Changes for page VD2 SA Series
Last modified by Iris on 2025/08/02 17:40
Summary
-
Page properties (3 modified, 0 added, 0 removed)
Details
- Page properties
-
- Title
-
... ... @@ -1,1 +1,1 @@ 1 - 02VD2 SA Series1 +VD2 SA Series - Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Mora1 +XWiki.Iris - Content
-
... ... @@ -1,6 +1,6 @@ 1 1 = **Preface** = 2 2 3 -This 3 +This manual is applicable to Wecon VD2 Series absolute value servo drives (**VD2 SA series**). 4 4 5 5 In order to use this series of servo drives correctly, please read this manual carefully in advance and save it for later use. 6 6 ... ... @@ -10,13 +10,19 @@ 10 10 11 11 This manual is suitable for introductory and use reference books for elementary and intermediate readers. At the same time, all interpretation rights of this manual belong to our company. 12 12 13 -(% class="warning" %)|[[image:image-20220923133747-1.png]] 13 +(% class="warning" %)|((( 14 +(% style="text-align:center" %) 15 +[[image:image-20220923133747-1.png]] 16 +))) 14 14 |The danger caused by failure to operate as required may result in serious injuries or even death. 15 15 16 -(% class="warning" %)|[[image:image-20220923133747-2.png||height="34" width="130"]] 19 +(% class="warning" %)|((( 20 +(% style="text-align:center" %) 21 +[[image:image-20220923133747-2.png||height="34" width="130"]] 22 +))) 17 17 |The danger caused by failure to operate as required may result in moderate or minor injuries, and equipment damage. 18 18 19 -= **User Manual ChangeRecord** =25 += **User Manual Version History** = 20 20 21 21 22 22 |=Date|=((( ... ... @@ -29,7 +29,7 @@ 29 29 30 30 VD2F-0□□SA1P model: V1.00 31 31 ))) 32 -|2022.3|A1.1|((( 38 +|2022.03|A1.1|((( 33 33 Chapter 2 Updating the servo driver naming, updating motor model table. 34 34 35 35 Chapter 3 Updating motor dimension drawing and dimension table ... ... @@ -42,7 +42,7 @@ 42 42 43 43 VD2F-0□□SA1P model: Add V1.01 and V1.02 44 44 ))) 45 -|2022.4|A1.2|((( 51 +|2022.04|A1.2|((( 46 46 Chapter 2 Updating section 2.1 “Servo Drive Specifications” 47 47 48 48 Chapter 4 Updating section 4.1 “Main Circuit Wiring”, updating section 4.5 “Communication signal wiring” ... ... @@ -72,10 +72,14 @@ 72 72 V1.01 73 73 ))) 74 74 |2022.11|V2.0|((( 75 -Chapter 4 Modify section 4.4.1 “VD2A, VD2F pin wiring diagram” Add section 4.4.1 “VD2-0xxSA1H driver DIDO pin distribution”. Add section 4.4.2 “VD2-0xxSA1H mode wiring diagram” Add section 4.4.5 “VD2-0xxSA1H DIDO signal”81 +Chapter 4 76 76 77 - Chapter 7 Updatingsection7.3.4 “ModelTrackingControl Function”Updating section7.3.5“GainSwitching Function”Updatingsection7.4.3“LowFrequencyVibrationSuppression Function”Updatingsection7.4.4 “TypeAVibrationSuppressionFunction”83 +Modify section 4.4.1 “VD2A, VD2F pin wiring diagram” Add section 4.4.1 “VD2-0xxSA1H driver DIDO pin distribution”. Add section 4.4.2 “VD2-0xxSA1H mode wiring diagram” Add section 4.4.5 “VD2-0xxSA1H DIDO signal” 78 78 85 +Chapter 7 86 + 87 +Updating section 7.3.4 “Model Tracking Control Function” Updating section 7.3.5 “Gain Switching Function” Updating section 7.4.3 “Low Frequency Vibration Suppression Function” Updating section 7.4.4 “Type A Vibration Suppression Function” 88 + 79 79 Chapters 9 and 11 adjust relevant parameters for new functions such as “model tracking control” 80 80 )))|((( 81 81 VD2-0□□SA1H model: ... ... @@ -82,11 +82,15 @@ 82 82 83 83 Add V1.17 firmware 84 84 ))) 85 -|2023.0 6|V2.1|(((86 -Chapter 6 Updating section 6.17 “Shutdown deceleration time” setting feature. Updating section 6.63 “P10-6 Multi-turn Absolute Encoder Reset” and “P10-8: Multi-turn Absolute Encoder Origin Offset Compensation” Updating section 6.64 "P00-31 Encoder Read and Write Verification Abnormal Threshold Setting"95 +|2023.05|V2.1|((( 96 +Chapter 6 87 87 88 - Chapter10add“Er.43 DriveOverloadFail”andparametercontent.Add“A80Drive OverloadAlarm”Modify“A91ParameterModificationtoo