1 = **Preface** =
2
3 This manual is applicable to Wecon VD2 Series absolute value servo drives (**VD2 SA series**).
4
5 In order to use this series of servo drives correctly, please read this manual carefully in advance and save it for later use.
6
7 During use, if you have any doubts about the function and performance of this equipment, please contact our technicians for relevant assistance to use this equipment smoothly.
8
9 The company's products are constantly being improved and upgraded, and the contents of this manual are subject to change without notice.
10
11 This manual is suitable for introductory and use reference books for elementary and intermediate readers. At the same time, all interpretation rights of this manual belong to our company.
12
13 (% class="warning" %)|(((
14 (% style="text-align:center" %)
15 [[image:image-20220923133747-1.png]]
16 )))
17 |The danger caused by failure to operate as required may result in serious injuries or even death.
18
19 (% class="warning" %)|(((
20 (% style="text-align:center" %)
21 [[image:image-20220923133747-2.png||height="34" width="130"]]
22 )))
23 |The danger caused by failure to operate as required may result in moderate or minor injuries, and equipment damage.
24
25 = **User Manual Version History** =
26
27
28 |**Date**|**Version**|**Changes**|**Applicable models and firmware reversions**
29 |2021.12|A1.0|First release version|(((
30 VD2-0□□SA1G model: V1.10, V1.12
31
32 VD2F-0□□SA1P model: V1.00
33 )))
34 |2022.03|A1.1|(((
35 Chapter 2
36
37 Updating the servo driver naming.
38
39 Updating motor model table.
40
41 Chapter 3
42
43 Updating motor dimension drawing and dimension table
44
45 Chapter 6
46
47 Add new section 6.4.4 "Speed limit in speed mode", updating relevant parameter content for firmware upgrade
48
49 Chapter 11
50
51 Add the description of the scope of application of the cable
52 )))|(((
53 VD2-0□□SA1G model: Add V1.13
54
55 VD2F-0□□SA1P model: Add V1.01 and V1.02
56 )))
57 |2022.04|A1.2|(((
58 Chapter 2
59
60 Updating section 2.1.3 “Servo drive specifications”
61
62 Chapter 4
63
64 Updating section 4.1 “Main circuit wiring”.
65
66 Updating section 4.5 “Communication signal wiring”
67
68 Chapter 5
69
70 Updating section 5.3.3 “Restore factory settings” process and instructions
71
72 Chapter 6
73
74 Updating section 6.6 “Absolute value system”
75
76 Chapter 7
77
78 Updating section 7.3 “Gain adjustment” renderings
79
80 Chapter 8
81
82 Updating section 8.2.5 “Communication example”
83
84 Chapter 10
85
86 Updating section 10.2.2 “Fault and warning code table”.
87
88 Add section 10.3 “Troubleshooting”
89
90 Chapters 9 and 11
91
92 Adjust relevant parameters for firmware upgrades
93 )))|(((
94 VD2-0□□SA1G model:
95
96 Add V1.14
97
98 VD2F-0□□SA1P model:
99
100 V1.01, V1.02
101
102 Add VD2-021TA1G model:V1.01
103 )))
104 |2022.11|V2.0|(((
105 Chapter 4
106
107 Modify section 4.4.1 “VD2A, VD2F pin wiring diagram”
108
109 Add section 4.4.1 “vVD2-0xxsa1h driver dido pin distribution”. Add section 4.4.2 “VD2-0xxSA1H mode wiring diagram”
110
111 Add section 4.4.5 “VD2-0xxSA1H dido signal”
112
113 Chapter 7
114
115 Updating section 7.3.4 “Model tracking control function” Updating section 7.3.5 “Gain switching function”
116
117 Updating section 7.4.3 “Low frequency vibration suppression function”
118
119 Updating section 7.4.4 “Type a vibration suppression function”
120
121 Chapters 9 and 11
122
123 Adjust relevant parameters for new functions such as “Model tracking control”
124 )))|(((
125 VD2-0□□SA1H model:
126
127 Add V1.17 firmware
128 )))
129 |2023.05|V2.1|(((
130 Chapter 6
131
132 Updating section 6.17 “Shutdown deceleration time” Setting feature.
133
134 Updating section 6.63 “P10-6 multi-turn absolute encoder reset” And “P10-8: Multi-turn absolute encoder origin offset compensation”
