Changes for page 10 Malfunctions
Last modified by Theodore Xu on 2025/02/13 17:16
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 5 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Stone1 +XWiki.Mora - Content
-
... ... @@ -19,21 +19,21 @@ 19 19 ))) 20 20 |(% style="vertical-align:middle; width:163px" %)Control the supply voltage failure|(% style="vertical-align:middle" %)Measures the AC voltage between L1C &L2C. 21 21 |(% style="vertical-align:middle; width:163px" %)Servo drive fault|(% style="vertical-align:middle" %)Contact the agent or customer service 22 -|(% style="vertical-align:middle; width:213px" %)Panel display “Er.xx”|(% colspan="2" style="vertical-align:middle; width:1118px" %)Refer to [[10.2 Handling of faults and warnings during operation>> https://docs.we-con.com.cn/bin/view/Servo/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/10%20Malfunctions/#HFaultsandwarningshandlingduringoperation]]22 +|(% style="vertical-align:middle; width:213px" %)Panel display “Er.xx”|(% colspan="2" style="vertical-align:middle; width:1118px" %)Refer to [[10.2 Handling of faults and warnings during operation>>||anchor="HFaultsandwarningshandlingduringoperation"]] 23 23 |(% colspan="3" style="vertical-align:middle" %)After removing the fault, the servo drive panel should display "rdy" 24 24 |(% rowspan="4" style="vertical-align:middle" %)Servo drive enable signal is valid(S-ON is ON)|(% rowspan="2" style="vertical-align:middle; width:213px" %)The axis of servo motor is in a free running state|(% style="vertical-align:middle; width:163px" %)Servo enable signal is invalid|(% style="vertical-align:middle" %)((( 25 -✎Check whether group P06 is set the servo enable signal (DI function 1: S-ON). If it is, check whether the corresponding DI terminal logic is valid. If it is invalid,please make it valid. Refer to __[[Group P06 DI/DO configuration>>https://docs.we-con.com.cn/bin/view/Servo/ 2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/09%20Parameters/#HGroupP06DI2FDOconfiguration]]__25 +✎Check whether group P06 is set the servo enable signal (DI function 1: S-ON). If it is, check whether the corresponding DI terminal logic is valid. If it is invalid,please make it valid. Refer to __[[Group P06 DI/DO configuration>>https://docs.we-con.com.cn/bin/view/Servo/Manual/02%20VD2%20SA%20Series/09%20Parameters/#HGroupP06DI2FDOconfiguration]]__ 26 26 27 -✎If group P06 parameters have set the servo enable signal, and the corresponding terminal logic is valid, but the panel still displays "rdy", check whether the DI terminal wiring is correct, please refer to__[[ 4 Wiring>> https://docs.we-con.com.cn/bin/view/Servo/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/04%20Wiring/]]__27 +✎If group P06 parameters have set the servo enable signal, and the corresponding terminal logic is valid, but the panel still displays "rdy", check whether the DI terminal wiring is correct, please refer to__[[ 4 Wiring>>doc:Servo.Manual.02 VD2 SA Series.04 Wiring.WebHome]]__ 28 28 ))) 29 29 |(% style="vertical-align:middle; width:163px" %)Control mode error|(% style="vertical-align:middle" %)Check whether the parameter P00-01 is set correctly 30 -|(% style="vertical-align:middle; width:213px" %)Panel display Er.xx|(% colspan="2" style="vertical-align:middle; width:1118px" %)Refer to [[10.2 Handling of faults and warnings during operation>> https://docs.we-con.com.cn/bin/view/Servo/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/10%20Malfunctions/#HFaultsandwarningshandlingduringoperation]]30 +|(% style="vertical-align:middle; width:213px" %)Panel display Er.xx|(% colspan="2" style="vertical-align:middle; width:1118px" %)Refer to [[10.2 Handling of faults and warnings during operation>>||anchor="HFaultsandwarningshandlingduringoperation"]] 31 31 |(% colspan="3" style="vertical-align:middle" %)After troubleshooting, the servo drive panel should display "run" 32 32 |(% rowspan="2" style="vertical-align:middle" %)Input position instruction|(% style="vertical-align:middle; width:213px" %)The motor does not rotate|(% style="vertical-align:middle; width:163px" %)U0-09 (input instruction pulse number) always displays 0|(% style="vertical-align:middle" %)✎Not input position instruction((( 33 33 1. Confirm whether DI terminal uses forward drive prohibited (DI function 3: POT) or reverse drive prohibited (DI function 4: NOT). 34 34 1. Confirm whether DI terminal uses instruction pulse input prohibited (DI function 11: INH) 35 35 1. When P01-06=0(position instruction source), PLC or other pulse output device do not output pulse. Please use oscilloscope to check whether there is pulse input or check U0-08 (input instruction pulse frequency). Refer to __4 Wiring__ 36 -1. When P01-06=1(position instruction source), please check whether the parameters of group P07 are set correctly. If yes, please confirm whether the DI function 20 (internal multi-segment position enable signal) and the corresponding DI terminal logic are set to be valid. Refer to __[[Group P07 multi-segment position>>https://docs.we-con.com.cn/bin/view/Servo/ 2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/09%20Parameters/#HGroupP07multi-segmentposition]]__36 +1. When P01-06=1(position instruction source), please check whether the parameters of group P07 are set correctly. If yes, please confirm whether the DI function 20 (internal multi-segment position enable signal) and the corresponding DI terminal logic are set to be valid. Refer to __[[Group P07 multi-segment position>>https://docs.we-con.com.cn/bin/view/Servo/Manual/02%20VD2%20SA%20Series/09%20Parameters/#HGroupP07multi-segmentposition]]__ 37 37 ))) 38 38 |(% colspan="3" style="vertical-align:middle" %)After troubleshooting, the servo motor should be able to rotate normally 39 39 |(% rowspan="3" style="vertical-align:middle" %)The motor does not rotate smoothly at low speed|(% style="vertical-align:middle; width:213px" %)Unstable low speed|(% style="vertical-align:middle; width:163px" %)Unreasonable gain