Series Servo Drives Manual (Full V1.1)_html_dd30cc3c7cd5315c.gif"]] [[image:http://docs.we-con.com.cn/wiki/servo/download/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/WebHome/Wecon%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29_html_2d18d527e30dd030.gif?rev=1.1||alt="Wecon VD2 SA Series Servo Drives Manual (Full V1.1)_html_2d18d527e30dd030.gif"]]
2262 )))
2263
2264 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**U2-02**|(% style="text-align:center; vertical-align:middle" %)**Monitoring name**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Panel display**|(% style="text-align:center; vertical-align:middle" %)**Unit**|(% style="text-align:center; vertical-align:middle" %)**Data type**
2265 |(% style="text-align:center; vertical-align:middle" %)Model|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)Device|(% style="text-align:center; vertical-align:middle" %)Hexadecimal|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)16-bit
2266 |(% colspan="7" %)Display the servo drive model.(((
2267 |(% style="text-align:center; vertical-align:middle" %)**U2-01display**|(% style="text-align:center; vertical-align:middle" %)**U2-02 display**|(% style="text-align:center; vertical-align:middle" %)**Model**
2268 |(% rowspan="7" style="text-align:center; vertical-align:middle" %)[[image:http://docs.we-con.com.cn/wiki/servo/download/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/WebHome/Wecon%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29_html_381f805ee71c91ad.gif?rev=1.1||alt="Wecon VD2 SA Series Servo Drives Manual (Full V1.1)_html_381f805ee71c91ad.gif"]]|(% style="text-align:center; vertical-align:middle" %)[[image:http://docs.we-con.com.cn/wiki/servo/download/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/WebHome/Wecon%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29_html_e7ae4399b6c49a45.gif?rev=1.1||alt="Wecon VD2 SA Series Servo Drives Manual (Full V1.1)_html_e7ae4399b6c49a45.gif"]]|(% style="text-align:center; vertical-align:middle" %)VD2-010SA1G
2269 |(% style="text-align:center; vertical-align:middle" %)[[image:http://docs.we-con.com.cn/wiki/servo/download/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/WebHome/Wecon%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29_html_3bdfbf09b8ca5e03.gif?rev=1.1||alt="Wecon VD2 SA Series Servo Drives Manual (Full V1.1)_html_3bdfbf09b8ca5e03.gif"]]|(% style="text-align:center; vertical-align:middle" %)VD2-014SA1G
2270 |(% style="text-align:center; vertical-align:middle" %)[[image:http://docs.we-con.com.cn/wiki/servo/download/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/WebHome/Wecon%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29_html_6b1f0f493cf04b94.gif?rev=1.1||alt="Wecon VD2 SA Series Servo Drives Manual (Full V1.1)_html_6b1f0f493cf04b94.gif"]]|(% style="text-align:center; vertical-align:middle" %)VD2-016SA1G
2271 |(% style="text-align:center; vertical-align:middle" %)[[image:http://docs.we-con.com.cn/wiki/servo/download/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/WebHome/Wecon%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29_html_4a250ef1ebbbd4f7.gif?rev=1.1||alt="Wecon VD2 SA Series Servo Drives Manual (Full V1.1)_html_4a250ef1ebbbd4f7.gif"]]|(% style="text-align:center; vertical-align:middle" %)VD2-019SA1G
2272 |(% style="text-align:center; vertical-align:middle" %)[[image:http://docs.we-con.com.cn/wiki/servo/download/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/WebHome/Wecon%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29_html_7533aa9583498f11.gif?rev=1.1||alt="Wecon VD2 SA Series Servo Drives Manual (Full V1.1)_html_7533aa9583498f11.gif"]]|(% style="text-align:center; vertical-align:middle" %)VD2-021SA1G
2273 |(% style="text-align:center; vertical-align:middle" %)[[image:http://docs.we-con.com.cn/wiki/servo/download/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/WebHome/Wecon%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29_html_8aa34ef773dfbc08.gif?rev=1.1||alt="Wecon VD2 SA Series Servo Drives Manual (Full V1.1)_html_8aa34ef773dfbc08.gif"]]|(% style="text-align:center; vertical-align:middle" %)VD2-025SA1G
