... ... @@ -21,8 +21,6 @@
21 21  |F0.03|Main Frequency Source|9|RS485 Communication
22 22  |F0.10|Maximum Output Frequency|50.00|(((
23 23  50Hz
24 -
25 -
26 26  )))
27 27  |F0.12|Maximum Running Frequency|50.00|50Hz
28 28  |F0.18|Acceleration Time|30.0|30s
... ... @@ -29,11 +29,11 @@
29 29  |F0.19|Deceleration Time|30.0|30s
30 30  |F6.02|Relay 1 Option|1|Running
31 31  |FC.00|Broadcast Address|21-32|VFD Address
32 -|Fc.01|Baud Rate|5|9600bps
33 -|Fc.02|Communication Format|1|0,N,1
34 -|FA.03|Overvoltage Suppression Gain|1110|Invalid
30 +|FC.01|Baud Rate|5|9600bps
31 +|FC.02|Communication Format|1|0,N,1
32 +|FA.03|Overvoltage Suppression Gain|1110|Invalid5.
35 35  
36 -== **5. Solution Features** ==
34 += **5.Solution Features** =
37 37  
38 38  ~1. The VC handles high-inertia loads with high torque, enabling high-speed operation, smooth deceleration and braking, and stable stopping, thus improving product efficiency.
39 39