Changes for page 05 Servo Product Manual
Last modified by Jim(Forgotten) on 2025/03/20 10:19
From version 68.1
edited by Molly
on 2024/09/18 15:43
on 2024/09/18 15:43
Change comment:
There is no comment for this version
To version 75.1
edited by Devin Chen
on 2024/09/26 13:46
on 2024/09/26 13:46
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Molly1 +XWiki.DevinChen - Content
-
... ... @@ -128,15 +128,15 @@ 128 128 )))|((( 129 129 **Auto-tuning** 130 130 )))|(% colspan="3" rowspan="1" %)((( 131 -Automatic load inertia identification, automatic rigidity self-tuning 131 +Automatic load inertia identification, automatic rigidity self-tuning (SCTool) 132 132 ))) 133 133 |(% colspan="1" rowspan="2" %)((( 134 134 **Waveform** 135 135 )))|(% colspan="3" rowspan="1" %)((( 136 -4 channels waveform monitoring 136 +4 channels waveform monitoring (SCTool) 137 137 ))) 138 138 |(% colspan="3" rowspan="1" %)((( 139 -10s waveform data recording 139 +10s waveform data recording (SCTool) 140 140 ))) 141 141 |((( 142 142 **Parameter management** ... ... @@ -287,19 +287,15 @@ 287 287 **Pulse feedback output** 288 288 )))|(% colspan="1" rowspan="1" style="width:503px" %)((( 289 289 Z signal open collector output 290 -)))|(% rowspan="1" style="width:364px" %)((( 291 -ABZ differential output(VD2-XXXXXXH 292 - 293 -series support collector signal feedback) 294 -))) 290 +)))|(% rowspan="1" style="width:364px" %)ABZ phase pulse output or pulse+direction output 295 295 |(% colspan="3" style="width:277px" %)(% style="background-color:transparent" %)**Internal Command**|(% colspan="2" rowspan="1" style="width:867px" %)((( 296 296 8 segment internal speed command, 16 segment internal position command 297 297 ))) 298 298 |(% colspan="3" style="width:277px" %)((( 299 299 **Communication** 300 -)))|(% colspan="2"rowspan="1" style="width:867px" %)(((301 -MODBUS orMODBUS302 -))) 296 +)))|(% rowspan="1" style="width:867px" %)((( 297 +MODBUS RS485 and MODBUS RS422(SCTool) 298 +)))|(% rowspan="1" style="width:867px" %)MODBUS RS485 and Type-C(SCTool) 303 303 |(% colspan="3" rowspan="2" style="width:277px" %)((( 304 304 **Braking resistor** 305 305 )))|(% colspan="4" rowspan="1" style="width:867px" %)((( ... ... @@ -315,10 +315,10 @@ 315 315 )))|(% colspan="2" style="width:39px" %)((( 316 316 **Auto-tuning** 317 317 )))|(% colspan="1" rowspan="1" style="width:503px" %)((( 318 -Automatic load inertia identification,automatic rigidity self-tuning 319 -)))|(% rowspan="1" style="width:364px" %) -314 +Automatic load inertia identification, automatic rigidity self-tuning 315 +)))|(% rowspan="1" style="width:364px" %)Automatic load inertia identification 320 320 |(% colspan="2" style="width:39px" %)((( 321 -** Blendmode**317 +**Mix control** 322 322 )))|(% colspan="1" rowspan="1" style="width:503px" %)((( 323 323 YES 324 324 )))|(% rowspan="1" style="width:364px" %)- ... ... @@ -927,3 +927,40 @@ 927 927 VD2/VD3E C type 928 928 )))|Power cable:P-U3O1-H32J4M-*MX4|Single-turn:E-J1394-H28K7M-*MX5-A 929 929 |Brake cable:No need|Multi-turn:E-J1394-H28K7M-*MX7-A1 926 + 927 += **Servo **Input Current Parameter Table = 928 + 929 +(% cellspacing="500" style="width:1200px" %) 930 +|=Servo Drive Output Current (A)|=Servo Drive Output Voltage (V)|=Servo Drive Output Power (W)|=Efficiency|=Power factor|=Input current 931 +(single phase) (A)|=Input current 932 +(three phase) (A)|=Recommended power cable 933 +diameter(mm²) 934 +|3|(% colspan="1" rowspan="7" %)220|100|(% colspan="1" rowspan="11" %)0.7|(% rowspan="11" %)0.8|0.90|0.52|0.5 935 +|10|400|3.61|2.08|0.75 936 +|14|750|6.76|3.91|((( 937 +1.5(For single phase) 938 + 939 +1(For three phase) 940 +))) 941 +|16|1800|16.23|9.37|((( 942 +4(For single phase) 943 + 944 +2(For three phase) 945 +))) 946 +|21|2200|19.84|11.46|((( 947 +4(For single phase) 948 + 949 +2.5(For three phase) 950 +))) 951 +|25|2600|23.45|13.40|(% colspan="1" rowspan="2" %)((( 952 +6(For single phase) 953 + 954 +4(For three phase) 955 +))) 956 +|30|3000|26.79|15.46 957 +|21|(% colspan="1" rowspan="4" %)380|3000| |9.04|2 958 +|30|4500| |13.57|4 959 +|40|6000| |18.09|(% colspan="1" rowspan="2" %)6 960 +|50|7500| |22.61 961 + 962 +>For more motor application scenarios, please refer to this [[link>>https://docs.we-con.com.cn/bin/view/Servo/FAQ/How%20to%20estimate%20the%20maximum%20input%20current%20of%20a%20servo%20drive]].