2274 |(% style="text-align:center; vertical-align:middle" %)[[image:http://docs.we-con.com.cn/wiki/servo/download/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/WebHome/Wecon%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29_html_cf0da0cfd71ae900.gif?rev=1.1||alt="Wecon VD2 SA Series Servo Drives Manual (Full V1.1)_html_cf0da0cfd71ae900.gif"]]|(% style="text-align:center; vertical-align:middle" %)VD2-030SA1G
2275 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)[[image:http://docs.we-con.com.cn/wiki/servo/download/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/WebHome/Wecon%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29_html_2d18d527e30dd030.gif?rev=1.1||alt="Wecon VD2 SA Series Servo Drives Manual (Full V1.1)_html_2d18d527e30dd030.gif"]]|(% style="text-align:center; vertical-align:middle" %)[[image:http://docs.we-con.com.cn/wiki/servo/download/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/WebHome/Wecon%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29_html_e7ae4399b6c49a45.gif?rev=1.1||alt="Wecon VD2 SA Series Servo Drives Manual (Full V1.1)_html_e7ae4399b6c49a45.gif"]]|(% style="text-align:center; vertical-align:middle" %)VD2F-010SA1P
2276 |(% style="text-align:center; vertical-align:middle" %)[[image:http://docs.we-con.com.cn/wiki/servo/download/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/WebHome/Wecon%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29_html_3bdfbf09b8ca5e03.gif?rev=1.1||alt="Wecon VD2 SA Series Servo Drives Manual (Full V1.1)_html_3bdfbf09b8ca5e03.gif"]]|(% style="text-align:center; vertical-align:middle" %)VD2F-014SA1P
2277 )))
2278
2279 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**U2-03**|(% style="text-align:center; vertical-align:middle" %)**Monitoring name**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Panel display**|(% style="text-align:center; vertical-align:middle" %)**Unit**|(% style="text-align:center; vertical-align:middle" %)**Data type**
2280 |(% style="text-align:center; vertical-align:middle" %)Model|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)Warning|(% style="text-align:center; vertical-align:middle" %)Hexadecimal|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)16-bit
2281
2282 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**U2-04**|(% style="text-align:center; vertical-align:middle" %)**Monitoring name**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Panel display**|(% style="text-align:center; vertical-align:middle" %)**Unit**|(% style="text-align:center; vertical-align:middle" %)**Data type**
2283 |(% style="text-align:center; vertical-align:middle" %)Firmware version|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)Device|(% style="text-align:center; vertical-align:middle" %)Decimal|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)16-bit
2284 |(% colspan="7" %)(((
2285 Display the firmware version
2286
2287 Display format: X.YY. For example, 1.13. The panel is displayed as below.
2288
2289 (% style="text-align:center" %)
2290 [[image:http://docs.we-con.com.cn/wiki/servo/download/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/WebHome/Wecon%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29_html_8848562a7d0ffab0.gif?rev=1.1||alt="Wecon VD2 SA Series Servo Drives Manual (Full V1.1)_html_8848562a7d0ffab0.gif"]]
2291 )))
2292
2293 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**U2-05**|(% style="text-align:center; vertical-align:middle" %)**Monitoring name**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Panel display**|(% style="text-align:center; vertical-align:middle" %)**Unit**|(% style="text-align:center; vertical-align:middle" %)**Data type**
2294 |(% style="text-align:center; vertical-align:middle" %)Hardware version|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)Device|(% style="text-align:center; vertical-align:middle" %)Decimal|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)16-bit
