... ... @@ -19,21 +19,21 @@
19 19  )))
20 20  |(% style="vertical-align:middle; width:163px" %)Control the supply voltage failure|(% style="vertical-align:middle" %)Measures the AC voltage between L1C &L2C.
21 21  |(% style="vertical-align:middle; width:163px" %)Servo drive fault|(% style="vertical-align:middle" %)Contact the agent or customer service
22 -|(% style="vertical-align:middle; width:213px" %)Panel display “Er.xx”|(% colspan="2" style="vertical-align:middle; width:1118px" %)Refer to [[10.2 Handling of faults and warnings during operation>>https://docs.we-con.com.cn/bin/view/Servo/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/10%20Malfunctions/#HFaultsandwarningshandlingduringoperation]]
22 +|(% style="vertical-align:middle; width:213px" %)Panel display “Er.xx”|(% colspan="2" style="vertical-align:middle; width:1118px" %)Refer to [[10.2 Handling of faults and warnings during operation>>||anchor="HFaultsandwarningshandlingduringoperation"]]
23 23  |(% colspan="3" style="vertical-align:middle" %)After removing the fault, the servo drive panel should display "rdy"
24 24  |(% rowspan="4" style="vertical-align:middle" %)Servo drive enable signal is valid(S-ON is ON)|(% rowspan="2" style="vertical-align:middle; width:213px" %)The axis of servo motor is in a free running state|(% style="vertical-align:middle; width:163px" %)Servo enable signal is invalid|(% style="vertical-align:middle" %)(((
25 -✎Check whether group P06 is set the servo enable signal (DI function 1: S-ON). If it is, check whether the corresponding DI terminal logic is valid. If it is invalid,please make it valid. Refer to __[[Group P06 DI/DO configuration>>https://docs.we-con.com.cn/bin/view/Servo/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/09%20Parameters/#HGroupP06DI2FDOconfiguration]]__
25 +✎Check whether group P06 is set the servo enable signal (DI function 1: S-ON). If it is, check whether the corresponding DI terminal logic is valid. If it is invalid,please make it valid. Refer to __[[Group P06 DI/DO configuration>>https://docs.we-con.com.cn/bin/view/Servo/Manual/02%20VD2%20SA%20Series/09%20Parameters/#HGroupP06DI2FDOconfiguration]]__
26 26  
27 -✎If group P06 parameters have set the servo enable signal, and the corresponding terminal logic is valid, but the panel still displays "rdy", check whether the DI terminal wiring is correct, please refer to__[[ 4 Wiring>>https://docs.we-con.com.cn/bin/view/Servo/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/04%20Wiring/]]__
27 +✎If group P06 parameters have set the servo enable signal, and the corresponding terminal logic is valid, but the panel still displays "rdy", check whether the DI terminal wiring is correct, please refer to__[[ 4 Wiring>>doc:Servo.Manual.02 VD2 SA Series.04 Wiring.WebHome]]__
28 28  )))
29 29  |(% style="vertical-align:middle; width:163px" %)Control mode error|(% style="vertical-align:middle" %)Check whether the parameter P00-01 is set correctly
30 -|(% style="vertical-align:middle; width:213px" %)Panel display Er.xx|(% colspan="2" style="vertical-align:middle; width:1118px" %)Refer to [[10.2 Handling of faults and warnings during operation>>https://docs.we-con.com.cn/bin/view/Servo/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/10%20Malfunctions/#HFaultsandwarningshandlingduringoperation]]
30 +|(% style="vertical-align:middle; width:213px" %)Panel display Er.xx|(% colspan="2" style="vertical-align:middle; width:1118px" %)Refer to [[10.2 Handling of faults and warnings during operation>>||anchor="HFaultsandwarningshandlingduringoperation"]]
31 31  |(% colspan="3" style="vertical-align:middle" %)After troubleshooting, the servo drive panel should display "run"
32 32  |(% rowspan="2" style="vertical-align:middle" %)Input position instruction|(% style="vertical-align:middle; width:213px" %)The motor does not rotate|(% style="vertical-align:middle; width:163px" %)U0-09 (input instruction pulse number) always displays 0|(% style="vertical-align:middle" %)✎Not input position instruction(((
33 33  1. Confirm whether DI terminal uses forward drive prohibited (DI function 3: POT) or reverse drive prohibited (DI function 4: NOT).
