Changes for page VD2 SA Series
Last modified by Iris on 2025/08/02 17:40
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -78,14 +78,10 @@ 78 78 V1.01 79 79 ))) 80 80 |2022.11|V2.0|((( 81 -Chapter 4 81 +Chapter 4 Modify section 4.4.1 “VD2A, VD2F pin wiring diagram” Add section 4.4.1 “VD2-0xxSA1H driver DIDO pin distribution”. Add section 4.4.2 “VD2-0xxSA1H mode wiring diagram” Add section 4.4.5 “VD2-0xxSA1H DIDO signal” 82 82 83 - Modifysection4.4.1“VD2A,VD2F pinwiringdiagram”Addsection4.4.1“VD2-0xxSA1H driver DIDO pindistribution”.Addsection4.4.2“VD2-0xxSA1H modewiringdiagram”Addsection4.4.5“VD2-0xxSA1HDIDOsignal”83 +Chapter 7 Updating section 7.3.4 “Model Tracking Control Function” Updating section 7.3.5 “Gain Switching Function” Updating section 7.4.3 “Low Frequency Vibration Suppression Function” Updating section 7.4.4 “Type A Vibration Suppression Function” 84 84 85 -Chapter 7 86 - 87 -Updating section 7.3.4 “Model Tracking Control Function” Updating section 7.3.5 “Gain Switching Function” Updating section 7.4.3 “Low Frequency Vibration Suppression Function” Updating section 7.4.4 “Type A Vibration Suppression Function” 88 - 89 89 Chapters 9 and 11 adjust relevant parameters for new functions such as “model tracking control” 90 90 )))|((( 91 91 VD2-0□□SA1H model: ... ... @@ -93,14 +93,10 @@ 93 93 Add V1.17 firmware 94 94 ))) 95 95 |2023.05|V2.1|((( 96 -Chapter 6 92 +Chapter 6 Updating section 6.17 “Shutdown deceleration time” setting feature. Updating section 6.63 “P10-6 Multi-turn Absolute Encoder Reset” and “P10-8: Multi-turn Absolute Encoder Origin Offset Compensation” Updating section 6.64 "P00-31 Encoder Read and Write Verification Abnormal Threshold Setting" 97 97 98 - Updating section6.17“Shutdowndecelerationtime”settingfeature. Updating section6.63“P10-6Multi-turn AbsoluteEncoderReset”and “P10-8:Multi-turnAbsoluteEncoderOriginOffsetCompensation”Updatingsection6.64"P00-31EncoderRead andWriteVerificationAbnormalThresholdSetting"94 +Chapter 10 add “Er.43 Drive Overload Fail” and parameter content. Add “A80 Drive Overload Alarm” Modify “A91 Parameter Modification too Frequent Warning” trigger condition. Add temporary solution for "A93 encoder read and write verification abnormal frequency is too high" 99 99 100 -Chapter 10 101 - 102 -Add “Er.43 Drive Overload Fail” and parameter content. Add “A80 Drive Overload Alarm” Modify “A91 Parameter Modification too Frequent Warning” trigger condition. Add temporary solution for "A93 encoder read and write verification abnormal frequency is too high" 103 - 104 104 Chapters 9 and 11 adjust relevant parameters for new functions such as “Estop shutdown deceleration time” 105 105 )))|Add V1.18 firmware 106 106 |2024.01|V2.2|((( ... ... @@ -202,35 +202,16 @@ 202 202 203 203 Add VD2-050TA1G model 204 204 ))) 205 -|((( 206 -2024.09 207 -)))|((( 208 -V2.3 209 -)))|((( 210 -Chapter 2 Amend subsection 2.13 “Basic specifications” 211 - 212 -Chapter 3 Add a new subsection 3.13 “Installation environment for servo drives” 213 - 214 -Addition of subsection 3.23 “Installation environment for servomotors” 215 -)))|((( 216 -New changes to the description of environmental conditions 217 -))) 218 218 |2024.12|V2.4|((( 219 -Chapter 6 198 +Chapter 6, added section 6.8 “Home Return Mode (HM)”; 220 220 221 - Addedsection6.8 “HomeReturnMode(HM)”;200 +Chapter 9: Revised the content of "P00-04 Function Code"; 222 222 223 -Chapter 9 224 - 225 -Revised the content of "P00-04 Function Code"; 226 - 227 227 Added "Group P01: P01-39; P01-40; P01-41; P01-42; P01-43; P01-44 "; 228 228 229 229 Added "U0 Group: U0-59 bus voltage historical maximum and U0-60 average power historical maximum; 230 230 231 -Chapter 10 232 - 233 -Section 10.3, added ER.19 Software Overcurrent; 206 +Chapter 10, Section 10.3, added ER.19 Software Overcurrent; 234 234 )))|((( 235 235 Added VD2 series V1.22 firmware 236 236 ... ... @@ -331,4 +331,4 @@ 331 331 V1.22 332 332 ))) 333 333 |VD2-040TA1G 334 -|VD2-050TA1G 307 +|VD2-0250TA1G