Changes for page VD2 SA Series
Last modified by Iris on 2025/08/02 17:40
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -35,7 +35,7 @@ 35 35 36 36 VD2F-0□□SA1P model: V1.00 37 37 ))) 38 -|2022. 03|A1.1|(((38 +|2022.3|A1.1|((( 39 39 Chapter 2 Updating the servo driver naming, updating motor model table. 40 40 41 41 Chapter 3 Updating motor dimension drawing and dimension table ... ... @@ -48,7 +48,7 @@ 48 48 49 49 VD2F-0□□SA1P model: Add V1.01 and V1.02 50 50 ))) 51 -|2022. 04|A1.2|(((51 +|2022.4|A1.2|((( 52 52 Chapter 2 Updating section 2.1 “Servo Drive Specifications” 53 53 54 54 Chapter 4 Updating section 4.1 “Main Circuit Wiring”, updating section 4.5 “Communication signal wiring” ... ... @@ -78,14 +78,10 @@ 78 78 V1.01 79 79 ))) 80 80 |2022.11|V2.0|((( 81 -Chapter 4 81 +Chapter 4 Modify section 4.4.1 “VD2A, VD2F pin wiring diagram” Add section 4.4.1 “VD2-0xxSA1H driver DIDO pin distribution”. Add section 4.4.2 “VD2-0xxSA1H mode wiring diagram” Add section 4.4.5 “VD2-0xxSA1H DIDO signal” 82 82 83 - Modifysection4.4.1“VD2A,VD2F pinwiringdiagram”Addsection4.4.1“VD2-0xxSA1H driver DIDO pindistribution”.Addsection4.4.2“VD2-0xxSA1H modewiringdiagram”Addsection4.4.5“VD2-0xxSA1HDIDOsignal”83 +Chapter 7 Updating section 7.3.4 “Model Tracking Control Function” Updating section 7.3.5 “Gain Switching Function” Updating section 7.4.3 “Low Frequency Vibration Suppression Function” Updating section 7.4.4 “Type A Vibration Suppression Function” 84 84 85 -Chapter 7 86 - 87 -Updating section 7.3.4 “Model Tracking Control Function” Updating section 7.3.5 “Gain Switching Function” Updating section 7.4.3 “Low Frequency Vibration Suppression Function” Updating section 7.4.4 “Type A Vibration Suppression Function” 88 - 89 89 Chapters 9 and 11 adjust relevant parameters for new functions such as “model tracking control” 90 90 )))|((( 91 91 VD2-0□□SA1H model: ... ... @@ -92,15 +92,11 @@ 92 92 93 93 Add V1.17 firmware 94 94 ))) 95 -|2023.0 5|V2.1|(((96 -Chapter 6 91 +|2023.06|V2.1|((( 92 +Chapter 6 Updating section 6.17 “Shutdown deceleration time” setting feature. Updating section 6.63 “P10-6 Multi-turn Absolute Encoder Reset” and “P10-8: Multi-turn Absolute Encoder Origin Offset Compensation” Updating section 6.64 "P00-31 Encoder Read and Write Verification Abnormal Threshold Setting" 97 97 98 - Updating section6.17“Shutdowndecelerationtime”settingfeature. Updating section6.63“P10-6Multi-turn AbsoluteEncoderReset”and “P10-8:Multi-turnAbsoluteEncoderOriginOffsetCompensation”Updatingsection6.64"P00-31EncoderRead andWriteVerificationAbnormalThresholdSetting"94 +Chapter 10 add “Er.43 Drive Overload Fail” and parameter content. Add “A80 Drive Overload Alarm” Modify “A91 Parameter Modification too Frequent Warning” trigger condition. Add temporary solution for "A93 encoder read and write verification abnormal frequency is too high" 99 99 100 -Chapter 10 101 - 102 -Add “Er.43 Drive Overload Fail” and parameter content. Add “A80 Drive Overload Alarm” Modify “A91 Parameter Modification too Frequent Warning” trigger condition. Add temporary solution for "A93 encoder read and write verification abnormal frequency is too high" 103 - 104 104 Chapters 9 and 11 adjust relevant parameters for new functions such as “Estop shutdown deceleration time” 105 105 )))|Add V1.18 firmware 106 106 |2024.01|V2.2|((( ... ... @@ -202,35 +202,16 @@ 202 202 203 203 Add VD2-050TA1G model 204 204 ))) 205 -|((( 206 -2024.09 207 -)))|((( 208 -V2.3 209 -)))|((( 210 -Chapter 2 Amend subsection 2.13 “Basic specifications” 197 +|2024.11|V2.4|((( 198 +Chapter 6, added section 6.8 “Home Return Mode (HM)”; 211 211 212 -Chapter 3Adda newsubsection3.13 “Installationenvironmentfor servodrives”200 +Chapter 9: Revised the content of "P00-04 Function Code"; 213 213 214 -Addition of subsection 3.23 “Installation environment for servomotors” 215 -)))|((( 216 -New changes to the description of environmental conditions 217 -))) 218 -|2024.12|V2.4|((( 219 -Chapter 6 220 - 221 -Added section 6.8 “Home Return Mode (HM)”; 222 - 223 -Chapter 9 224 - 225 -Revised the content of "P00-04 Function Code"; 226 - 227 227 Added "Group P01: P01-39; P01-40; P01-41; P01-42; P01-43; P01-44 "; 228 228 229 229 Added "U0 Group: U0-59 bus voltage historical maximum and U0-60 average power historical maximum; 230 230 231 -Chapter 10 232 - 233 -Section 10.3, added ER.19 Software Overcurrent; 206 +Chapter 10, Section 10.3, added ER.19 Software Overcurrent; 234 234 )))|((( 235 235 Added VD2 series V1.22 firmware 236 236 ... ... @@ -239,8 +239,8 @@ 239 239 240 240 The following table lists the servo driver models and supported firmware. 241 241 242 -| | | |**Supported models**|**Corresponding model**|**Voltage**|**Supported firmware**243 -|(% rowspan="18" %) |(% rowspan="18" %) |(%colspan="1" rowspan="18" %)**Wecon VD2SA series servo drives manual**|VD2-010SA1G|(% rowspan="2" %)VD2 A type|(% rowspan="12" %)220V|(% rowspan="7" %)(((215 +| |**Supported models**|**Corresponding model**|**Voltage**|**Supported firmware** 216 +|(% colspan="1" rowspan="16" %)**Wecon VD2SA series servo drives manual**|VD2-010SA1G|(% rowspan="2" %)VD2 A type|(% rowspan="12" %)220V|(% rowspan="7" %)((( 244 244 V1.10 245 245 246 246 V1.12 ... ... @@ -261,9 +261,7 @@ 261 261 262 262 V1.20 263 263 264 -V1.21 265 - 266 -V1.22 237 + 267 267 ))) 268 268 |VD2-014SA1G 269 269 |VD2-016SA1G|(% rowspan="5" %)VD2 B type ... ... @@ -288,9 +288,7 @@ 288 288 289 289 V1.20 290 290 291 -V1.21 292 - 293 -V1.22 262 + 294 294 ))) 295 295 |VD2F-010SA1P 296 296 |VD2F-014SA1P ... ... @@ -297,14 +297,10 @@ 297 297 |VD2L-010SA1P|(% rowspan="2" %)VD2L|(% rowspan="2" %)((( 298 298 V1.00 299 299 300 -V1.01 301 - 302 -V1.02 269 + 303 303 ))) 304 304 |VD2L-014SA1P 305 -|((( 306 -VD2-016TA1G 307 -)))|(% colspan="1" rowspan="3" %)VD2 B type|(% colspan="1" rowspan="6" %)380V|(% colspan="1" rowspan="3" %)((( 272 +|VD2-021TA1G|VD2 B type|(% colspan="1" rowspan="4" %)380V|((( 308 308 V1.01 309 309 310 310 V1.17 ... ... @@ -315,20 +315,12 @@ 315 315 316 316 V1.20 317 317 318 -V1.21 319 - 320 -V1.22 283 + 321 321 ))) 322 -|((( 323 -VD2-019TA1G 324 -))) 325 -|VD2-021TA1G 326 326 |VD2-030TA1G|(% rowspan="3" %)VD2 C type|(% rowspan="3" %)((( 327 327 V1.20 328 328 329 -V1.21 330 - 331 -V1.22 288 + 332 332 ))) 333 333 |VD2-040TA1G 334 -|VD2-050TA1G 291 +|VD2-0250TA1G