Changes for page 10 Malfunctions
Last modified by Theodore Xu on 2025/02/13 17:16
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 0 removed)
Details
- Page properties
-
- Parent
-
... ... @@ -1,1 +1,1 @@ 1 -Servo. 1 UserManual.02 VD2 SA Series.WebHome1 +Servo.Manual.02 VD2 SA Series.WebHome - Content
-
... ... @@ -297,7 +297,7 @@ 297 297 check abnormal and frequency is too high 298 298 )))|(% style="width:96px" %)Yes|(% style="width:115px" %)Continue to run 299 299 300 -= =**Troubleshooting** ==300 += **Troubleshooting** = 301 301 302 302 **Er.01 Parameter destruction** 303 303 ... ... @@ -304,7 +304,7 @@ 304 304 Fault 305 305 306 306 |=(% style="width: 460px;" %)**Servo drive panel display**|=(% style="width: 615px;" %)**Fault name** 307 -|(% style="width:460px" %)[[image:image-202207091 65342-1.png]]|(% style="width:615px" %)Parameter destruction307 +|(% style="width:460px" %)[[image:image-20220709173736-1.png]]|(% style="width:615px" %)Parameter destruction 308 308 309 309 Troubleshooting 310 310 ... ... @@ -956,7 +956,6 @@ 956 956 Priority is given to the use of motor power lines and encoder cables as standard by manufacturers 957 957 ))) 958 958 |(% style="width:233px" %)The load is too large|(% style="width:454px" %)Check overload characteristics of motor or servo drive|Reduce the load. Contact technical to obtain the appropriate capacity drive and motor model. 959 -|(% style="width:233px" %)Frequent acceleration and deceleration|(% style="width:454px" %)Check whether the acceleration and deceleration motion is frequent or the acceleration and deceleration time is too small|Appropriately extend the acceleration and deceleration time 960 960 |(% style="width:233px" %)Motor model and servo driver do not match|(% style="width:454px" %)Perform inertia identification and check the inertia ratio.|Contact technician to obtain the matching motor model. 961 961 |(% style="width:233px" %)Motor model and servo driver do not match|(% style="width:454px" %)Check the monitoring quantity U0-53 (motor model code).|Contact technician to obtain the matching motor model. 962 962 |(% rowspan="2" style="width:233px" %)Unreasonable parameters|(% style="width:454px" %)Use Wecon SCTools to obtain the actual torque waveform and observe whether overshoot is obvious|Set the appropriate loop gain parameters
- image-20220709173736-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Stone - Size
-
... ... @@ -1,0 +1,1 @@ 1 +33.4 KB - Content