... ... @@ -1,12 +1,13 @@
1 1  = **1 V-BOX pin definition** =
2 2  
3 3  (% style="text-align:center" %)
4 -[[image:1624587334538-981.png||class="img-thumbnail" height="113" width="200"]]
4 +[[image:1624587334538-981.png||height="113" width="200" class="img-thumbnail"]]
5 5  
6 6  **Interface definition of V-BOX H-00/H-WF/H-AG**
7 +
7 7  COM1 interface definition
8 8  
9 -(% class="table-bordered" style="width:710px" %)
10 +(% class="table-bordered" style="margin-left:auto; margin-right:auto; width:710px" %)
10 10  |=Pin|=(% style="width: 200px;" %)definition|=(% style="width: 161px;" %)Pin|=(% style="width: 163px;" %)definition
11 11  |1|(% style="width:200px" %)RS422 TX+/RS485 A+|(% style="width:161px" %)2|(% style="width:163px" %)RS232 RXD
12 12  |3|(% style="width:200px" %)RS232 TXD|(% style="width:161px" %)5|(% style="width:163px" %)GND
... ... @@ -13,28 +13,32 @@
13 13  |6|(% style="width:200px" %)RS422 TX-/RS485 B-|(% style="width:161px" %)8|(% style="width:163px" %)RS422 RX-
14 14  |9|(% style="width:200px" %)RS422 RX+|(% style="width:161px" %) |(% style="width:163px" %)
15 15  
16 -**✎Note: **1、The RS422 and RS485 communication Pin in the COM1 cannot be used at the same time.
17 -2、RS485 communication interfaces are all with isolation.
17 +(% class="box infomessage" %)
18 +(((
19 +**✎Note: **
18 18  
21 +* The RS422 and RS485 communication Pin in the COM1 cannot be used at the same time.
22 +* RS485 communication interfaces are all with isolation.
23 +)))
24 +
19 19  COM2  interface definition
20 20  
21 -A1+ ~-~-~-~-~-~-RS485+
27 +* A1+ ~-~-~-~-~-~-RS485+
28 +* B1- ~-~-~-~-~-~--RS485-
22 22  
23 -B1- ~-~-~-~-~-~--RS485-
24 -
25 25  COM3  interface definition
26 26  
27 -A2+ ~-~-~-~-~-~-RS485+
32 +* A2+ ~-~-~-~-~-~-RS485+
33 +* B2- ~-~-~-~-~-~--RS485-
28 28  
29 -B2- ~-~-~-~-~-~--RS485-
30 -
31 31  (% style="text-align:center" %)
32 -[[image:1626663446288-573.png||class="img-thumbnail" height="125" width="100"]]
36 +[[image:1626663446288-573.png||height="125" width="100" class="img-thumbnail"]]
33 33  
34 34  **Interface definition of V-BOX S-00**
39 +
35 35  COM1 interface definition
36 36  
37 -(% class="table-bordered" style="width:679px" %)
42 +(% class="table-bordered" style="margin-left:auto; margin-right:auto; width:679px" %)
38 38  |=Pin|=(% style="width: 188px;" %)definition|=(% style="width: 131px;" %)Pin|=(% style="width: 174px;" %)definition
39 39  |1|(% style="width:188px" %)RS422 TX+/RS485 A+|(% style="width:131px" %)2|(% style="width:174px" %)RS232 RXD
40 40  |3|(% style="width:188px" %)RS232 TXD|(% style="width:131px" %)5|(% style="width:174px" %)GND
... ... @@ -43,7 +43,7 @@
43 43  
44 44  COM2 interface definition
45 45  
46 -(% class="table-bordered" style="width:681px" %)
51 +(% class="table-bordered" style="margin-left:auto; margin-right:auto; width:681px" %)
47 47  |=Pin|=(% style="width: 194px;" %)definition|=(% style="width: 132px;" %)Pin|=(% style="width: 170px;" %)definition
48 48  |1|(% style="width:194px" %)RS485 A+|(% style="width:132px" %)2|(% style="width:170px" %)RS232 RXD
49 49  |3|(% style="width:194px" %)RS232 TXD|(% style="width:132px" %)5|(% style="width:170px" %)GND
... ... @@ -50,12 +50,15 @@
50 50  |6|(% style="width:194px" %)RS485 B-|(% style="width:132px" %)7|(% style="width:170px" %)COM3 RS485 A+
51 51  |8|(% style="width:194px" %)COM3 RS485 B-|(% style="width:132px" %) |(% style="width:170px" %)
52 52  
58 +(% class="box infomessage" %)
59 +(((
53 53  **✎Note: **The COM port of V-BOX can only support one communication method at a time.
