Changes for page VD3E Series

Last modified by Mora Zhou on 2025/04/02 15:49

From version 11.3
edited by Mora Zhou
on 2025/04/02 15:26
Change comment: There is no comment for this version
To version 12.5
edited by Mora Zhou
on 2025/04/02 15:40
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -122,7 +122,35 @@
122 122  
123 123  Add drive stalled and over-temperature protection fault;
124 124  )))|★ VD3E-0XXTA1G model
125 -| | | |(((
125 +|March 2025|V3.0|(((
126 +**Chapter 1**
127 +
128 +Add 1.7 Leakage protection description and ciorcuit breaker recommendation
129 +
130 +**Chapter 2**
131 +
132 +Add 2.1.3 (2) Basic specifications
133 +
134 +**Chapter 3**
135 +
136 +Modify 3.1.3 Installation environment
137 +
138 +Modify 3.2.3 Installation environment
139 +
140 +(% style="background-color:transparent" %)**Chapter 8**
141 +
142 +Add 605B, 605C, 605E, 60FF. 6502 object dictionary
143 +
144 +Add bus voltage history maximum value 201E-41 and 201E-42 average maximum power
145 +
146 +Modify 6040 and 605A object dictionary
147 +
148 +Modify 2002-01 default value
149 +
150 +**Chapter 10**
151 +
152 +Add 10.2 ER.19 Software overcurrent
153 +)))|(((
126 126  ★ VD3E-0XXSA1G model
127 127  
128 128  ★ VD3E-0XXTA1G model