Changes for page 2 V-BOX pin definition

Last modified by Stone Wu on 2022/09/23 07:03

From version 3.1
edited by Stone Wu
on 2022/09/23 07:03
Change comment: There is no comment for this version
To version 2.2
edited by Leo Wei
on 2022/08/01 09:35
Change comment: Update document after refactoring.

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Stone
1 +XWiki.admin
Content
... ... @@ -1,13 +1,12 @@
1 1  = **1 V-BOX pin definition** =
2 2  
3 3  (% style="text-align:center" %)
4 -[[image:1624587334538-981.png||height="113" width="200" class="img-thumbnail"]]
4 +[[image:1624587334538-981.png||class="img-thumbnail" height="113" width="200"]]
5 5  
6 6  **Interface definition of V-BOX H-00/H-WF/H-AG**
7 -
8 8  COM1 interface definition
9 9  
10 -(% class="table-bordered" style="margin-left:auto; margin-right:auto; width:710px" %)
9 +(% class="table-bordered" style="width:710px" %)
11 11  |=Pin|=(% style="width: 200px;" %)definition|=(% style="width: 161px;" %)Pin|=(% style="width: 163px;" %)definition
12 12  |1|(% style="width:200px" %)RS422 TX+/RS485 A+|(% style="width:161px" %)2|(% style="width:163px" %)RS232 RXD
13 13  |3|(% style="width:200px" %)RS232 TXD|(% style="width:161px" %)5|(% style="width:163px" %)GND
... ... @@ -14,32 +14,28 @@
14 14  |6|(% style="width:200px" %)RS422 TX-/RS485 B-|(% style="width:161px" %)8|(% style="width:163px" %)RS422 RX-
15 15  |9|(% style="width:200px" %)RS422 RX+|(% style="width:161px" %) |(% style="width:163px" %)
16 16  
17 -(% class="box infomessage" %)
18 -(((
19 -**✎Note: **
16 +**✎Note: **1、The RS422 and RS485 communication Pin in the COM1 cannot be used at the same time.
17 +2、RS485 communication interfaces are all with isolation.
20 20  
21 -* The RS422 and RS485 communication Pin in the COM1 cannot be used at the same time.
22 -* RS485 communication interfaces are all with isolation.
23 -)))
24 -
25 25  COM2  interface definition
26 26  
27 -* A1+ ~-~-~-~-~-~-RS485+
28 -* B1- ~-~-~-~-~-~--RS485-
21 +A1+ ~-~-~-~-~-~-RS485+
29 29  
23 +B1- ~-~-~-~-~-~--RS485-
24 +
30 30  COM3  interface definition
31 31  
32 -* A2+ ~-~-~-~-~-~-RS485+
33 -* B2- ~-~-~-~-~-~--RS485-
27 +A2+ ~-~-~-~-~-~-RS485+
34 34  
29 +B2- ~-~-~-~-~-~--RS485-
30 +
35 35  (% style="text-align:center" %)
36 -[[image:1626663446288-573.png||height="125" width="100" class="img-thumbnail"]]
32 +[[image:1626663446288-573.png||class="img-thumbnail" height="125" width="100"]]
37 37  
38 38  **Interface definition of V-BOX S-00**
39 -
40 40  COM1 interface definition
41 41  
42 -(% class="table-bordered" style="margin-left:auto; margin-right:auto; width:679px" %)
37 +(% class="table-bordered" style="width:679px" %)
43 43  |=Pin|=(% style="width: 188px;" %)definition|=(% style="width: 131px;" %)Pin|=(% style="width: 174px;" %)definition
44 44  |1|(% style="width:188px" %)RS422 TX+/RS485 A+|(% style="width:131px" %)2|(% style="width:174px" %)RS232 RXD
45 45  |3|(% style="width:188px" %)RS232 TXD|(% style="width:131px" %)5|(% style="width:174px" %)GND
... ... @@ -48,7 +48,7 @@
48 48  
49 49  COM2 interface definition
50 50  
51 -(% class="table-bordered" style="margin-left:auto; margin-right:auto; width:681px" %)
46 +(% class="table-bordered" style="width:681px" %)
52 52  |=Pin|=(% style="width: 194px;" %)definition|=(% style="width: 132px;" %)Pin|=(% style="width: 170px;" %)definition
53 53  |1|(% style="width:194px" %)RS485 A+|(% style="width:132px" %)2|(% style="width:170px" %)RS232 RXD
54 54  |3|(% style="width:194px" %)RS232 TXD|(% style="width:132px" %)5|(% style="width:170px" %)GND
... ... @@ -55,15 +55,12 @@
55 55  |6|(% style="width:194px" %)RS485 B-|(% style="width:132px" %)7|(% style="width:170px" %)COM3 RS485 A+
56 56  |8|(% style="width:194px" %)COM3 RS485 B-|(% style="width:132px" %) |(% style="width:170px" %)
57 57  
58 -(% class="box infomessage" %)
59 -(((
60 60  **✎Note: **The COM port of V-BOX can only support one communication method at a time.