setting|(% style="vertical-align:middle" %)Please adjust the gain. ... ... @@ -66,20 +66,20 @@ 66 66 ))) 67 67 |Control the supply voltage failure|Measures the AC voltage between L1C &L2C. 68 68 |Servo drive fault|Contact the agent or customer service 69 -|(% style="vertical-align:middle" %)Panel display “Er.xx”|(% colspan="2" %)Refer to [[10.2 Handling of faults and warnings during operation>> https://docs.we-con.com.cn/bin/view/Servo/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/10%20Malfunctions/#HFaultsandwarningshandlingduringoperation]]69 +|(% style="vertical-align:middle" %)Panel display “Er.xx”|(% colspan="2" %)Refer to [[10.2 Handling of faults and warnings during operation>>||anchor="HFaultsandwarningshandlingduringoperation"]] 70 70 |(% colspan="3" style="vertical-align:middle" %)After removing the fault, the servo drive panel should display "rdy" 71 71 |(% rowspan="4" style="vertical-align:middle" %)Servo drive enable signal is valid(S-ON is ON)|(% rowspan="2" style="vertical-align:middle" %)The axis of servo motor is in a free running state|Servo enable signal is invalid|((( 72 -✎Check whether group P06 is set the servo enable signal (DI function 1: S-ON). If it is, check whether the corresponding DI terminal logic is valid. If it is invalid,please make it valid. Refer to __[[Group P06 DI/DO configuration>>https://docs.we-con.com.cn/bin/view/Servo/ 2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/09%20Parameters/#HGroupP06DI2FDOconfiguration]]__72 +✎Check whether group P06 is set the servo enable signal (DI function 1: S-ON). If it is, check whether the corresponding DI terminal logic is valid. If it is invalid,please make it valid. Refer to __[[Group P06 DI/DO configuration>>https://docs.we-con.com.cn/bin/view/Servo/Manual/02%20VD2%20SA%20Series/09%20Parameters/#HGroupP06DI2FDOconfiguration]]__ 73 73 74 -✎If group P06 parameters have set the servo enable signal, and the corresponding terminal logic is valid, but the panel still displays "rdy", check whether the DI terminal wiring is correct, please refer to__[[ 4 Wiring>> https://docs.we-con.com.cn/bin/view/Servo/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/04%20Wiring/]]__74 +✎If group P06 parameters have set the servo enable signal, and the corresponding terminal logic is valid, but the panel still displays "rdy", check whether the DI terminal wiring is correct, please refer to__[[ 4 Wiring>>doc:Servo.Manual.02 VD2 SA Series.04 Wiring.WebHome]]__ 75 75 ))) 76 76 |Control mode error|Check whether the parameter P00-01 is set correctly 77 -|(% style="vertical-align:middle" %)Panel display Er.xx|(% colspan="2" %)Refer to [[10.2 Handling of faults and warnings during operation>> https://docs.we-con.com.cn/bin/view/Servo/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/10%20Malfunctions/#HFaultsandwarningshandlingduringoperation]]77 +|(% style="vertical-align:middle" %)Panel display Er.xx|(% colspan="2" %)Refer to [[10.2 Handling of faults and warnings during operation>>||anchor="HFaultsandwarningshandlingduringoperation"]] 78 78 |(% colspan="3" style="vertical-align:middle" %)After troubleshooting, the servo drive panel should display "run" 79 79 |(% rowspan="2" style="vertical-align:middle" %)Input torque instruction|(% style="vertical-align:middle" %)The motor does not rotate|U0-03 (input instruction pulse number) always displays 0|((( 80 80 ✎AI wiring error 81 81 82 -When selecting analog input signal, make sure that the connection of analog input terminal is correct. Refer to__[[ 4 Wiring>> https://docs.we-con.com.cn/bin/view/Servo/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/04%20Wiring/]]__.82 +When selecting analog input signal, make sure that the connection of analog input terminal is correct. Refer to__[[ 4 Wiring>>doc:Servo.Manual.02 VD2 SA Series.04 Wiring.WebHome]]__. 83 83 84 84 ✎Not input speed instruction or speed instruction abnormal 85 85 ... ... @@ -114,20 +114,20 @@ 114 114 ))) 115 115 |(% style="vertical-align:middle" %)Control the supply voltage failure|(% style="vertical-align:middle" %)Measures the AC voltage between L1C &L2C. 116 116 |(% style="vertical-align:middle" %)Servo drive fault|(% style="vertical-align:middle" %)Contact the agent or customer service 117 -|(% style="vertical-align:middle" %)Panel display “Er.xx”|(% colspan="2" style="vertical-align:middle" %)Refer to [[10.2 Handling of faults and warnings during operation>> https://docs.we-con.com.cn/bin/view/Servo/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/10%20Malfunctions/#HFaultsandwarningshandlingduringoperation]]117 +|(% style="vertical-align:middle" %)Panel display “Er.xx”|(% colspan="2" style="vertical-align:middle" %)Refer to [[10.2 Handling of faults and warnings during operation>>||anchor="HFaultsandwarningshandlingduringoperation"]] 118 118 |(% colspan="3" style="vertical-align:middle" %)After removing the fault, the servo drive panel should display "rdy" 119 119 |(% rowspan="4" style="vertical-align:middle" %)Servo drive enable signal is valid(S-ON is ON)|(% rowspan="2" style="vertical-align:middle" %)The axis of servo motor is in a free running state|(% style="vertical-align:middle" %)Servo enable signal is invalid|(% style="vertical-align:middle" %)((( 120 -✎Check whether group P06 is set the servo enable signal (DI function 1: S-ON). If it is, check whether the corresponding DI terminal logic is valid. If it is invalid,please make it valid. Refer to __[[Group P06 DI/DO configuration>>https://docs.we-con.com.cn/bin/view/Servo/ 2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/09%20Parameters/#HGroupP06DI2FDOconfiguration]]__120 +✎Check whether group P06 is set the servo enable signal (DI function 1: S-ON). If it is, check whether the corresponding DI terminal logic is valid. If it is invalid,please make it valid. Refer to __[[Group P06 DI/DO configuration>>https://docs.we-con.com.cn/bin/view/Servo/Manual/02%20VD2%20SA%20Series/09%20Parameters/#HGroupP06DI2FDOconfiguration]]__ 121 121 122 -✎If group P06 parameters have set the servo