2295 |(% colspan="7" %)(((
2296 Display the hardware version (FPGA)
2297
2298 Display format: X.YY. For example, 1.01. The panel is displayed as below.
2299
2300 (% style="text-align:center" %)
2301 [[image:http://docs.we-con.com.cn/wiki/servo/download/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/WebHome/Wecon%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29_html_c1197549b8795572.gif?rev=1.1||alt="Wecon VD2 SA Series Servo Drives Manual (Full V1.1)_html_c1197549b8795572.gif"]]
2302 )))
2303
2304 |(% rowspan="3" style="text-align:center; vertical-align:middle" %)**U2-06**|(% style="text-align:center; vertical-align:middle" %)**Monitoring name**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Panel display**|(% style="text-align:center; vertical-align:middle" %)**Unit**|(% style="text-align:center; vertical-align:middle" %)**Data type**
2305 |(% style="text-align:center; vertical-align:middle" %)Manufacture date (year)|(% rowspan="2" style="text-align:center; vertical-align:middle" %)-|(% rowspan="2" style="text-align:center; vertical-align:middle" %)Device|(% rowspan="2" style="text-align:center; vertical-align:middle" %)Decimal|(% rowspan="2" style="text-align:center; vertical-align:middle" %)Year|(% rowspan="2" style="text-align:center; vertical-align:middle" %)16-bit
2306 |(% style="text-align:center; vertical-align:middle" %)Firmware date (year) *
2307 |(% colspan="7" %)Display the year of manufacture of the VD2F drive firmware.
2308
2309 |(% rowspan="3" style="text-align:center; vertical-align:middle" %)**U2-07**|(% style="text-align:center; vertical-align:middle" %)**Monitoring name**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Panel display**|(% style="text-align:center; vertical-align:middle" %)**Unit**|(% style="text-align:center; vertical-align:middle" %)**Data type**
2310 |(% style="text-align:center; vertical-align:middle" %)Manufacture date (month)|(% rowspan="2" style="text-align:center; vertical-align:middle" %)-|(% rowspan="2" style="text-align:center; vertical-align:middle" %)Device|(% rowspan="2" style="text-align:center; vertical-align:middle" %)Decimal|(% rowspan="2" style="text-align:center; vertical-align:middle" %)Month|(% rowspan="2" style="text-align:center; vertical-align:middle" %)16-bit
2311 |(% style="text-align:center; vertical-align:middle" %)Firmware date (month) *
2312 |(% colspan="7" %)Display the month of manufacture of the VD2F drive firmware.
2313
2314 |(% rowspan="3" style="text-align:center; vertical-align:middle" %)**U2-08**|(% style="text-align:center; vertical-align:middle; width:433px" %)**Monitoring name**|(% style="text-align:center; vertical-align:middle; width:131px" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Panel display**|(% style="text-align:center; vertical-align:middle" %)**Unit**|(% style="text-align:center; vertical-align:middle" %)**Data type**
2315 |(% style="text-align:center; vertical-align:middle; width:433px" %)Manufacture date (day)|(% rowspan="2" style="text-align:center; vertical-align:middle; width:131px" %)-|(% rowspan="2" style="text-align:center; vertical-align:middle" %)Device|(% rowspan="2" style="text-align:center; vertical-align:middle" %)Decimal|(% rowspan="2" style="text-align:center; vertical-align:middle" %)Day|(% rowspan="2" style="text-align:center; vertical-align:middle" %)16-bit
2316 |(% style="text-align:center; vertical-align:middle; width:433px" %)Firmware date (day) *
2317 |(% colspan="7" %)(((
2318 Displays the production date of the VD2F drive firmware.
2319
2320 For example, the firmware production day of VD2F-014SA1P_V1.01 is January 10, 2022, the panel is displayed as below.
