Changes for page 11 Appendix
Last modified by Theodore Xu on 2025/04/27 11:22
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -456,8 +456,8 @@ 456 456 457 457 Valid DI port logic: Servo motor is in mix control mode 458 458 ))) 459 -|(% style="text-align:center; vertical-align:middle" %)18|(% style="text-align:center; vertical-align:middle" %) 无|(% style="vertical-align:middle" %)None|(% style="vertical-align:middle" %)-460 -|(% style="text-align:center; vertical-align:middle" %)19|(% style="text-align:center; vertical-align:middle" %) 无|(% style="vertical-align:middle" %)None|(% style="vertical-align:middle" %)-459 +|(% style="text-align:center; vertical-align:middle" %)18|(% style="text-align:center; vertical-align:middle" %)None|(% style="vertical-align:middle" %)None|(% style="vertical-align:middle" %)- 460 +|(% style="text-align:center; vertical-align:middle" %)19|(% style="text-align:center; vertical-align:middle" %)None|(% style="vertical-align:middle" %)None|(% style="vertical-align:middle" %)- 461 461 |(% style="text-align:center; vertical-align:middle" %)20|(% style="text-align:center; vertical-align:middle" %)ENINPOS|(% style="vertical-align:middle" %)Internal multi-segment enable signal|(% style="vertical-align:middle" %)((( 462 462 Invalid DI port logic: Current running is not affected 463 463 ... ... @@ -787,64 +787,81 @@ 787 787 788 788 = **Wire** = 789 789 790 -|(% style="text-align:center; vertical-align:middle" %)**Wire model**|(% style="text-align:center; vertical-align:middle" %)**Wire length**|(% style="text-align:center; vertical-align:middle" %)**Wire exterior** 791 -|(% style="text-align:center; vertical-align:middle" %)P-Z3O1-R4M-3MX4|(% style="text-align:center; vertical-align:middle" %)3m|(% rowspan="3" style="text-align:center; vertical-align:middle" %)((( 790 + 791 +|**Wire model**|**Wire length**|**Wire exterior** 792 +|P-Z3O1-R4M-3MX4|3m|(% rowspan="3" %)((( 793 +[[image:image-20220611132646-1.jpeg]][[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml\wps7820.tmp.png]] 794 + 795 +Suitable for VD2A drive connecting 60/80 flange lead wire motor 796 +))) 797 +|P-Z3O1-R4M-5MX4|5m 798 +|P-Z3O1-R4M-10MX4|10m 799 +|P-U3O1-R4M-3MX4|3m|(% rowspan="3" %)((( 800 +[[image:image-20220611132653-2.jpeg]][[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml\wps7830.tmp.png]] 801 + 802 +Suitable for VD2B drive connecting 80 flange lead wire motor 803 +))) 804 +|P-U3O1-R4M-5MX4|5m 805 +|P-U3O1-R4M-10MX4|10m 806 + 807 +|(% style="text-align:center; vertical-align:middle; width:210px" %)**Wire model**|(% style="text-align:center; vertical-align:middle; width:96px" %)**Wire length**|(% style="text-align:center; vertical-align:middle" %)**Wire exterior** 808 +|(% style="text-align:center; vertical-align:middle; width:210px" %)P-Z3O1-R4M-3MX4|(% style="text-align:center; vertical-align:middle; width:96px" %)3m|(% rowspan="3" style="text-align:center; vertical-align:middle" %)((( 792 792 [[image:https://docs.we-con.com.cn/bin/download/Servo/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/11%20Appendix/WebHome/11-1%201.jpg?rev=1.1]] 793 793 794 794 Suitable for VD2A drive connecting 60/80 flange lead wire motor 795 795 ))) 796 -|(% style="text-align:center; vertical-align:middle" %)P-Z3O1-R4M-5MX4|(% style="text-align:center; vertical-align:middle" %)5m 797 -|(% style="text-align:center; vertical-align:middle" %)P-Z3O1-R4M-10MX4|(% style="text-align:center; vertical-align:middle" %)10m 798 -|(% style="text-align:center; vertical-align:middle" %)P-U3O1-R4M-3MX4|(% style="text-align:center; vertical-align:middle" %)3m|(% rowspan="3" style="text-align:center; vertical-align:middle" %)((( 799 -[[image:image-2022061112 5939-1.png]]813 +|(% style="text-align:center; vertical-align:middle; width:210px" %)P-Z3O1-R4M-5MX4|(% style="text-align:center; vertical-align:middle; width:96px" %)5m 814 +|(% style="text-align:center; vertical-align:middle; width:210px" %)P-Z3O1-R4M-10MX4|(% style="text-align:center; vertical-align:middle; width:96px" %)10m 