Changes for page VD2 SA Series
Last modified by Mora Zhou on 2025/04/02 15:17
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Jim1 +XWiki.Mora - Content
-
... ... @@ -16,7 +16,7 @@ 16 16 (% class="warning" %)|[[image:image-20220923133747-2.png||height="34" width="130"]] 17 17 |The danger caused by failure to operate as required may result in moderate or minor injuries, and equipment damage. 18 18 19 -= **User Manual ChangeRecord** =19 += **User Manual Version History** = 20 20 21 21 22 22 |=Date|=((( ... ... @@ -87,13 +87,112 @@ 87 87 88 88 Chapter 10 add “Er.43 Drive Overload Fail” and parameter content. Add “A80 Drive Overload Alarm” Modify “A91 Parameter Modification too Frequent Warning” trigger condition. Add temporary solution for "A93 encoder read and write verification abnormal frequency is too high" 89 89 90 -Chapters 9 and 11 adjust relevant parameters for new functions such as “Estop shutdown deceleration time” 90 +Chapters 9 and 11 adjust relevant parameters for new functions such as “Estop shutdown deceleration time” 91 91 )))|Add V1.18 firmware 92 +|2024.01|V2.2|((( 93 +Chapter 2 92 92 95 +Update 2.1.1 "Servo Drive Model Naming Rules" 96 + 97 +Add 2.1.1 "VD2L Drive Appearance and Nameplate" and "VD2C Drive Appearance and Nameplate" 98 + 99 +Add 2.1.2 "Composition of VD2L Drive" and "Composition of VD2C Drive Appearance" 100 + 101 +Add 2.1.3 "Electrical Specifications for VD2L Drives" and "Electrical Specifications for VD2C Drives" 102 + 103 +Add 2.2.2 "Motor (Wire Type) Composition Diagram" 104 + 105 +Chapter 3 106 + 107 +Add 3.1.1 "VD2L Drive Installation Dimension Diagram" and "VD2C Drive Installation Dimension Diagram" 108 + 109 +Add 3.1.4 "VD2L Drive Minimum Installation Dimension Diagram" and "VD2C Drive Minimum Installation Dimension Diagram" 110 + 111 +Add 3.1.4 "VD2L Drive Parallel Installation Dimension Diagram" and "VD2C Drive Parallel Installation Dimension Diagram" 112 + 113 +Chapter 4 114 + 115 +Add 4.1.1 "VD2L Servo Drive Main Circuit Terminal Arrangement and VD2C Servo Drive Main Circuit Terminal Arrangement" 116 + 117 +Add 4.1.2 "VD2L drive single-phase 220V main circuit wiring" and "VD2C drive single-phase 220V main circuit wiring" 118 + 119 +Add 4.3 "Absolute Encoder Cable Connector (Connector Type) Pin-out and Encoder Cable Pin Connection" 120 + 121 +Add 4.4.1 "Pin-out of VD2L servo drive control input and output (CN2 interface)" 122 + 123 +Add 4.4.1 "VD2L drive single phase 220V main circuit wiring" 124 + 125 +Add 4.4.2 "VD2L drive position pulse mode wiring" 126 + 127 +Add 4.4.3 "VD2L drive differential method" 128 + 129 +Add 4.4.3 "VD2L drive collector open circuit method" 130 + 131 +Add 4.4.5 "VD2L drive digital input circuit" 132 + 133 +Add 4.4.5 "VD2L drive digital output circuit" 134 + 135 +Add 4.5.1 "VD2L drive VD2L type and PC connection method" 136 + 137 +Chapter 6 138 + 139 +Revise 6.2 "P0-01 Parameter Table 6-11 Control Mode Parameter Details" 140 + 141 +Revise 6.2 "Table 6-15 Position Pulse Type Selection Parameter Details" 142 + 143 +Revise 6.2 "Add VD2L P0-14 parameters" 144 + 145 +Add 6.2.6 "VD2L-0xxSA1P pulse signal DO output function" 146 + 147 +Revise 6.2.6 "Comments on P6-28, P6-30 and P6-32" 148 + 149 +Revise 6.3.1 "Comments on supported models of P5-03, P5-04, P5-01 and P5-02" 150 + 151 +Revise 6.4.1 "Unsupported models for P1-07" 152 + 153 +Revise 6.4.1 "Table 6-45 AI_1 related parameter detail " 154 + 155 +Revise 6.4.3 "Comments on P1-14" 156 + 157 +Revise 6.4.3 "Comments on Table 6-52 Mixed Control Mode Parameters" 158 + 159 +Revise 6.6.4 "Functions of P0-30" 160 + 161 +Chapter 7 162 + 163 +Revise 7.4.3 "Applicable Models for Related Parameters of Low Frequency Vibration Suppression Function" 164 + 165 +Revise 7.4.4 "Applicable models for Related Parameters of Type A Vibration Suppression Function" 166 + 167 +Chapter 9 168 + 169 +Revise the function introduction for P0-30, and add the function of shielding encoder over temperature function, etc. 170 + 171 +Revise the value range of P10-4 and cancel the shielding overload protection function 172 + 173 +Add P10-11 function, enabling function of motor stall over temperature protection 174 + 175 +Add a note about the VD2L model not supporting some parameters. 176 + 177 +Add U0-49 motor overload internal count 178 + 179 +Chapter 10 180 + 181 +Add the function introduction of ER.45 drive stall over temperature protection. 182 + 183 +Revise ER.27 Not clearable properties; 184 +)))|((( 185 +Update V1.20 firmware 186 + 187 +Add VD2L series model 188 + 189 +Add VD2-050TA1G model 190 +))) 191 + 93 93 The following table lists the servo driver models and supported firmware. 94 94 95 95 | |**Supported models**|**Corresponding model**|**Voltage**|**Supported firmware** 96 -|(% rowspan="1 1" %)**Wecon VD2SA series servo drives manual**|VD2-010SA1G|(% rowspan="2" %)VD2A|(% rowspan="10" %)220V|(% rowspan="7" %)(((195 +|(% colspan="1" rowspan="16" %)**Wecon VD2SA series servo drives manual**|VD2-010SA1G|(% rowspan="2" %)VD2A|(% rowspan="12" %)220V|(% rowspan="7" %)((( 97 97 V1.10 98 98 99 99 V1.12 ... ... @@ -109,6 +109,10 @@ 109 109 V1.17 110 110 111 111 V1.18 211 + 212 +V1.19 213 + 214 +V1.20 112 112 ))) 113 113 |VD2-014SA1G 114 114 |VD2-016SA1G|(% rowspan="5" %)VD2B ... ... @@ -131,10 +131,19 @@ 131 131 ))) 132 132 |VD2F-010SA1P 133 133 |VD2F-014SA1P 134 -|VD2-021TA1G|VD2B|380V|((( 237 +|VD2L-010SA1P|(% rowspan="2" %)VD2L|(% rowspan="2" %)V1.00 238 +|VD2L-014SA1P 239 +|VD2-021TA1G|VD2B|(% colspan="1" rowspan="4" %)380V|((( 135 135 V1.01 136 136 137 137 V1.17 138 138 139 139 V1.18 245 + 246 +V1.19 247 + 248 +V1.20 140 140 ))) 250 +|VD2-030TA1G|(% rowspan="3" %)VD2C|(% rowspan="3" %)V1.20 251 +|VD2-040TA1G 252 +|VD2-0250TA1G