2321
2322 |(% style="text-align:center; vertical-align:middle" %)**U2-06**|(% style="text-align:center; vertical-align:middle" %)**U2-07**|(% style="text-align:center; vertical-align:middle" %)**U2-08**
2323 |(% style="text-align:center; vertical-align:middle" %)[[image:http://docs.we-con.com.cn/wiki/servo/download/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/WebHome/Wecon%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29_html_e6b4c07070a56407.gif?rev=1.1||alt="Wecon VD2 SA Series Servo Drives Manual (Full V1.1)_html_e6b4c07070a56407.gif"]]|(% style="text-align:center; vertical-align:middle" %)[[image:http://docs.we-con.com.cn/wiki/servo/download/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/WebHome/Wecon%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29_html_19236aea37bae321.gif?rev=1.1||alt="Wecon VD2 SA Series Servo Drives Manual (Full V1.1)_html_19236aea37bae321.gif"]]|(% style="text-align:center; vertical-align:middle" %)[[image:http://docs.we-con.com.cn/wiki/servo/download/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/WebHome/Wecon%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29_html_4bd1f399b84d1801.gif?rev=1.1||alt="Wecon VD2 SA Series Servo Drives Manual (Full V1.1)_html_4bd1f399b84d1801.gif"]]
2324 )))
2325
2326 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**U2-09**|(% style="text-align:center; vertical-align:middle" %)**Monitoring name**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Panel display**|(% style="text-align:center; vertical-align:middle" %)**Unit**|(% style="text-align:center; vertical-align:middle" %)**Data type**
2327 |(% style="text-align:center; vertical-align:middle" %)Device serial number 1|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)Warning|(% style="text-align:center; vertical-align:middle" %)Decimal|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)16-bit
2328
2329 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**U2-10**|(% style="text-align:center; vertical-align:middle" %)**Monitoring name**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Panel display**|(% style="text-align:center; vertical-align:middle" %)**Unit**|(% style="text-align:center; vertical-align:middle" %)**Data type**
2330 |(% style="text-align:center; vertical-align:middle" %)Device serial number 2|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)Warning|(% style="text-align:center; vertical-align:middle" %)Decimal|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)16-bit
2331
2332 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**U2-11**|(% style="text-align:center; vertical-align:middle" %)**Monitoring name**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Panel display**|(% style="text-align:center; vertical-align:middle" %)**Unit**|(% style="text-align:center; vertical-align:middle" %)**Data type**
2333 |(% style="text-align:center; vertical-align:middle" %)Device serial number 3|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)Warning|(% style="text-align:center; vertical-align:middle" %)Decimal|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)16-bit
2334
2335 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**U2-12**|(% style="text-align:center; vertical-align:middle" %)**Monitoring name**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Panel display**|(% style="text-align:center; vertical-align:middle" %)**Unit**|(% style="text-align:center; vertical-align:middle" %)**Data type**
2336 |(% style="text-align:center; vertical-align:middle" %)Device serial number 4|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)Warning|(% style="text-align:center; vertical-align:middle" %)Decimal|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)16-bit
2337
2338 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**U2-13**|(% style="text-align:center; vertical-align:middle" %)**Monitoring name**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Panel display**|(% style="text-align:center; vertical-align:middle" %)**Unit**|(% style="text-align:center; vertical-align:middle" %)**Data type**
2339 |(% style="text-align:center; vertical-align:middle" %)Device serial number 5|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)Warning|(% style="text-align:center; vertical-align:middle" %)Decimal|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)16-bit
2340
2341 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**U2-14**|(% style="text-align:center; vertical-align:middle" %)**Monitoring name**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Panel display**|(% style="text-align:center; vertical-align:middle" %)**Unit**|(% style="text-align:center; vertical-align:middle" %)**Data type**
2342 |(% style="text-align:center; vertical-align:middle" %)Device serial number 6|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)Warning|(% style="text-align:center; vertical-align:middle" %)Decimal|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)16-bit
2343
2344 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**U2-15**|(% style="text-align:center; vertical-align:middle" %)**Monitoring name**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Panel display**|(% style="text-align:center; vertical-align:middle" %)**Unit**|(% style="text-align:center; vertical-align:middle" %)**Data type**
2345 |(% style="text-align:center; vertical-align:middle" %)Device serial number 7|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)Warning|(% style="text-align:center; vertical-align:middle" %)Decimal|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)16-bit
2346
2347 |(% rowspan="2" style="text-align:center; vertical-align:middle" %)**U2-16**|(% style="text-align:center; vertical-align:middle" %)**Monitoring name**|(% style="text-align:center; vertical-align:middle" %)**Range**|(% style="text-align:center; vertical-align:middle" %)**Category**|(% style="text-align:center; vertical-align:middle" %)**Panel display**|(% style="text-align:center; vertical-align:middle" %)**Unit**|(% style="text-align:center; vertical-align:middle" %)**Data type**
2348 |(% style="text-align:center; vertical-align:middle" %)Device serial number 8|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)Warning|(% style="text-align:center; vertical-align:middle" %)Decimal|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)16-bit