61 +)))
54 54  
55 55  **Interface definition of V-BOX S-4G**
56 56  COM1 interface definition
57 57  
58 -(% class="table-bordered" style="width:687px" %)
66 +(% class="table-bordered" style="margin-left:auto; margin-right:auto; width:687px" %)
59 59  |=Pin|=(% style="width: 195px;" %)definition|=(% style="width: 137px;" %)Pin|=(% style="width: 169px;" %)definition
60 60  |1|(% style="width:195px" %)RS422 TX+/RS485 A+|(% style="width:137px" %)2|(% style="width:169px" %)RS232 RXD
61 61  |3|(% style="width:195px" %)RS232 TXD|(% style="width:137px" %)5|(% style="width:169px" %)GND
... ... @@ -64,7 +64,7 @@
64 64  
65 65  COM2 interface definition
66 66  
67 -(% class="table-bordered" style="width:690px" %)
75 +(% class="table-bordered" style="margin-left:auto; margin-right:auto; width:690px" %)
68 68  |=Pin|=(% style="width: 195px;" %)definition|=(% style="width: 139px;" %)Pin|=(% style="width: 171px;" %)definition
69 69  |1|(% style="width:195px" %)RS485 A+|(% style="width:139px" %)2|(% style="width:171px" %)RS232 RXD
70 70  |3|(% style="width:195px" %)RS232 TXD|(% style="width:139px" %)5|(% style="width:171px" %)GND
... ... @@ -71,12 +71,15 @@
71 71  |6|(% style="width:195px" %)RS485 B-|(% style="width:139px" %)7|(% style="width:171px" %)COM3 RS485 A+
72 72  |8|(% style="width:195px" %)COM3 RS485 B-|(% style="width:139px" %) |(% style="width:171px" %)
73 73  
82 +(% class="box infomessage" %)
83 +(((
74 74  **✎Note: **The COM port of V-BOX can only support one communication method at a time.
85 +)))
75 75  
76 76  **Interface definition of V-BOX S-AG**
77 77  COM1 interface definition
78 78  
79 -(% class="table-bordered" style="width:696px" %)
90 +(% class="table-bordered" style="margin-left:auto; margin-right:auto; width:696px" %)
80 80  |=Pin|=(% style="width: 194px;" %)definition|=(% style="width: 142px;" %)Pin|=(% style="width: 174px;" %)definition
81 81  |1|(% style="width:194px" %)RS422 TX+/RS485 A+|(% style="width:142px" %)2|(% style="width:174px" %)RS232 RXD
82 82  |3|(% style="width:194px" %)RS232 TXD|(% style="width:142px" %)5|(% style="width:174px" %)GND
... ... @@ -85,7 +85,7 @@
85 85  
86 86  COM2 interface definition
87 87  
88 -(% class="table-bordered" style="width:694px" %)
99 +(% class="table-bordered" style="margin-left:auto; margin-right:auto; width:694px" %)
89 89  |=Pin|=(% style="width: 194px;" %)definition|=(% style="width: 145px;" %)Pin|=(% style="width: 170px;" %)definition
90 90  |1|(% style="width:194px" %)RS485 A+|(% style="width:145px" %)2|(% style="width:170px" %)RS232 RXD
91 91  |3|(% style="width:194px" %)RS232 TXD|(% style="width:145px" %)5|(% style="width:170px" %)GND
... ... @@ -92,12 +92,15 @@
92 92  |6|(% style="width:194px" %)RS485 B-|(% style="width:145px" %)7|(% style="width:170px" %)COM3 RS485 A+
93 93  |8|(% style="width:194px" %)COM3 RS485 B-|(% style="width:145px" %) |(% style="width:170px" %)
94 94  
106 +(% class="box infomessage" %)
107 +(((
95 95  **✎Note: **The COM port of V-BOX can only support one communication method at a time.
