Changes for page 11 Appendix

Last modified by Theodore Xu on 2025/04/27 11:22

From version 3.1
edited by Stone Wu
on 2022/06/11 11:15
Change comment: Upload new image "11-1 1.jpg", version 1.1
To version 7.1
edited by Stone Wu
on 2022/06/11 13:02
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -34,7 +34,7 @@
34 34  
35 35  Some of parameters need to be power on again to take effect. Please refer to the parameter table.
36 36  
37 -|(% style="text-align:center; vertical-align:middle" %)[[image:http://docs.we-con.com.cn/wiki/servo/download/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/WebHome/Wecon%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29_html_6db94f5d0421f97a.png?rev=1.1||alt="Wecon VD2 SA Series Servo Drives Manual (Full V1.1)_html_6db94f5d0421f97a.png"]]
37 +|(% style="text-align:center; vertical-align:middle" %)[[image:image-20220611125757-1.png]]
38 38  |The following parameter table is described in terms of VD2-014SA1G model V1.13 firmware version. Some of the parameters are different from the old version.
39 39  
40 40  == **Group P00 Basic settings** ==
... ... @@ -787,68 +787,64 @@
787 787  
788 788  = **Wire** =
789 789  
790 -|(% style="text-align:center; vertical-align:middle" %)**Wire model**|(% style="text-align:center; vertical-align:middle" %)**Wire length**|(% style="text-align:center; vertical-align:middle" %)**Wire exterior**
791 -|(% style="text-align:center; vertical-align:middle" %)P-Z3O1-R4M-3MX4|(% style="text-align:center; vertical-align:middle" %)3m|(% rowspan="3" style="text-align:center; vertical-align:middle" %)(((
792 -
790 +|(% style="text-align:center; vertical-align:middle; width:210px" %)**Wire model**|(% style="text-align:center; vertical-align:middle; width:96px" %)**Wire length**|(% style="text-align:center; vertical-align:middle" %)**Wire exterior**
791 +|(% style="text-align:center; vertical-align:middle; width:210px" %)P-Z3O1-R4M-3MX4|(% style="text-align:center; vertical-align:middle; width:96px" %)3m|(% rowspan="3" style="text-align:center; vertical-align:middle" %)(((
792 +[[image:https://docs.we-con.com.cn/bin/download/Servo/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/11%20Appendix/WebHome/11-1%201.jpg?rev=1.1]]
793 793  
794 -[[image:image-20220611111415-1.jpeg]]
795 -
796 -[[image:image-20220611111423-2.png]]
797 -
798 798  Suitable for VD2A drive connecting 60/80 flange lead wire motor
799 799  )))
800 -|(% style="text-align:center; vertical-align:middle" %)P-Z3O1-R4M-5MX4|(% style="text-align:center; vertical-align:middle" %)5m
801 -|(% style="text-align:center; vertical-align:middle" %)P-Z3O1-R4M-10MX4|(% style="text-align:center; vertical-align:middle" %)10m
802 -|(% style="text-align:center; vertical-align:middle" %)P-U3O1-R4M-3MX4|(% style="text-align:center; vertical-align:middle" %)3m|(% rowspan="3" style="text-align:center; vertical-align:middle" %)(((
803 -[[image:http://docs.we-con.com.cn/wiki/servo/download/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/WebHome/Wecon%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29_html_5ca4694abbaa575.gif?rev=1.1||alt="Wecon VD2 SA Series Servo Drives Manual (Full V1.1)_html_5ca4694abbaa575.gif"]]
796 +|(% style="text-align:center; vertical-align:middle; width:210px" %)P-Z3O1-R4M-5MX4|(% style="text-align:center; vertical-align:middle; width:96px" %)5m
797 +|(% style="text-align:center; vertical-align:middle; width:210px" %)P-Z3O1-R4M-10MX4|(% style="text-align:center; vertical-align:middle; width:96px" %)10m
798 +|(% style="text-align:center; vertical-align:middle; width:210px" %)P-U3O1-R4M-3MX4|(% style="text-align:center; vertical-align:middle; width:96px" %)3m|(% rowspan="3" style="text-align:center; vertical-align:middle" %)(((
799 +[[image:image-20220611130229-1.jpeg]]
804 804  
805 805  Suitable for VD2B drive connecting 80 flange lead wire motor
806 806  )))
807 -|(% style="text-align:center; vertical-align:middle" %)P-U3O1-R4M-5MX4|(% style="text-align:center; vertical-align:middle" %)5m
808 -|(% style="text-align:center; vertical-align:middle" %)P-U3O1-R4M-10MX4|(% style="text-align:center; vertical-align:middle" %)10m
803 +|(% style="text-align:center; vertical-align:middle; width:210px" %)P-U3O1-R4M-5MX4|(% style="text-align:center; vertical-align:middle; width:96px" %)5m
804 +|(% style="text-align:center; vertical-align:middle; width:210px" %)P-U3O1-R4M-10MX4|(% style="text-align:center; vertical-align:middle; width:96px" %)10m
809 809  
