Changes for page 11 Appendix

Last modified by Theodore Xu on 2025/04/27 11:22

From version 6.1
edited by Stone Wu
on 2022/06/11 13:01
Change comment: There is no comment for this version
To version 7.1
edited by Stone Wu
on 2022/06/11 13:02
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -787,64 +787,64 @@
787 787  
788 788  = **Wire** =
789 789  
790 -|(% style="text-align:center; vertical-align:middle" %)**Wire model**|(% style="text-align:center; vertical-align:middle" %)**Wire length**|(% style="text-align:center; vertical-align:middle" %)**Wire exterior**
791 -|(% style="text-align:center; vertical-align:middle" %)P-Z3O1-R4M-3MX4|(% style="text-align:center; vertical-align:middle" %)3m|(% rowspan="3" style="text-align:center; vertical-align:middle" %)(((
790 +|(% style="text-align:center; vertical-align:middle; width:210px" %)**Wire model**|(% style="text-align:center; vertical-align:middle; width:96px" %)**Wire length**|(% style="text-align:center; vertical-align:middle" %)**Wire exterior**
791 +|(% style="text-align:center; vertical-align:middle; width:210px" %)P-Z3O1-R4M-3MX4|(% style="text-align:center; vertical-align:middle; width:96px" %)3m|(% rowspan="3" style="text-align:center; vertical-align:middle" %)(((
792 792  [[image:https://docs.we-con.com.cn/bin/download/Servo/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/11%20Appendix/WebHome/11-1%201.jpg?rev=1.1]]
793 793  
794 794  Suitable for VD2A drive connecting 60/80 flange lead wire motor
795 795  )))
796 -|(% style="text-align:center; vertical-align:middle" %)P-Z3O1-R4M-5MX4|(% style="text-align:center; vertical-align:middle" %)5m
797 -|(% style="text-align:center; vertical-align:middle" %)P-Z3O1-R4M-10MX4|(% style="text-align:center; vertical-align:middle" %)10m
798 -|(% style="text-align:center; vertical-align:middle" %)P-U3O1-R4M-3MX4|(% style="text-align:center; vertical-align:middle" %)3m|(% rowspan="3" style="text-align:center; vertical-align:middle" %)(((
799 -[[image:image-20220611125939-1.png]]
796 +|(% style="text-align:center; vertical-align:middle; width:210px" %)P-Z3O1-R4M-5MX4|(% style="text-align:center; vertical-align:middle; width:96px" %)5m
797 +|(% style="text-align:center; vertical-align:middle; width:210px" %)P-Z3O1-R4M-10MX4|(% style="text-align:center; vertical-align:middle; width:96px" %)10m
798 +|(% style="text-align:center; vertical-align:middle; width:210px" %)P-U3O1-R4M-3MX4|(% style="text-align:center; vertical-align:middle; width:96px" %)3m|(% rowspan="3" style="text-align:center; vertical-align:middle" %)(((
799 +[[image:image-20220611130229-1.jpeg]]
800 800  
801 801  Suitable for VD2B drive connecting 80 flange lead wire motor
802 802  )))
803 -|(% style="text-align:center; vertical-align:middle" %)P-U3O1-R4M-5MX4|(% style="text-align:center; vertical-align:middle" %)5m
804 -|(% style="text-align:center; vertical-align:middle" %)P-U3O1-R4M-10MX4|(% style="text-align:center; vertical-align:middle" %)10m
803 +|(% style="text-align:center; vertical-align:middle; width:210px" %)P-U3O1-R4M-5MX4|(% style="text-align:center; vertical-align:middle; width:96px" %)5m
804 +|(% style="text-align:center; vertical-align:middle; width:210px" %)P-U3O1-R4M-10MX4|(% style="text-align:center; vertical-align:middle; width:96px" %)10m
805 805  
806 -|(% style="text-align:center; vertical-align:middle" %)P-Z4-R4M-3MX4|(% style="text-align:center; vertical-align:middle" %)3m|(% rowspan="3" style="text-align:center; vertical-align:middle" %)(((