34 34  1. Confirm whether DI terminal uses instruction pulse input prohibited (DI function 11: INH)
35 35  1. When P01-06=0(position instruction source), PLC or other pulse output device do not output pulse. Please use oscilloscope to check whether there is pulse input or check U0-08 (input instruction pulse frequency). Refer to __4 Wiring__
36 -1. When P01-06=1(position instruction source), please check whether the parameters of group P07 are set correctly. If yes, please confirm whether the DI function 20 (internal multi-segment position enable signal) and the corresponding DI terminal logic are set to be valid. Refer to __[[Group P07 multi-segment position>>https://docs.we-con.com.cn/bin/view/Servo/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/09%20Parameters/#HGroupP07multi-segmentposition]]__
36 +1. When P01-06=1(position instruction source), please check whether the parameters of group P07 are set correctly. If yes, please confirm whether the DI function 20 (internal multi-segment position enable signal) and the corresponding DI terminal logic are set to be valid. Refer to __[[Group P07 multi-segment position>>https://docs.we-con.com.cn/bin/view/Servo/Manual/02%20VD2%20SA%20Series/09%20Parameters/#HGroupP07multi-segmentposition]]__
37 37  )))
38 38  |(% colspan="3" style="vertical-align:middle" %)After troubleshooting, the servo motor should be able to rotate normally
39 39  |(% rowspan="3" style="vertical-align:middle" %)The motor does not rotate smoothly at low speed|(% style="vertical-align:middle; width:213px" %)Unstable low speed|(% style="vertical-align:middle; width:163px" %)Unreasonable gain setting|(% style="vertical-align:middle" %)Please adjust the gain.
... ... @@ -66,20 +66,20 @@
66 66  )))
67 67  |Control the supply voltage failure|Measures the AC voltage between L1C &L2C.
68 68  |Servo drive fault|Contact the agent or customer service
69 -|(% style="vertical-align:middle" %)Panel display “Er.xx”|(% colspan="2" %)Refer to [[10.2 Handling of faults and warnings during operation>>https://docs.we-con.com.cn/bin/view/Servo/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/10%20Malfunctions/#HFaultsandwarningshandlingduringoperation]]
69 +|(% style="vertical-align:middle" %)Panel display “Er.xx”|(% colspan="2" %)Refer to [[10.2 Handling of faults and warnings during operation>>||anchor="HFaultsandwarningshandlingduringoperation"]]
70 70  |(% colspan="3" style="vertical-align:middle" %)After removing the fault, the servo drive panel should display "rdy"
71 71  |(% rowspan="4" style="vertical-align:middle" %)Servo drive enable signal is valid(S-ON is ON)|(% rowspan="2" style="vertical-align:middle" %)The axis of servo motor is in a free running state|Servo enable signal is invalid|(((
72 -✎Check whether group P06 is set the servo enable signal (DI function 1: S-ON). If it is, check whether the corresponding DI terminal logic is valid. If it is invalid,please make it valid. Refer to __[[Group P06 DI/DO configuration>>https://docs.we-con.com.cn/bin/view/Servo/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/09%20Parameters/#HGroupP06DI2FDOconfiguration]]__
72 +✎Check whether group P06 is set the servo enable signal (DI function 1: S-ON). If it is, check whether the corresponding DI terminal logic is valid. If it is invalid,please make it valid. Refer to __[[Group P06 DI/DO configuration>>https://docs.we-con.com.cn/bin/view/Servo/Manual/02%20VD2%20SA%20Series/09%20Parameters/#HGroupP06DI2FDOconfiguration]]__
73 73  
74 -✎If group P06 parameters have set the servo enable signal, and the corresponding terminal logic is valid, but the panel still displays "rdy", check whether the DI terminal wiring is correct, please refer to__[[ 4 Wiring>>https://docs.we-con.com.cn/bin/view/Servo/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/04%20Wiring/]]__
74 +✎If group P06 parameters have set the servo enable signal, and the corresponding terminal logic is valid, but the panel still displays "rdy", check whether the DI terminal wiring is correct, please refer to__[[ 4 Wiring>>doc:Servo.Manual.02 VD2 SA Series.04 Wiring.WebHome]]__
75 75  )))
76 76  |Control mode error|Check whether the parameter P00-01 is set correctly
77 -|(% style="vertical-align:middle" %)Panel display Er.xx|(% colspan="2" %)Refer to [[10.2 Handling of faults and warnings during operation>>https://docs.we-con.com.cn/bin/view/Servo/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/10%20Malfunctions/#HFaultsandwarningshandlingduringoperation]]
77 +|(% style="vertical-align:middle" %)Panel display Er.xx|(% colspan="2" %)Refer to [[10.2 Handling of faults and warnings during operation>>||anchor="HFaultsandwarningshandlingduringoperation"]]
78 78  |(% colspan="3" style="vertical-align:middle" %)After troubleshooting, the servo drive panel should display "run"
79 79  |(% rowspan="2" style="vertical-align:middle" %)Input torque instruction|(% style="vertical-align:middle" %)The motor does not rotate|U0-03 (input instruction pulse number) always displays 0|(((
80 80  ✎AI wiring error
81 81  
82 -When selecting analog input signal, make sure that the connection of analog input terminal is correct. Refer to__[[ 4 Wiring>>https://docs.we-con.com.cn/bin/view/Servo/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/04%20Wiring/]]__.
