Changes for page VD2 SA Series
Last modified by Iris on 2026/04/15 09:18
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Wecon1 +XWiki.Iris - Content
-
... ... @@ -25,24 +25,30 @@ 25 25 = **User Manual Version History** = 26 26 27 27 28 -|=Date|=((( 29 -Changed 30 - 31 -Version 32 -)))|=Change content|=Applicable models and firmware versions 28 +|**Date**|**Version**|**Changes**|**Applicable models and firmware reversions** 33 33 |2021.12|A1.0|First release version|((( 34 34 VD2-0□□SA1G model: V1.10, V1.12 35 35 36 -VD2F-0□□SA1P model: V1.0032 +VD2F-0□□SA1P model: V1.00 37 37 ))) 38 38 |2022.03|A1.1|((( 39 -Chapter 2 Updating the servo driver naming, updating motor model table.35 +Chapter 2 40 40 41 - Chapter 3Updatingmotor dimensiondrawingand dimensiontable37 +Updating the servo driver naming. 42 42 43 - Chapter 6 Add new section 6.6.4 "Speed Limit in Speed Mode", updatingrelevant parameter content forfirmwareupgrade39 +Updating motor model table. 44 44 45 -Chapter 11 Add the description of the scope of application of the cable 41 +Chapter 3 42 + 43 +Updating motor dimension drawing and dimension table 44 + 45 +Chapter 6 46 + 47 +Add new section 6.4.4 "Speed limit in speed mode", updating relevant parameter content for firmware upgrade 48 + 49 +Chapter 11 50 + 51 +Add the description of the scope of application of the cable 46 46 )))|((( 47 47 VD2-0□□SA1G model: Add V1.13 48 48 ... ... @@ -49,21 +49,41 @@ 49 49 VD2F-0□□SA1P model: Add V1.01 and V1.02 50 50 ))) 51 51 |2022.04|A1.2|((( 52 -Chapter 2 Updating section 2.1 “Servo Drive Specifications”58 +Chapter 2 53 53 54 - Chapter 4Updating section4.1“Main CircuitWiring”,updatingsection 4.5 “Communicationsignal wiring”60 +Updating section 2.1.3 “Servo drive specifications” 55 55 56 -Chapter 5 Updating section 5.3.3 “Restore Factory Settings” process and instructions62 +Chapter 4 57 57 58 - Chapter 6Updating section6.6“Absolute valuesystem”64 +Updating section 4.1 “Main circuit wiring”. 59 59 60 - Chapter 7Updating section7.3“Gainadjustment”renderings66 +Updating section 4.5 “Communication signal wiring” 61 61 62 -Chapter 8 Updating section 8.2.5“Communication Example”68 +Chapter 5 63 63 64 - Chapter 10Updating section10.2.2“Fault and WarningCodeTable”, 10.2.3 addsection10.3 “Troubleshooting”70 +Updating section 5.3.3 “Restore factory settings” process and instructions 65 65 66 -Chapters 9 and 11 adjust relevant parameters for firmware upgrades 72 +Chapter 6 73 + 74 +Updating section 6.6 “Absolute value system” 75 + 76 +Chapter 7 77 + 78 +Updating section 7.3 “Gain adjustment” renderings 79 + 80 +Chapter 8 81 + 82 +Updating section 8.2.5 “Communication example” 83 + 84 +Chapter 10 85 + 86 +Updating section 10.2.2 “Fault and warning code table”. 87 + 88 +Add section 10.3 “Troubleshooting” 89 + 90 +Chapters 9 and 11 91 + 92 +Adjust relevant parameters for firmware upgrades 67 67 )))|((( 68 68 VD2-0□□SA1G model: 69 69 ... ... @@ -71,22 +71,30 @@ 71 71 72 72 VD2F-0□□SA1P model: 73 73 74 - V1.01, V1.02100 +V1.01, V1.02 75 75 76 -Add VD2-021TA1G model: 77 - 78 -V1.01 102 +Add VD2-021TA1G model:V1.01 79 79 ))) 80 80 |2022.11|V2.0|((( 81 81 Chapter 4 82 82 83 -Modify section 4.4.1 “VD2A, VD2F pin wiring diagram” Add section 4.4.1 “VD2-0xxSA1H driver DIDO pin distribution”. Add section 4.4.2 “VD2-0xxSA1H mode wiring diagram” Add section 4.4.5 “VD2-0xxSA1H DIDO signal”107 +Modify section 4.4.1 “VD2A, VD2F pin wiring diagram” 84 84 109 +Add section 4.4.1 “vVD2-0xxsa1h driver dido pin distribution”. Add section 4.4.2 “VD2-0xxSA1H mode wiring diagram” 110 + 111 +Add section 4.4.5 “VD2-0xxSA1H dido signal” 112 + 85 85 Chapter 7 86 86 87 -Updating section 7.3.4 “Model TrackingControlFunction” Updating section 7.3.5 “GainSwitchingFunction”Updating section 7.4.3 “Low Frequency Vibration Suppression Function” Updating section 7.4.4 “Type A Vibration Suppression Function”115 +Updating section 7.3.4 “Model tracking control function” Updating section 7.3.5 “Gain switching function” 88 88 89 -Chapters 9 and 11 adjust relevant parameters for new functions such as “model tracking control” 117 +Updating section 7.4.3 “Low frequency vibration suppression function” 118 + 119 +Updating section 7.4.4 “Type a vibration suppression function” 120 + 121 +Chapters 9 and 11 122 + 123 +Adjust relevant parameters for new functions such as “Model tracking control” 90 90 )))|((( 91 91 VD2-0□□SA1H model: 92 92 ... ... @@ -95,46 +95,60 @@ 95 95 |2023.05|V2.1|((( 96 96 Chapter 6 97 97 98 -Updating section 6.17 “Shutdown deceleration time” setting feature.Updating section 6.63 “P10-6 Multi-turn Absolute Encoder Reset” and “P10-8: Multi-turn Absolute Encoder Origin Offset Compensation” Updating section 6.64 "P00-31 Encoder Read and Write Verification Abnormal Threshold Setting"132 +Updating section 6.17 “Shutdown deceleration time” Setting feature. 99 99 134 +Updating section 6.63 “P10-6 multi-turn absolute encoder reset” And “P10-8: Multi-turn absolute encoder origin offset compensation” 135 + 136 +Updating section 6.64 "P00-31 encoder read and write verification abnormal threshold setting" 137 + 100 100 Chapter 10 101 101 102 -Add “Er.43 DriveOverloadFail”and parameter content.Add “A80 Drive Overload Alarm” Modify “A91 Parameter Modification too Frequent Warning” trigger condition. Add temporary solution for "A93 encoder read and write verification abnormal frequency is too high"140 +Add “Er.43 drive overload fail” And parameter content. 103 103 104 -Chapters 9 and 11 adjust relevant parameters for new functions such as “Estop shutdown deceleration time” 105 -)))|Add V1.18 firmware 142 +Add “A80 drive overpower warning” 143 + 144 +Modify “A91 parameter modification too frequent warning” Trigger condition. 145 + 146 +Add temporary solution for "A93 encoder read and write verification abnormal frequency is too high" 147 + 148 +Chapters 9 and 11 149 + 150 +Adjust relevant parameters for new functions such as “Estop shutdown deceleration time” 151 +)))|((( 152 +Add V1.18 firmware 153 +))) 106 106 |2024.01|V2.2|((( 107 107 Chapter 2 108 108 109 -Update 2.1.1 "Servo DriveModelNamingRules"157 +Update 2.1.1 "Servo drive model naming rules" 110 110 111 -Add 2.1.1 "V D2LDriveAppearance andNameplate"and "VD2CDriveAppearance andNameplate"159 +Add 2.1.1 "Vd2l drive appearance and nameplate" And "VD2C drive appearance and nameplate" 112 112 113 -Add 2.1.2 "Composition of VD2L Drive"and "Composition of VD2CDriveAppearance"161 +Add 2.1.2 "Composition