Changes for page 11 Appendix

Last modified by Theodore Xu on 2025/04/27 11:22

From version 57.2
edited by Karen
on 2023/05/17 11:48
Change comment: There is no comment for this version
To version 56.1
edited by Karen
on 2023/05/17 11:46
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -378,7 +378,6 @@
378 378  |=(% style="text-align: center; vertical-align: middle; width: 179px;" %)__P10-04__|(% style="text-align:center; vertical-align:middle; width:274px" %)Motor overload protection time factor|(% style="text-align:center; vertical-align:middle; width:186px" %)Operation setting|(% style="text-align:center; vertical-align:middle; width:210px" %)Effective immediately|(% style="text-align:center; vertical-align:middle; width:106px" %)100|(% style="text-align:center; vertical-align:middle" %)0 to 800|(% style="text-align:center; vertical-align:middle" %)%|(% style="text-align:center; vertical-align:middle" %)0x0A04|(% style="text-align:center; vertical-align:middle; width:90px" %)2564|(% style="text-align:center; vertical-align:middle; width:123px" %)16-bit
379 379  |=(% style="text-align: center; vertical-align: middle; width: 179px;" %)__P10-05__|(% style="text-align:center; vertical-align:middle; width:274px" %)Motor model|(% style="text-align:center; vertical-align:middle; width:186px" %)Operation setting|(% style="text-align:center; vertical-align:middle; width:210px" %)Power-on again|(% style="text-align:center; vertical-align:middle; width:106px" %)0|(% style="text-align:center; vertical-align:middle" %)0 to 65535|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)0x0A05|(% style="text-align:center; vertical-align:middle; width:90px" %)2565|(% style="text-align:center; vertical-align:middle; width:123px" %)16-bit
380 380  |=(% style="text-align: center; vertical-align: middle; width: 179px;" %)__P10-06__|(% style="text-align:center; vertical-align:middle; width:274px" %)Multi-turn absolute encoder reset|(% style="text-align:center; vertical-align:middle; width:186px" %)Shutdown setting|(% style="text-align:center; vertical-align:middle; width:210px" %)Effective immediately|(% style="text-align:center; vertical-align:middle; width:106px" %)0|(% style="text-align:center; vertical-align:middle" %)0 to 1|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)0x0A06|(% style="text-align:center; vertical-align:middle; width:90px" %)2566|(% style="text-align:center; vertical-align:middle; width:123px" %)16-bit
381 -|=(% style="text-align: center; vertical-align: middle; width: 179px;" %)__P10-07__|(% style="text-align:center; vertical-align:middle; width:274px" %)Set machine code manually|(% style="text-align:center; vertical-align:middle; width:186px" %)Operation setting|(% style="text-align:center; vertical-align:middle; width:210px" %)Power-on again|(% style="text-align:center; vertical-align:middle; width:106px" %)0|(% style="text-align:center; vertical-align:middle" %)0 to 1|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)0x0A07|(% style="text-align:center; vertical-align:middle; width:90px" %)2567|(% style="text-align:center; vertical-align:middle; width:123px" %)16-bit
382 382  
383 383  == **Group P12 Communication parameters** ==
384 384  
... ... @@ -389,7 +389,6 @@
389 389  |=(% style="text-align: center; vertical-align: middle; width: 153px;" %)__P12-03__|(% style="text-align:center; vertical-align:middle; width:319px" %)Serial data format|(% style="text-align:center; vertical-align:middle; width:223px" %)Operation setting|(% style="text-align:center; vertical-align:middle; width:216px" %)Effective immediately|(% style="text-align:center; vertical-align:middle; width:121px" %)0|(% style="text-align:center; vertical-align:middle" %)0 to 3|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)0x0C03|(% style="text-align:center; vertical-align:middle; width:68px" %)3075|(% style="text-align:center; vertical-align:middle; width:127px" %)16-bit
390 390  |=(% style="text-align: center; vertical-align: middle; width: 153px;" %)__P12-04__|(% style="text-align:center; vertical-align:middle; width:319px" %)Modbus communication data is written into EEPROM|(% style="text-align:center; vertical-align:middle; width:223px" %)Operation setting|(% style="text-align:center; vertical-align:middle; width:216px" %)Effective immediately|(% style="text-align:center; vertical-align:middle; width:121px" %)0|(% style="text-align:center; vertical-align:middle" %)0 to 1|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)0x0C04|(% style="text-align:center; vertical-align:middle; width:68px" %)3076|(% style="text-align:center; vertical-align:middle; width:127px" %)16-bit
391 391  |=(% style="text-align: center; vertical-align: middle; width: 153px;" %)__P12-05__|(% style="text-align:center; vertical-align:middle; width:319px" %)RS422/RS485 function selection|(% style="text-align:center; vertical-align:middle; width:223px" %)Operation setting|(% style="text-align:center; vertical-align:middle; width:216px" %)Effective immediately|(% style="text-align:center; vertical-align:middle; width:121px" %)0|(% style="text-align:center; vertical-align:middle" %)0 to 1|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)0x0C05|(% style="text-align:center; vertical-align:middle; width:68px" %)3077|(% style="text-align:center; vertical-align:middle; width:127px" %)16-bit
392 -|=(% style="text-align: center; vertical-align: middle; width: 153px;" %)__P12-06__|(% style="text-align:center; vertical-align:middle; width:319px" %)Modbus 32-bit variable high and low byte order|(% style="text-align:center; vertical-align:middle; width:223px" %)Operation setting|(% style="text-align:center; vertical-align:middle; width:216px" %)Effective immediately|(% style="text-align:center; vertical-align:middle; width:121px" %)0|(% style="text-align:center; vertical-align:middle" %)0 to 1|(% style="text-align:center; vertical-align:middle" %)|(% style="text-align:center; vertical-align:middle" %)0x0C06|(% style="text-align:center; vertical-align:middle; width:68px" %)3078|(% style="text-align:center; vertical-align:middle; width:127px" %)16-bit
393 393  
394 394  == **Group P13 Virtual input terminal** ==
395 395