enable signal, and the corresponding terminal logic is valid, but the panel still displays "rdy", check whether the DI terminal wiring is correct, please refer to__[[ 4 Wiring>> https://docs.we-con.com.cn/bin/view/Servo/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/04%20Wiring/]]__122 +✎If group P06 parameters have set the servo enable signal, and the corresponding terminal logic is valid, but the panel still displays "rdy", check whether the DI terminal wiring is correct, please refer to__[[ 4 Wiring>>doc:Servo.Manual.02 VD2 SA Series.04 Wiring.WebHome]]__ 123 123 ))) 124 124 |(% style="vertical-align:middle" %)Control mode error|(% style="vertical-align:middle" %)Check whether the parameter P00-01 is set correctly 125 -|(% style="vertical-align:middle" %)Panel display Er.xx|(% colspan="2" style="vertical-align:middle" %)Refer to [[10.2 Handling of faults and warnings during operation>> https://docs.we-con.com.cn/bin/view/Servo/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/10%20Malfunctions/#HFaultsandwarningshandlingduringoperation]]125 +|(% style="vertical-align:middle" %)Panel display Er.xx|(% colspan="2" style="vertical-align:middle" %)Refer to [[10.2 Handling of faults and warnings during operation>>||anchor="HFaultsandwarningshandlingduringoperation"]] 126 126 |(% colspan="3" style="vertical-align:middle" %)After troubleshooting, the servo drive panel should display "run" 127 127 |(% rowspan="2" style="vertical-align:middle" %)Input speed instruction|(% style="vertical-align:middle" %)The motor does not rotate|(% style="vertical-align:middle" %)U0-03 (input instruction pulse number) always displays 0|(% style="vertical-align:middle" %)((( 128 128 ✎AI wiring error 129 129 130 -When selecting analog input signal, make sure that the connection of analog input terminal is correct. Refer to__[[ 4 Wiring>> https://docs.we-con.com.cn/bin/view/Servo/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/04%20Wiring/]]__.130 +When selecting analog input signal, make sure that the connection of analog input terminal is correct. Refer to__[[ 4 Wiring>>doc:Servo.Manual.02 VD2 SA Series.04 Wiring.WebHome]]__. 131 131 132 132 ✎Not input torque instruction 133 133 ... ... @@ -194,7 +194,7 @@ 194 194 195 195 VD2 series servo drives have a fault recording function, which could record the last 5 faults and the last 5 warning names and the status parameters of servo drive when the fault or warning occurs. After the fault or warning is cleared, the fault record will still save the fault and warning. 196 196 197 -The current fault code could be viewed through the monitoring parameter U1-01, and the current warning code could be viewed through U1-02. The monitoring U1-16 to U1-25 could display the last 5 fault codes and warning codes. Please refer to __[[Group U1 Warning monitoring>>https://docs.we-con.com.cn/bin/view/Servo/ 2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/09%20Parameters/#HGroupU1Warningmonitoring]]__.197 +The current fault code could be viewed through the monitoring parameter U1-01, and the current warning code could be viewed through U1-02. The monitoring U1-16 to U1-25 could display the last 5 fault codes and warning codes. Please refer to __[[Group U1 Warning monitoring>>https://docs.we-con.com.cn/bin/view/Servo/Manual/02%20VD2%20SA%20Series/09%20Parameters/#HGroupU1Warningmonitoring]]__. 198 198 199 199 == **Fault and warning code table** == 200 200 ... ... @@ -304,7 +304,10 @@ 304 304 Fault 305 305 306 306 |=(% style="width: 460px;" %)**Servo drive panel display**|=(% style="width: 615px;" %)**Fault name** 307 -|(% style="width:460px" %)[[image:image-20220709173736-1.png]]|(% style="width:615px" %)Parameter destruction 307 +|(% style="width:460px" %)((( 308 +(% style="text-align:center" %) 309 +[[image:image-20220709173736-1.png]] 310 +)))|(% style="width:615px" %)Parameter destruction 308 308 309 309 Troubleshooting 310 310 ... ... @@ -315,8 +315,11 @@ 315 315 316 316 Fault 317 317 318 -|=(% style="width: 471px;" %)**Servo drive panel display**|=(% style="width: 604px;" %)**Fault name** 319 -|(% style="width:471px" %)[[image:image-20220709165407-2.png]]|(% style="width:604px" %)Parameter storage error 321 +|=(% style="width: 604px;" %)**Servo drive panel display**|=(% style="width: 817px;" %)**Fault name** 322 +|(% style="width:604px" %)((( 323 +(% style="text-align:center" %) 324 +[[image:image-20220709165407-2.png]] 325 +)))|(% style="width:817px" %)Parameter storage error 320 320 321 321 Troubleshooting 322 322 ... ... @@ -340,7 +340,10 @@ 340 340 Fault 341 341 342 342 |=(% style="width: 459px;" %)**Servo drive panel display**|=(% style="width: 617px;" %)**Fault name** 343 -|(% style="width:459px" %)[[image:image-20220709165412-3.png]]|(% style="width:617px" %)ADC reference source fault 349 +|(% style="width:459px" %)((( 350 +(% style="text-align:center" %) 351 +[[image:image-20220709165412-3.png]] 352 +)))|(% style="width:617px" %)ADC reference source fault 344 344 345 345 Troubleshooting 346 346 ... ... @@ -352,7 +352,10 @@ 352 352 Fault 353 353 354 354 |=**Servo drive panel display**|=**Fault name** 355 -|[[image:image-20220709165421-4.png]]|AD current sampling conversion error 364 +|((( 365 +(% style="text-align:center" %) 366 +[[image:image-20220709165421-4.png]] 367 +)))|AD current sampling conversion error 356 356 357 357 Troubleshooting 358 358 ... ... @@ -365,7 +365,10 @@ 365 365 Fault 366 366 367 367 |=(% style="width: 467px;" %)**Servo drive panel display**|=(% style="width: 608px;" %)**Fault name** 368 -|(% style="width:467px" %)[[image:image-20220709165428-5.png]]|(% style="width:608px" %)FPGA communication abnormal 380 +|(% style="width:467px" %)((( 381 +(% style="text-align:center" %) 382 +[[image:image-20220709165428-5.png]] 383 +)))|(% style="width:608px" %)FPGA communication abnormal 369 369 370 370 Troubleshooting 371 371 ... ... @@ -377,7 +377,10 @@ 377 377 Fault 378 378 379 379 |=(% style="width: 460px;" %)**Servo drive panel display**|=(% style="width: 615px;" %)**Fault