of VD2L drive" And "Composition of VD2C drive appearance" 114 114 115 -Add 2.1.3 "Electrical Specifications forVD2LDrives"and "ElectricalSpecifications for VD2CDrives"163 +Add 2.1.3 "Electrical specifications for vd2l drives" And "Electrical specifications for VD2C drives" 116 116 117 -Add 2.2.2 "Motor ( WireType)CompositionDiagram"165 +Add 2.2.2 "Motor (wire type) composition diagram" 118 118 119 119 Chapter 3 120 120 121 -Add 3.1.1 "VD2L DriveInstallationDimensionDiagram"and "VD2CDriveInstallationDimensionDiagram"169 +Add 3.1.1 "VD2L drive installation dimension diagram" And "VD2C drive installation dimension diagram" 122 122 123 -Add 3.1.4 "VD2L DriveMinimumInstallationDimensionDiagram"and "VD2CDriveMinimumInstallationDimensionDiagram"171 +Add 3.1.4 "VD2L drive minimum installation dimension diagram" And "VD2C drive minimum installation dimension diagram" 124 124 125 -Add 3.1.4 "VD2L DriveParallelInstallationDimensionDiagram" and "VD2CDriveParallelInstallationDimensionDiagram"173 +Add 3.1.4 "VD2L drive parallel installation dimension diagram" and "VD2C drive parallel installation dimension diagram" 126 126 127 127 Chapter 4 128 128 129 -Add 4.1.1 "VD2L ServoDriveMainCircuitTerminalArrangement and VD2CServoDriveMainCircuitTerminalArrangement"177 +Add 4.1.1 "VD2L servo drive main circuit terminal arrangement and VD2C servo drive main circuit terminal arrangement" 130 130 131 -Add 4.1.2 "VD2L drive single-phase 220 Vmain circuit wiring" and "VD2C drivesingle-phase220Vmain circuit wiring"179 +Add 4.1.2 "VD2L drive single-phase 220v main circuit wiring" and "VD2C drive three-phase 380V main circuit wiring" 132 132 133 -Add 4.3 "Absolute EncoderCableConnector (ConnectorType)Pin-out andEncoderCablePinConnection"181 +Add 4.3 "Absolute encoder cable connector (connector type) pin-out and encoder cable pin connection" 134 134 135 135 Add 4.4.1 "Pin-out of VD2L servo drive control input and output (CN2 interface)" 136 136 137 -Add 4.4.1 "VD2L drive single phase 220Vmain circuit wiring"185 +Add 4.4.1 "VD2L drive single-phase 220V main circuit wiring" 138 138 139 139 Add 4.4.2 "VD2L drive position pulse mode wiring" 140 140 ... ... @@ -146,37 +146,37 @@ 146 146 147 147 Add 4.4.5 "VD2L drive digital output circuit" 148 148 149 -Add 4.5.1 "VD2L drive VD2L type and PC connection method"197 +Add 4.5.1 "VD2L drive VD2L type and PC connection method" 150 150 151 151 Chapter 6 152 152 153 -Revise 6.2 "P0-01 ParameterTable 6-11ControlModeParameterDetails"201 +Revise 6.2 "P0-01 parameter table 6-11 control mode parameter details" 154 154 155 -Revise 6.2 "Table 6-1 5 PositionPulseTypeSelectionParameterDetails"203 +Revise 6.2 "Table 6-16 position pulse type selection parameter details" 156 156 157 157 Revise 6.2 "Add VD2L P0-14 parameters" 158 158 159 -Add 6.2.6 "VD2L-0xx SA1Ppulse signalDOoutput function"207 +Add 6.2.6 "VD2L-0xxsa1p pulse signal do output function" 160 160 161 161 Revise 6.2.6 "Comments on P6-28, P6-30 and P6-32" 162 162 163 163 Revise 6.3.1 "Comments on supported models of P5-03, P5-04, P5-01 and P5-02" 164 164 165 -Revise 6.4.1 "Unsupported models for P1-07"213 +Revise 6.4.1 "Unsupported models for p1-07" 166 166 167 -Revise 6.4.1 "Table 6-4 5AI_1 related parameter detail "215 +Revise 6.4.1 "Table 6-46 AI_1 related parameter detail " 168 168 169 -Revise 6.4.3 "Comments on P1-14"217 +Revise 6.4.3 "Comments on p1-14" 170 170 171 -Revise 6.4.3 "Comments on Table 6-52 MixedControlModeParameters"219 +Revise 6.4.3 "Comments on table 6-53 mixed control mode parameters" 172 172 173 173 Revise 6.6.4 "Functions of P0-30" 174 174 175 175 Chapter 7 176 176 177 -Revise 7.4.3 "Applicable Models forRelatedParameters ofLowFrequencyVibrationSuppressionFunction"225 +Revise 7.4.3 "Applicable models for related parameters of low frequency vibration suppression function" 178 178 179 -Revise 7.4.4 "Applicable models for RelatedParameters ofTypeAVibrationSuppressionFunction"227 +Revise 7.4.4 "Applicable models for related parameters of type a vibration suppression function" 180 180 181 181 Chapter 9 182 182 ... ... @@ -192,25 +192,28 @@ 192 192 193 193 Chapter 10 194 194 195 -Add the function introduction of E R.45 drive stall over temperature protection.243 +Add the function introduction of Er.45 drive stall over temperature protection. 196 196 197 -Revise ER.27Not clearable properties;245 +Revise er.27 not clearable properties; 198 198 )))|((( 199 - UpdateV1.20 firmware247 + 200 200 249 +Update V1.20 firmware 250 + 201 201 Add VD2L series model 202 202 203 -Add VD2 -050TA1Gmodel253 +Add VD2C series model 204 204 ))) 205 -|((( 206 -2024.09 207 -)))|((( 208 -V2.3 209 -)))|((( 210 -Chapter 2 Amend subsection 2.13 “Basic specifications” 255 +|2024.09|V2.3|((( 256 +Chapter 2 211 211 212 - Chapter 3Adda newsubsection3.13 “Installationenvironmentforservo drives”258 +Amend subsection 2.13 “Basic specifications” 213 213 260 + 261 +Chapter 3 262 + 263 +Add a new subsection 3.13 “Installation environment for servo drives” 264 + 214 214 Addition of subsection 3.23 “Installation environment for servomotors” 215 215 )))|((( 216 216 New changes to the description of environmental conditions ... ... @@ -218,29 +218,46 @@ 218 218 |2024.12|V2.4|((( 219 219 Chapter 6 220 220 221 -Added section 6.8 “Home ReturnMode (HM)”;272 +Added section 6.8 “Home return mode (HM)” 222 222 223 223 Chapter 9 224 224 225 -Revised the content of "P00-04 FunctionCode";276 +Revised the content of "P00-04 function code" 226 226 227 -Added "Group P01: P01-39; P01-40; P01-41; P01-42; P01-43; P01-44 ";278 +Added "Group p01: P01-39; P01-40; P01-41; P01-42; P01-43; P01-44 " 228 228 229 -Added "U0 Group: U0-59 bus voltage historical maximum andU0-60 average power historical maximum;280 +Added "U0 group: U0-59 bus voltage historical maximum and u0-60 average power historical maximum 230 230 231 231 Chapter 10 232 232 233 -Section 10.3, added E R.19SoftwareOvercurrent;284 +Section 10.3, added “Er.19 software overcurrent” 234 234 )))|((( 235 235 Added VD2 series V1.22 firmware 236 236 237 237 Added VD2L V1.02 firmware 238 238 ))) 290 +|2026.01|V3.0|((( 291 +Chapter 9: 239 239 293 +Add [P01-20] Software overcurrent detection window 294 + 295 +[P0-33] Multi-turn encoder undervoltage fault auto clear 296 + 297 +[P02-40], [P02-41], [P02-42], [P02-43] Gravity compensation related function codes 298 + 299 +[P02-47], [P02-48, ], [P02-49], [P02-50] Quadrant protrusion compensation related function codes 300 + 301 +[P07] Group Multi-position function code updates & Adjustments 302 +)))|((( 303 +Added VD2 series V1.24 firmware 304 + 305 +Added VD2L V1.03 firmware 306 +))) 307 + 240 240 The following table lists the servo driver models and supported firmware. 