Wiki source code of 2 V-BOX pin definition
Last modified by Stone Wu on 2022/09/23 07:03
Show last authors
author | version | line-number | content |
---|---|---|---|
1 | = **1 V-BOX pin definition** = | ||
2 | |||
3 | (% style="text-align:center" %) | ||
4 | [[image:1624587334538-981.png||height="113" width="200" class="img-thumbnail"]] | ||
5 | |||
6 | **Interface definition of V-BOX H-00/H-WF/H-AG** | ||
7 | |||
8 | COM1 interface definition | ||
9 | |||
10 | (% class="table-bordered" style="margin-left:auto; margin-right:auto; width:710px" %) | ||
11 | |=Pin|=(% style="width: 200px;" %)definition|=(% style="width: 161px;" %)Pin|=(% style="width: 163px;" %)definition | ||
12 | |1|(% style="width:200px" %)RS422 TX+/RS485 A+|(% style="width:161px" %)2|(% style="width:163px" %)RS232 RXD | ||
13 | |3|(% style="width:200px" %)RS232 TXD|(% style="width:161px" %)5|(% style="width:163px" %)GND | ||
14 | |6|(% style="width:200px" %)RS422 TX-/RS485 B-|(% style="width:161px" %)8|(% style="width:163px" %)RS422 RX- | ||
15 | |9|(% style="width:200px" %)RS422 RX+|(% style="width:161px" %) |(% style="width:163px" %) | ||
16 | |||
17 | (% class="box infomessage" %) | ||
18 | ((( | ||
19 | **✎Note: ** | ||
20 | |||
21 | * The RS422 and RS485 communication Pin in the COM1 cannot be used at the same time. | ||
22 | * RS485 communication interfaces are all with isolation. | ||
23 | ))) | ||
24 | |||
25 | COM2 interface definition | ||
26 | |||
27 | * A1+ ~-~-~-~-~-~-RS485+ | ||
28 | * B1- ~-~-~-~-~-~--RS485- | ||
29 | |||
30 | COM3 interface definition | ||
31 | |||
32 | * A2+ ~-~-~-~-~-~-RS485+ | ||
33 | * B2- ~-~-~-~-~-~--RS485- | ||
34 | |||
35 | (% style="text-align:center" %) | ||
36 | [[image:1626663446288-573.png||height="125" width="100" class="img-thumbnail"]] | ||
37 | |||
38 | **Interface definition of V-BOX S-00** | ||
39 | |||
40 | COM1 interface definition | ||
41 | |||
42 | (% class="table-bordered" style="margin-left:auto; margin-right:auto; width:679px" %) | ||
43 | |=Pin|=(% style="width: 188px;" %)definition|=(% style="width: 131px;" %)Pin|=(% style="width: 174px;" %)definition | ||
44 | |1|(% style="width:188px" %)RS422 TX+/RS485 A+|(% style="width:131px" %)2|(% style="width:174px" %)RS232 RXD | ||
45 | |3|(% style="width:188px" %)RS232 TXD|(% style="width:131px" %)5|(% style="width:174px" %)GND | ||
46 | |6|(% style="width:188px" %)RS422 TX-/RS485 B-|(% style="width:131px" %)8|(% style="width:174px" %)RS422 RX- | ||
47 | |9|(% style="width:188px" %)RS422 RX+|(% style="width:131px" %) |(% style="width:174px" %) | ||
48 | |||
49 | COM2 interface definition | ||
50 | |||
51 | (% class="table-bordered" style="margin-left:auto; margin-right:auto; width:681px" %) | ||
52 | |=Pin|=(% style="width: 194px;" %)definition|=(% style="width: 132px;" %)Pin|=(% style="width: 170px;" %)definition | ||
53 | |1|(% style="width:194px" %)RS485 A+|(% style="width:132px" %)2|(% style="width:170px" %)RS232 RXD | ||
54 | |3|(% style="width:194px" %)RS232 TXD|(% style="width:132px" %)5|(% style="width:170px" %)GND | ||
55 | |6|(% style="width:194px" %)RS485 B-|(% style="width:132px" %)7|(% style="width:170px" %)COM3 RS485 A+ | ||
56 | |8|(% style="width:194px" %)COM3 RS485 B-|(% style="width:132px" %) |(% style="width:170px" %) | ||
57 | |||
58 | (% class="box infomessage" %) | ||