810 -|(% style="text-align:center; vertical-align:middle" %)P-Z4-R4M-3MX4|(% style="text-align:center; vertical-align:middle" %)3m|(% rowspan="3" style="text-align:center; vertical-align:middle" %)(((
811 -[[image:http://docs.we-con.com.cn/wiki/servo/download/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/WebHome/Wecon%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29_html_996603eb09860541.gif?rev=1.1||alt="Wecon VD2 SA Series Servo Drives Manual (Full V1.1)_html_996603eb09860541.gif"]]
806 +|(% style="text-align:center; vertical-align:middle; width:214px" %)P-Z4-R4M-3MX4|(% style="text-align:center; vertical-align:middle; width:92px" %)3m|(% rowspan="3" style="text-align:center; vertical-align:middle" %)(((
807 +[[image:image-20220611130233-2.jpeg]]
812 812  
813 813  Suitable for VD2F drive connecting 40/60/80 flange lead wire motor
814 814  )))
815 -|(% style="text-align:center; vertical-align:middle" %)P-Z4-R4M-5MX4|(% style="text-align:center; vertical-align:middle" %)5m
816 -|(% style="text-align:center; vertical-align:middle" %)P-Z4-R4M-10MX4|(% style="text-align:center; vertical-align:middle" %)10m
817 -|(% style="text-align:center; vertical-align:middle" %)P-Z3O1-H28J4M-3MX4|(% style="text-align:center; vertical-align:middle" %)3m|(% rowspan="3" style="text-align:center; vertical-align:middle" %)(((
818 -[[image:http://docs.we-con.com.cn/wiki/servo/download/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/WebHome/Wecon%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29_html_a271a028bb4ea2c.gif?rev=1.1||alt="Wecon VD2 SA Series Servo Drives Manual (Full V1.1)_html_a271a028bb4ea2c.gif"]]
811 +|(% style="text-align:center; vertical-align:middle; width:214px" %)P-Z4-R4M-5MX4|(% style="text-align:center; vertical-align:middle; width:92px" %)5m
812 +|(% style="text-align:center; vertical-align:middle; width:214px" %)P-Z4-R4M-10MX4|(% style="text-align:center; vertical-align:middle; width:92px" %)10m
813 +|(% style="text-align:center; vertical-align:middle; width:214px" %)P-Z3O1-H28J4M-3MX4|(% style="text-align:center; vertical-align:middle; width:92px" %)3m|(% rowspan="3" style="text-align:center; vertical-align:middle" %)(((
814 +[[image:image-20220611130025-3.png]]
819 819  
820 820  Suitable for VD2A drive connecting 110/130 flange lead wire motor
821 821  )))
822 -|(% style="text-align:center; vertical-align:middle" %)P-Z3O1-H28J4M-5MX4|(% style="text-align:center; vertical-align:middle" %)5m
823 -|(% style="text-align:center; vertical-align:middle" %)P-Z3O1-H28J4M-10MX4|(% style="text-align:center; vertical-align:middle" %)10m
824 -|(% style="text-align:center; vertical-align:middle" %)P-U3O1-H28J4M-3MX4|(% style="text-align:center; vertical-align:middle" %)3m|(% rowspan="3" style="text-align:center; vertical-align:middle" %)(((
825 -[[image:http://docs.we-con.com.cn/wiki/servo/download/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/WebHome/Wecon%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29_html_de4dcb794aa1708f.gif?rev=1.1||alt="Wecon VD2 SA Series Servo Drives Manual (Full V1.1)_html_de4dcb794aa1708f.gif"]]
818 +|(% style="text-align:center; vertical-align:middle; width:214px" %)P-Z3O1-H28J4M-5MX4|(% style="text-align:center; vertical-align:middle; width:92px" %)5m
819 +|(% style="text-align:center; vertical-align:middle; width:214px" %)P-Z3O1-H28J4M-10MX4|(% style="text-align:center; vertical-align:middle; width:92px" %)10m
820 +|(% style="text-align:center; vertical-align:middle; width:214px" %)P-U3O1-H28J4M-3MX4|(% style="text-align:center; vertical-align:middle; width:92px" %)3m|(% rowspan="3" style="text-align:center; vertical-align:middle" %)(((
821 +[[image:image-20220611130032-4.png]]
826 826  
827 827  Suitable for VD2B drive connecting 110/130 flange lead wire motor
828 828  )))
829 -|(% style="text-align:center; vertical-align:middle" %)P-U3O1-H28J4M-5MX4|(% style="text-align:center; vertical-align:middle" %)5m
830 -|(% style="text-align:center; vertical-align:middle" %)P-U3O1-H28J4M-10MX4|(% style="text-align:center; vertical-align:middle" %)10m
831 -|(% style="text-align:center; vertical-align:middle" %)P-Z4-H28J4M-3MX4|(% style="text-align:center; vertical-align:middle" %)3m|(% rowspan="3" style="text-align:center; vertical-align:middle" %)(((
832 -[[image:http://docs.we-con.com.cn/wiki/servo/download/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/WebHome/Wecon%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29_html_d4f272106767c34a.gif?rev=1.1||alt="Wecon VD2 SA Series Servo Drives Manual (Full V1.1)_html_d4f272106767c34a.gif"]]
