Changes for page 11 Appendix
Last modified by Theodore Xu on 2025/04/27 11:22
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -382,14 +382,14 @@ 382 382 383 383 == **Group P12 Communication parameters** == 384 384 385 -|=(% rowspan="2" scope="row" style="text-align: center; vertical-align: middle; width: 15 9px;" %)**Function code**|=(% rowspan="2" style="text-align:center; vertical-align:middle; width:240px" %)**Name**|=(% rowspan="2" style="text-align:center; vertical-align:middle; width:189px" %)**Setting method**|=(% rowspan="2" style="text-align:0px;" %)**Effective time**|=(% rowspan="2" style="text-align:08px;" %)**Default**|=(% rowspan="2" style="text-align:; width: 157px;" %)**Range**|=(% rowspan="2" style="text-align:; width: 118px;" %)**Unit**|=(% colspan="2" style="text-align:87px;" %)**Modbus address**|=(% rowspan="2" style="text-align:30px;" %)**Data type**386 -|=(% style="text-align: center; vertical-align: middle; width: 103px;" %)**Hexadecimal**|=(% style="text-align:5px;" %)**Decimal**387 -|=(% style="text-align: center; vertical-align: middle; width: 153px;" %)__P12-01__|(% style="text-align:center; vertical-align:middle; width:319px" %)Servo address|(% style="text-align:center; vertical-align:middle; width:223px" %)Operation setting|(% style="text-align:center; vertical-align:middle; width:216px" %)Effective immediately|(% style="text-align:center; vertical-align:middle; width:1 02px" %)1|(% style="text-align:center; vertical-align:middle; width:88px" %)1 to 247|(% style="text-align:center; vertical-align:middle; width:61px" %)-|(% style="text-align:center; vertical-align:middle" %)0x0C01|(% style="text-align:center; vertical-align:middle; width:68px" %)3073|(% style="text-align:center; vertical-align:middle; width:127px" %)16-bit388 -|=(% style="text-align: center; vertical-align: middle; width: 153px;" %)__P12-02__|(% style="text-align:center; vertical-align:middle; width:319px" %)Baud rate|(% style="text-align:center; vertical-align:middle; width:223px" %)Operation setting|(% style="text-align:center; vertical-align:middle; width:216px" %)Effective immediately|(% style="text-align:center; vertical-align:middle; width:1 02px" %)2|(% style="text-align:center; vertical-align:middle; width:88px" %)0 to 5|(% style="text-align:center; vertical-align:middle; width:61px" %)-|(% style="text-align:center; vertical-align:middle" %)0x0C02|(% style="text-align:center; vertical-align:middle; width:68px" %)3074|(% style="text-align:center; vertical-align:middle; width:127px" %)16-bit389 -|=(% style="text-align: center; vertical-align: middle; width: 153px;" %)__P12-03__|(% style="text-align:center; vertical-align:middle; width:319px" %)Serial data format|(% style="text-align:center; vertical-align:middle; width:223px" %)Operation setting|(% style="text-align:center; vertical-align:middle; width:216px" %)Effective immediately|(% style="text-align:center; vertical-align:middle; width:1 02px" %)0|(% style="text-align:center; vertical-align:middle; width:88px" %)0 to 3|(% style="text-align:center; vertical-align:middle; width:61px" %)-|(% style="text-align:center; vertical-align:middle" %)0x0C03|(% style="text-align:center; vertical-align:middle; width:68px" %)3075|(% style="text-align:center; vertical-align:middle; width:127px" %)16-bit390 -|=(% style="text-align: center; vertical-align: middle; width: 153px;" %)__P12-04__|(% style="text-align:center; vertical-align:middle; width:319px" %)Modbus communication data is written into EEPROM|(% style="text-align:center; vertical-align:middle; width:223px" %)Operation setting|(% style="text-align:center; vertical-align:middle; width:216px" %)Effective immediately|(% style="text-align:center; vertical-align:middle; width:1 02px" %)0|(% style="text-align:center; vertical-align:middle; width:88px" %)0 to 1|(% style="text-align:center; vertical-align:middle; width:61px" %)-|(% style="text-align:center; vertical-align:middle" %)0x0C04|(% style="text-align:center; vertical-align:middle; width:68px" %)3076|(% style="text-align:center; vertical-align:middle; width:127px" %)16-bit391 -|=(% style="text-align: center; vertical-align: middle; width: 153px;" %)__P12-05__|(% style="text-align:center; vertical-align:middle; width:319px" %)RS422/RS485 function selection|(% style="text-align:center; vertical-align:middle; width:223px" %)Operation setting|(% style="text-align:center; vertical-align:middle; width:216px" %)Effective immediately|(% style="text-align:center; vertical-align:middle; width:1 02px" %)0|(% style="text-align:center; vertical-align:middle; width:88px" %)0 to 1|(% style="text-align:center; vertical-align:middle; width:61px" %)-|(% style="text-align:center; vertical-align:middle" %)0x0C05|(% style="text-align:center; vertical-align:middle; width:68px" %)3077|(% style="text-align:center; vertical-align:middle; width:127px" %)16-bit392 -|=(% style="text-align: center; vertical-align: middle; width: 153px;" %)__P12-06__|(% style="text-align:center; vertical-align:middle; width:319px" %)Modbus 32-bit variable high and low byte order|(% style="text-align:center; vertical-align:middle; width:223px" %)Operation setting|(% style="text-align:center; vertical-align:middle; width:216px" %)Effective immediately|(% style="text-align:center; vertical-align:middle; width:1 02px" %)0|(% style="text-align:center; vertical-align:middle; width:88px" %)0 to 