807 -[[image:image-20220611130019-2.png]]
806 +|(% style="text-align:center; vertical-align:middle; width:214px" %)P-Z4-R4M-3MX4|(% style="text-align:center; vertical-align:middle; width:92px" %)3m|(% rowspan="3" style="text-align:center; vertical-align:middle" %)(((
807 +[[image:image-20220611130233-2.jpeg]]
808 808  
809 809  Suitable for VD2F drive connecting 40/60/80 flange lead wire motor
810 810  )))
811 -|(% style="text-align:center; vertical-align:middle" %)P-Z4-R4M-5MX4|(% style="text-align:center; vertical-align:middle" %)5m
812 -|(% style="text-align:center; vertical-align:middle" %)P-Z4-R4M-10MX4|(% style="text-align:center; vertical-align:middle" %)10m
813 -|(% style="text-align:center; vertical-align:middle" %)P-Z3O1-H28J4M-3MX4|(% style="text-align:center; vertical-align:middle" %)3m|(% rowspan="3" style="text-align:center; vertical-align:middle" %)(((
811 +|(% style="text-align:center; vertical-align:middle; width:214px" %)P-Z4-R4M-5MX4|(% style="text-align:center; vertical-align:middle; width:92px" %)5m
812 +|(% style="text-align:center; vertical-align:middle; width:214px" %)P-Z4-R4M-10MX4|(% style="text-align:center; vertical-align:middle; width:92px" %)10m
813 +|(% style="text-align:center; vertical-align:middle; width:214px" %)P-Z3O1-H28J4M-3MX4|(% style="text-align:center; vertical-align:middle; width:92px" %)3m|(% rowspan="3" style="text-align:center; vertical-align:middle" %)(((
814 814  [[image:image-20220611130025-3.png]]
815 815  
816 816  Suitable for VD2A drive connecting 110/130 flange lead wire motor
817 817  )))
818 -|(% style="text-align:center; vertical-align:middle" %)P-Z3O1-H28J4M-5MX4|(% style="text-align:center; vertical-align:middle" %)5m
819 -|(% style="text-align:center; vertical-align:middle" %)P-Z3O1-H28J4M-10MX4|(% style="text-align:center; vertical-align:middle" %)10m
820 -|(% style="text-align:center; vertical-align:middle" %)P-U3O1-H28J4M-3MX4|(% style="text-align:center; vertical-align:middle" %)3m|(% rowspan="3" style="text-align:center; vertical-align:middle" %)(((
818 +|(% style="text-align:center; vertical-align:middle; width:214px" %)P-Z3O1-H28J4M-5MX4|(% style="text-align:center; vertical-align:middle; width:92px" %)5m
819 +|(% style="text-align:center; vertical-align:middle; width:214px" %)P-Z3O1-H28J4M-10MX4|(% style="text-align:center; vertical-align:middle; width:92px" %)10m
820 +|(% style="text-align:center; vertical-align:middle; width:214px" %)P-U3O1-H28J4M-3MX4|(% style="text-align:center; vertical-align:middle; width:92px" %)3m|(% rowspan="3" style="text-align:center; vertical-align:middle" %)(((
821 821  [[image:image-20220611130032-4.png]]
822 822  
823 823  Suitable for VD2B drive connecting 110/130 flange lead wire motor
824 824  )))
825 -|(% style="text-align:center; vertical-align:middle" %)P-U3O1-H28J4M-5MX4|(% style="text-align:center; vertical-align:middle" %)5m
826 -|(% style="text-align:center; vertical-align:middle" %)P-U3O1-H28J4M-10MX4|(% style="text-align:center; vertical-align:middle" %)10m
827 -|(% style="text-align:center; vertical-align:middle" %)P-Z4-H28J4M-3MX4|(% style="text-align:center; vertical-align:middle" %)3m|(% rowspan="3" style="text-align:center; vertical-align:middle" %)(((
825 +|(% style="text-align:center; vertical-align:middle; width:214px" %)P-U3O1-H28J4M-5MX4|(% style="text-align:center; vertical-align:middle; width:92px" %)5m
