Changes for page 10 Malfunctions

Last modified by Iris on 2026/04/17 16:14

From version 2.1
edited by Iris
on 2026/04/17 14:17
Change comment: There is no comment for this version
To version 1.10
edited by Iris
on 2025/09/08 10:50
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -951,7 +951,7 @@
951 951  Troubleshooting
952 952  
953 953  |=(% style="width: 361px;" %)**Reason**|=(% style="width: 395px;" %)**Troubleshooting methods**|=(% style="width: 320px;" %)**Handling**
954 -|(% style="width:361px" %)Multi-turn absolute encoder is not connected to the battery during the power off of the servo drive|(% style="width:395px" %)Check if the encoder is connected to the battery during the power off of the servo|(% style="width:320px" %)After setting P10-06 (multi-turn absolute encoder reset) to 1, set P10-03 (clear fault) to 1.
954 +|(% style="width:361px" %)Multi-turn absolute encoder is not connected to the battery during the power off of the servo drive|(% style="width:395px" %)Check if the encoder is connected to the battery during the power off of the servo|(% style="width:320px" %)Set P10-03 (Fault clearing) to 1
955 955  |(% style="width:361px" %)The voltage of multi-turn absolute encoder battery is low|(% style="width:395px" %)Measure battery voltage|(% style="width:320px" %)Contact technicians to replace with a new encoder battery
956 956  
957 957  **Er.41 Motor (encoder) over temperature**
... ... @@ -1006,27 +1006,6 @@
1006 1006  |The average output power (U0-34) exceeds the limit power (overload 110%) for more than 20 minutes.|Whether the average output power (U0-34) often exceeds the limit (overload 110) Check whether the drive meets the requirements.|Observed whether the U0-34 is often greater than the servo limit power (overload 110%) during servo operation. When ER.43 alarm is found in the process of machine adjustment, please check whether the servo power is suitable. It is recommended to replace the driver model with higher power.
1007 1007  |Servo drive fault|The servo drive is still faulty after power on again|Servo drive may be damaged, contact the manufacturer's technician for repair.
1008 1008  
1009 -|**Servo drive model**|**Rated power/W**|**Limited power/W(110% overload)**
1010 -|VD2-010SA1G/SA1H|400|440
1011 -|VD2-014SA1G/SA1H|750|825
1012 -|VD2-016SA1G/SA1H|1500|1650
1013 -|VD2-019SA1G/SA1H|2300|2530
1014 -|VD2-021SA1G/SA1H|2300|2530
1015 -|VD2-025SA1G/SA1H|2600|2860
1016 -|VD2-030SA1G/SA1H|2600|2860
1017 -|VD2-016TA1G/TA1H|1500|1650
1018 -|VD2-019TA1G/TA1H|2000|2250
1019 -|VD2-021TA1G/TA1H|3000|3300
1020 -|VD2-030TA1G|4000|4400
1021 -|VD2-040TA1G|6000|6600
1022 -|VD2-050TA1G|7500|8250
1023 -|VD2L-003SA1P|100|110
1024 -|VD2L-010SA1P/SA1D|400|440
1025 -|VD2L-014SA1P/SA1D|750|825
1026 -|VD2F-003SA1P|100|110
1027 -|VD2F-010SA1P|400|440
1028 -|VD2F-014SA1P|750|825
1029 -
1030 1030  **Er.44 Return to origin timeout failure**
1031 1031  
1032 1032  Fault
... ... @@ -1174,7 +1174,8 @@
1174 1174  
1175 1175  )))|Check whether the average output power (U0-34) exceeds the limit (overload 110) The average output power (U0-34) exceeds the limit power (overload 110%) for more than 5 minutes. Check whether the U0-34 exceeds 110% of the rated power of the driver.|Check whether the U0-34 exceeds 110% of the rated power of the driver. When A80 alarm is found in the process of machine adjustment, please check whether the servo power is suitable.
1176 1176  
1177 -|**Servo-drive model**|**Rated power /W**|**Limited power/W (110%overload)**
1156 +(% style="margin-left:auto; margin-right:auto" %)
1157 +|**Servo-drive Model**|**Power rating/W**|**Limit power/W(110%overload)**
1178 1178  |VD2-010SA1G/SA1H|400|440
1179 1179  |VD2-014SA1G/SA1H|750|825
1180 1180  |VD2-016SA1G/SA1H|1500|1650
... ... @@ -1182,18 +1182,16 @@
1182 1182  |VD2-021SA1G/SA1H|2300|2530
1183 1183  |VD2-025SA1G/SA1H|2600|2860
1184 1184  |VD2-030SA1G/SA1H|2600|2860
1185 -|VD2F-003SA1P|100|110
1186 1186  |VD2F-010SA1P|400|440
1187 1187  |VD2F-014SA1P|750|825
1188 1188  |VD2-016TA1G/TA1H|1500|1650
1189 1189  |VD2-019TA1G/TA1H|2000|2200
1190 -|VD2-021TA1G /TA1H|3000|3300
1169 +|VD2-021TA1G /TA1H|3000|3300
1191 1191  |VD2-030TA1G|4000|4400
1192 1192  |VD2-040TA1G|6000|6600
1193 1193  |VD2-050TA1G|7500|8250
1194 -|VD2L-003SA1P|100|110
1195 -|VD2L-010SA1P/SA1D|400|440
1196 -|VD2L-014SA1P/SA1D|750|825
1173 +|VD2L-010SA1P|400|440
1174 +|VD2L-014SA1P|750|825
1197 1197  
1198 1198  **A-81 Overspeed alarm**
1199 1199