59 | ((( | ||
60 | **✎Note: **The COM port of V-BOX can only support one communication method at a time. | ||
61 | ))) | ||
62 | |||
63 | **Interface definition of V-BOX S-4G** | ||
64 | COM1 interface definition | ||
65 | |||
66 | (% class="table-bordered" style="margin-left:auto; margin-right:auto; width:687px" %) | ||
67 | |=Pin|=(% style="width: 195px;" %)definition|=(% style="width: 137px;" %)Pin|=(% style="width: 169px;" %)definition | ||
68 | |1|(% style="width:195px" %)RS422 TX+/RS485 A+|(% style="width:137px" %)2|(% style="width:169px" %)RS232 RXD | ||
69 | |3|(% style="width:195px" %)RS232 TXD|(% style="width:137px" %)5|(% style="width:169px" %)GND | ||
70 | |6|(% style="width:195px" %)RS422 TX-/RS485 B-|(% style="width:137px" %)8|(% style="width:169px" %)RS422 RX- | ||
71 | |9|(% style="width:195px" %)RS422 RX+|(% style="width:137px" %) |(% style="width:169px" %) | ||
72 | |||
73 | COM2 interface definition | ||
74 | |||
75 | (% class="table-bordered" style="margin-left:auto; margin-right:auto; width:690px" %) | ||
76 | |=Pin|=(% style="width: 195px;" %)definition|=(% style="width: 139px;" %)Pin|=(% style="width: 171px;" %)definition | ||
77 | |1|(% style="width:195px" %)RS485 A+|(% style="width:139px" %)2|(% style="width:171px" %)RS232 RXD | ||
78 | |3|(% style="width:195px" %)RS232 TXD|(% style="width:139px" %)5|(% style="width:171px" %)GND | ||
79 | |6|(% style="width:195px" %)RS485 B-|(% style="width:139px" %)7|(% style="width:171px" %)COM3 RS485 A+ | ||
80 | |8|(% style="width:195px" %)COM3 RS485 B-|(% style="width:139px" %) |(% style="width:171px" %) | ||
81 | |||
82 | (% class="box infomessage" %) | ||
83 | ((( | ||
84 | **✎Note: **The COM port of V-BOX can only support one communication method at a time. | ||
85 | ))) | ||
86 | |||
87 | **Interface definition of V-BOX S-AG** | ||
88 | COM1 interface definition | ||
89 | |||
90 | (% class="table-bordered" style="margin-left:auto; margin-right:auto; width:696px" %) | ||
91 | |=Pin|=(% style="width: 194px;" %)definition|=(% style="width: 142px;" %)Pin|=(% style="width: 174px;" %)definition | ||
92 | |1|(% style="width:194px" %)RS422 TX+/RS485 A+|(% style="width:142px" %)2|(% style="width:174px" %)RS232 RXD | ||
93 | |3|(% style="width:194px" %)RS232 TXD|(% style="width:142px" %)5|(% style="width:174px" %)GND | ||
94 | |6|(% style="width:194px" %)RS422 TX-/RS485 B-|(% style="width:142px" %)8|(% style="width:174px" %)RS422 RX- | ||
95 | |9|(% style="width:194px" %)RS422 RX+|(% style="width:142px" %) |(% style="width:174px" %) | ||
96 | |||
97 | COM2 interface definition | ||
98 | |||
99 | (% class="table-bordered" style="margin-left:auto; margin-right:auto; width:694px" %) | ||
100 | |=Pin|=(% style="width: 194px;" %)definition|=(% style="width: 145px;" %)Pin|=(% style="width: 170px;" %)definition | ||
101 | |1|(% style="width:194px" %)RS485 A+|(% style="width:145px" %)2|(% style="width:170px" %)RS232 RXD | ||
102 | |3|(% style="width:194px" %)RS232 TXD|(% style="width:145px" %)5|(% style="width:170px" %)GND | ||
103 | |6|(% style="width:194px" %)RS485 B-|(% style="width:145px" %)7|(% style="width:170px" %)COM3 RS485 A+ | ||
104 | |8|(% style="width:194px" %)COM3 RS485 B-|(% style="width:145px" %) |(% style="width:170px" %) | ||
105 | |||
106 | (% class="box infomessage" %) | ||
