Changes for page 10 Malfunctions
Last modified by Iris on 2026/04/17 16:14
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -830,19 +830,11 @@ 830 830 831 831 |=(% style="width: 299px;" %)**Reason**|=(% style="width: 457px;" %)**Troubleshooting methods**|=(% style="width: 320px;" %)**Handling** 832 832 |(% style="width:299px" %)The electronic gear ratio setting is greater than the settable range|(% style="width:457px" %)((( 833 -Check that the ratio of function codes P0 1-17/P01-18, P01-19/P00-20 is in the following range.833 +Check that the ratio of function codes P00-17/P00-18, P00-19/P00-20 is in the following range. 834 834 835 -17bit absolute encoder upper limit value: 835 +17bit absolute encoder upper limit value: 500. 836 836 837 -VD2, VD2F, 13108; 838 - 839 -VD2:1311 840 - 841 -23bit absolute encoder upper limit value: 842 - 843 -VD2, VD2F: 838861; 844 - 845 -VD2L: 83887 837 +23bit absolute encoder upper limit value: 32000 846 846 )))|(% rowspan="2" style="width:320px" %)After modifying the corresponding function code according to the range, set P10-03 (fault clearance) to 1. 847 847 |(% style="width:299px" %)The electronic gear ratio setting is less than the settable range|(% style="width:457px" %)((( 848 848 Check that the ratio of function codes P00-17/P00-18, P00-19/P00-20 is in the following range. ... ... @@ -959,7 +959,7 @@ 959 959 Troubleshooting 960 960 961 961 |=(% style="width: 361px;" %)**Reason**|=(% style="width: 395px;" %)**Troubleshooting methods**|=(% style="width: 320px;" %)**Handling** 962 -|(% style="width:361px" %)Multi-turn absolute encoder is not connected to the battery during the power off of the servo drive|(% style="width:395px" %)Check if the encoder is connected to the battery during the power off of the servo|(% style="width:320px" %) After settingP10-06(multi-turnabsolute encoder reset) to 1, set P10-03 (clearfault) to 1.954 +|(% style="width:361px" %)Multi-turn absolute encoder is not connected to the battery during the power off of the servo drive|(% style="width:395px" %)Check if the encoder is connected to the battery during the power off of the servo|(% style="width:320px" %)Set P10-03 (Fault clearing) to 1 963 963 |(% style="width:361px" %)The voltage of multi-turn absolute encoder battery is low|(% style="width:395px" %)Measure battery voltage|(% style="width:320px" %)Contact technicians to replace with a new encoder battery 964 964 965 965 **Er.41 Motor (encoder) over temperature** ... ... @@ -1014,27 +1014,6 @@ 1014 1014 |The average output power (U0-34) exceeds the limit power (overload 110%) for more than 20 minutes.|Whether the average output power (U0-34) often exceeds the limit (overload 110) Check whether the drive meets the requirements.|Observed whether the U0-34 is often greater than the servo limit power (overload 110%) during servo operation. When ER.43 alarm is found in the process of machine adjustment, please check whether the servo power is suitable. It is recommended to replace the driver model with higher power. 1015 1015 |Servo drive fault|The servo drive is still faulty after power on again|Servo drive may be damaged, contact the manufacturer's technician for repair. 1016 1016 1017 -|**Servo drive model**|**Rated power/W**|**Limited power/W(110% overload)** 1018 -|VD2-010SA1G/SA1H|400|440 1019 -|VD2-014SA1G/SA1H|750|825 1020 -|VD2-016SA1G/SA1H|1500|1650 1021 -|VD2-019SA1G/SA1H|2300|2530 1022 -|VD2-021SA1G/SA1H|2300|2530 1023 -|VD2-025SA1G/SA1H|2600|2860 1024 -|VD2-030SA1G/SA1H|2600|2860 1025 -|VD2-016TA1G/TA1H|1500|1650 1026 -|VD2-019TA1G/TA1H|2000|2250 1027 -|VD2-021TA1G/TA1H|3000|3300 1028 -|VD2-030TA1G|4000|4400 1029 -|VD2-040TA1G|6000|6600 1030 -|VD2-050TA1G|7500|8250 1031 -|VD2L-003SA1P|100|110 1032 -|VD2L-010SA1P/SA1D|400|440 1033 -|VD2L-014SA1P/SA1D|750|825 1034 -|VD2F-003SA1P|100|110 1035 -|VD2F-010SA1P|400|440 1036 -|VD2F-014SA1P|750|825 1037 - 1038 1038 **Er.44 Return to origin timeout failure** 1039 1039 1040 1040 Fault ... ... @@ -1182,7 +1182,8 @@ 1182 1182 1183 1183 )))|Check whether the average output power (U0-34) exceeds the limit (overload 110) The average output power (U0-34) exceeds the limit power (overload 110%) for more than 5 minutes. Check whether the U0-34 exceeds 110% of the rated power of the driver.|Check whether the U0-34 exceeds 110% of the rated power of the driver. When A80 alarm is found in the process of machine adjustment, please check whether the servo power is suitable. 1184 1184 1185 -|**Servo-drive model**|**Rated power /W**|**Limited power/W (110%overload)** 1156 +(% style="margin-left:auto; margin-right:auto" %) 1157 +|**Servo-drive Model**|**Power rating/W**|**Limit power/W(110%overload)** 1186 1186 |VD2-010SA1G/SA1H|400|440 1187 1187 |VD2-014SA1G/SA1H|750|825 1188 1188 |VD2-016SA1G/SA1H|1500|1650 ... ... @@ -1190,18 +1190,16 @@ 1190 1190 |VD2-021SA1G/SA1H|2300|2530 1191 1191 |VD2-025SA1G/SA1H|2600|2860 1192 1192 |VD2-030SA1G/SA1H|2600|2860 1193 -|VD2F-003SA1P|100|110 1194 1194 |VD2F-010SA1P|400|440 1195 1195 |VD2F-014SA1P|750|825 1196 1196 |VD2-016TA1G/TA1H|1500|1650 1197 1197 |VD2-019TA1G/TA1H|2000|2200 1198 -|VD2-021TA1G /TA1H|3000|33001169 +|VD2-021TA1G /TA1H|3000|3300 1199 1199 |VD2-030TA1G|4000|4400 1200 1200 |VD2-040TA1G|6000|6600 1201 1201 |VD2-050TA1G|7500|8250 1202 -|VD2L-003SA1P|100|110 1203 -|VD2L-010SA1P/SA1D|400|440 1204 -|VD2L-014SA1P/SA1D|750|825 1173 +|VD2L-010SA1P|400|440 1174 +|VD2L-014SA1P|750|825 1205 1205 1206 1206 **A-81 Overspeed alarm** 1207 1207