Changes for page 10 Malfunctions
Last modified by Iris on 2025/09/08 10:50
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -723,7 +723,7 @@ 723 723 |=(% style="width: 212px;" %)**Reason**|=(% style="width: 463px;" %)**Troubleshooting methods**|=(% style="width: 401px;" %)**Handling** 724 724 |(% style="width:212px" %)External interference|(% style="width:463px" %)Check that the motor and servo drive are well grounded|(% style="width:401px" %)Motor and servo drive are well grounded 725 725 |(% style="width:212px" %)Encoder cable fault|(% style="width:463px" %)Cross-verification. Use the normal motor, encoder cable to connect to the servo drive.|(% style="width:401px" %)Replace it with an encoder cable with higher connection reliability. 726 -|(% style="width:212px" %)Servo drive fault|(% style="width:463px" %)The servo drive is still faulty after power on again|(% style="width:401px" %)Servo drive may be damaged.Contact technician for repair 726 +|(% style="width:212px" %)Servo drive fault|(% style="width:463px" %)The servo drive is still faulty after power on again|(% style="width:401px" %)Servo drive may be damaged. Contact technician for repair 727 727 728 728 **Er.31 Power line disconnection** 729 729 ... ... @@ -994,11 +994,11 @@ 994 994 Fault 995 995 996 996 997 -|=(% style="width: 794px;" %)**Servo drive panel display**|=(% style="width:627px;" %)**Fault name**998 -|(% style="width: 794px" %) (((997 +|=(% style="width: 394px;" %)**Servo drive panel display**|=(% style="width: 529px;" %)**Fault name** 998 +|(% style="width:394px" %) ((( 999 999 (% style="text-align:center" %) 1000 -[[image:企业微信截图_16877625944107.png]] 1001 -)))|(% style="width: 627px" %)Drive overload fault1000 +[[image:企业微信截图_16877625944107.png||height="57" width="156"]] 1001 +)))|(% style="width:529px" %)Drive overload fault 1002 1002 1003 1003 Troubleshooting 1004 1004 ... ... @@ -1006,6 +1006,27 @@ 1006 1006 |The average output power (U0-34) exceeds the limit power (overload 110%) for more than 20 minutes.|Whether the average output power (U0-34) often exceeds the limit (overload 110) Check whether the drive meets the requirements.|Observed whether the U0-34 is often greater than the servo limit power (overload 110%) during servo operation. When ER.43 alarm is found in the process of machine adjustment, please check whether the servo power is suitable. It is recommended to replace the driver model with higher power. 1007 1007 |Servo drive fault|The servo drive is still faulty after power on again|Servo drive may be damaged, contact the manufacturer's technician for repair. 1008 1008 1009 +**Er.44 Return to origin timeout failure** 1010 + 1011 +Fault 1012 + 1013 +(% style="margin-left:auto; margin-right:auto" %) 1014 +|(% style="width:403px" %)**Servo drive panel display**|(% style="width:520px" %)**Fault name** 1015 +|(% style="width:403px" %)((( 1016 + 1017 + 1018 + [[image:1757296062376-469.png||height="61" width="160"]] 1019 +)))|(% style="width:520px" %)Return to origin timeout failure 1020 + 1021 +Troubleshooting 1022 + 1023 +|**Reason**|**Troubleshooting**|**Treatment** 1024 +|(% rowspan="2" %)Return-to-origin switch failure|Checks if the origin regression was always in high-speed search, and not low-speed search;|(% rowspan="2" %) First confirm whether the PI function 26 is set by the P06 group, then check the DI terminal connection, and when manually changing the DI terminal logic, check whether the servo driver receives the corresponding DI level signal through U0-17. If it is not received, it means that the DI switch is wired incorrectly, please wire it correctly; when manually changing the logic of the DI terminal, if there is a received level signal, it means that there is an error in the origin regression operation, please operate it correctly. 1025 +| Checks if the origin regression high-speed search has been in the reverse low-speed search process. 1026 +|The speed of searching for the origin switch signal at high speed is too small|Check if the P01-41 setting value is too small|Servo drive may be damaged, contact manufacturer technician for repair. 1027 +|(% rowspan="2" %)Unreasonable hardware switch settings|Confirm whether the limit switch signals on both sides are in valid at the same time;|(% rowspan="2" %)Set hardware switch positions reasonably. 1028 +|Confirm whether a certain limit switch signal is valid at the same time as the deceleration point signal or the origin signal. 