Changes for page 10 Malfunctions
Last modified by Iris on 2026/04/17 16:14
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -951,7 +951,7 @@ 951 951 Troubleshooting 952 952 953 953 |=(% style="width: 361px;" %)**Reason**|=(% style="width: 395px;" %)**Troubleshooting methods**|=(% style="width: 320px;" %)**Handling** 954 -|(% style="width:361px" %)Multi-turn absolute encoder is not connected to the battery during the power off of the servo drive|(% style="width:395px" %)Check if the encoder is connected to the battery during the power off of the servo|(% style="width:320px" %) Set P10-03(Fault clearing)to 1954 +|(% style="width:361px" %)Multi-turn absolute encoder is not connected to the battery during the power off of the servo drive|(% style="width:395px" %)Check if the encoder is connected to the battery during the power off of the servo|(% style="width:320px" %)After setting P10-06 (multi-turn absolute encoder reset) to 1, set P10-03 (clear fault) to 1. 955 955 |(% style="width:361px" %)The voltage of multi-turn absolute encoder battery is low|(% style="width:395px" %)Measure battery voltage|(% style="width:320px" %)Contact technicians to replace with a new encoder battery 956 956 957 957 **Er.41 Motor (encoder) over temperature** ... ... @@ -1006,6 +1006,27 @@ 1006 1006 |The average output power (U0-34) exceeds the limit power (overload 110%) for more than 20 minutes.|Whether the average output power (U0-34) often exceeds the limit (overload 110) Check whether the drive meets the requirements.|Observed whether the U0-34 is often greater than the servo limit power (overload 110%) during servo operation. When ER.43 alarm is found in the process of machine adjustment, please check whether the servo power is suitable. It is recommended to replace the driver model with higher power. 1007 1007 |Servo drive fault|The servo drive is still faulty after power on again|Servo drive may be damaged, contact the manufacturer's technician for repair. 1008 1008 1009 +|**Servo drive model**|**Rated power/W**|**Limited power/W(110% overload)** 1010 +|VD2-010SA1G/SA1H|400|440 1011 +|VD2-014SA1G/SA1H|750|825 1012 +|VD2-016SA1G/SA1H|1500|1650 1013 +|VD2-019SA1G/SA1H|2300|2530 1014 +|VD2-021SA1G/SA1H|2300|2530 1015 +|VD2-025SA1G/SA1H|2600|2860 1016 +|VD2-030SA1G/SA1H|2600|2860 1017 +|VD2-016TA1G/TA1H|1500|1650 1018 +|VD2-019TA1G/TA1H|2000|2250 1019 +|VD2-021TA1G/TA1H|3000|3300 1020 +|VD2-030TA1G|4000|4400 1021 +|VD2-040TA1G|6000|6600 1022 +|VD2-050TA1G|7500|8250 1023 +|VD2L-003SA1P|100|110 1024 +|VD2L-010SA1P/SA1D|400|440 1025 +|VD2L-014SA1P/SA1D|750|825 1026 +|VD2F-003SA1P|100|110 1027 +|VD2F-010SA1P|400|440 1028 +|VD2F-014SA1P|750|825 1029 + 1009 1009 **Er.44 Return to origin timeout failure** 1010 1010 1011 1011 Fault ... ... @@ -1042,9 +1042,6 @@ 1042 1042 |=Reason|=Troubleshooting|=Treatment 1043 1043 |Check whether U0-39 load torque percentage exceeds the maximum torque of the motor for 3 seconds or observe whether the load torque at the waveform interface of the oscilloscope of the upper computer is greater than the maximum torque of the motor and the motor is blocked.|Check whether U0-39 load torque percentage exceeds the maximum torque of the motor, and observe whether the motor is stuck.|Observable maximum torque observe whether the load torque on the waveform interface of the host computer oscilloscope is greater than the motor maximum torque or check whether U0-39 load torque percentage exceeds the motor maximum torque for 3 seconds. 