Changes for page 10 Malfunctions
Last modified by Theodore Xu on 2025/02/13 17:16
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -478,14 +478,14 @@ 478 478 220V drive: U0-31 less than 200V; 479 479 380V drive: U0-31 less than 400V.|(% style="width:355px" %)Contact technician for repair 480 480 481 -**Er.22 Main power supply undervoltage**481 +**Er.22 Main power supply overvoltage** 482 482 483 483 Fault 484 484 485 485 |=(% style="width: 457px;" %)**Servo drive panel display**|=(% style="width: 618px;" %)**Fault name** 486 -|(% style="width:457px" %)[[image:image-20220709165541-11.png]]|(% style="width:618px" %)Main power supply undervoltage486 +|(% style="width:457px" %)[[image:image-20220709165541-11.png]]|(% style="width:618px" %)Main power supply overvoltage 487 487 488 -Reason: DC bus voltage is lower than the fault value.488 +Reason: DC bus voltage is bigger than the fault value. 489 489 490 490 1. 220V drive: DC bus voltage normal value is 310V; DC bus voltage fault value is 390V. 491 491 1. 380V drive: DC bus voltage normal value is 540V; DC bus voltage fault value is 670V. ... ... @@ -571,7 +571,7 @@ 571 571 Fault 572 572 573 573 |=**Servo drive panel display**|=**Fault name** 574 -|[[image:image-20220709165622-15.png]]| Braking resistorresistanceis too large574 +|[[image:image-20220709165622-15.png]]|Motor code wrong 575 575 576 576 Troubleshooting 577 577 ... ... @@ -1031,7 +1031,7 @@ 1031 1031 Fault 1032 1032 1033 1033 |=(% style="width: 454px;" %)**Servo drive panel display**|=(% style="width: 621px;" %)**Fault name** 1034 -|(% style="width:454px" %)[[image:image-20220709171124-11.png]]|(% style="width:621px" %) Brakingresistorisovertemperature oroverloaded1034 +|(% style="width:454px" %)[[image:image-20220709171124-11.png]]|(% style="width:621px" %)Modified parameters that need to be powered on again to take effect 1035 1035 1036 1036 Troubleshooting 1037 1037 ... ... @@ -1178,11 +1178,13 @@ 1178 1178 Fault 1179 1179 1180 1180 |=(% style="width: 378px;" %)**Servo drive panel display**|=(% style="width: 697px;" %)**Fault name** 1181 -|(% style="width:378px" %)[[image:image-20220709171304-19.png]]|(% style="width:697px" %) Abnormalandfrequencyandwritecheckis too high1181 +|(% style="width:378px" %)[[image:image-20220709171304-19.png]]|(% style="width:697px" %)The abnormal frequency of encoder read-write verification is too high 1182 1182 1183 1183 Troubleshooting 1184 1184 1185 1185 |=(% style="width: 235px;" %)**Reason**|=(% style="width: 446px;" %)**Troubleshooting methods**|=(% style="width: 395px;" %)**Handling** 1186 -|(% rowspan=" 2" style="width:235px" %)External interference|(% style="width:446px" %)Check for strong magnetic fields nearby|(% style="width:395px" %)Eliminate nearby strong magnetic interference1186 +|(% colspan="1" rowspan="3" style="width:235px" %)External interference|(% style="width:446px" %)Check for strong magnetic fields nearby|(% style="width:395px" %)Eliminate nearby strong magnetic interference 1187 1187 |(% style="width:446px" %)Check whether there are sources of interference such as power supply inverter equipment nearby|(% style="width:395px" %)Separate strong and weak power as much as possible, with good ground contact between motor and servo drive, and keep away from power cable wiring. 1188 +|(% style="width:446px" %)Increase the abnormal threshold setting of P0-31.|(% style="width:395px" %)This method is suitable as a temporary workaround to eliminate the A93 warning. It may cause an unstable state in the operation of the motor. 1189 +|(% style="width:235px" %)Encoder issue|(% style="width:446px" %)Manually rotate the motor shaft slowly, and observe the changes of the monitoring quantity U0-30 (electrical angle).|(% style="width:395px" %)If the value of U0-30 (electrical angle) changes suddenly or does not change, it may be a problem with the encoder, please replace the motor or encoder. 1188 1188 |(% style="width:235px" %)Internal servo drive fault|(% style="width:446px" %)Cross-verification. Use the normal motor, encoder cable to connect to the servo drive, only connect the encoder cable. If the servo drive still alarm, it is failure.|(% style="width:395px" %)Contact technician for repair