1|(% style="text-align:center; vertical-align:middle; width:61px" %)385 +|=(% rowspan="2" scope="row" style="text-align: center; vertical-align: middle; width: 153px;" %)**Function code**|(% rowspan="2" style="text-align:center; vertical-align:middle; width:319px" %)**Name**|(% rowspan="2" style="text-align:center; vertical-align:middle; width:223px" %)**Setting method**|(% rowspan="2" style="text-align:center; vertical-align:middle; width:216px" %)**Effective time**|(% rowspan="2" style="text-align:center; vertical-align:middle; width:121px" %)**Default**|(% rowspan="2" style="text-align:center; vertical-align:middle" %)**Range**|(% rowspan="2" style="text-align:center; vertical-align:middle" %)**Unit**|(% colspan="2" style="text-align:center; vertical-align:middle; width:199px" %)**Modbus address**|(% rowspan="2" style="text-align:center; vertical-align:middle; width:127px" %)**Data type** 386 +|=(% style="text-align: center; vertical-align: middle;" %)**Hexadecimal**|(% style="text-align:center; vertical-align:middle; width:68px" %)**Decimal** 387 +|=(% style="text-align: center; vertical-align: middle; width: 153px;" %)__P12-01__|(% style="text-align:center; vertical-align:middle; width:319px" %)Servo address|(% style="text-align:center; vertical-align:middle; width:223px" %)Operation setting|(% style="text-align:center; vertical-align:middle; width:216px" %)Effective immediately|(% style="text-align:center; vertical-align:middle; width:121px" %)1|(% style="text-align:center; vertical-align:middle" %)1 to 247|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)0x0C01|(% style="text-align:center; vertical-align:middle; width:68px" %)3073|(% style="text-align:center; vertical-align:middle; width:127px" %)16-bit 388 +|=(% style="text-align: center; vertical-align: middle; width: 153px;" %)__P12-02__|(% style="text-align:center; vertical-align:middle; width:319px" %)Baud rate|(% style="text-align:center; vertical-align:middle; width:223px" %)Operation setting|(% style="text-align:center; vertical-align:middle; width:216px" %)Effective immediately|(% style="text-align:center; vertical-align:middle; width:121px" %)2|(% style="text-align:center; vertical-align:middle" %)0 to 5|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)0x0C02|(% style="text-align:center; vertical-align:middle; width:68px" %)3074|(% style="text-align:center; vertical-align:middle; width:127px" %)16-bit 389 +|=(% style="text-align: center; vertical-align: middle; width: 153px;" %)__P12-03__|(% style="text-align:center; vertical-align:middle; width:319px" %)Serial data format|(% style="text-align:center; vertical-align:middle; width:223px" %)Operation setting|(% style="text-align:center; vertical-align:middle; width:216px" %)Effective immediately|(% style="text-align:center; vertical-align:middle; width:121px" %)0|(% style="text-align:center; vertical-align:middle" %)0 to 3|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)0x0C03|(% style="text-align:center; vertical-align:middle; width:68px" %)3075|(% style="text-align:center; vertical-align:middle; width:127px" %)16-bit 390 +|=(% style="text-align: center; vertical-align: middle; width: 153px;" %)__P12-04__|(% style="text-align:center; vertical-align:middle; width:319px" %)Modbus communication data is written into EEPROM|(% style="text-align:center; vertical-align:middle; width:223px" %)Operation setting|(% style="text-align:center; vertical-align:middle; width:216px" %)Effective immediately|(% style="text-align:center; vertical-align:middle; width:121px" %)0|(% style="text-align:center; vertical-align:middle" %)0 to 1|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)0x0C04|(% style="text-align:center; vertical-align:middle; width:68px" %)3076|(% style="text-align:center; vertical-align:middle; width:127px" %)16-bit 391 +|=(% style="text-align: center; vertical-align: middle; width: 153px;" %)__P12-05__|(% style="text-align:center; vertical-align:middle; width:319px" %)RS422/RS485 function selection|(% style="text-align:center; vertical-align:middle; width:223px" %)Operation setting|(% style="text-align:center; vertical-align:middle; width:216px" %)Effective immediately|(% style="text-align:center; vertical-align:middle; width:121px" %)0|(% style="text-align:center; vertical-align:middle" %)0 to 1|(% style="text-align:center; vertical-align:middle" %)-|(% style="text-align:center; vertical-align:middle" %)0x0C05|(% style="text-align:center; vertical-align:middle; width:68px" %)3077|(% style="text-align:center; vertical-align:middle; width:127px" %)16-bit 392 +|=(% style="text-align: center; vertical-align: middle; width: 153px;" %)__P12-06__|(% style="text-align:center; vertical-align:middle; width:319px" %)Modbus 32-bit variable high and low byte order|(% style="text-align:center; vertical-align:middle; width:223px" %)Operation setting|(% style="text-align:center; vertical-align:middle; width:216px" %)Effective immediately|(% style="text-align:center; vertical-align:middle; width:121px" %)0|(% style="text-align:center; vertical-align:middle" %)0 to 1|(% style="text-align:center; vertical-align:middle" %)|(% style="text-align:center; vertical-align:middle" %)0x0C06|(% style="text-align:center; vertical-align:middle; width:68px" %)3078|(% style="text-align:center; vertical-align:middle; width:127px" %)16-bit 393 393 394 394 == **Group P13 Virtual input terminal** == 395 395