name** 380 -|(% style="width:460px" %)[[image:image-20220709165434-6.png]]|(% style="width:615px" %)Wrong FPGA program version 395 +|(% style="width:460px" %)((( 396 +(% style="text-align:center" %) 397 +[[image:image-20220709165434-6.png]] 398 +)))|(% style="width:615px" %)Wrong FPGA program version 381 381 382 382 Troubleshooting 383 383 ... ... @@ -400,7 +400,10 @@ 400 400 Fault 401 401 402 402 |=(% style="width: 475px;" %)**Servo drive panel display**|=(% style="width: 600px;" %)**Fault name** 403 -|(% style="width:475px" %)[[image:image-20220709165440-7.png]]|(% style="width:600px" %)Clock abnormal 421 +|(% style="width:475px" %)((( 422 +(% style="text-align:center" %) 423 +[[image:image-20220709165440-7.png]] 424 +)))|(% style="width:600px" %)Clock abnormal 404 404 405 405 Troubleshooting 406 406 ... ... @@ -414,7 +414,10 @@ 414 414 Fault 415 415 416 416 |=(% style="width: 470px;" %)**Servo drive panel display**|=(% style="width: 605px;" %)**Fault name** 417 -|(% style="width:470px" %)[[image:image-20220709165445-8.png]]|(% style="width:605px" %)Overcurrent 438 +|(% style="width:470px" %)((( 439 +(% style="text-align:center" %) 440 +[[image:image-20220709165445-8.png]] 441 +)))|(% style="width:605px" %)Overcurrent 418 418 419 419 Troubleshooting 420 420 ... ... @@ -443,7 +443,10 @@ 443 443 Fault 444 444 445 445 |=(% style="width: 467px;" %)**Servo drive panel display**|=(% style="width: 608px;" %)**Fault name** 446 -|(% style="width:467px" %)[[image:image-20220709165459-10.png]]|(% style="width:608px" %)Main power supply undervoltage 470 +|(% style="width:467px" %)((( 471 +(% style="text-align:center" %) 472 +[[image:image-20220709165459-10.png]] 473 +)))|(% style="width:608px" %)Main power supply undervoltage 447 447 448 448 Reason: DC bus voltage is lower than the fault value. 449 449 ... ... @@ -478,14 +478,17 @@ 478 478 220V drive: U0-31 less than 200V; 479 479 380V drive: U0-31 less than 400V.|(% style="width:355px" %)Contact technician for repair 480 480 481 -**Er.22 Main power supply undervoltage**508 +**Er.22 Main power supply overvoltage** 482 482 483 483 Fault 484 484 485 485 |=(% style="width: 457px;" %)**Servo drive panel display**|=(% style="width: 618px;" %)**Fault name** 486 -|(% style="width:457px" %)[[image:image-20220709165541-11.png]]|(% style="width:618px" %)Main power supply undervoltage 513 +|(% style="width:457px" %)((( 514 +(% style="text-align:center" %) 515 +[[image:image-20220709165541-11.png]] 516 +)))|(% style="width:618px" %)Main power supply overvoltage 487 487 488 -Reason: DC bus voltage is lower than the fault value.518 +Reason: DC bus voltage is bigger than the fault value. 489 489 490 490 1. 220V drive: DC bus voltage normal value is 310V; DC bus voltage fault value is 390V. 491 491 1. 380V drive: DC bus voltage normal value is 540V; DC bus voltage fault value is 670V. ... ... @@ -517,7 +517,10 @@ 517 517 Fault 518 518 519 519 |=(% style="width: 464px;" %)**Servo drive panel display**|=(% style="width: 611px;" %)**Fault name** 520 -|(% style="width:464px" %)[[image:image-20220709165550-12.png]]|(% style="width:611px" %)Braking resistor is not connected 550 +|(% style="width:464px" %)((( 551 +(% style="text-align:center" %) 552 +[[image:image-20220709165550-12.png]] 553 +)))|(% style="width:611px" %)Braking resistor is not connected 521 521 522 522 Troubleshooting 523 523 ... ... @@ -535,7 +535,10 @@ 535 535 Fault 536 536 537 537 |=**Servo drive panel display**|=**Fault name** 538 -|[[image:image-20220709163326-60.png]]|Braking resistor is not connected 571 +|((( 572 +(% style="text-align:center" %) 573 +[[image:image-20220709163326-60.png]] 574 +)))|Braking resistor is not connected 539 539 540 540 Troubleshooting 541 541 ... ... @@ -547,7 +547,10 @@ 547 547 Fault 548 548 549 549 |=**Servo drive panel display**|=**Fault name** 550 -|[[image:image-20220709165610-14.png]]|Braking resistor resistance is too large 586 +|((( 587 +(% style="text-align:center" %) 588 +[[image:image-20220709165610-14.png]] 589 +)))|Braking resistor resistance is too large 551 551 552 552 Troubleshooting 553 553 ... ... @@ -571,7 +571,10 @@ 571 571 Fault 572 572 573 573 |=**Servo drive panel display**|=**Fault name** 574 -|[[image:image-20220709165622-15.png]]|Braking resistor resistance is too large 613 +|((( 614 +(% style="text-align:center" %) 615 +[[image:image-20220709165622-15.png]] 616 +)))|Motor code wrong 575 575 576 576 Troubleshooting 577 577 ... ... @@ -584,7 +584,10 @@ 584 584 Fault 585 585 586 586 |=(% style="width: 466px;" %)**Servo drive panel display**|=(% style="width: 609px;" %)**Fault name** 587 -|(% style="width:466px" %)[[image:image-20220709165628-16.png]]|(% style="width:609px" %)Encoder disconnection 629 +|(% style="width:466px" %)((( 630 +(% style="text-align:center" %) 631 +[[image:image-20220709165628-16.png]] 632 +)))|(% style="width:609px" %)Encoder disconnection 588 588 589 589 Troubleshooting 590 590 ... ... @@ -600,7 +600,10 @@ 600 600 Fault 601 601 602 602 |=(% style="width: 463px;" %)**Servo drive panel display**|=(% style="width: 612px;" %)**Fault name** 603 -|(% style="width:463px" %)[[image:image-20220709165633-17.png]]|(% style="width:612px" %)Encoder Z pulse lost 648 +|(% style="width:463px" %)((( 649 +(% style="text-align:center" %) 650 +[[image:image-20220709165633-17.png]] 651 +)))|(% style="width:612px" %)Encoder Z pulse lost 604 604 605 605 Troubleshooting 606 606 ... ... @@ -615,7 +615,10 @@ 615 615 Fault 616 616 617 617 |=(% style="width: 470px;" %)**Servo drive panel display**|=(% style="width: 605px;" %)**Fault name** 618 -|(% style="width:470px" %)[[image:image-20220709165638-18.png]]|(% style="width:605px" %)Encoder UVW signal error 666 +|(% style="width:470px" %)((( 667 +(% style="text-align:center" %) 668 +[[image:image-20220709165638-18.png]] 669 +)))|(% style="width:605px" %)Encoder UVW signal error 619 619 620 620 Troubleshooting 621 621 ... ... @@ -629,7 +629,10 @@ 629 629 Fault 630 630 631 631 |=(% style="width: 468px;" %)**Servo drive panel display**|=(% style="width: 