825 +|(% style="text-align:center; vertical-align:middle; width:214px" %)P-U3O1-H28J4M-5MX4|(% style="text-align:center; vertical-align:middle; width:92px" %)5m
826 +|(% style="text-align:center; vertical-align:middle; width:214px" %)P-U3O1-H28J4M-10MX4|(% style="text-align:center; vertical-align:middle; width:92px" %)10m
827 +|(% style="text-align:center; vertical-align:middle; width:214px" %)P-Z4-H28J4M-3MX4|(% style="text-align:center; vertical-align:middle; width:92px" %)3m|(% rowspan="3" style="text-align:center; vertical-align:middle" %)(((
828 +[[image:image-20220611130038-5.png]]
833 833  
834 834  Suitable for VD2F drive connecting 110/130 flange lead wire motor
835 835  )))
836 -|(% style="text-align:center; vertical-align:middle" %)P-Z4-H28J4M-5MX4|(% style="text-align:center; vertical-align:middle" %)5m
837 -|(% style="text-align:center; vertical-align:middle" %)P-Z4-H28J4M-10MX4|(% style="text-align:center; vertical-align:middle" %)10m
838 -|(% style="text-align:center; vertical-align:middle" %)P-Z3O1-MC4S-3MX4|(% style="text-align:center; vertical-align:middle" %)3m|(% rowspan="3" style="text-align:center; vertical-align:middle" %)(((
839 -[[image:http://docs.we-con.com.cn/wiki/servo/download/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/WebHome/Wecon%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29_html_8642328ca38d4bbe.gif?rev=1.1||alt="Wecon VD2 SA Series Servo Drives Manual (Full V1.1)_html_8642328ca38d4bbe.gif"]]
832 +|(% style="text-align:center; vertical-align:middle; width:214px" %)P-Z4-H28J4M-5MX4|(% style="text-align:center; vertical-align:middle; width:92px" %)5m
833 +|(% style="text-align:center; vertical-align:middle; width:214px" %)P-Z4-H28J4M-10MX4|(% style="text-align:center; vertical-align:middle; width:92px" %)10m
834 +|(% style="text-align:center; vertical-align:middle; width:214px" %)P-Z3O1-MC4S-3MX4|(% style="text-align:center; vertical-align:middle; width:92px" %)3m|(% rowspan="3" style="text-align:center; vertical-align:middle" %)(((
835 +[[image:image-20220611130043-6.png]]
840 840  
841 841  Suitable for VD2A drive connecting 60/80 flange lead wire motor
842 842  )))
843 -|(% style="text-align:center; vertical-align:middle" %)P-Z3O1-MC4S-5MX4|(% style="text-align:center; vertical-align:middle" %)5m
844 -|(% style="text-align:center; vertical-align:middle" %)P-Z3O1-MC4S-10MX4|(% style="text-align:center; vertical-align:middle" %)10m
845 -|(% style="text-align:center; vertical-align:middle" %)P-Z4-MC4S-3MX4|(% style="text-align:center; vertical-align:middle" %)3m|(% rowspan="3" style="text-align:center; vertical-align:middle" %)(((
846 -[[image:http://docs.we-con.com.cn/wiki/servo/download/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/WebHome/Wecon%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29_html_c7ee1a4a6c7302ff.gif?rev=1.1||alt="Wecon VD2 SA Series Servo Drives Manual (Full V1.1)_html_c7ee1a4a6c7302ff.gif"]]
839 +|(% style="text-align:center; vertical-align:middle; width:214px" %)P-Z3O1-MC4S-5MX4|(% style="text-align:center; vertical-align:middle; width:92px" %)5m
840 +|(% style="text-align:center; vertical-align:middle; width:214px" %)P-Z3O1-MC4S-10MX4|(% style="text-align:center; vertical-align:middle; width:92px" %)10m
841 +|(% style="text-align:center; vertical-align:middle; width:214px" %)P-Z4-MC4S-3MX4|(% style="text-align:center; vertical-align:middle; width:92px" %)3m|(% rowspan="3" style="text-align:center; vertical-align:middle" %)(((
842 +[[image:image-20220611130048-7.png]]
847 847  
848 848  Suitable for VD2F drive connecting 60/80 flange lead wire motor
849 849  )))
850 -|(% style="text-align:center; vertical-align:middle" %)P-Z4-MC4S-5MX4|(% style="text-align:center; vertical-align:middle" %)5m
851 -|(% style="text-align:center; vertical-align:middle" %)P-Z4-MC4S-10MX4|(% style="text-align:center; vertical-align:middle" %)10m
846 +|(% style="text-align:center; vertical-align:middle; width:214px" %)P-Z4-MC4S-5MX4|(% style="text-align:center; vertical-align:middle; width:92px" %)5m
847 +|(% style="text-align:center; vertical-align:middle; width:214px" %)P-Z4-MC4S-10MX4|(% style="text-align:center; vertical-align:middle; width:92px" %)10m
852 852  
853 853  Table 11-1 Servo motor power cable exterior diagram
854 854  
image-20220611125757-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Stone
Size
... ... @@ -1,0 +1,1 @@
1 +1.8 KB
Content