135
136 Updating section 6.64 "P00-31 encoder read and write verification abnormal threshold setting"
137
138 Chapter 10
139
140 Add “Er.43 drive overload fail” And parameter content.
141
142 Add “A80 drive overpower warning”
143
144 Modify “A91 parameter modification too frequent warning” Trigger condition.
145
146 Add temporary solution for "A93 encoder read and write verification abnormal frequency is too high"
147
148 Chapters 9 and 11
149
150 Adjust relevant parameters for new functions such as “Estop shutdown deceleration time”
151 )))|(((
152 Add V1.18 firmware
153 )))
154 |2024.01|V2.2|(((
155 Chapter 2
156
157 Update 2.1.1 "Servo drive model naming rules"
158
159 Add 2.1.1 "Vd2l drive appearance and nameplate" And "VD2C drive appearance and nameplate"
160
161 Add 2.1.2 "Composition of VD2L drive" And "Composition of VD2C drive appearance"
162
163 Add 2.1.3 "Electrical specifications for vd2l drives" And "Electrical specifications for VD2C drives"
164
165 Add 2.2.2 "Motor (wire type) composition diagram"
166
167 Chapter 3
168
169 Add 3.1.1 "VD2L drive installation dimension diagram" And "VD2C drive installation dimension diagram"
170
171 Add 3.1.4 "VD2L drive minimum installation dimension diagram" And "VD2C drive minimum installation dimension diagram"
172
173 Add 3.1.4 "VD2L drive parallel installation dimension diagram" and "VD2C drive parallel installation dimension diagram"
174
175 Chapter 4
176
177 Add 4.1.1 "VD2L servo drive main circuit terminal arrangement and VD2C servo drive main circuit terminal arrangement"
178
179 Add 4.1.2 "VD2L drive single-phase 220v main circuit wiring" and "VD2C drive three-phase 380V main circuit wiring"
180
181 Add 4.3 "Absolute encoder cable connector (connector type) pin-out and encoder cable pin connection"
182
183 Add 4.4.1 "Pin-out of VD2L servo drive control input and output (CN2 interface)"
184
185 Add 4.4.1 "VD2L drive single-phase 220V main circuit wiring"
186
187 Add 4.4.2 "VD2L drive position pulse mode wiring"
188
189 Add 4.4.3 "VD2L drive differential method"
190
191 Add 4.4.3 "VD2L drive collector open circuit method"
192
193 Add 4.4.5 "VD2L drive digital input circuit"
194
195 Add 4.4.5 "VD2L drive digital output circuit"
196
197 Add 4.5.1 "VD2L drive VD2L type and PC connection method"
198
199 Chapter 6
200
201 Revise 6.2 "P0-01 parameter table 6-11 control mode parameter details"
202
203 Revise 6.2 "Table 6-16 position pulse type selection parameter details"
204
205 Revise 6.2 "Add VD2L P0-14 parameters"
206
207 Add 6.2.6 "VD2L-0xxsa1p pulse signal do output function"
208
209 Revise 6.2.6 "Comments on P6-28, P6-30 and P6-32"
210
211 Revise 6.3.1 "Comments on supported models of P5-03, P5-04, P5-01 and P5-02"
212
213 Revise 6.4.1 "Unsupported models for p1-07"
214
215 Revise 6.4.1 "Table 6-46 AI_1 related parameter detail "
216
217 Revise 6.4.3 "Comments on p1-14"
218
219 Revise 6.4.3 "Comments on table 6-53 mixed control mode parameters"
220
221 Revise 6.6.4 "Functions of P0-30"
222
223 Chapter 7
224
225 Revise 7.4.3 "Applicable models for related parameters of low frequency vibration suppression function"
226
227 Revise 7.4.4 "Applicable models for related parameters of type a vibration suppression function"
228
229 Chapter 9
230
231 Revise the function introduction for P0-30, and add the function of shielding encoder over temperature function, etc.
