Changes for page 2 V-BOX pin definition
Last modified by Stone Wu on 2022/09/23 07:03
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Stone1 +XWiki.admin - Content
-
... ... @@ -1,13 +1,12 @@ 1 1 = **1 V-BOX pin definition** = 2 2 3 3 (% style="text-align:center" %) 4 -[[image:1624587334538-981.png||height="113" width="200" class="img-thumbnail"]]4 +[[image:1624587334538-981.png||class="img-thumbnail" height="113" width="200"]] 5 5 6 6 **Interface definition of V-BOX H-00/H-WF/H-AG** 7 - 8 8 COM1 interface definition 9 9 10 -(% class="table-bordered" style=" margin-left:auto; margin-right:auto;width:710px" %)9 +(% class="table-bordered" style="width:710px" %) 11 11 |=Pin|=(% style="width: 200px;" %)definition|=(% style="width: 161px;" %)Pin|=(% style="width: 163px;" %)definition 12 12 |1|(% style="width:200px" %)RS422 TX+/RS485 A+|(% style="width:161px" %)2|(% style="width:163px" %)RS232 RXD 13 13 |3|(% style="width:200px" %)RS232 TXD|(% style="width:161px" %)5|(% style="width:163px" %)GND ... ... @@ -14,32 +14,28 @@ 14 14 |6|(% style="width:200px" %)RS422 TX-/RS485 B-|(% style="width:161px" %)8|(% style="width:163px" %)RS422 RX- 15 15 |9|(% style="width:200px" %)RS422 RX+|(% style="width:161px" %) |(% style="width:163px" %) 16 16 17 -(% class="box infomessage" %) 18 -((( 19 -**✎Note: ** 16 +**✎Note: **1、The RS422 and RS485 communication Pin in the COM1 cannot be used at the same time. 17 +2、RS485 communication interfaces are all with isolation. 20 20 21 -* The RS422 and RS485 communication Pin in the COM1 cannot be used at the same time. 22 -* RS485 communication interfaces are all with isolation. 23 -))) 24 - 25 25 COM2 interface definition 26 26 27 -* A1+ ~-~-~-~-~-~-RS485+ 28 -* B1- ~-~-~-~-~-~--RS485- 21 +A1+ ~-~-~-~-~-~-RS485+ 29 29 23 +B1- ~-~-~-~-~-~--RS485- 24 + 30 30 COM3 interface definition 31 31 32 -* A2+ ~-~-~-~-~-~-RS485+ 33 -* B2- ~-~-~-~-~-~--RS485- 27 +A2+ ~-~-~-~-~-~-RS485+ 34 34 29 +B2- ~-~-~-~-~-~--RS485- 30 + 35 35 (% style="text-align:center" %) 36 -[[image:1626663446288-573.png||height="125" width="100" class="img-thumbnail"]]32 +[[image:1626663446288-573.png||class="img-thumbnail" height="125" width="100"]] 37 37 38 38 **Interface definition of V-BOX S-00** 39 - 40 40 COM1 interface definition 41 41 42 -(% class="table-bordered" style=" margin-left:auto; margin-right:auto;width:679px" %)37 +(% class="table-bordered" style="width:679px" %) 43 43 |=Pin|=(% style="width: 188px;" %)definition|=(% style="width: 131px;" %)Pin|=(% style="width: 174px;" %)definition 44 44 |1|(% style="width:188px" %)RS422 TX+/RS485 A+|(% style="width:131px" %)2|(% style="width:174px" %)RS232 RXD 45 45 |3|(% style="width:188px" %)RS232 TXD|(% style="width:131px" %)5|(% style="width:174px" %)GND ... ... @@ -48,7 +48,7 @@ 48 48 49 49 COM2 interface definition 50 50 51 -(% class="table-bordered" style=" margin-left:auto; margin-right:auto;width:681px" %)46 +(% class="table-bordered" style="width:681px" %) 52 52 |=Pin|=(% style="width: 194px;" %)definition|=(% style="width: 132px;" %)Pin|=(% style="width: 170px;" %)definition 53 53 |1|(% style="width:194px" %)RS485 A+|(% style="width:132px" %)2|(% style="width:170px" %)RS232 RXD 54 54 |3|(% style="width:194px" %)RS232 TXD|(% style="width:132px" %)5|(% style="width:170px" %)GND ... ... @@ -55,15 +55,12 @@ 55 55 |6|(% style="width:194px" %)RS485 B-|(% style="width:132px" %)7|(% style="width:170px" %)COM3 RS485 A+ 56 56 |8|(% style="width:194px" %)COM3 RS485 