61 -)))
62 62  
63 63  **Interface definition of V-BOX S-4G**
64 64  COM1 interface definition
65 65  
66 -(% class="table-bordered" style="margin-left:auto; margin-right:auto; width:687px" %)
58 +(% class="table-bordered" style="width:687px" %)
67 67  |=Pin|=(% style="width: 195px;" %)definition|=(% style="width: 137px;" %)Pin|=(% style="width: 169px;" %)definition
68 68  |1|(% style="width:195px" %)RS422 TX+/RS485 A+|(% style="width:137px" %)2|(% style="width:169px" %)RS232 RXD
69 69  |3|(% style="width:195px" %)RS232 TXD|(% style="width:137px" %)5|(% style="width:169px" %)GND
... ... @@ -72,7 +72,7 @@
72 72  
73 73  COM2 interface definition
74 74  
75 -(% class="table-bordered" style="margin-left:auto; margin-right:auto; width:690px" %)
67 +(% class="table-bordered" style="width:690px" %)
76 76  |=Pin|=(% style="width: 195px;" %)definition|=(% style="width: 139px;" %)Pin|=(% style="width: 171px;" %)definition
77 77  |1|(% style="width:195px" %)RS485 A+|(% style="width:139px" %)2|(% style="width:171px" %)RS232 RXD
78 78  |3|(% style="width:195px" %)RS232 TXD|(% style="width:139px" %)5|(% style="width:171px" %)GND
... ... @@ -79,15 +79,12 @@
79 79  |6|(% style="width:195px" %)RS485 B-|(% style="width:139px" %)7|(% style="width:171px" %)COM3 RS485 A+
80 80  |8|(% style="width:195px" %)COM3 RS485 B-|(% style="width:139px" %) |(% style="width:171px" %)
81 81  
82 -(% class="box infomessage" %)
83 -(((
84 84  **✎Note: **The COM port of V-BOX can only support one communication method at a time.
85 -)))
86 86  
87 87  **Interface definition of V-BOX S-AG**
88 88  COM1 interface definition
89 89  
90 -(% class="table-bordered" style="margin-left:auto; margin-right:auto; width:696px" %)
79 +(% class="table-bordered" style="width:696px" %)
91 91  |=Pin|=(% style="width: 194px;" %)definition|=(% style="width: 142px;" %)Pin|=(% style="width: 174px;" %)definition
92 92  |1|(% style="width:194px" %)RS422 TX+/RS485 A+|(% style="width:142px" %)2|(% style="width:174px" %)RS232 RXD
93 93  |3|(% style="width:194px" %)RS232 TXD|(% style="width:142px" %)5|(% style="width:174px" %)GND
... ... @@ -96,7 +96,7 @@
96 96  
97 97  COM2 interface definition
98 98  
99 -(% class="table-bordered" style="margin-left:auto; margin-right:auto; width:694px" %)
88 +(% class="table-bordered" style="width:694px" %)
100 100  |=Pin|=(% style="width: 194px;" %)definition|=(% style="width: 145px;" %)Pin|=(% style="width: 170px;" %)definition
101 101  |1|(% style="width:194px" %)RS485 A+|(% style="width:145px" %)2|(% style="width:170px" %)RS232 RXD
102 102  |3|(% style="width:194px" %)RS232 TXD|(% style="width:145px" %)5|(% style="width:170px" %)GND
... ... @@ -103,15 +103,12 @@
103 103  |6|(% style="width:194px" %)RS485 B-|(% style="width:145px" %)7|(% style="width:170px" %)COM3 RS485 A+
104 104  |8|(% style="width:194px" %)COM3 RS485 B-|(% style="width:145px" %) |(% style="width:170px" %)
105 105  
106 -(% class="box infomessage" %)
107 -(((
108 108  **✎Note: **The COM port of V-BOX can only support one communication method at a time.
