... ... @@ -478,14 +478,14 @@
478 478  220V drive: U0-31 less than 200V;
479 479  380V drive: U0-31 less than 400V.|(% style="width:355px" %)Contact technician for repair
480 480  
481 -**Er.22 Main power supply undervoltage**
481 +**Er.22 Main power supply overvoltage**
482 482  
483 483  Fault
484 484  
485 485  |=(% style="width: 457px;" %)**Servo drive panel display**|=(% style="width: 618px;" %)**Fault name**
486 -|(% style="width:457px" %)[[image:image-20220709165541-11.png]]|(% style="width:618px" %)Main power supply undervoltage
486 +|(% style="width:457px" %)[[image:image-20220709165541-11.png]]|(% style="width:618px" %)Main power supply overvoltage
487 487  
488 -Reason: DC bus voltage is lower than the fault value.
488 +Reason: DC bus voltage is bigger than the fault value.
489 489  
490 490  1. 220V drive: DC bus voltage normal value is 310V; DC bus voltage fault value is 390V.
491 491  1. 380V drive: DC bus voltage normal value is 540V; DC bus voltage fault value is 670V.