82 +When selecting analog input signal, make sure that the connection of analog input terminal is correct. Refer to__[[ 4 Wiring>>doc:Servo.Manual.02 VD2 SA Series.04 Wiring.WebHome]]__.
83 83  
84 84  ✎Not input speed instruction or speed instruction abnormal
85 85  
... ... @@ -114,20 +114,20 @@
114 114  )))
115 115  |(% style="vertical-align:middle" %)Control the supply voltage failure|(% style="vertical-align:middle" %)Measures the AC voltage between L1C &L2C.
116 116  |(% style="vertical-align:middle" %)Servo drive fault|(% style="vertical-align:middle" %)Contact the agent or customer service
117 -|(% style="vertical-align:middle" %)Panel display “Er.xx”|(% colspan="2" style="vertical-align:middle" %)Refer to [[10.2 Handling of faults and warnings during operation>>https://docs.we-con.com.cn/bin/view/Servo/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/10%20Malfunctions/#HFaultsandwarningshandlingduringoperation]]
117 +|(% style="vertical-align:middle" %)Panel display “Er.xx”|(% colspan="2" style="vertical-align:middle" %)Refer to [[10.2 Handling of faults and warnings during operation>>||anchor="HFaultsandwarningshandlingduringoperation"]]
118 118  |(% colspan="3" style="vertical-align:middle" %)After removing the fault, the servo drive panel should display "rdy"
119 119  |(% rowspan="4" style="vertical-align:middle" %)Servo drive enable signal is valid(S-ON is ON)|(% rowspan="2" style="vertical-align:middle" %)The axis of servo motor is in a free running state|(% style="vertical-align:middle" %)Servo enable signal is invalid|(% style="vertical-align:middle" %)(((
120 -✎Check whether group P06 is set the servo enable signal (DI function 1: S-ON). If it is, check whether the corresponding DI terminal logic is valid. If it is invalid,please make it valid. Refer to __[[Group P06 DI/DO configuration>>https://docs.we-con.com.cn/bin/view/Servo/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/09%20Parameters/#HGroupP06DI2FDOconfiguration]]__
120 +✎Check whether group P06 is set the servo enable signal (DI function 1: S-ON). If it is, check whether the corresponding DI terminal logic is valid. If it is invalid,please make it valid. Refer to __[[Group P06 DI/DO configuration>>https://docs.we-con.com.cn/bin/view/Servo/Manual/02%20VD2%20SA%20Series/09%20Parameters/#HGroupP06DI2FDOconfiguration]]__
121 121  
122 -✎If group P06 parameters have set the servo enable signal, and the corresponding terminal logic is valid, but the panel still displays "rdy", check whether the DI terminal wiring is correct, please refer to__[[ 4 Wiring>>https://docs.we-con.com.cn/bin/view/Servo/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/04%20Wiring/]]__
122 +✎If group P06 parameters have set the servo enable signal, and the corresponding terminal logic is valid, but the panel still displays "rdy", check whether the DI terminal wiring is correct, please refer to__[[ 4 Wiring>>doc:Servo.Manual.02 VD2 SA Series.04 Wiring.WebHome]]__
123 123  )))
124 124  |(% style="vertical-align:middle" %)Control mode error|(% style="vertical-align:middle" %)Check whether the parameter P00-01 is set correctly
125 -|(% style="vertical-align:middle" %)Panel display Er.xx|(% colspan="2" style="vertical-align:middle" %)Refer to [[10.2 Handling of faults and warnings during operation>>https://docs.we-con.com.cn/bin/view/Servo/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/10%20Malfunctions/#HFaultsandwarningshandlingduringoperation]]
125 +|(% style="vertical-align:middle" %)Panel display Er.xx|(% colspan="2" style="vertical-align:middle" %)Refer to [[10.2 Handling of faults and warnings during operation>>||anchor="HFaultsandwarningshandlingduringoperation"]]
126 126  |(% colspan="3" style="vertical-align:middle" %)After troubleshooting, the servo drive panel should display "run"