107 | ((( | ||
108 | **✎Note: **The COM port of V-BOX can only support one communication method at a time. | ||
109 | ))) | ||
110 | |||
111 | **Interface definition of V-BOX S-3N** | ||
112 | COM1 interface definition | ||
113 | |||
114 | (% class="table-bordered" style="margin-left:auto; margin-right:auto; width:701px" %) | ||
115 | |=Pin|=(% style="width: 200px;" %)definition|=(% style="width: 145px;" %)Pin|=(% style="width: 170px;" %)definition | ||
116 | |1|(% style="width:200px" %)RS422 TX+/RS485 A+|(% style="width:145px" %)2|(% style="width:170px" %)RS232 RXD | ||
117 | |3|(% style="width:200px" %)RS232 TXD|(% style="width:145px" %)5|(% style="width:170px" %)GND | ||
118 | |6|(% style="width:200px" %)RS422 TX-/RS485 B-|(% style="width:145px" %)8|(% style="width:170px" %)RS422 RX- | ||
119 | |9|(% style="width:200px" %)RS422 RX+|(% style="width:145px" %) |(% style="width:170px" %) | ||
120 | |||
121 | (% class="box infomessage" %) | ||
122 | ((( | ||
123 | **✎Note: ** | ||
124 | |||
125 | * The RS422 and RS485 communication modes in the COM1 port of V-BOX cannot be used at the same time. | ||
126 | * 485 communication interfaces are all with isolation. | ||
127 | ))) | ||
128 | |||
129 | **Interface definition of V-BOX S-NG** | ||
130 | COM1 interface definition | ||
131 | |||
132 | (% class="table-bordered" style="margin-left:auto; margin-right:auto; width:706px" %) | ||
133 | |=Pin|=(% style="width: 195px;" %)definition|=(% style="width: 156px;" %)Pin|=(% style="width: 169px;" %)definition | ||
134 | |1|(% style="width:195px" %)RS422 TX+/RS485 A+|(% style="width:156px" %)2|(% style="width:169px" %)RS232 RXD | ||
135 | |3|(% style="width:195px" %)RS232 TXD|(% style="width:156px" %)5|(% style="width:169px" %)GND | ||
136 | |6|(% style="width:195px" %)RS422 TX-/RS485 B-|(% style="width:156px" %)8|(% style="width:169px" %)RS422 RX- | ||
137 | |9|(% style="width:195px" %)RS422 RX+|(% style="width:156px" %) |(% style="width:169px" %) | ||
138 | |||
139 | (% class="box infomessage" %) | ||
140 | ((( | ||
141 | **✎Note: ** | ||
142 | |||
143 | * The RS422 and RS485 communication modes in the COM1 port of V-BOX cannot be used at the same time。 | ||
144 | * 485 communication interfaces are all with isolation. | ||
145 | ))) | ||
146 | |||
147 | **Interface definition of V-BOX E-00** | ||
148 | COM1 interface definition | ||
149 | |||
150 | (% class="table-bordered" style="margin-left:auto; margin-right:auto; width:710px" %) | ||
151 | |=Pin|=(% style="width: 200px;" %)definition|=(% style="width: 161px;" %)Pin|=(% style="width: 163px;" %)definition | ||
152 | |1|(% style="width:200px" %)RS422 TX+/RS485 A+|(% style="width:161px" %)2|(% style="width:163px" %)RS232 RXD | ||
153 | |3|(% style="width:200px" %)RS232 TXD|(% style="width:161px" %)5|(% style="width:163px" %)GND | ||
154 | |6|(% style="width:200px" %)RS422 TX-/RS485 B-|(% style="width:161px" %)8|(% style="width:163px" %)RS422 RX- | ||
155 | |9|(% style="width:200px" %)RS422 RX+|(% style="width:161px" %) |(% style="width:163px" %) | ||
156 | |||
157 | (% class="box infomessage" %) | ||
158 | ((( | ||
159 | **✎Note: ** | ||
160 | |||
161 | * The RS422 and RS485 communication modes in the COM1 port of V-BOX cannot be used at the same time。 | ||
162 | * 485 communication interfaces are all with isolation. | ||