815 +|(% style="text-align:center; vertical-align:middle; width:210px" %)P-U3O1-R4M-3MX4|(% style="text-align:center; vertical-align:middle; width:96px" %)3m|(% rowspan="3" style="text-align:center; vertical-align:middle" %)((( 816 +[[image:image-20220611130229-1.jpeg]] 800 800 801 801 Suitable for VD2B drive connecting 80 flange lead wire motor 802 802 ))) 803 -|(% style="text-align:center; vertical-align:middle" %)P-U3O1-R4M-5MX4|(% style="text-align:center; vertical-align:middle" %)5m 804 -|(% style="text-align:center; vertical-align:middle" %)P-U3O1-R4M-10MX4|(% style="text-align:center; vertical-align:middle" %)10m 820 +|(% style="text-align:center; vertical-align:middle; width:210px" %)P-U3O1-R4M-5MX4|(% style="text-align:center; vertical-align:middle; width:96px" %)5m 821 +|(% style="text-align:center; vertical-align:middle; width:210px" %)P-U3O1-R4M-10MX4|(% style="text-align:center; vertical-align:middle; width:96px" %)10m 805 805 806 -|(% style="text-align:center; vertical-align:middle" %)P-Z4-R4M-3MX4|(% style="text-align:center; vertical-align:middle" %)3m|(% rowspan="3" style="text-align:center; vertical-align:middle" %)((( 807 -[[image:image-20220611130 019-2.png]]823 +|(% style="text-align:center; vertical-align:middle; width:214px" %)P-Z4-R4M-3MX4|(% style="text-align:center; vertical-align:middle; width:92px" %)3m|(% rowspan="3" style="text-align:center; vertical-align:middle" %)((( 824 +[[image:image-20220611130233-2.jpeg]] 808 808 809 809 Suitable for VD2F drive connecting 40/60/80 flange lead wire motor 810 810 ))) 811 -|(% style="text-align:center; vertical-align:middle" %)P-Z4-R4M-5MX4|(% style="text-align:center; vertical-align:middle" %)5m 812 -|(% style="text-align:center; vertical-align:middle" %)P-Z4-R4M-10MX4|(% style="text-align:center; vertical-align:middle" %)10m 813 -|(% style="text-align:center; vertical-align:middle" %)P-Z3O1-H28J4M-3MX4|(% style="text-align:center; vertical-align:middle" %)3m|(% rowspan="3" style="text-align:center; vertical-align:middle" %)((( 828 +|(% style="text-align:center; vertical-align:middle; width:214px" %)P-Z4-R4M-5MX4|(% style="text-align:center; vertical-align:middle; width:92px" %)5m 829 +|(% style="text-align:center; vertical-align:middle; width:214px" %)P-Z4-R4M-10MX4|(% style="text-align:center; vertical-align:middle; width:92px" %)10m 830 +|(% style="text-align:center; vertical-align:middle; width:214px" %)P-Z3O1-H28J4M-3MX4|(% style="text-align:center; vertical-align:middle; width:92px" %)3m|(% rowspan="3" style="text-align:center; vertical-align:middle" %)((( 814 814 [[image:image-20220611130025-3.png]] 815 815 816 816 Suitable for VD2A drive connecting 110/130 flange lead wire motor 817 817 ))) 818 -|(% style="text-align:center; vertical-align:middle" %)P-Z3O1-H28J4M-5MX4|(% style="text-align:center; vertical-align:middle" %)5m 819 -|(% style="text-align:center; vertical-align:middle" %)P-Z3O1-H28J4M-10MX4|(% style="text-align:center; vertical-align:middle" %)10m 820 -|(% style="text-align:center; vertical-align:middle" %)P-U3O1-H28J4M-3MX4|(% style="text-align:center; vertical-align:middle" %)3m|(% rowspan="3" style="text-align:center; vertical-align:middle" %)((( 835 +|(% style="text-align:center; vertical-align:middle; width:214px" %)P-Z3O1-H28J4M-5MX4|(% style="text-align:center; vertical-align:middle; width:92px" %)5m 836 +|(% style="text-align:center; vertical-align:middle; width:214px" %)P-Z3O1-H28J4M-10MX4|(% style="text-align:center; vertical-align:middle; width:92px" %)10m 837 +|(% style="text-align:center; vertical-align:middle; width:214px" %)P-U3O1-H28J4M-3MX4|(% style="text-align:center; vertical-align:middle; width:92px" %)3m|(% rowspan="3" style="text-align:center; vertical-align:middle" %)((( 821 821 [[image:image-20220611130032-4.png]] 822 822 823 823 Suitable for VD2B drive connecting 110/130 flange lead wire motor 824 824 ))) 825 -|(% style="text-align:center; vertical-align:middle" %)P-U3O1-H28J4M-5MX4|(% style="text-align:center; vertical-align:middle" %)5m 