127 127  |(% rowspan="2" style="vertical-align:middle" %)Input speed instruction|(% style="vertical-align:middle" %)The motor does not rotate|(% style="vertical-align:middle" %)U0-03 (input instruction pulse number) always displays 0|(% style="vertical-align:middle" %)(((
128 128  ✎AI wiring error
129 129  
130 -When selecting analog input signal, make sure that the connection of analog input terminal is correct. Refer to__[[ 4 Wiring>>https://docs.we-con.com.cn/bin/view/Servo/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/04%20Wiring/]]__.
130 +When selecting analog input signal, make sure that the connection of analog input terminal is correct. Refer to__[[ 4 Wiring>>doc:Servo.Manual.02 VD2 SA Series.04 Wiring.WebHome]]__.
131 131  
132 132  ✎Not input torque instruction
133 133  
... ... @@ -194,7 +194,7 @@
194 194  
195 195  VD2 series servo drives have a fault recording function, which could record the last 5 faults and the last 5 warning names and the status parameters of servo drive when the fault or warning occurs. After the fault or warning is cleared, the fault record will still save the fault and warning.
196 196  
197 -The current fault code could be viewed through the monitoring parameter U1-01, and the current warning code could be viewed through U1-02. The monitoring U1-16 to U1-25 could display the last 5 fault codes and warning codes. Please refer to __[[Group U1 Warning monitoring>>https://docs.we-con.com.cn/bin/view/Servo/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/09%20Parameters/#HGroupU1Warningmonitoring]]__.
197 +The current fault code could be viewed through the monitoring parameter U1-01, and the current warning code could be viewed through U1-02. The monitoring U1-16 to U1-25 could display the last 5 fault codes and warning codes. Please refer to __[[Group U1 Warning monitoring>>https://docs.we-con.com.cn/bin/view/Servo/Manual/02%20VD2%20SA%20Series/09%20Parameters/#HGroupU1Warningmonitoring]]__.
198 198  
199 199  == **Fault and warning code table** ==
200 200  
... ... @@ -571,7 +571,7 @@
571 571  Fault
572 572  
573 573  |=**Servo drive panel display**|=**Fault name**
574 -|[[image:image-20220709165622-15.png]]|Braking resistor resistance is too large
574 +|[[image:image-20220709165622-15.png]]|Motor code wrong
575 575  
576 576  Troubleshooting
577 577  
... ... @@ -852,6 +852,23 @@
852 852  |(% style="width:426px" %)Check whether there are sources of interference such as power supply inverter equipment nearby|(% style="width:404px" %)Separate strong and weak power as much as possible, with good ground contact between motor and servo drive, and keep away from power cable wiring.
853 853  |Servo drive fault|(% style="width:426px" %)The servo drive is still faulty after power on again|(% style="width:404px" %)Servo drive may be damaged, please contact technician for repair.
854 854  
855 +**Er.43 Drive overload fault**
856 +
857 +Fault
858 +
859 +
860 +|=**Servo drive panel display**|=**Fault name**
861 +|[[image:file:///C:/Users/16127/AppData/Local/Temp/msohtmlclip1/01/clip_image001.emz]][[image:file:///C:/Users/16127/AppData/Local/Temp/msohtmlclip1/01/clip_image001.emz]] ​​​​​​[[image:企业微信截图_16877625944107.png]]|Drive overload fault
862 +
863 +Troubleshooting
864 +
865 +|Reason|Troubleshooting|Handling
866 +|The average output power (U0-34) exceeds the limit power (overload 110%) for more than 20 minutes.|Whether the average output power (U0-34) often exceeds the limit (overload 110) Check whether the drive meets the requirements.|Observed whether the U0-34 is often greater than the servo limit power (overload 110%) during servo operation. When ER.43 alarm is found in the process of machine adjustment, please check whether the servo power is suitable. It is recommended to replace the driver model with higher power.
