Changes for page 11 Appendix
Last modified by Theodore Xu on 2025/04/27 11:22
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -389,7 +389,6 @@ 389 389 |=(% style="text-align: center; vertical-align: middle; width: 153px;" %)__P12-03__|(% style="text-align:center; vertical-align:middle; width:319px" %)Serial data format|(% style="text-align:center; vertical-align:middle; width:223px" %)Operation setting|(% style="text-align:center; vertical-align:middle; width:216px" %)Effective immediately|(% style="text-align:center; vertical-align:middle; width:121px" %)0|(% style="text-align:center; vertical-align:middle" %)0 to 3|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)0x0C03|(% style="text-align:center; vertical-align:middle; width:68px" %)3075|(% style="text-align:center; vertical-align:middle; width:127px" %)16-bit 390 390 |=(% style="text-align: center; vertical-align: middle; width: 153px;" %)__P12-04__|(% style="text-align:center; vertical-align:middle; width:319px" %)Modbus communication data is written into EEPROM|(% style="text-align:center; vertical-align:middle; width:223px" %)Operation setting|(% style="text-align:center; vertical-align:middle; width:216px" %)Effective immediately|(% style="text-align:center; vertical-align:middle; width:121px" %)0|(% style="text-align:center; vertical-align:middle" %)0 to 1|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)0x0C04|(% style="text-align:center; vertical-align:middle; width:68px" %)3076|(% style="text-align:center; vertical-align:middle; width:127px" %)16-bit 391 391 |=(% style="text-align: center; vertical-align: middle; width: 153px;" %)__P12-05__|(% style="text-align:center; vertical-align:middle; width:319px" %)RS422/RS485 function selection|(% style="text-align:center; vertical-align:middle; width:223px" %)Operation setting|(% style="text-align:center; vertical-align:middle; width:216px" %)Effective immediately|(% style="text-align:center; vertical-align:middle; width:121px" %)0|(% style="text-align:center; vertical-align:middle" %)0 to 1|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)0x0C05|(% style="text-align:center; vertical-align:middle; width:68px" %)3077|(% style="text-align:center; vertical-align:middle; width:127px" %)16-bit 392 -|=(% style="text-align: center; vertical-align: middle; width: 153px;" %)__P12-06__|(% style="text-align:center; vertical-align:middle; width:319px" %)Modbus 32-bit variable high and low byte order|(% style="text-align:center; vertical-align:middle; width:223px" %)Operation setting|(% style="text-align:center; vertical-align:middle; width:216px" %)Effective immediately|(% style="text-align:center; vertical-align:middle; width:121px" %)0|(% style="text-align:center; vertical-align:middle" %)0 to 1|(% style="text-align:center; vertical-align:middle" %)|(% style="text-align:center; vertical-align:middle" %)0x0C06|(% style="text-align:center; vertical-align:middle; width:68px" %)3078|(% style="text-align:center; vertical-align:middle; width:127px" %)16-bit 393 393 394 394 == **Group P13 Virtual input terminal** == 395 395