FrequentWarning”triggercondition.Add temporarysolutionfor"A93encoderread andwriteverificationabnormalfrequency istoohigh"98 +Updating section 6.17 “Shutdown deceleration time” setting feature. Updating section 6.63 “P10-6 Multi-turn Absolute Encoder Reset” and “P10-8: Multi-turn Absolute Encoder Origin Offset Compensation” Updating section 6.64 "P00-31 Encoder Read and Write Verification Abnormal Threshold Setting" 89 89 100 +Chapter 10 101 + 102 +Add “Er.43 Drive Overload Fail” and parameter content. Add “A80 Drive Overload Alarm” Modify “A91 Parameter Modification too Frequent Warning” trigger condition. Add temporary solution for "A93 encoder read and write verification abnormal frequency is too high" 103 + 90 90 Chapters 9 and 11 adjust relevant parameters for new functions such as “Estop shutdown deceleration time” 91 91 )))|Add V1.18 firmware 92 92 |2024.01|V2.2|((( ... ... @@ -182,17 +182,51 @@ 182 182 183 183 Revise ER.27 Not clearable properties; 184 184 )))|((( 185 - Update V1.20 firmware199 +Update V1.20 firmware 186 186 187 - Add VD2L series model201 +Add VD2L series model 188 188 189 - Add VD2-050TA1G model203 +Add VD2-050TA1G model 190 190 ))) 205 +|((( 206 +2024.09 207 +)))|((( 208 +V2.3 209 +)))|((( 210 +Chapter 2 Amend subsection 2.13 “Basic specifications” 191 191 212 +Chapter 3 Add a new subsection 3.13 “Installation environment for servo drives” 213 + 214 +Addition of subsection 3.23 “Installation environment for servomotors” 215 +)))|((( 216 +New changes to the description of environmental conditions 217 +))) 218 +|2024.12|V2.4|((( 219 +Chapter 6 220 + 221 +Added section 6.8 “Home Return Mode (HM)”; 222 + 223 +Chapter 9 224 + 225 +Revised the content of "P00-04 Function Code"; 226 + 227 +Added "Group P01: P01-39; P01-40; P01-41; P01-42; P01-43; P01-44 "; 228 + 229 +Added "U0 Group: U0-59 bus voltage historical maximum and U0-60 average power historical maximum; 230 + 231 +Chapter 10 232 + 233 +Section 10.3, added ER.19 Software Overcurrent; 234 +)))|((( 235 +Added VD2 series V1.22 firmware 236 + 237 +Added VD2L V1.02 firmware 238 +))) 239 + 192 192 The following table lists the servo driver models and supported firmware. 193 193 194 -| |**Supported models**|**Corresponding model**|**Voltage**|**Supported firmware** 195 -|(% rowspan="11" %)**Wecon VD2SA series servo drives manual**|VD2-010SA1G|(% rowspan="2" %)VD2A|(% rowspan="1 0" %)220V|(% rowspan="7" %)(((242 +| | | |**Supported models**|**Corresponding model**|**Voltage**|**Supported firmware** 243 +|(% rowspan="18" %) |(% rowspan="18" %) |(% colspan="1" rowspan="18" %)**Wecon VD2SA series servo drives manual**|VD2-010SA1G|(% rowspan="2" %)VD2 A type|(% rowspan="12" %)220V|(% rowspan="7" %)((( 196 196 V1.10 197 197 198 198 V1.12 ... ... @@ -208,9 +208,17 @@ 208 208 V1.17 209 209 210 210 V1.18 259 + 260 +V1.19 261 + 262 +V1.20 263 + 264 +V1.21 265 + 266 +V1.22 211 211 ))) 212 212 |VD2-014SA1G 213 -|VD2-016SA1G|(% rowspan="5" %)VD2B 269 +|VD2-016SA1G|(% rowspan="5" %)VD2 B type 214 214 |VD2-019SA1G 215 215 |VD2-021SA1G 216 216 |VD2-025SA1GF ... ... @@ -227,13 +227,52 @@ 227 227 V1.17 228 228 229 229 V1.18 286 + 287 +V1.19 288 + 289 +V1.20 290 + 291 +V1.21 292 + 293 +V1.22 230 230 ))) 231 231 |VD2F-010SA1P 232 232 |VD2F-014SA1P 233 -|VD2-021TA1G|VD2B|380V|((( 297 +|VD2L-010SA1P|(% rowspan="2" %)VD2L|(% rowspan="2" %)((( 298 +V1.00 299 + 234 234 V1.01 235 235 302 +V1.02 303 +))) 304 +|VD2L-014SA1P 305 +|((( 306 +VD2-016TA1G 307 +)))|(% colspan="1" rowspan="3" %)VD2 B type|(% colspan="1" rowspan="6" %)380V|(% colspan="1" rowspan="3" %)((( 308 +V1.01 309 + 236 236 V1.17 237 237 238 238 V1.18 313 + 314 +V1.19 315 + 316 +V1.20 317 + 318 +V1.21 319 + 320 +V1.22 239 239 ))) 322 +|((( 323 +VD2-019TA1G 324 +))) 325 +|VD2-021TA1G 326 +|VD2-030TA1G|(% rowspan="3" %)VD2 C type|(% rowspan="3" %)((( 327 +V1.20 328 + 329 +V1.21 330 + 331 +V1.22 332 +))) 333 +|VD2-040TA1G 334 +|VD2-050TA1G