1044 1044 1045 -(% style="text-align:center" %) 1046 -[[image:1687762670698-912.png]] 1047 - 1048 1048 **Er.60 ADC conversion is not complete** 1049 1049 1050 1050 Fault ... ... @@ -1156,8 +1156,26 @@ 1156 1156 1157 1157 )))|Check whether the average output power (U0-34) exceeds the limit (overload 110) The average output power (U0-34) exceeds the limit power (overload 110%) for more than 5 minutes. Check whether the U0-34 exceeds 110% of the rated power of the driver.|Check whether the U0-34 exceeds 110% of the rated power of the driver. When A80 alarm is found in the process of machine adjustment, please check whether the servo power is suitable. 1158 1158 1159 -(% style="text-align:center" %) 1160 -[[image:1687763249516-252.png]] 1177 +|**Servo-drive model**|**Rated power /W**|**Limited power/W (110%overload)** 1178 +|VD2-010SA1G/SA1H|400|440 1179 +|VD2-014SA1G/SA1H|750|825 1180 +|VD2-016SA1G/SA1H|1500|1650 1181 +|VD2-019SA1G/SA1H|2300|2530 1182 +|VD2-021SA1G/SA1H|2300|2530 1183 +|VD2-025SA1G/SA1H|2600|2860 1184 +|VD2-030SA1G/SA1H|2600|2860 1185 +|VD2F-003SA1P|100|110 1186 +|VD2F-010SA1P|400|440 1187 +|VD2F-014SA1P|750|825 1188 +|VD2-016TA1G/TA1H|1500|1650 1189 +|VD2-019TA1G/TA1H|2000|2200 1190 +|VD2-021TA1G /TA1H|3000|3300 1191 +|VD2-030TA1G|4000|4400 1192 +|VD2-040TA1G|6000|6600 1193 +|VD2-050TA1G|7500|8250 1194 +|VD2L-003SA1P|100|110 1195 +|VD2L-010SA1P/SA1D|400|440 1196 +|VD2L-014SA1P/SA1D|750|825 1161 1161 1162 1162 **A-81 Overspeed alarm** 1163 1163 ... ... @@ -1240,7 +1240,9 @@ 1240 1240 |(% style="width:454px" %)((( 1241 1241 (% style="text-align:center" %) 1242 1242 [[image:image-20220709171124-11.png]] 1243 -)))|(% style="width:621px" %)Modified parameters that need to be powered on again to take effect 1279 +)))|(% style="width:621px" %)((( 1280 +Parameter modification that needs to be powered on again 1281 +))) 1244 1244 1245 1245 Troubleshooting 1246 1246 ... ... @@ -1247,26 +1247,6 @@ 1247 1247 |=(% style="width: 316px;" %)**Reason**|=(% style="width: 541px;" %)**Troubleshooting methods**|=(% style="width: 219px;" %)**Handling** 1248 1248 |(% style="width:316px" %)Modified the effective timing to "power on again" parameter.|(% style="width:541px" %)Check whether the servo drive has modified the parameter with the effective time "power on again".|(% style="width:219px" %)Power on again 1249 1249 1250 -**A-85 Receive position pulse when servo is OFF** 1251 - 1252 -Fault 1253 - 1254 -|=(% style="width: 465px;" %)**Servo drive panel display**|=(% style="width: 610px;" %)**Fault name** 1255 -|(% style="width:465px" %)((( 1256 -(% style="text-align:center" %) 1257 -[[image:image-20220709171137-12.png]] 1258 -)))|(% style="width:610px" %)Receive position pulse when servo is OFF 1259 - 1260 -Troubleshooting 1261 - 1262 -|=(% style="width: 270px;" %)**Reason**|=(% style="width: 502px;" %)**Troubleshooting methods**|=(% style="width: 304px;" %)**Handling** 1263 -|(% style="width:270px" %)Servo received position pulse when it is OFF.|(% style="width:502px" %)Check whether the servo drive is in the OFF state, and check whether the host computer is sending pulse instruction.|(% rowspan="2" style="width:304px" %)The host computer stops sending pulse instructions. 1264 -|(% style="width:270px" %)Servo received pulse instruction in non-position mode|(% style="width:502px" %)((( 1265 -Check whether the servo drive P00-01 (control mode) is in position mode; 1266 - 1267 -Check whether the host computer is sending pulse instructions 1268 -))) 1269 - 1270 1270 **A-86 Input pulse frequency is too high** 1271 1271 1272 1272 Fault