109 -)))
110 110  
111 111  **Interface definition of V-BOX S-3N**
112 112  COM1 interface definition
113 113  
114 -(% class="table-bordered" style="margin-left:auto; margin-right:auto; width:701px" %)
100 +(% class="table-bordered" style="width:701px" %)
115 115  |=Pin|=(% style="width: 200px;" %)definition|=(% style="width: 145px;" %)Pin|=(% style="width: 170px;" %)definition
116 116  |1|(% style="width:200px" %)RS422 TX+/RS485 A+|(% style="width:145px" %)2|(% style="width:170px" %)RS232 RXD
117 117  |3|(% style="width:200px" %)RS232 TXD|(% style="width:145px" %)5|(% style="width:170px" %)GND
... ... @@ -118,18 +118,11 @@
118 118  |6|(% style="width:200px" %)RS422 TX-/RS485 B-|(% style="width:145px" %)8|(% style="width:170px" %)RS422 RX-
119 119  |9|(% style="width:200px" %)RS422 RX+|(% style="width:145px" %) |(% style="width:170px" %)
120 120  
121 -(% class="box infomessage" %)
122 -(((
123 -**✎Note: **
124 -
125 -* The RS422 and RS485 communication modes in the COM1 port of V-BOX cannot be used at the same time.
126 -* 485 communication interfaces are all with isolation.
127 -)))
128 -
129 -**Interface definition of V-BOX S-NG**
107 +**✎Note: **1. The RS422 and RS485 communication modes in the COM1 port of V-BOX cannot be used at the same time.
108 +2、485 communication interfaces are all with isolation. **Interface definition of V-BOX S-NG**
130 130  COM1 interface definition
131 131  
132 -(% class="table-bordered" style="margin-left:auto; margin-right:auto; width:706px" %)
111 +(% class="table-bordered" style="width:706px" %)
133 133  |=Pin|=(% style="width: 195px;" %)definition|=(% style="width: 156px;" %)Pin|=(% style="width: 169px;" %)definition
134 134  |1|(% style="width:195px" %)RS422 TX+/RS485 A+|(% style="width:156px" %)2|(% style="width:169px" %)RS232 RXD
135 135  |3|(% style="width:195px" %)RS232 TXD|(% style="width:156px" %)5|(% style="width:169px" %)GND
... ... @@ -136,18 +136,13 @@
136 136  |6|(% style="width:195px" %)RS422 TX-/RS485 B-|(% style="width:156px" %)8|(% style="width:169px" %)RS422 RX-
137 137  |9|(% style="width:195px" %)RS422 RX+|(% style="width:156px" %) |(% style="width:169px" %)
138 138  
139 -(% class="box infomessage" %)
140 -(((
141 -**✎Note: **
118 +**✎Note: **1. The RS422 and RS485 communication modes in the COM1 port of V-BOX cannot be used at the same time。
119 +2、485 communication interfaces are all with isolation.
142 142  
143 -* The RS422 and RS485 communication modes in the COM1 port of V-BOX cannot be used at the same time。
144 -* 485 communication interfaces are all with isolation.
145 -)))
146 -
147 147  **Interface definition of V-BOX E-00**
148 148  COM1 interface definition
149 149  
150 -(% class="table-bordered" style="margin-left:auto; margin-right:auto; width:710px" %)
124 +(% class="table-bordered" style="width:710px" %)
151 151  |=Pin|=(% style="width: 200px;" %)definition|=(% style="width: 161px;" %)Pin|=(% style="width: 163px;" %)definition
152 152  |1|(% style="width:200px" %)RS422 TX+/RS485 A+|(% style="width:161px" %)2|(% style="width:163px" %)RS232 RXD
153 153  |3|(% style="width:200px" %)RS232 TXD|(% style="width:161px" %)5|(% style="width:163px" %)GND
... ... @@ -154,10 +154,5 @@
154 154  |6|(% style="width:200px" %)RS422 TX-/RS485 B-|(% style="width:161px" %)8|(% style="width:163px" %)RS422 RX-
155 155  |9|(% style="width:200px" %)RS422 RX+|(% style="width:161px" %) |(% style="width:163px" %)
156 156  
157 -(% class="box infomessage" %)
158 -(((
159 -**✎Note: **
160 -
161 -* The RS422 and RS485 communication modes in the COM1 port of V-BOX cannot be used at the same time。
162 -* 485 communication interfaces are all with isolation.
163 -)))
131 +**✎Note: **1、The RS422 and RS485 communication modes in the COM1 port of V-BOX cannot be used at the same time.
132 +2、485 communication interfaces are all with isolation.