109 +)))
96 96  
97 97  **Interface definition of V-BOX S-3N**
98 98  COM1 interface definition
99 99  
100 -(% class="table-bordered" style="width:701px" %)
114 +(% class="table-bordered" style="margin-left:auto; margin-right:auto; width:701px" %)
101 101  |=Pin|=(% style="width: 200px;" %)definition|=(% style="width: 145px;" %)Pin|=(% style="width: 170px;" %)definition
102 102  |1|(% style="width:200px" %)RS422 TX+/RS485 A+|(% style="width:145px" %)2|(% style="width:170px" %)RS232 RXD
103 103  |3|(% style="width:200px" %)RS232 TXD|(% style="width:145px" %)5|(% style="width:170px" %)GND
... ... @@ -104,11 +104,18 @@
104 104  |6|(% style="width:200px" %)RS422 TX-/RS485 B-|(% style="width:145px" %)8|(% style="width:170px" %)RS422 RX-
105 105  |9|(% style="width:200px" %)RS422 RX+|(% style="width:145px" %) |(% style="width:170px" %)
106 106  
107 -**✎Note: **1. The RS422 and RS485 communication modes in the COM1 port of V-BOX cannot be used at the same time.
108 -2、485 communication interfaces are all with isolation. **Interface definition of V-BOX S-NG**
121 +(% class="box infomessage" %)
122 +(((
123 +**✎Note: **
124 +
125 +* The RS422 and RS485 communication modes in the COM1 port of V-BOX cannot be used at the same time.
126 +* 485 communication interfaces are all with isolation.
127 +)))
128 +
129 +**Interface definition of V-BOX S-NG**
109 109  COM1 interface definition
110 110  
111 -(% class="table-bordered" style="width:706px" %)
132 +(% class="table-bordered" style="margin-left:auto; margin-right:auto; width:706px" %)
112 112  |=Pin|=(% style="width: 195px;" %)definition|=(% style="width: 156px;" %)Pin|=(% style="width: 169px;" %)definition
113 113  |1|(% style="width:195px" %)RS422 TX+/RS485 A+|(% style="width:156px" %)2|(% style="width:169px" %)RS232 RXD
114 114  |3|(% style="width:195px" %)RS232 TXD|(% style="width:156px" %)5|(% style="width:169px" %)GND
... ... @@ -115,13 +115,18 @@
115 115  |6|(% style="width:195px" %)RS422 TX-/RS485 B-|(% style="width:156px" %)8|(% style="width:169px" %)RS422 RX-
116 116  |9|(% style="width:195px" %)RS422 RX+|(% style="width:156px" %) |(% style="width:169px" %)
117 117  
118 -**✎Note: **1. The RS422 and RS485 communication modes in the COM1 port of V-BOX cannot be used at the same time。
119 -2、485 communication interfaces are all with isolation.
139 +(% class="box infomessage" %)
140 +(((
141 +**✎Note: **
120 120  
143 +* The RS422 and RS485 communication modes in the COM1 port of V-BOX cannot be used at the same time。
144 +* 485 communication interfaces are all with isolation.
145 +)))
146 +
121 121  **Interface definition of V-BOX E-00**
122 122  COM1 interface definition
123 123  
124 -(% class="table-bordered" style="width:710px" %)
150 +(% class="table-bordered" style="margin-left:auto; margin-right:auto; width:710px" %)
125 125  |=Pin|=(% style="width: 200px;" %)definition|=(% style="width: 161px;" %)Pin|=(% style="width: 163px;" %)definition
126 126  |1|(% style="width:200px" %)RS422 TX+/RS485 A+|(% style="width:161px" %)2|(% style="width:163px" %)RS232 RXD
127 127  |3|(% style="width:200px" %)RS232 TXD|(% style="width:161px" %)5|(% style="width:163px" %)GND
... ... @@ -128,5 +128,10 @@
128 128  |6|(% style="width:200px" %)RS422 TX-/RS485 B-|(% style="width:161px" %)8|(% style="width:163px" %)RS422 RX-
129 129  |9|(% style="width:200px" %)RS422 RX+|(% style="width:161px" %) |(% style="width:163px" %)
130 130  
131 -**✎Note: **1、The RS422 and RS485 communication modes in the COM1 port of V-BOX cannot be used at the same time.
132 -2、485 communication interfaces are all with isolation.
157 +(% class="box infomessage" %)
158 +(((
159 +**✎Note: **
160 +
161 +* The RS422 and RS485 communication modes in the COM1 port of V-BOX cannot be used at the same time。
162 +* 485 communication interfaces are all with isolation.
163 +)))