826 -|(% style="text-align:center; vertical-align:middle" %)P-U3O1-H28J4M-10MX4|(% style="text-align:center; vertical-align:middle" %)10m 827 -|(% style="text-align:center; vertical-align:middle" %)P-Z4-H28J4M-3MX4|(% style="text-align:center; vertical-align:middle" %)3m|(% rowspan="3" style="text-align:center; vertical-align:middle" %)((( 842 +|(% style="text-align:center; vertical-align:middle; width:214px" %)P-U3O1-H28J4M-5MX4|(% style="text-align:center; vertical-align:middle; width:92px" %)5m 843 +|(% style="text-align:center; vertical-align:middle; width:214px" %)P-U3O1-H28J4M-10MX4|(% style="text-align:center; vertical-align:middle; width:92px" %)10m 844 +|(% style="text-align:center; vertical-align:middle; width:214px" %)P-Z4-H28J4M-3MX4|(% style="text-align:center; vertical-align:middle; width:92px" %)3m|(% rowspan="3" style="text-align:center; vertical-align:middle" %)((( 828 828 [[image:image-20220611130038-5.png]] 829 829 830 830 Suitable for VD2F drive connecting 110/130 flange lead wire motor 831 831 ))) 832 -|(% style="text-align:center; vertical-align:middle" %)P-Z4-H28J4M-5MX4|(% style="text-align:center; vertical-align:middle" %)5m 833 -|(% style="text-align:center; vertical-align:middle" %)P-Z4-H28J4M-10MX4|(% style="text-align:center; vertical-align:middle" %)10m 834 -|(% style="text-align:center; vertical-align:middle" %)P-Z3O1-MC4S-3MX4|(% style="text-align:center; vertical-align:middle" %)3m|(% rowspan="3" style="text-align:center; vertical-align:middle" %)((( 849 +|(% style="text-align:center; vertical-align:middle; width:214px" %)P-Z4-H28J4M-5MX4|(% style="text-align:center; vertical-align:middle; width:92px" %)5m 850 +|(% style="text-align:center; vertical-align:middle; width:214px" %)P-Z4-H28J4M-10MX4|(% style="text-align:center; vertical-align:middle; width:92px" %)10m 851 +|(% style="text-align:center; vertical-align:middle; width:214px" %)P-Z3O1-MC4S-3MX4|(% style="text-align:center; vertical-align:middle; width:92px" %)3m|(% rowspan="3" style="text-align:center; vertical-align:middle" %)((( 835 835 [[image:image-20220611130043-6.png]] 836 836 837 837 Suitable for VD2A drive connecting 60/80 flange lead wire motor 838 838 ))) 839 -|(% style="text-align:center; vertical-align:middle" %)P-Z3O1-MC4S-5MX4|(% style="text-align:center; vertical-align:middle" %)5m 840 -|(% style="text-align:center; vertical-align:middle" %)P-Z3O1-MC4S-10MX4|(% style="text-align:center; vertical-align:middle" %)10m 841 -|(% style="text-align:center; vertical-align:middle" %)P-Z4-MC4S-3MX4|(% style="text-align:center; vertical-align:middle" %)3m|(% rowspan="3" style="text-align:center; vertical-align:middle" %)((( 856 +|(% style="text-align:center; vertical-align:middle; width:214px" %)P-Z3O1-MC4S-5MX4|(% style="text-align:center; vertical-align:middle; width:92px" %)5m 857 +|(% style="text-align:center; vertical-align:middle; width:214px" %)P-Z3O1-MC4S-10MX4|(% style="text-align:center; vertical-align:middle; width:92px" %)10m 858 +|(% style="text-align:center; vertical-align:middle; width:214px" %)P-Z4-MC4S-3MX4|(% style="text-align:center; vertical-align:middle; width:92px" %)3m|(% rowspan="3" style="text-align:center; vertical-align:middle" %)((( 842 842 [[image:image-20220611130048-7.png]] 843 843 844 844 Suitable for VD2F drive connecting 60/80 flange lead wire motor 845 845 ))) 846 -|(% style="text-align:center; vertical-align:middle" %)P-Z4-MC4S-5MX4|(% style="text-align:center; vertical-align:middle" %)5m 847 -|(% style="text-align:center; vertical-align:middle" %)P-Z4-MC4S-10MX4|(% style="text-align:center; vertical-align:middle" %)10m 863 +|(% style="text-align:center; vertical-align:middle; width:214px" %)P-Z4-MC4S-5MX4|(% style="text-align:center; vertical-align:middle; width:92px" %)5m 864 +|(% style="text-align:center; vertical-align:middle; width:214px" %)P-Z4-MC4S-10MX4|(% style="text-align:center; vertical-align:middle; width:92px" %)10m 848 848 849 849 Table 11-1 Servo motor power cable exterior diagram 850 850