607px;" %)**Fault name** 632 -|(% style="width:468px" %)[[image:image-20220709165643-19.png]]|(% style="width:607px" %)Power line disconnection 683 +|(% style="width:468px" %)((( 684 +(% style="text-align:center" %) 685 +[[image:image-20220709165643-19.png]] 686 +)))|(% style="width:607px" %)Power line disconnection 633 633 634 634 Troubleshooting 635 635 ... ... @@ -643,7 +643,10 @@ 643 643 Fault 644 644 645 645 |=(% style="width: 465px;" %)**Servo drive panel display**|=(% style="width: 610px;" %)**Fault name** 646 -|(% style="width:465px" %)[[image:image-20220709165647-20.png]]|(% style="width:610px" %)Exceeds motor maximum speed 700 +|(% style="width:465px" %)((( 701 +(% style="text-align:center" %) 702 +[[image:image-20220709165647-20.png]] 703 +)))|(% style="width:610px" %)Exceeds motor maximum speed 647 647 648 648 Troubleshooting 649 649 ... ... @@ -664,7 +664,10 @@ 664 664 Fault 665 665 666 666 |=(% style="width: 468px;" %)**Servo drive panel display**|=(% style="width: 607px;" %)**Fault name** 667 -|(% style="width:468px" %)[[image:image-20220709165654-21.png]]|(% style="width:607px" %)Power module is over temperature 724 +|(% style="width:468px" %)((( 725 +(% style="text-align:center" %) 726 +[[image:image-20220709165654-21.png]] 727 +)))|(% style="width:607px" %)Power module is over temperature 668 668 669 669 Troubleshooting 670 670 ... ... @@ -679,7 +679,10 @@ 679 679 Fault 680 680 681 681 |=(% style="width: 460px;" %)**Servo drive panel display**|=(% style="width: 615px;" %)**Fault name** 682 -|(% style="width:460px" %)[[image:image-20220709170406-1.png]]|(% style="width:615px" %)Motor overload protection 742 +|(% style="width:460px" %)((( 743 +(% style="text-align:center" %) 744 +[[image:image-20220709170406-1.png]] 745 +)))|(% style="width:615px" %)Motor overload protection 683 683 684 684 Troubleshooting 685 685 ... ... @@ -708,7 +708,10 @@ 708 708 Fault 709 709 710 710 |=(% style="width: 473px;" %)**Servo drive panel display**|=(% style="width: 602px;" %)**Fault name** 711 -|(% style="width:473px" %)[[image:image-20220709170424-2.png]]|(% style="width:602px" %)Electronic gear ratio exceeds limit 774 +|(% style="width:473px" %)((( 775 +(% style="text-align:center" %) 776 +[[image:image-20220709170424-2.png]] 777 +)))|(% style="width:602px" %)Electronic gear ratio exceeds limit 712 712 713 713 Troubleshooting 714 714 ... ... @@ -731,7 +731,10 @@ 731 731 Fault 732 732 733 733 |=(% style="width: 463px;" %)**Servo drive panel display**|=(% style="width: 612px;" %)**Fault name** 734 -|(% style="width:463px" %)[[image:image-20220709170438-3.png]]|(% style="width:612px" %)Position deviation is too large 800 +|(% style="width:463px" %)((( 801 +(% style="text-align:center" %) 802 +[[image:image-20220709170438-3.png]] 803 +)))|(% style="width:612px" %)Position deviation is too large 735 735 736 736 Troubleshooting 737 737 ... ... @@ -752,7 +752,10 @@ 752 752 Fault 753 753 754 754 |=(% style="width: 467px;" %)**Servo drive panel display**|=(% style="width: 608px;" %)**Fault name** 755 -|(% style="width:467px" %)[[image:image-20220709170455-4.png]]|(% style="width:608px" %)Torque saturation abnormal 824 +|(% style="width:467px" %)((( 825 +(% style="text-align:center" %) 826 +[[image:image-20220709170455-4.png]] 827 +)))|(% style="width:608px" %)Torque saturation abnormal 756 756 757 757 Troubleshooting 758 758 ... ... @@ -772,7 +772,10 @@ 772 772 Fault 773 773 774 774 |=**Servo drive panel display**|=**Fault name** 775 -|[[image:image-20220709170508-5.png]]|Main circuit electricity is lack of phase 847 +|((( 848 +(% style="text-align:center" %) 849 +[[image:image-20220709170508-5.png]] 850 +)))|Main circuit electricity is lack of phase 776 776 777 777 Troubleshooting 778 778 ... ... @@ -794,7 +794,10 @@ 794 794 Fault 795 795 796 796 |=(% style="width: 466px;" %)**Servo drive panel display**|=(% style="width: 609px;" %)**Fault name** 797 -|(% style="width:466px" %)[[image:image-20220709170521-6.png]]|(% style="width:609px" %)Emergency stop 872 +|(% style="width:466px" %)((( 873 +(% style="text-align:center" %) 874 +[[image:image-20220709170521-6.png]] 875 +)))|(% style="width:609px" %)Emergency stop 798 798 799 799 Troubleshooting 800 800 ... ... @@ -815,7 +815,10 @@ 815 815 Fault 816 816 817 817 |=(% style="width: 469px;" %)**Servo drive panel display**|=(% style="width: 606px;" %)**Fault name** 818 -|(% style="width:469px" %)[[image:image-20220709170534-7.png]]|(% style="width:606px" %)Encoder battery failure 896 +|(% style="width:469px" %)((( 897 +(% style="text-align:center" %) 898 +[[image:image-20220709170534-7.png]] 899 +)))|(% style="width:606px" %)Encoder battery failure 819 819 820 820 Troubleshooting 821 821 ... ... @@ -828,7 +828,10 @@ 828 828 Fault 829 829 830 830 |=(% style="width: 465px;" %)**Servo drive panel display**|=(% style="width: 610px;" %)**Fault name** 831 -|(% style="width:465px" %)[[image:image-20220709170547-8.png]]|(% style="width:610px" %)Motor (encoder) over temperature 912 +|(% style="width:465px" %)((( 913 +(% style="text-align:center" %) 914 +[[image:image-20220709170547-8.png]] 915 +)))|(% style="width:610px" %)Motor (encoder) over temperature 832 832 833 833 Troubleshooting 834 834 ... ... @@ -840,7 +840,10 @@ 840 840 Fault 841 841 842 842 |=(% style="width: 471px;" %)**Servo drive panel display**|=(% style="width: 604px;" %)**Fault name** 843 -|(% style="width:471px" %)[[image:image-20220709170937-1.png]]|(% style="width:604px" %)Encoder write faults 927 +|(% style="width:471px" %)((( 928 +(% style="text-align:center" %) 929 +[[image:image-20220709170937-1.png]] 930 +)))|(% style="width:604px" %)Encoder write faults 844 844 845 845 Troubleshooting 846 846 ... ... @@ -852,12 +852,51 @@ 852 852 |(% style="width:426px" %)Check whether there are sources of interference such as power supply inverter equipment nearby|(% style="width:404px" %)Separate strong and weak power as much as possible, with good ground contact between motor and servo drive, and keep away from power cable wiring. 