... ... @@ -145,10 +145,6 @@
145 145  
146 146  = **Overview** =
147 147  
148 -
149 -(% style="text-align:center" %)
150 -[[image:ksjakfjk.png]]
151 -
152 152  The faults and warnings of Wecon VD2 series servo drives are graded according to their severity, which can be divided into four grades: Category 1, Category 2, Category 3, Category 4. Severity level: Category 1> Category 2> Category 3 > Category 4, the specific classifications are as follows:
153 153  
154 154  Category 1: faults cannot be cleared;
... ... @@ -165,7 +165,10 @@
165 165  1. The clearing method of category 2 and category 3 clearable faults: first turn off the servo enable signal (set S-ON to OFF), then set P10-03=1 or use DI function 02.
166 166  1. The clearing method of category 4 of clearable warnings: set P10-03=1 or use DI function 02.
167 167  
168 -|(% style="text-align:center; vertical-align:middle" %)[[image:image-20220611141935-1.png]]
164 +|(% style="text-align:center; vertical-align:middle" %)(((
165 +(% style="text-align:center" %)
166 +[[image:ksjakfjk.png]]
167 +)))
169 169  |For some faults and warnings, you must change the settings to eliminate the causes before they can be cleared, but clearing does not mean that the changes take effect. For the changes that need to be re-powered to take effect, the power must be re-powered. For the changes that need to be stopped to take effect, the servo enable must be turned off. After the change takes effect, the servo drive can operate normally.