B-|(% style="width:132px" %) |(% style="width:170px" %) 57 57 58 -(% class="box infomessage" %) 59 -((( 60 60 **✎Note: **The COM port of V-BOX can only support one communication method at a time. 61 -))) 62 62 63 63 **Interface definition of V-BOX S-4G** 64 64 COM1 interface definition 65 65 66 -(% class="table-bordered" style=" margin-left:auto; margin-right:auto;width:687px" %)58 +(% class="table-bordered" style="width:687px" %) 67 67 |=Pin|=(% style="width: 195px;" %)definition|=(% style="width: 137px;" %)Pin|=(% style="width: 169px;" %)definition 68 68 |1|(% style="width:195px" %)RS422 TX+/RS485 A+|(% style="width:137px" %)2|(% style="width:169px" %)RS232 RXD 69 69 |3|(% style="width:195px" %)RS232 TXD|(% style="width:137px" %)5|(% style="width:169px" %)GND ... ... @@ -72,7 +72,7 @@ 72 72 73 73 COM2 interface definition 74 74 75 -(% class="table-bordered" style=" margin-left:auto; margin-right:auto;width:690px" %)67 +(% class="table-bordered" style="width:690px" %) 76 76 |=Pin|=(% style="width: 195px;" %)definition|=(% style="width: 139px;" %)Pin|=(% style="width: 171px;" %)definition 77 77 |1|(% style="width:195px" %)RS485 A+|(% style="width:139px" %)2|(% style="width:171px" %)RS232 RXD 78 78 |3|(% style="width:195px" %)RS232 TXD|(% style="width:139px" %)5|(% style="width:171px" %)GND ... ... @@ -79,15 +79,12 @@ 79 79 |6|(% style="width:195px" %)RS485 B-|(% style="width:139px" %)7|(% style="width:171px" %)COM3 RS485 A+ 80 80 |8|(% style="width:195px" %)COM3 RS485 B-|(% style="width:139px" %) |(% style="width:171px" %) 81 81 82 -(% class="box infomessage" %) 83 -((( 84 84 **✎Note: **The COM port of V-BOX can only support one communication method at a time. 85 -))) 86 86 87 87 **Interface definition of V-BOX S-AG** 88 88 COM1 interface definition 89 89 90 -(% class="table-bordered" style=" margin-left:auto; margin-right:auto;width:696px" %)79 +(% class="table-bordered" style="width:696px" %) 91 91 |=Pin|=(% style="width: 194px;" %)definition|=(% style="width: 142px;" %)Pin|=(% style="width: 174px;" %)definition 92 92 |1|(% style="width:194px" %)RS422 TX+/RS485 A+|(% style="width:142px" %)2|(% style="width:174px" %)RS232 RXD 93 93 |3|(% style="width:194px" %)RS232 TXD|(% style="width:142px" %)5|(% style="width:174px" %)GND ... ... @@ -96,7 +96,7 @@ 96 96 97 97 COM2 interface definition 98 98 99 -(% class="table-bordered" style=" margin-left:auto; margin-right:auto;width:694px" %)88 +(% class="table-bordered" style="width:694px" %) 100 100 |=Pin|=(% style="width: 194px;" %)definition|=(% style="width: 145px;" %)Pin|=(% style="width: 170px;" %)definition 101 101 |1|(% style="width:194px" %)RS485 A+|(% style="width:145px" %)2|(% style="width:170px" %)RS232 RXD 102 102 |3|(% style="width:194px" %)RS232 TXD|(% style="width:145px" %)5|(% style="width:170px" %)GND ... ... @@ -103,15 +103,12 @@ 103 103 |6|(% style="width:194px" %)RS485 B-|(% style="width:145px" %)7|(% style="width:170px" %)COM3 RS485 A+ 104 104 |8|(% style="width:194px" %)COM3 RS485 B-|(% style="width:145px" %) |(% style="width:170px" %) 105 105 106 -(% class="box infomessage" %) 107 -((( 108 108 **✎Note: **The COM port of V-BOX can only support one communication method at a time. 109 -))) 110 110 111 111 **Interface definition of V-BOX S-3N** 112 112 COM1 interface definition 113 113 114 -(% class="table-bordered" style=" margin-left:auto; margin-right:auto;width:701px" %)100 +(% class="table-bordered" style="width:701px" %) 115 115 |=Pin|=(% style="width: 200px;" %)definition|=(% style="width: 