Changes for page 2 V-BOX pin definition
Last modified by Stone Wu on 2022/09/23 07:03
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. admin1 +XWiki.Stone - Content
-
... ... @@ -1,12 +1,13 @@ 1 1 = **1 V-BOX pin definition** = 2 2 3 3 (% style="text-align:center" %) 4 -[[image:1624587334538-981.png|| class="img-thumbnail" height="113" width="200"]]4 +[[image:1624587334538-981.png||height="113" width="200" class="img-thumbnail"]] 5 5 6 6 **Interface definition of V-BOX H-00/H-WF/H-AG** 7 + 7 7 COM1 interface definition 8 8 9 -(% class="table-bordered" style="width:710px" %) 10 +(% class="table-bordered" style="margin-left:auto; margin-right:auto; width:710px" %) 10 10 |=Pin|=(% style="width: 200px;" %)definition|=(% style="width: 161px;" %)Pin|=(% style="width: 163px;" %)definition 11 11 |1|(% style="width:200px" %)RS422 TX+/RS485 A+|(% style="width:161px" %)2|(% style="width:163px" %)RS232 RXD 12 12 |3|(% style="width:200px" %)RS232 TXD|(% style="width:161px" %)5|(% style="width:163px" %)GND ... ... @@ -13,28 +13,32 @@ 13 13 |6|(% style="width:200px" %)RS422 TX-/RS485 B-|(% style="width:161px" %)8|(% style="width:163px" %)RS422 RX- 14 14 |9|(% style="width:200px" %)RS422 RX+|(% style="width:161px" %) |(% style="width:163px" %) 15 15 16 -**✎Note: **1、The RS422 and RS485 communication Pin in the COM1 cannot be used at the same time. 17 -2、RS485 communication interfaces are all with isolation. 17 +(% class="box infomessage" %) 18 +((( 19 +**✎Note: ** 18 18 21 +* The RS422 and RS485 communication Pin in the COM1 cannot be used at the same time. 22 +* RS485 communication interfaces are all with isolation. 23 +))) 24 + 19 19 COM2 interface definition 20 20 21 -A1+ ~-~-~-~-~-~-RS485+ 27 +* A1+ ~-~-~-~-~-~-RS485+ 28 +* B1- ~-~-~-~-~-~--RS485- 22 22 23 -B1- ~-~-~-~-~-~--RS485- 24 - 25 25 COM3 interface definition 26 26 27 -A2+ ~-~-~-~-~-~-RS485+ 32 +* A2+ ~-~-~-~-~-~-RS485+ 33 +* B2- ~-~-~-~-~-~--RS485- 28 28 29 -B2- ~-~-~-~-~-~--RS485- 30 - 31 31 (% style="text-align:center" %) 32 -[[image:1626663446288-573.png|| class="img-thumbnail" height="125" width="100"]]36 +[[image:1626663446288-573.png||height="125" width="100" class="img-thumbnail"]] 33 33 34 34 **Interface definition of V-BOX S-00** 39 + 35 35 COM1 interface definition 36 36 37 -(% class="table-bordered" style="width:679px" %) 42 +(% class="table-bordered" style="margin-left:auto; margin-right:auto; width:679px" %) 38 38 |=Pin|=(% style="width: 188px;" %)definition|=(% style="width: 131px;" %)Pin|=(% style="width: 174px;" %)definition 39 39 |1|(% style="width:188px" %)RS422 TX+/RS485 A+|(% style="width:131px" %)2|(% style="width:174px" %)RS232 RXD 40 40 |3|(% style="width:188px" %)RS232 TXD|(% style="width:131px" %)5|(% style="width:174px" %)GND ... ... @@ -43,7 +43,7 @@ 43 43 44 44 COM2 interface definition 45 45 46 -(% class="table-bordered" style="width:681px" %) 51 +(% class="table-bordered" style="margin-left:auto; margin-right:auto; width:681px" %) 47 47 |=Pin|=(% style="width: 194px;" %)definition|=(% style="width: 132px;" %)Pin|=(% style="width: 170px;" %)definition 48 48 |1|(% style="width:194px" %)RS485 A+|(% style="width:132px" %)2|(% style="width:170px" %)RS232 RXD 49 49 |3|(% style="width:194px" %)RS232 TXD|(% style="width:132px" %)5|(% style="width:170px" %)GND ... ... @@ -50,12 +50,15 @@ 50 50 |6|(% style="width:194px" %)RS485 B-|(% style="width:132px" %)7|(% style="width:170px" %)COM3 RS485 A+ 51 51 |8|(% style="width:194px" %)COM3 RS485 