Changes for page 05 Servo Product Manual

Last modified by Jim(Forgotten) on 2025/03/20 10:19

From version 74.1
edited by Devin Chen
on 2024/09/26 11:57
Change comment: There is no comment for this version
To version 78.1
edited by Mora Zhou
on 2024/09/26 13:59
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.DevinChen
1 +XWiki.Mora
Content
... ... @@ -926,6 +926,7 @@
926 926  
927 927  = **Servo **Input Current Parameter Table =
928 928  
929 +(% style="margin-left:auto; margin-right:auto; width:1300px" %)
929 929  |=Servo Drive Output Current (A)|=Servo Drive Output Voltage (V)|=Servo Drive Output Power (W)|=Efficiency|=Power factor|=Input current
930 930  (single phase) (A)|=Input current
931 931  (three phase) (A)|=Recommended power cable
... ... @@ -933,24 +933,24 @@
933 933  |3|(% colspan="1" rowspan="7" %)220|100|(% colspan="1" rowspan="11" %)0.7|(% rowspan="11" %)0.8|0.90|0.52|0.5
934 934  |10|400|3.61|2.08|0.75
935 935  |14|750|6.76|3.91|(((
936 -1.5For single phase
937 +1.5 (For single phase)
937 937  
938 -1(For three phase)
939 +1 (For three phase)
939 939  )))
940 940  |16|1800|16.23|9.37|(((
941 -4For single phase
942 +4 (For single phase)
942 942  
943 -2(For three phase)
944 +2 (For three phase)
944 944  )))
945 945  |21|2200|19.84|11.46|(((
946 -4For single phase
947 +4 (For single phase)
947 947  
948 -2.5(For three phase)
949 +2.5 (For three phase)
949 949  )))
950 950  |25|2600|23.45|13.40|(% colspan="1" rowspan="2" %)(((
951 -6For single phase
952 +6 (For single phase)
952 952  
953 -4(For three phase)
954 +4 (For three phase)
954 954  )))
955 955  |30|3000|26.79|15.46
956 956  |21|(% colspan="1" rowspan="4" %)380|3000| |9.04|2