145px;" %)Pin|=(% style="width: 170px;" %)definition 116 116 |1|(% style="width:200px" %)RS422 TX+/RS485 A+|(% style="width:145px" %)2|(% style="width:170px" %)RS232 RXD 117 117 |3|(% style="width:200px" %)RS232 TXD|(% style="width:145px" %)5|(% style="width:170px" %)GND ... ... @@ -118,18 +118,11 @@ 118 118 |6|(% style="width:200px" %)RS422 TX-/RS485 B-|(% style="width:145px" %)8|(% style="width:170px" %)RS422 RX- 119 119 |9|(% style="width:200px" %)RS422 RX+|(% style="width:145px" %) |(% style="width:170px" %) 120 120 121 -(% class="box infomessage" %) 122 -((( 123 -**✎Note: ** 124 - 125 -* The RS422 and RS485 communication modes in the COM1 port of V-BOX cannot be used at the same time. 126 -* 485 communication interfaces are all with isolation. 127 -))) 128 - 129 -**Interface definition of V-BOX S-NG** 107 +**✎Note: **1. The RS422 and RS485 communication modes in the COM1 port of V-BOX cannot be used at the same time. 108 +2、485 communication interfaces are all with isolation. **Interface definition of V-BOX S-NG** 130 130 COM1 interface definition 131 131 132 -(% class="table-bordered" style=" margin-left:auto; margin-right:auto;width:706px" %)111 +(% class="table-bordered" style="width:706px" %) 133 133 |=Pin|=(% style="width: 195px;" %)definition|=(% style="width: 156px;" %)Pin|=(% style="width: 169px;" %)definition 134 134 |1|(% style="width:195px" %)RS422 TX+/RS485 A+|(% style="width:156px" %)2|(% style="width:169px" %)RS232 RXD 135 135 |3|(% style="width:195px" %)RS232 TXD|(% style="width:156px" %)5|(% style="width:169px" %)GND ... ... @@ -136,18 +136,13 @@ 136 136 |6|(% style="width:195px" %)RS422 TX-/RS485 B-|(% style="width:156px" %)8|(% style="width:169px" %)RS422 RX- 137 137 |9|(% style="width:195px" %)RS422 RX+|(% style="width:156px" %) |(% style="width:169px" %) 138 138 139 -(% class="box infomessage" %) 140 -((( 141 -**✎Note: ** 118 +**✎Note: **1. The RS422 and RS485 communication modes in the COM1 port of V-BOX cannot be used at the same time。 119 +2、485 communication interfaces are all with isolation. 142 142 143 -* The RS422 and RS485 communication modes in the COM1 port of V-BOX cannot be used at the same time。 144 -* 485 communication interfaces are all with isolation. 145 -))) 146 - 147 147 **Interface definition of V-BOX E-00** 148 148 COM1 interface definition 149 149 150 -(% class="table-bordered" style=" margin-left:auto; margin-right:auto;width:710px" %)124 +(% class="table-bordered" style="width:710px" %) 151 151 |=Pin|=(% style="width: 200px;" %)definition|=(% style="width: 161px;" %)Pin|=(% style="width: 163px;" %)definition 152 152 |1|(% style="width:200px" %)RS422 TX+/RS485 A+|(% style="width:161px" %)2|(% style="width:163px" %)RS232 RXD 153 153 |3|(% style="width:200px" %)RS232 TXD|(% style="width:161px" %)5|(% style="width:163px" %)GND ... ... @@ -154,10 +154,5 @@ 154 154 |6|(% style="width:200px" %)RS422 TX-/RS485 B-|(% style="width:161px" %)8|(% style="width:163px" %)RS422 RX- 155 155 |9|(% style="width:200px" %)RS422 RX+|(% style="width:161px" %) |(% style="width:163px" %) 156 156 157 -(% class="box infomessage" %) 158 -((( 159 -**✎Note: ** 160 - 161 -* The RS422 and RS485 communication modes in the COM1 port of V-BOX cannot be used at the same time。 162 -* 485 communication interfaces are all with isolation. 163 -))) 131 +**✎Note: **1、The RS422 and RS485 communication modes in the COM1 port of V-BOX cannot be used at the same time. 132 +2、485 communication interfaces are all with isolation.