B-|(% style="width:132px" %) |(% style="width:170px" %) 52 52 58 +(% class="box infomessage" %) 59 +((( 53 53 **✎Note: **The COM port of V-BOX can only support one communication method at a time. 61 +))) 54 54 55 55 **Interface definition of V-BOX S-4G** 56 56 COM1 interface definition 57 57 58 -(% class="table-bordered" style="width:687px" %) 66 +(% class="table-bordered" style="margin-left:auto; margin-right:auto; width:687px" %) 59 59 |=Pin|=(% style="width: 195px;" %)definition|=(% style="width: 137px;" %)Pin|=(% style="width: 169px;" %)definition 60 60 |1|(% style="width:195px" %)RS422 TX+/RS485 A+|(% style="width:137px" %)2|(% style="width:169px" %)RS232 RXD 61 61 |3|(% style="width:195px" %)RS232 TXD|(% style="width:137px" %)5|(% style="width:169px" %)GND ... ... @@ -64,7 +64,7 @@ 64 64 65 65 COM2 interface definition 66 66 67 -(% class="table-bordered" style="width:690px" %) 75 +(% class="table-bordered" style="margin-left:auto; margin-right:auto; width:690px" %) 68 68 |=Pin|=(% style="width: 195px;" %)definition|=(% style="width: 139px;" %)Pin|=(% style="width: 171px;" %)definition 69 69 |1|(% style="width:195px" %)RS485 A+|(% style="width:139px" %)2|(% style="width:171px" %)RS232 RXD 70 70 |3|(% style="width:195px" %)RS232 TXD|(% style="width:139px" %)5|(% style="width:171px" %)GND ... ... @@ -71,12 +71,15 @@ 71 71 |6|(% style="width:195px" %)RS485 B-|(% style="width:139px" %)7|(% style="width:171px" %)COM3 RS485 A+ 72 72 |8|(% style="width:195px" %)COM3 RS485 B-|(% style="width:139px" %) |(% style="width:171px" %) 73 73 82 +(% class="box infomessage" %) 83 +((( 74 74 **✎Note: **The COM port of V-BOX can only support one communication method at a time. 85 +))) 75 75 76 76 **Interface definition of V-BOX S-AG** 77 77 COM1 interface definition 78 78 79 -(% class="table-bordered" style="width:696px" %) 90 +(% class="table-bordered" style="margin-left:auto; margin-right:auto; width:696px" %) 80 80 |=Pin|=(% style="width: 194px;" %)definition|=(% style="width: 142px;" %)Pin|=(% style="width: 174px;" %)definition 81 81 |1|(% style="width:194px" %)RS422 TX+/RS485 A+|(% style="width:142px" %)2|(% style="width:174px" %)RS232 RXD 82 82 |3|(% style="width:194px" %)RS232 TXD|(% style="width:142px" %)5|(% style="width:174px" %)GND ... ... @@ -85,7 +85,7 @@ 85 85 86 86 COM2 interface definition 87 87 88 -(% class="table-bordered" style="width:694px" %) 99 +(% class="table-bordered" style="margin-left:auto; margin-right:auto; width:694px" %) 89 89 |=Pin|=(% style="width: 194px;" %)definition|=(% style="width: 145px;" %)Pin|=(% style="width: 170px;" %)definition 90 90 |1|(% style="width:194px" %)RS485 A+|(% style="width:145px" %)2|(% style="width:170px" %)RS232 RXD 91 91 |3|(% style="width:194px" %)RS232 TXD|(% style="width:145px" %)5|(% style="width:170px" %)GND ... ... @@ -92,12 +92,15 @@ 92 92 |6|(% style="width:194px" %)RS485 B-|(% style="width:145px" %)7|(% style="width:170px" %)COM3 RS485 A+ 93 93 |8|(% style="width:194px" %)COM3 RS485 B-|(% style="width:145px" %) |(% style="width:170px" %) 94 94 106 +(% class="box infomessage" %) 107 +((( 95 95 **✎Note: **The COM port of V-BOX can only support one communication method at a time. 109 +))) 96 96 97 97 **Interface definition of V-BOX S-3N** 98 98 COM1 interface definition 99 99 100 -(% class="table-bordered" style="width:701px" %) 114 +(% class="table-bordered" style="margin-left:auto; margin-right:auto; width:701px" %) 101 101 |=Pin|=(% style="width: 200px;" %)definition|=(% style="width: 