1029 + 1009 1009 **Er.45 Drive Blocking Overtemperature Protection** 1010 1010 1011 1011 Fault ... ... @@ -1021,9 +1021,6 @@ 1021 1021 |=Reason|=Troubleshooting|=Treatment 1022 1022 |Check whether U0-39 load torque percentage exceeds the maximum torque of the motor for 3 seconds or observe whether the load torque at the waveform interface of the oscilloscope of the upper computer is greater than the maximum torque of the motor and the motor is blocked.|Check whether U0-39 load torque percentage exceeds the maximum torque of the motor, and observe whether the motor is stuck.|Observable maximum torque observe whether the load torque on the waveform interface of the host computer oscilloscope is greater than the motor maximum torque or check whether U0-39 load torque percentage exceeds the motor maximum torque for 3 seconds. 1023 1023 1024 -(% style="text-align:center" %) 1025 -[[image:1687762670698-912.png]] 1026 - 1027 1027 **Er.60 ADC conversion is not complete** 1028 1028 1029 1029 Fault ... ... @@ -1135,8 +1135,25 @@ 1135 1135 1136 1136 )))|Check whether the average output power (U0-34) exceeds the limit (overload 110) The average output power (U0-34) exceeds the limit power (overload 110%) for more than 5 minutes. Check whether the U0-34 exceeds 110% of the rated power of the driver.|Check whether the U0-34 exceeds 110% of the rated power of the driver. When A80 alarm is found in the process of machine adjustment, please check whether the servo power is suitable. 1137 1137 1138 -(% style="text-align:center" %) 1139 -[[image:1687763249516-252.png]] 1156 +(% style="margin-left:auto; margin-right:auto" %) 1157 +|**Servo-drive Model**|**Power rating/W**|**Limit power/W(110%overload)** 1158 +|VD2-010SA1G/SA1H|400|440 1159 +|VD2-014SA1G/SA1H|750|825 1160 +|VD2-016SA1G/SA1H|1500|1650 1161 +|VD2-019SA1G/SA1H|2300|2530 1162 +|VD2-021SA1G/SA1H|2300|2530 1163 +|VD2-025SA1G/SA1H|2600|2860 1164 +|VD2-030SA1G/SA1H|2600|2860 1165 +|VD2F-010SA1P|400|440 1166 +|VD2F-014SA1P|750|825 1167 +|VD2-016TA1G/TA1H|1500|1650 1168 +|VD2-019TA1G/TA1H|2000|2200 1169 +|VD2-021TA1G /TA1H|3000|3300 1170 +|VD2-030TA1G|4000|4400 1171 +|VD2-040TA1G|6000|6600 1172 +|VD2-050TA1G|7500|8250 1173 +|VD2L-010SA1P|400|440 1174 +|VD2L-014SA1P|750|825 1140 1140 1141 1141 **A-81 Overspeed alarm** 1142 1142 ... ... @@ -1219,7 +1219,9 @@ 1219 1219 |(% style="width:454px" %)((( 1220 1220 (% style="text-align:center" %) 1221 1221 [[image:image-20220709171124-11.png]] 1222 -)))|(% style="width:621px" %)Modified parameters that need to be powered on again to take effect 1257 +)))|(% style="width:621px" %)((( 1258 +Parameter modification that needs to be powered on again 1259 +))) 1223 1223 1224 1224 Troubleshooting 1225 1225 ... ... @@ -1226,26 +1226,6 @@ 1226 1226 |=(% style="width: 316px;" %)**Reason**|=(% style="width: 541px;" %)**Troubleshooting methods**|=(% style="width: 219px;" %)**Handling** 1227 1227 |(% style="width:316px" %)Modified the effective timing to "power on again" parameter.|(% style="width:541px" %)Check whether the servo drive has modified the parameter with the effective time "power on again".|(% style="width:219px" %)Power on again 1228 1228 1229 -**A-85 Receive position pulse when servo is OFF** 1230 - 1231 -Fault 1232 - 1233 -|=(% style="width: 465px;" %)**Servo drive panel display**|=(% style="width: 610px;" %)**Fault name** 1234 -|(% style="width:465px" %)((( 1235 -(% style="text-align:center" %) 1236 -[[image:image-20220709171137-12.png]] 1237 -)))|(% style="width:610px" %)Receive position pulse when servo is OFF 1238 - 1239 -Troubleshooting 1240 - 1241 -|=(% style="width: 270px;" %)**Reason**|=(% style="width: 502px;" %)**Troubleshooting methods**|=(% style="width: 304px;" %)**Handling** 1242 -|(% style="width:270px" %)Servo received position pulse when it is OFF.|(% style="width:502px" %)Check whether the servo drive is in the OFF state, and check whether the host computer is sending pulse instruction.|(% rowspan="2" style="width:304px" %)The host computer stops sending pulse instructions. 1243 -|(% style="width:270px" %)Servo received pulse instruction in non-position mode|(% style="width:502px" %)((( 1244 -Check whether the servo drive P00-01 (control mode) is in position mode; 1245 - 1246 -Check whether the host computer is sending pulse instructions 1247 -))) 1248 - 1249 1249 **A-86 Input pulse frequency is too high** 1250 1250 1251 1251 Fault
- 1757296062376-469.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Iris - Size
-
... ... @@ -1,0 +1,1 @@ 1 +18.2 KB - Content