232
233 Revise the value range of P10-4 and cancel the shielding overload protection function
234
235 Add P10-11 function, enabling function of motor stall over temperature protection
236
237 Add a note about the VD2L model not supporting some parameters.
238
239 Add U0-49 motor overload internal count
240
241 Chapter 10
242
243 Add the function introduction of Er.45 drive stall over temperature protection.
244
245 Revise er.27 not clearable properties;
246 )))|(((
247
248
249 Update V1.20 firmware
250
251 Add VD2L series model
252
253 Add VD2C series model
254 )))
255 |2024.09|V2.3|(((
256 Chapter 2
257
258 Amend subsection 2.13 “Basic specifications”
259
260
261 Chapter 3
262
263 Add a new subsection 3.13 “Installation environment for servo drives”
264
265 Addition of subsection 3.23 “Installation environment for servomotors”
266 )))|(((
267 New changes to the description of environmental conditions
268 )))
269 |2024.12|V2.4|(((
270 Chapter 6
271
272 Added section 6.8 “Home return mode (HM)”
273
274 Chapter 9
275
276 Revised the content of "P00-04 function code"
277
278 Added "Group p01: P01-39; P01-40; P01-41; P01-42; P01-43; P01-44 "
279
280 Added "U0 group: U0-59 bus voltage historical maximum and u0-60 average power historical maximum
281
282 Chapter 10
283
284 Section 10.3, added “Er.19 software overcurrent”
285 )))|(((
286 Added VD2 series V1.22 firmware
287
288 Added VD2L V1.02 firmware
289 )))
290 |2026.01|V3.0|(((
291 Chapter 9:
292
293 Add [P01-20] Software overcurrent detection window
294
295 [P0-33] Multi-turn encoder undervoltage fault auto clear
296
297 [P02-40], [P02-41], [P02-42], [P02-43] Gravity compensation related function codes
298
299 [P02-47], [P02-48, ], [P02-49], [P02-50] Quadrant protrusion compensation related function codes
300
301 [P07] Group Multi-position function code updates & Adjustments
302 )))|(((
303 Added VD2 series V1.24 firmware
304
305 Added VD2L V1.03 firmware
306 )))
307
308 The following table lists the servo driver models and supported firmware.
309
310 |(% style="width:199px" %) |(% style="width:264px" %)**Supported models**|(% style="width:300px" %)**Corresponding model**|**Voltage**|**Supported firmware**
311 |(% rowspan="18" style="width:199px" %)**Wecon VD2SA series servo drives manual**|(% style="width:264px" %)VD2-010SA1G|(% rowspan="2" style="width:300px" %)VD2A type|(% rowspan="12" %)220V|(% rowspan="7" %)(((
312 V1.10
313
314 V1.12
315
316 V1.13
317
318 V1.14
319
320 V1.15
321
322 V1.16
323
324 V1.17
325
326 V1.18
327
328 V1.19
329
330 V1.20
331
332 V1.21
333
334 V1.22
335
336 V1.23
337
338 V1.24
339 )))
340 |(% style="width:264px" %)VD2-014SA1G
341 |(% style="width:264px" %)VD2-016SA1G|(% rowspan="5" style="width:300px" %)VD2B type
342 |(% style="width:264px" %)VD2-019SA1G
343 |(% style="width:264px" %)VD2-021SA1G
344 |(% style="width:264px" %)VD2-025SA1GF
345 |(% style="width:264px" %)VD2-030SA1G
346 |(% style="width:264px" %)VD2F-003SA1P|(% rowspan="3" style="width:300px" %)VD2F|(% rowspan="3" %)(((
347 V1.00
348
349 V1.01
350
351 V1.02
352
353 V1.16
354
355 V1.17
356
357 V1.18
358
359 V1.19
360
361 V1.20
362
363 V1.21
364
365 V1.22
366
367 V1.23
368
369 V1.24
370 )))
371 |(% style="width:264px" %)VD2F-010SA1P
372 |(% style="width:264px" %)VD2F-014SA1P
373 |(% style="width:264px" %)VD2L-010SA1P|(% rowspan="2" style="width:300px" %)VD2L|(% rowspan="2" %)(((
374 V1.00
375
376 V1.01
377
378 V1.02
379
380 V1.03
381 )))
382 |(% style="width:264px" %)VD2L-014SA1P
383 |(% style="width:264px" %)VD2-016TA1G|(% rowspan="3" style="width:300px" %)VD2B type|(% rowspan="6" %)380V|(% rowspan="3" %)(((
384 V1.01
385
386 V1.17
387
388 V1.18
389
390 V1.19
391
392 V1.20
393
394 V1.21
395
396 V1.22
397
398 V1.23
399
400 V1.24
401 )))
402 |(% style="width:264px" %)VD2-019TA1G
403 |(% style="width:264px" %)VD2-021TA1G
404 |(% style="width:264px" %)VD2-030TA1G|(% rowspan="3" style="width:300px" %)VD2C type|(% rowspan="3" %)(((
405 V1.20
406
407 V1.21
408
409 V1.22
410
411 V1.23
412
413 V1.24
414 )))
415 |(% style="width:264px" %)VD2-040TA1G
416 |(% style="width:264px" %)VD2-050TA1G