145px;" %)Pin|=(% style="width: 170px;" %)definition 102 102 |1|(% style="width:200px" %)RS422 TX+/RS485 A+|(% style="width:145px" %)2|(% style="width:170px" %)RS232 RXD 103 103 |3|(% style="width:200px" %)RS232 TXD|(% style="width:145px" %)5|(% style="width:170px" %)GND ... ... @@ -104,11 +104,18 @@ 104 104 |6|(% style="width:200px" %)RS422 TX-/RS485 B-|(% style="width:145px" %)8|(% style="width:170px" %)RS422 RX- 105 105 |9|(% style="width:200px" %)RS422 RX+|(% style="width:145px" %) |(% style="width:170px" %) 106 106 107 -**✎Note: **1. The RS422 and RS485 communication modes in the COM1 port of V-BOX cannot be used at the same time. 108 -2、485 communication interfaces are all with isolation. **Interface definition of V-BOX S-NG** 121 +(% class="box infomessage" %) 122 +((( 123 +**✎Note: ** 124 + 125 +* The RS422 and RS485 communication modes in the COM1 port of V-BOX cannot be used at the same time. 126 +* 485 communication interfaces are all with isolation. 127 +))) 128 + 129 +**Interface definition of V-BOX S-NG** 109 109 COM1 interface definition 110 110 111 -(% class="table-bordered" style="width:706px" %) 132 +(% class="table-bordered" style="margin-left:auto; margin-right:auto; width:706px" %) 112 112 |=Pin|=(% style="width: 195px;" %)definition|=(% style="width: 156px;" %)Pin|=(% style="width: 169px;" %)definition 113 113 |1|(% style="width:195px" %)RS422 TX+/RS485 A+|(% style="width:156px" %)2|(% style="width:169px" %)RS232 RXD 114 114 |3|(% style="width:195px" %)RS232 TXD|(% style="width:156px" %)5|(% style="width:169px" %)GND ... ... @@ -115,13 +115,18 @@ 115 115 |6|(% style="width:195px" %)RS422 TX-/RS485 B-|(% style="width:156px" %)8|(% style="width:169px" %)RS422 RX- 116 116 |9|(% style="width:195px" %)RS422 RX+|(% style="width:156px" %) |(% style="width:169px" %) 117 117 118 -**✎Note: **1. The RS422 and RS485 communication modes in the COM1 port of V-BOX cannot be used at the same time。 119 -2、485 communication interfaces are all with isolation. 139 +(% class="box infomessage" %) 140 +((( 141 +**✎Note: ** 120 120 143 +* The RS422 and RS485 communication modes in the COM1 port of V-BOX cannot be used at the same time。 144 +* 485 communication interfaces are all with isolation. 145 +))) 146 + 121 121 **Interface definition of V-BOX E-00** 122 122 COM1 interface definition 123 123 124 -(% class="table-bordered" style="width:710px" %) 150 +(% class="table-bordered" style="margin-left:auto; margin-right:auto; width:710px" %) 125 125 |=Pin|=(% style="width: 200px;" %)definition|=(% style="width: 161px;" %)Pin|=(% style="width: 163px;" %)definition 126 126 |1|(% style="width:200px" %)RS422 TX+/RS485 A+|(% style="width:161px" %)2|(% style="width:163px" %)RS232 RXD 127 127 |3|(% style="width:200px" %)RS232 TXD|(% style="width:161px" %)5|(% style="width:163px" %)GND ... ... @@ -128,5 +128,10 @@ 128 128 |6|(% style="width:200px" %)RS422 TX-/RS485 B-|(% style="width:161px" %)8|(% style="width:163px" %)RS422 RX- 129 129 |9|(% style="width:200px" %)RS422 RX+|(% style="width:161px" %) |(% style="width:163px" %) 130 130 131 -**✎Note: **1、The RS422 and RS485 communication modes in the COM1 port of V-BOX cannot be used at the same time. 132 -2、485 communication interfaces are all with isolation. 157 +(% class="box infomessage" %) 158 +((( 159 +**✎Note: ** 160 + 161 +* The RS422 and RS485 communication modes in the COM1 port of V-BOX cannot be used at the same time。 162 +* 485 communication interfaces are all with isolation. 163 +)))