853 853 |Servo drive fault|(% style="width:426px" %)The servo drive is still faulty after power on again|(% style="width:404px" %)Servo drive may be damaged, please contact technician for repair. 854 854 942 +**Er.43 Drive overload fault** 943 + 944 +Fault 945 + 946 + 947 +|=(% style="width: 794px;" %)**Servo drive panel display**|=(% style="width: 627px;" %)**Fault name** 948 +|(% style="width:794px" %) ((( 949 +(% style="text-align:center" %) 950 +[[image:企业微信截图_16877625944107.png]] 951 +)))|(% style="width:627px" %)Drive overload fault 952 + 953 +Troubleshooting 954 + 955 +|=Reason|=Troubleshooting|=Handling 956 +|The average output power (U0-34) exceeds the limit power (overload 110%) for more than 20 minutes.|Whether the average output power (U0-34) often exceeds the limit (overload 110) Check whether the drive meets the requirements.|Observed whether the U0-34 is often greater than the servo limit power (overload 110%) during servo operation. When ER.43 alarm is found in the process of machine adjustment, please check whether the servo power is suitable. It is recommended to replace the driver model with higher power. 957 +|Servo drive fault|The servo drive is still faulty after power on again|Servo drive may be damaged, contact the manufacturer's technician for repair. 958 + 959 +**Er.45 Drive Blocking Overtemperature Protection** 960 + 961 +Fault 962 + 963 +|=(% style="width: 771px;" %)Servo drive panel display|=(% style="width: 650px;" %)Fault name 964 +|(% style="width:771px" %)((( 965 +(% style="text-align:center" %) 966 +[[image:1719997732882-739.png||height="80" width="203"]] 967 +)))|(% style="width:650px" %)Driver Blocking Overtemperature Protection 968 + 969 +Troubleshooting 970 + 971 +|=Reason|=Troubleshooting|=Treatment 972 +|Check whether U0-39 load torque percentage exceeds the maximum torque of the motor for 3 seconds or observe whether the load torque at the waveform interface of the oscilloscope of the upper computer is greater than the maximum torque of the motor and the motor is blocked.|Check whether U0-39 load torque percentage exceeds the maximum torque of the motor, and observe whether the motor is stuck.|Observable maximum torque observe whether the load torque on the waveform interface of the host computer oscilloscope is greater than the motor maximum torque or check whether U0-39 load torque percentage exceeds the motor maximum torque for 3 seconds. 973 + 974 + 975 +(% style="text-align:center" %) 976 +[[image:1687762670698-912.png]] 977 + 855 855 **Er.60 ADC conversion is not complete** 856 856 857 857 Fault 858 858 859 859 |=**Servo drive panel display**|=**Fault name** 860 -|[[image:image-20220709170943-2.png]]|ADC conversion is not complete 983 +|((( 984 +(% style="text-align:center" %) 985 +[[image:image-20220709170943-2.png]] 986 +)))|ADC conversion is not complete 861 861 862 862 Troubleshooting 863 863 ... ... @@ -871,7 +871,10 @@ 871 871 Fault 872 872 873 873 |=(% style="width: 470px;" %)**Servo drive panel display**|=(% style="width: 605px;" %)**Fault name** 874 -|(% style="width:470px" %)[[image:image-20220709170950-3.png]]|(% style="width:605px" %)Internal software fault 1000 +|(% style="width:470px" %)((( 1001 +(% style="text-align:center" %) 1002 +[[image:image-20220709170950-3.png]] 1003 +)))|(% style="width:605px" %)Internal software fault 875 875 876 876 Troubleshooting 877 877 ... ... @@ -883,7 +883,10 @@ 883 883 Fault 884 884 885 885 |=(% style="width: 479px;" %)**Servo drive panel display**|=(% style="width: 596px;" %)**Fault name** 886 -|(% style="width:479px" %)[[image:image-20220709171001-4.png]]|(% style="width:596px" %)Internal software fault 1015 +|(% style="width:479px" %)((( 1016 +(% style="text-align:center" %) 1017 +[[image:image-20220709171001-4.png]] 1018 +)))|(% style="width:596px" %)Internal software fault 887 887 888 888 Troubleshooting 889 889 ... ... @@ -895,7 +895,10 @@ 895 895 Fault 896 896 897 897 |=(% style="width: 468px;" %)**Servo drive panel display**|=(% style="width: 607px;" %)**Fault name** 898 -|(% style="width:468px" %)[[image:image-20220709171011-5.png]]|(% style="width:607px" %)Internal software fault 1030 +|(% style="width:468px" %)((( 1031 +(% style="text-align:center" %) 1032 +[[image:image-20220709171011-5.png]] 1033 +)))|(% style="width:607px" %)Internal software fault 899 899 900 900 Troubleshooting 901 901 ... ... @@ -907,7 +907,10 @@ 907 907 Fault 908 908 909 909 |=(% style="width: 472px;" %)**Servo drive panel display**|=(% style="width: 603px;" %)**Fault name** 910 -|(% style="width:472px" %)[[image:image-20220709171022-6.png]]|(% style="width:603px" %)Internal software fault 1045 +|(% style="width:472px" %)((( 1046 +(% style="text-align:center" %) 1047 +[[image:image-20220709171022-6.png]] 1048 +)))|(% style="width:603px" %)Internal software fault 911 911 912 912 Troubleshooting 913 913 ... ... @@ -919,7 +919,10 @@ 919 919 Fault 920 920 921 921 |=(% style="width: 472px;" %)**Servo drive panel display**|=(% style="width: 603px;" %)**Fault name** 922 -|(% style="width:472px" %)[[image:image-20220709171027-7.png]]|(% style="width:603px" %)Internal software fault 1060 +|(% style="width:472px" %)((( 1061 +(% style="text-align:center" %) 1062 +[[image:image-20220709171027-7.png]] 1063 +)))|(% style="width:603px" %)Internal software fault 923 923 924 924 Troubleshooting 925 925 ... ... @@ -926,12 +926,37 @@ 926 926 |=(% style="width: 212px;" %)**Reason**|=(% style="width: 518px;" %)**Troubleshooting methods**|=(% style="width: 346px;" %)**Handling** 927 927 |(% style="width:212px" %)Servo drive fault|(% style="width:518px" %)Factory reset the parameter (P10-02=1) and power on again. If the servo drive still alarms after multiple operations, it is faulty.|(% style="width:346px" %)If there is still alarm after multiple power-on, contact the technician. 