867 +|Servo drive fault|The servo drive is still faulty after power on again|Servo drive may be damaged, contact the manufacturer's technician for repair.
868 +
869 +(% style="text-align:center" %)
870 +[[image:1687762670698-912.png]]
871 +
855 855  **Er.60 ADC conversion is not complete**
856 856  
857 857  Fault
... ... @@ -926,6 +926,25 @@
926 926  |=(% style="width: 212px;" %)**Reason**|=(% style="width: 518px;" %)**Troubleshooting methods**|=(% style="width: 346px;" %)**Handling**
927 927  |(% style="width:212px" %)Servo drive fault|(% style="width:518px" %)Factory reset the parameter (P10-02=1) and power on again. If the servo drive still alarms after multiple operations, it is faulty.|(% style="width:346px" %)If there is still alarm after multiple power-on, contact the technician.
928 928  
946 +**A-80 Drive overpower warning**
947 +
948 +Fault
949 +
950 +|=Servo drive panel display|=Alarm name
951 +|[[image:file:///C:/Users/16127/AppData/Local/Temp/msohtmlclip1/01/clip_image001.emz]][[image:1687763210466-195.png||height="54" width="150"]]|Drive overpower warning
952 +
953 +Troubleshooting
954 +
955 +|Reason|Troubleshooting|Handling
956 +|(((
957 +The average output power (U0-34) exceeds the limit power of the drive (overload 110%) for more than 5 seconds, the drive will have alarm.
958 +
959 +
960 +)))|Check whether the average output power (U0-34) exceeds the limit (overload 110) The average output power (U0-34) exceeds the limit power (overload 110%) for more than 5 minutes. Check whether the U0-34 exceeds 110% of the rated power of the driver.|Check whether the U0-34 exceeds 110% of the rated power of the driver. When A80 alarm is found in the process of machine adjustment, please check whether the servo power is suitable.
961 +
962 +(% style="text-align:center" %)
963 +[[image:1687763249516-252.png]]
964 +
929 929  **A-81 Overspeed alarm**
930 930  
931 931  Fault
... ... @@ -1093,13 +1093,38 @@
1093 1093  Fault
1094 1094  
1095 1095  |=(% style="width: 465px;" %)**Servo drive panel display**|=(% style="width: 610px;" %)**Fault name**
1096 -|(% style="width:465px" %)[[image:image-20220709171241-17.png]]|(% style="width:610px" %)Parameter modification is too frequent
1132 +|(% style="width:465px" %)[[image:image-20220709171241-17.png]]|(% style="width:610px" %)(((
1133 +Parameter modification is too frequent (modification frequency allowed of function code: 6 hours/150 times
1097 1097  
1135 + Note: 32-bit function code: recorded as 2 times)
1136 +)))
1137 +
1098 1098  Troubleshooting
1099 1099  
1100 -|=(% style="width: 232px;" %)**Reason**|=(% style="width: 459px;" %)**Troubleshooting methods**|=(% style="width: 385px;" %)**Handling**
1101 -|(% style="width:232px" %)Parameter modification is too frequent|(% style="width:459px" %)Check whether the host computer frequently modifies the write parameters|(% style="width:385px" %)Ensuring mechanical operation, reduce the frequency of modifying the write parameters of the host computer
1140 +|Reason|Troubleshooting|Handling
1141 +|EEPROM writing frequency is too high|(((
1142 +Check whether the host computer frequently modifies the parameters (modification frequency allowed of function code: 6 hours/150 times
1102 1102  
1144 +Note: 32-bit function code: recorded as 2 times)
1145 +
1146 +
1147 +)))|(((
1148 +(1) During machine adjustment, A91 warning (6 hours/150 times) caused by manual frequent modification of function codes can be cleared through P10-03. In other cases, please check the PLC program
1149 +
1150 +(2) If A91 warning appears in the normal working mode of the machine, please check whether the PLC program frequently modifies the function code.
