Changes for page VD3E Series
Last modified by Mora Zhou on 2025/04/02 15:49
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Jim1 +XWiki.Mora - Content
-
... ... @@ -8,13 +8,71 @@ 8 8 9 9 This manual is suitable for introductory and use reference books for elementary and intermediate readers. At the same time, all interpretation rights of this manual belong to our company. 10 10 11 -(% class="warning" %)|[[image:dangerous.png||height="38" width="122"]] 11 +(% class="warning" %)|((( 12 +(% style="text-align:center" %) 13 +[[image:dangerous.png||height="38" width="122"]] 14 +))) 12 12 |The danger caused by failure to operate as required may result in serious injuries or even death. 13 13 14 -(% class="warning" %)|[[image:notice.png||height="38" style="float:left" width="95"]] 17 +(% class="warning" %)|((( 18 +(% style="text-align:center" %) 19 +[[image:notice.png||height="38" width="95"]] 20 +))) 15 15 |The danger caused by failure to operate as required may result in moderate or minor injuries, and equipment damage. 16 16 17 -(% class="info" %)|Date|Changed version|Change content|Corresponding software version 18 -|March 2022|V1.0|First edition|★ VD3E-0SA1G model 23 +(% style="margin-left:auto; margin-right:auto" %) 24 +(% class="info" %)|Date|Changed version|(% style="width:812px" %)Change content|(% style="width:276px" %)Corresponding software version 25 +|March 2022|V1.0|(% style="width:812px" %)First edition|(% style="width:276px" %)((( 26 +★ VD3E-0SA1G model 27 +))) 28 +|August 2023|V2.0|(% style="width:812px" %)((( 29 +**Chapter 7:** 19 19 31 +Add the supplementary explanation of touch probe function and DI touch probe function; 32 + 33 +Add homing mode 35, and add 60E6 to set absolute coordinates and relative coordinate modes; 34 + 35 +**Chapter 8:** 36 + 37 +Add 60E0, 60C5h and 60C6h object dictionaries; 38 + 39 +Delete 6071, 6074, 607D: 01 object dictionaries; 40 + 41 +Modify the data range and default value of some object dictionaries; 42 + 43 +U0-57 is added to support 64-bit absolute position display; 44 + 45 +Add U0-48 servo power-on counting description, U0-52 encoder bit monitoring value; 46 + 47 +Update the object dictionary table and add 6000 groups of data format standard device sub-protocol areas; 48 + 49 +Add 2001-17, 2000-18, 2000-1F and other object dictionaries; Add JOG acceleration time 2001-25 and JOG deceleration time 2001-26; 50 + 51 +Add 2004-12 speed feedback filter time; 52 + 53 +Add 200A-05 motor model and 200A-07 manual motor code; 54 + 55 +Speed feedforward filtering time P2-10 default value and range unit changed; 56 + 57 +Torque limit source P1-14 added: EtherCAT control; 58 + 59 +**Chapter 10:** 60 + 61 +Add Er.43 driver overload fault and A-80 power limit alarm; 62 + 63 +Er.27 [Encoder disconnected] changed to be unclearable. 64 + 65 +Modify the fault logic and troubleshooting method of A-91; 66 + 67 +Add temporary solutions to A-93; 68 + 69 +**Chapter 11:** 70 + 71 +Add the hardware requirements of European EMC certification standard; 72 + 73 +Add EMC input noise filter recommendation; 74 + 75 +Add cable and wiring requirements, etc. 76 +)))|(% style="width:276px" %)★VD3E-0¨¨SA1G model 77 + 20 20