928 928 1070 +**A-80 Drive overpower warning** 1071 + 1072 +Fault 1073 + 1074 +|=Servo drive panel display|=Alarm name 1075 +|((( 1076 +(% style="text-align:center" %) 1077 +[[image:1687763210466-195.png||height="54" width="150"]] 1078 +)))|Drive overpower warning 1079 + 1080 +Troubleshooting 1081 + 1082 +|Reason|Troubleshooting|Handling 1083 +|((( 1084 +The average output power (U0-34) exceeds the limit power of the drive (overload 110%) for more than 5 seconds, the drive will have alarm. 1085 + 1086 + 1087 +)))|Check whether the average output power (U0-34) exceeds the limit (overload 110) The average output power (U0-34) exceeds the limit power (overload 110%) for more than 5 minutes. Check whether the U0-34 exceeds 110% of the rated power of the driver.|Check whether the U0-34 exceeds 110% of the rated power of the driver. When A80 alarm is found in the process of machine adjustment, please check whether the servo power is suitable. 1088 + 1089 +(% style="text-align:center" %) 1090 +[[image:1687763249516-252.png]] 1091 + 929 929 **A-81 Overspeed alarm** 930 930 931 931 Fault 932 932 933 933 |=(% style="width: 498px;" %)**Servo drive panel display**|=(% style="width: 577px;" %)**Fault name** 934 -|(% style="width:498px" %)[[image:image-20220709171047-8.png]]|(% style="width:577px" %)Overspeed alarm 1097 +|(% style="width:498px" %)((( 1098 +(% style="text-align:center" %) 1099 +[[image:image-20220709171047-8.png]] 1100 +)))|(% style="width:577px" %)Overspeed alarm 935 935 936 936 Troubleshooting 937 937 ... ... @@ -945,7 +945,10 @@ 945 945 Fault 946 946 947 947 |=(% style="width: 479px;" %)**Servo drive panel display**|=(% style="width: 596px;" %)**Fault name** 948 -|(% style="width:479px" %)[[image:image-20220709171057-9.png]]|(% style="width:596px" %)Overload 1114 +|(% style="width:479px" %)((( 1115 +(% style="text-align:center" %) 1116 +[[image:image-20220709171057-9.png]] 1117 +)))|(% style="width:596px" %)Overload 949 949 950 950 Troubleshooting 951 951 ... ... @@ -966,7 +966,10 @@ 966 966 Fault 967 967 968 968 |=(% style="width: 461px;" %)**Servo drive panel display**|=(% style="width: 614px;" %)**Fault name** 969 -|(% style="width:461px" %)[[image:image-20220709171112-10.png]]|(% style="width:614px" %)Braking resistor is over temperature or overloaded 1138 +|(% style="width:461px" %)((( 1139 +(% style="text-align:center" %) 1140 +[[image:image-20220709171112-10.png]] 1141 +)))|(% style="width:614px" %)Braking resistor is over temperature or overloaded 970 970 971 971 Troubleshooting 972 972 ... ... @@ -995,7 +995,10 @@ 995 995 Fault 996 996 997 997 |=(% style="width: 454px;" %)**Servo drive panel display**|=(% style="width: 621px;" %)**Fault name** 998 -|(% style="width:454px" %)[[image:image-20220709171124-11.png]]|(% style="width:621px" %)Braking resistor is over temperature or overloaded 1170 +|(% style="width:454px" %)((( 1171 +(% style="text-align:center" %) 1172 +[[image:image-20220709171124-11.png]] 1173 +)))|(% style="width:621px" %)Modified parameters that need to be powered on again to take effect 999 999 1000 1000 Troubleshooting 1001 1001 ... ... @@ -1007,7 +1007,10 @@ 1007 1007 Fault 1008 1008 1009 1009 |=(% style="width: 465px;" %)**Servo drive panel display**|=(% style="width: 610px;" %)**Fault name** 1010 -|(% style="width:465px" %)[[image:image-20220709171137-12.png]]|(% style="width:610px" %)Receive position pulse when servo is OFF 1185 +|(% style="width:465px" %)((( 1186 +(% style="text-align:center" %) 1187 +[[image:image-20220709171137-12.png]] 1188 +)))|(% style="width:610px" %)Receive position pulse when servo is OFF 1011 1011 1012 1012 Troubleshooting 1013 1013 ... ... @@ -1024,7 +1024,10 @@ 1024 1024 Fault 1025 1025 1026 1026 |=(% style="width: 463px;" %)**Servo drive panel display**|=(% style="width: 612px;" %)**Fault name** 1027 -|(% style="width:463px" %)[[image:image-20220709171149-13.png]]|(% style="width:612px" %)Input pulse frequency is too high 1205 +|(% style="width:463px" %)((( 1206 +(% style="text-align:center" %) 1207 +[[image:image-20220709171149-13.png]] 1208 +)))|(% style="width:612px" %)Input pulse frequency is too high 1028 1028 1029 1029 Troubleshooting 1030 1030 ... ... @@ -1038,7 +1038,10 @@ 1038 1038 Fault 1039 1039 1040 1040 |=**Servo drive panel display**|=**Fault name** 1041 -|[[image:image-20220709171200-14.png]]|Main circuit momentary power off 1222 +|((( 1223 +(% style="text-align:center" %) 1224 +[[image:image-20220709171200-14.png]] 1225 +)))|Main circuit momentary power off 1042 1042 1043 1043 Troubleshooting 1044 1044 ... ... @@ -1057,7 +1057,10 @@ 1057 1057 Fault 1058 1058 1059 1059 |=(% style="width: 482px;" %)**Servo drive panel display**|=(% style="width: 593px;" %)**Fault name** 1060 -|(% style="width:482px" %)[[image:image-20220709171217-15.png]]|(% style="width:593px" %)DI port configuration is duplicate 1244 +|(% style="width:482px" %)((( 1245 +(% style="text-align:center" %) 1246 +[[image:image-20220709171217-15.png]] 1247 +)))|(% style="width:593px" %)DI port configuration is duplicate 1061 1061 1062 1062 Troubleshooting 1063 1063 ... ... @@ -1075,7 +1075,10 @@ 1075 1075 Fault 1076 1076 1077 1077 |=**Servo drive panel display**|=**Fault name** 1078 -|[[image:image-20220709171230-16.png]]|DO port configuration i duplicate 1265 +|((( 1266 +(% style="text-align:center" %) 1267 +[[image:image-20220709171230-16.png]] 1268 +)))|DO port configuration i duplicate 1079 1079 1080 1080 Troubleshooting 1081 1081 ... ... @@ -1093,19 +1093,50 @@ 1093 1093 Fault 1094 1094 1095 1095 |=(% style="width: 465px;" %)**Servo drive panel display**|=(% style="width: 610px;" %)**Fault name** 1096 -|(% style="width:465px" %)[[image:image-20220709171241-17.png]]|(% style="width:610px" %)Parameter modification is too frequent 1286 +|(% style="width:465px" %)((( 1287 +(% style="text-align:center" %) 1288 +[[image:image-20220709171241-17.png]] 1289 +)))|(% style="width:610px" %)((( 1290 +Parameter modification is too frequent (modification frequency allowed of function code: 6 hours/150 times 1097 1097 1292 + Note: 32-bit function code: recorded as 2 times) 1293 +))) 1294 + 1098 1098 Troubleshooting 1099 1099 1100 -|=(% style="width: 232px;" %)**Reason**|=(% style="width: 