1151 +
1152 +(3) When the function code needs to be modified frequently, it is recommended to close Modbus write to EEPROM (P12-4 is set to 0)
1153 +)))
1154 +|(% rowspan="3" %)external interference|Check for strong magnetic fields nearby|Eliminate nearby strong magnetic interference
1155 +|Check whether there are sources of interference such as power supply inverter equipment nearby|Separate strong and weak power as much as possible, with good ground contact between motor and servo drive, and keep away from power cable wiring.
1156 +|(((
1157 +Increase the abnormal threshold setting of P0-31 encoder read-write check.
1158 +
1159 +
1160 +)))|Eliminate the A93 warning by increasing the exception threshold is suitable as a temporary solution. The disadvantage is that the motor may run in an unstable state.
1161 +|Encoder fault|Manually rotate the motor shaft counterclockwise or clockwise to observe whether the monitoring quantity U0-30 (electrical angle) changes regularly|If the value of U0-30 (electrical angle) changes abruptly or does not change, the encoder itself may have problems, please replace the motor or encoder.
1162 +|Servo drive fault|●Cross-verification. Use the normal motor, encoder cable to connect to the servo drive. If the servo drive still have alarm, it is servo fault.|Servo driver may be damaged, please contact the manufacturer's technician.
1163 +
1103 1103  **A-92 Low encoder battery voltage warning**
1104 1104  
1105 1105  Fault
... ... @@ -1117,11 +1117,13 @@
1117 1117  Fault
1118 1118  
1119 1119  |=(% style="width: 378px;" %)**Servo drive panel display**|=(% style="width: 697px;" %)**Fault name**
1120 -|(% style="width:378px" %)[[image:image-20220709171304-19.png]]|(% style="width:697px" %)Abnormal and frequency of encoder read and write check is too high
1181 +|(% style="width:378px" %)[[image:image-20220709171304-19.png]]|(% style="width:697px" %)The abnormal frequency of encoder read-write verification is too high
1121 1121  
1122 1122  Troubleshooting
1123 1123  
1124 1124  |=(% style="width: 235px;" %)**Reason**|=(% style="width: 446px;" %)**Troubleshooting methods**|=(% style="width: 395px;" %)**Handling**
1125 -|(% rowspan="2" style="width:235px" %)External interference|(% style="width:446px" %)Check for strong magnetic fields nearby|(% style="width:395px" %)Eliminate nearby strong magnetic interference
1186 +|(% colspan="1" rowspan="3" style="width:235px" %)External interference|(% style="width:446px" %)Check for strong magnetic fields nearby|(% style="width:395px" %)Eliminate nearby strong magnetic interference
1126 1126  |(% style="width:446px" %)Check whether there are sources of interference such as power supply inverter equipment nearby|(% style="width:395px" %)Separate strong and weak power as much as possible, with good ground contact between motor and servo drive, and keep away from power cable wiring.
1188 +|(% style="width:446px" %)Increase the abnormal threshold setting of P0-31.|(% style="width:395px" %)This method is suitable as a temporary workaround to eliminate the A93 warning. It may cause an unstable state in the operation of the motor.
1189 +|(% style="width:235px" %)Encoder issue|(% style="width:446px" %)Manually rotate the motor shaft slowly, and observe the changes of the monitoring quantity U0-30 (electrical angle).|(% style="width:395px" %)If the value of U0-30 (electrical angle) changes suddenly or does not change, it may be a problem with the encoder, please replace the motor or encoder.
1127 1127  |(% style="width:235px" %)Internal servo drive fault|(% style="width:446px" %)Cross-verification. Use the normal motor, encoder cable to connect to the servo drive, only connect the encoder cable. If the servo drive still alarm, it is failure.|(% style="width:395px" %)Contact technician for repair
1687762670698-912.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Jim
Size
... ... @@ -1,0 +1,1 @@
1 +99.7 KB
Content
1687763210466-195.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Jim
Size
... ... @@ -1,0 +1,1 @@
1 +7.1 KB
Content
1687763249516-252.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Jim
Size
... ... @@ -1,0 +1,1 @@
1 +104.1 KB
Content
企业微信截图_16877625944107.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Jim
Size
... ... @@ -1,0 +1,1 @@
1 +2.9 KB
Content