241 241 242 -| |||**Supported models**|**Corresponding model**|**Voltage**|**Supported firmware**243 -|(% rowspan="18" %) |(% rowspan="18" %) |(% colspan="1" rowspan="18"%)**Wecon VD2SA series servo drives manual**|VD2-010SA1G|(% rowspan="2" %)VD2A type|(% rowspan="12" %)220V|(% rowspan="7" %)(((310 +|(% style="width:199px" %) |(% style="width:264px" %)**Supported models**|(% style="width:300px" %)**Corresponding model**|**Voltage**|**Supported firmware** 311 +|(% rowspan="18" style="width:199px" %)**Wecon VD2SA series servo drives manual**|(% style="width:264px" %)VD2-010SA1G|(% rowspan="2" style="width:300px" %)VD2A type|(% rowspan="12" %)220V|(% rowspan="7" %)((( 244 244 V1.10 245 245 246 246 V1.12 ... ... @@ -264,14 +264,18 @@ 264 264 V1.21 265 265 266 266 V1.22 335 + 336 +V1.23 337 + 338 +V1.24 267 267 ))) 268 -|VD2-014SA1G 269 -|VD2-016SA1G|(% rowspan="5" %)VD2 B type270 -|VD2-019SA1G 271 -|VD2-021SA1G 272 -|VD2-025SA1GF 273 -|VD2-030SA1G 274 -|VD2F-003SA1P|(% rowspan="3" %)VD2F|(% rowspan="3" %)((( 340 +|(% style="width:264px" %)VD2-014SA1G 341 +|(% style="width:264px" %)VD2-016SA1G|(% rowspan="5" style="width:300px" %)VD2B type 342 +|(% style="width:264px" %)VD2-019SA1G 343 +|(% style="width:264px" %)VD2-021SA1G 344 +|(% style="width:264px" %)VD2-025SA1GF 345 +|(% style="width:264px" %)VD2-030SA1G 346 +|(% style="width:264px" %)VD2F-003SA1P|(% rowspan="3" style="width:300px" %)VD2F|(% rowspan="3" %)((( 275 275 V1.00 276 276 277 277 V1.01 ... ... @@ -291,20 +291,24 @@ 291 291 V1.21 292 292 293 293 V1.22 366 + 367 +V1.23 368 + 369 +V1.24 294 294 ))) 295 -|VD2F-010SA1P 296 -|VD2F-014SA1P 297 -|VD2L-010SA1P|(% rowspan="2" %)VD2L|(% rowspan="2" %)((( 371 +|(% style="width:264px" %)VD2F-010SA1P 372 +|(% style="width:264px" %)VD2F-014SA1P 373 +|(% style="width:264px" %)VD2L-010SA1P|(% rowspan="2" style="width:300px" %)VD2L|(% rowspan="2" %)((( 298 298 V1.00 299 299 300 300 V1.01 301 301 302 302 V1.02 379 + 380 +V1.03 303 303 ))) 304 -|VD2L-014SA1P 305 -|((( 306 -VD2-016TA1G 307 -)))|(% colspan="1" rowspan="3" %)VD2 B type|(% colspan="1" rowspan="6" %)380V|(% colspan="1" rowspan="3" %)((( 382 +|(% style="width:264px" %)VD2L-014SA1P 383 +|(% style="width:264px" %)VD2-016TA1G|(% rowspan="3" style="width:300px" %)VD2B type|(% rowspan="6" %)380V|(% rowspan="3" %)((( 308 308 V1.01 309 309 310 310 V1.17 ... ... @@ -318,17 +318,23 @@ 318 318 V1.21 319 319 320 320 V1.22 397 + 398 +V1.23 399 + 400 +V1.24 321 321 ))) 322 -|((( 323 -VD2-019TA1G 324 -))) 325 -|VD2-021TA1G 326 -|VD2-030TA1G|(% rowspan="3" %)VD2 C type|(% rowspan="3" %)((( 402 +|(% style="width:264px" %)VD2-019TA1G 403 +|(% style="width:264px" %)VD2-021TA1G 404 +|(% style="width:264px" %)VD2-030TA1G|(% rowspan="3" style="width:300px" %)VD2C type|(% rowspan="3" %)((( 327 327 V1.20 328 328 329 329 V1.21 330 330 331 331 V1.22 410 + 411 +V1.23 412 + 413 +V1.24 332 332 ))) 333 -|VD2-040TA1G 334 -|VD2-050TA1G 415 +|(% style="width:264px" %)VD2-040TA1G 416 +|(% style="width:264px" %)VD2-050TA1G