459px;" %)**Troubleshooting methods**|=(% style="width: 385px;" %)**Handling** 1101 -|(% style="width:232px" %)Parameter modification is too frequent|(% style="width:459px" %)Check whether the host computer frequently modifies the write parameters|(% style="width:385px" %)Ensuring mechanical operation, reduce the frequency of modifying the write parameters of the host computer 1297 +|Reason|Troubleshooting|Handling 1298 +|EEPROM writing frequency is too high|((( 1299 +Check whether the host computer frequently modifies the parameters (modification frequency allowed of function code: 6 hours/150 times 1102 1102 1301 +Note: 32-bit function code: recorded as 2 times) 1302 + 1303 + 1304 +)))|((( 1305 +(1) During machine adjustment, A91 warning (6 hours/150 times) caused by manual frequent modification of function codes can be cleared through P10-03. In other cases, please check the PLC program 1306 + 1307 +(2) If A91 warning appears in the normal working mode of the machine, please check whether the PLC program frequently modifies the function code. 1308 + 1309 +(3) When the function code needs to be modified frequently, it is recommended to close Modbus write to EEPROM (P12-4 is set to 0) 1310 +))) 1311 +|(% rowspan="3" %)external interference|Check for strong magnetic fields nearby|Eliminate nearby strong magnetic interference 1312 +|Check whether there are sources of interference such as power supply inverter equipment nearby|Separate strong and weak power as much as possible, with good ground contact between motor and servo drive, and keep away from power cable wiring. 1313 +|((( 1314 +Increase the abnormal threshold setting of P0-31 encoder read-write check. 1315 + 1316 + 1317 +)))|Eliminate the A93 warning by increasing the exception threshold is suitable as a temporary solution. The disadvantage is that the motor may run in an unstable state. 1318 +|Encoder fault|Manually rotate the motor shaft counterclockwise or clockwise to observe whether the monitoring quantity U0-30 (electrical angle) changes regularly|If the value of U0-30 (electrical angle) changes abruptly or does not change, the encoder itself may have problems, please replace the motor or encoder. 1319 +|Servo drive fault|●Cross-verification. Use the normal motor, encoder cable to connect to the servo drive. If the servo drive still have alarm, it is servo fault.|Servo driver may be damaged, please contact the manufacturer's technician. 1320 + 1103 1103 **A-92 Low encoder battery voltage warning** 1104 1104 1105 1105 Fault 1106 1106 1107 1107 |=**Servo drive panel display**|=**Fault name** 1108 -|[[image:image-20220709171253-18.png]]|Low encoder battery voltage warning 1326 +|((( 1327 +(% style="text-align:center" %) 1328 +[[image:image-20220709171253-18.png]] 1329 +)))|Low encoder battery voltage warning 1109 1109 1110 1110 Troubleshooting 1111 1111 ... ... @@ -1116,12 +1116,17 @@ 1116 1116 1117 1117 Fault 1118 1118 1119 -|=(% style="width: 378px;" %)**Servo drive panel display**|=(% style="width: 697px;" %)**Fault name** 1120 -|(% style="width:378px" %)[[image:image-20220709171304-19.png]]|(% style="width:697px" %)Abnormal and frequency of encoder read and write check is too high 1340 +|=(% style="width: 611px;" %)**Servo drive panel display**|=(% style="width: 811px;" %)**Fault name** 1341 +|(% style="width:611px" %)((( 1342 +(% style="text-align:center" %) 1343 +[[image:image-20220709171304-19.png]] 1344 +)))|(% style="width:811px" %)The abnormal frequency of encoder read-write verification is too high 1121 1121 1122 1122 Troubleshooting 1123 1123 1124 1124 |=(% style="width: 235px;" %)**Reason**|=(% style="width: 446px;" %)**Troubleshooting methods**|=(% style="width: 395px;" %)**Handling** 1125 -|(% rowspan=" 2" style="width:235px" %)External interference|(% style="width:446px" %)Check for strong magnetic fields nearby|(% style="width:395px" %)Eliminate nearby strong magnetic interference1349 +|(% colspan="1" rowspan="3" style="width:235px" %)External interference|(% style="width:446px" %)Check for strong magnetic fields nearby|(% style="width:395px" %)Eliminate nearby strong magnetic interference 1126 1126 |(% style="width:446px" %)Check whether there are sources of interference such as power supply inverter equipment nearby|(% style="width:395px" %)Separate strong and weak power as much as possible, with good ground contact between motor and servo drive, and keep away from power cable wiring. 1351 +|(% style="width:446px" %)Increase the abnormal threshold setting of P0-31.|(% style="width:395px" %)This method is suitable as a temporary workaround to eliminate the A93 warning. It may cause an unstable state in the operation of the motor. 1352 +|(% style="width:235px" %)Encoder issue|(% style="width:446px" %)Manually rotate the motor shaft slowly, and observe the changes of the monitoring quantity U0-30 (electrical angle).|(% style="width:395px" %)If the value of U0-30 (electrical angle) changes suddenly or does not change, it may be a problem with the encoder, please replace the motor or encoder. 1127 1127 |(% style="width:235px" %)Internal servo drive fault|(% style="width:446px" %)Cross-verification. Use the normal motor, encoder cable to connect to the servo drive, only connect the encoder cable. If the servo drive still alarm, it is failure.|(% style="width:395px" %)Contact technician for repair
- 1687762670698-912.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Jim - Size
-
... ... @@ -1,0 +1,1 @@ 1 +99.7 KB - Content
- 1687763210466-195.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Jim - Size
-
... ... @@ -1,0 +1,1 @@ 1 +7.1 KB - Content
- 1687763249516-252.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Jim - Size
-
... ... @@ -1,0 +1,1 @@ 1 +104.1 KB - Content
- 1719997732882-739.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Mora - Size
-
... ... @@ -1,0 +1,1 @@ 1 +7.1 KB - Content
- 企业微信截图_16877625944107.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Jim - Size
-
... ... @@ -1,0 +1,1 @@ 1 +2.9 KB - Content