826 +|(% style="text-align:center; vertical-align:middle; width:214px" %)P-U3O1-H28J4M-10MX4|(% style="text-align:center; vertical-align:middle; width:92px" %)10m
827 +|(% style="text-align:center; vertical-align:middle; width:214px" %)P-Z4-H28J4M-3MX4|(% style="text-align:center; vertical-align:middle; width:92px" %)3m|(% rowspan="3" style="text-align:center; vertical-align:middle" %)(((
828 828  [[image:image-20220611130038-5.png]]
829 829  
830 830  Suitable for VD2F drive connecting 110/130 flange lead wire motor
831 831  )))
832 -|(% style="text-align:center; vertical-align:middle" %)P-Z4-H28J4M-5MX4|(% style="text-align:center; vertical-align:middle" %)5m
833 -|(% style="text-align:center; vertical-align:middle" %)P-Z4-H28J4M-10MX4|(% style="text-align:center; vertical-align:middle" %)10m
834 -|(% style="text-align:center; vertical-align:middle" %)P-Z3O1-MC4S-3MX4|(% style="text-align:center; vertical-align:middle" %)3m|(% rowspan="3" style="text-align:center; vertical-align:middle" %)(((
832 +|(% style="text-align:center; vertical-align:middle; width:214px" %)P-Z4-H28J4M-5MX4|(% style="text-align:center; vertical-align:middle; width:92px" %)5m
833 +|(% style="text-align:center; vertical-align:middle; width:214px" %)P-Z4-H28J4M-10MX4|(% style="text-align:center; vertical-align:middle; width:92px" %)10m
834 +|(% style="text-align:center; vertical-align:middle; width:214px" %)P-Z3O1-MC4S-3MX4|(% style="text-align:center; vertical-align:middle; width:92px" %)3m|(% rowspan="3" style="text-align:center; vertical-align:middle" %)(((
835 835  [[image:image-20220611130043-6.png]]
836 836  
837 837  Suitable for VD2A drive connecting 60/80 flange lead wire motor
838 838  )))
839 -|(% style="text-align:center; vertical-align:middle" %)P-Z3O1-MC4S-5MX4|(% style="text-align:center; vertical-align:middle" %)5m
840 -|(% style="text-align:center; vertical-align:middle" %)P-Z3O1-MC4S-10MX4|(% style="text-align:center; vertical-align:middle" %)10m
841 -|(% style="text-align:center; vertical-align:middle" %)P-Z4-MC4S-3MX4|(% style="text-align:center; vertical-align:middle" %)3m|(% rowspan="3" style="text-align:center; vertical-align:middle" %)(((
839 +|(% style="text-align:center; vertical-align:middle; width:214px" %)P-Z3O1-MC4S-5MX4|(% style="text-align:center; vertical-align:middle; width:92px" %)5m
840 +|(% style="text-align:center; vertical-align:middle; width:214px" %)P-Z3O1-MC4S-10MX4|(% style="text-align:center; vertical-align:middle; width:92px" %)10m
841 +|(% style="text-align:center; vertical-align:middle; width:214px" %)P-Z4-MC4S-3MX4|(% style="text-align:center; vertical-align:middle; width:92px" %)3m|(% rowspan="3" style="text-align:center; vertical-align:middle" %)(((
842 842  [[image:image-20220611130048-7.png]]
843 843  
844 844  Suitable for VD2F drive connecting 60/80 flange lead wire motor
845 845  )))
846 -|(% style="text-align:center; vertical-align:middle" %)P-Z4-MC4S-5MX4|(% style="text-align:center; vertical-align:middle" %)5m
847 -|(% style="text-align:center; vertical-align:middle" %)P-Z4-MC4S-10MX4|(% style="text-align:center; vertical-align:middle" %)10m
846 +|(% style="text-align:center; vertical-align:middle; width:214px" %)P-Z4-MC4S-5MX4|(% style="text-align:center; vertical-align:middle; width:92px" %)5m
847 +|(% style="text-align:center; vertical-align:middle; width:214px" %)P-Z4-MC4S-10MX4|(% style="text-align:center; vertical-align:middle; width:92px" %)10m
848 848  
849 849  Table 11-1 Servo motor power cable exterior diagram
850 850