| 1 | = **1 V-BOX pin definition** = | ||
| 2 | |||
| 3 | (% style="text-align:center" %) | ||
| 4 | [[image:1624587334538-981.png||height="113" width="200" class="img-thumbnail"]] | ||
| 5 | |||
| 6 | **Interface definition of V-BOX H-00/H-WF/H-AG** | ||
| 7 | |||
| 8 | COM1 interface definition | ||
| 9 | |||
| 10 | (% class="table-bordered" style="margin-left:auto; margin-right:auto; width:710px" %) | ||
| 11 | |=Pin|=(% style="width: 200px;" %)definition|=(% style="width: 161px;" %)Pin|=(% style="width: 163px;" %)definition | ||
| 12 | |1|(% style="width:200px" %)RS422 TX+/RS485 A+|(% style="width:161px" %)2|(% style="width:163px" %)RS232 RXD | ||
| 13 | |3|(% style="width:200px" %)RS232 TXD|(% style="width:161px" %)5|(% style="width:163px" %)GND | ||
| 14 | |6|(% style="width:200px" %)RS422 TX-/RS485 B-|(% style="width:161px" %)8|(% style="width:163px" %)RS422 RX- | ||
| 15 | |9|(% style="width:200px" %)RS422 RX+|(% style="width:161px" %) |(% style="width:163px" %) | ||
| 16 | |||
| 17 | (% class="box infomessage" %) | ||
| 18 | ((( | ||
| 19 | **✎Note: ** | ||
| 20 | |||
| 21 | * The RS422 and RS485 communication Pin in the COM1 cannot be used at the same time. | ||
| 22 | * RS485 communication interfaces are all with isolation. | ||
| 23 | ))) | ||
| 24 | |||
| 25 | COM2 interface definition | ||
| 26 | |||
| 27 | * A1+ ~-~-~-~-~-~-RS485+ | ||
| 28 | * B1- ~-~-~-~-~-~--RS485- | ||
| 29 | |||
| 30 | COM3 interface definition | ||
| 31 | |||
| 32 | * A2+ ~-~-~-~-~-~-RS485+ | ||
| 33 | * B2- ~-~-~-~-~-~--RS485- | ||
| 34 | |||
| 35 | (% style="text-align:center" %) | ||
| 36 | [[image:1626663446288-573.png||height="125" width="100" class="img-thumbnail"]] | ||
| 37 | |||
| 38 | **Interface definition of V-BOX S-00** | ||
| 39 | |||
| 40 | COM1 interface definition | ||
| 41 | |||
| 42 | (% class="table-bordered" style="margin-left:auto; margin-right:auto; width:679px" %) | ||
| 43 | |=Pin|=(% style="width: 188px;" %)definition|=(% style="width: 131px;" %)Pin|=(% style="width: 174px;" %)definition | ||
| 44 | |1|(% style="width:188px" %)RS422 TX+/RS485 A+|(% style="width:131px" %)2|(% style="width:174px" %)RS232 RXD | ||
| 45 | |3|(% style="width:188px" %)RS232 TXD|(% style="width:131px" %)5|(% style="width:174px" %)GND | ||
| 46 | |6|(% style="width:188px" %)RS422 TX-/RS485 B-|(% style="width:131px" %)8|(% style="width:174px" %)RS422 RX- | ||
| 47 | |9|(% style="width:188px" %)RS422 RX+|(% style="width:131px" %) |(% style="width:174px" %) | ||
| 48 | |||
| 49 | COM2 interface definition | ||
| 50 | |||
| 51 | (% class="table-bordered" style="margin-left:auto; margin-right:auto; width:681px" %) | ||
| 52 | |=Pin|=(% style="width: 194px;" %)definition|=(% style="width: 132px;" %)Pin|=(% style="width: 170px;" %)definition | ||
| 53 | |1|(% style="width:194px" %)RS485 A+|(% style="width:132px" %)2|(% style="width:170px" %)RS232 RXD | ||
| 54 | |3|(% style="width:194px" %)RS232 TXD|(% style="width:132px" %)5|(% style="width:170px" %)GND | ||
| 55 | |6|(% style="width:194px" %)RS485 B-|(% style="width:132px" %)7|(% style="width:170px" %)COM3 RS485 A+ | ||
| 56 | |8|(% style="width:194px" %)COM3 RS485 B-|(% style="width:132px" %) |(% style="width:170px" %) | ||
| 57 | |||
| 58 | (% class="box infomessage" %) | ||
| 59 | ((( | ||
| 60 | **✎Note: **The COM port of V-BOX can only support one communication method at a time. | ||
| 61 | ))) | ||
| 62 | |||
| 63 | **Interface definition of V-BOX S-4G** | ||
| 64 | COM1 interface definition | ||
| 65 | |||
| 66 | (% class="table-bordered" style="margin-left:auto; margin-right:auto; width:687px" %) | ||
| 67 | |=Pin|=(% style="width: 195px;" %)definition|=(% style="width: 137px;" %)Pin|=(% style="width: 169px;" %)definition | ||
| 68 | |1|(% style="width:195px" %)RS422 TX+/RS485 A+|(% style="width:137px" %)2|(% style="width:169px" %)RS232 RXD | ||
| 69 | |3|(% style="width:195px" %)RS232 TXD|(% style="width:137px" %)5|(% style="width:169px" %)GND | ||
| 70 | |6|(% style="width:195px" %)RS422 TX-/RS485 B-|(% style="width:137px" %)8|(% style="width:169px" %)RS422 RX- | ||
| 71 | |9|(% style="width:195px" %)RS422 RX+|(% style="width:137px" %) |(% style="width:169px" %) | ||
| 72 | |||
| 73 | COM2 interface definition | ||
| 74 | |||
| 75 | (% class="table-bordered" style="margin-left:auto; margin-right:auto; width:690px" %) | ||
| 76 | |=Pin|=(% style="width: 195px;" %)definition|=(% style="width: 139px;" %)Pin|=(% style="width: 171px;" %)definition | ||
| 77 | |1|(% style="width:195px" %)RS485 A+|(% style="width:139px" %)2|(% style="width:171px" %)RS232 RXD | ||
| 78 | |3|(% style="width:195px" %)RS232 TXD|(% style="width:139px" %)5|(% style="width:171px" %)GND | ||
| 79 | |6|(% style="width:195px" %)RS485 B-|(% style="width:139px" %)7|(% style="width:171px" %)COM3 RS485 A+ | ||
| 80 | |8|(% style="width:195px" %)COM3 RS485 B-|(% style="width:139px" %) |(% style="width:171px" %) | ||
| 81 | |||
| 82 | (% class="box infomessage" %) | ||
| 83 | ((( | ||
| 84 | **✎Note: **The COM port of V-BOX can only support one communication method at a time. | ||
| 85 | ))) | ||
| 86 | |||
| 87 | **Interface definition of V-BOX S-AG** | ||
| 88 | COM1 interface definition | ||
| 89 | |||
| 90 | (% class="table-bordered" style="margin-left:auto; margin-right:auto; width:696px" %) | ||
| 91 | |=Pin|=(% style="width: 194px;" %)definition|=(% style="width: 142px;" %)Pin|=(% style="width: 174px;" %)definition | ||
| 92 | |1|(% style="width:194px" %)RS422 TX+/RS485 A+|(% style="width:142px" %)2|(% style="width:174px" %)RS232 RXD | ||
| 93 | |3|(% style="width:194px" %)RS232 TXD|(% style="width:142px" %)5|(% style="width:174px" %)GND | ||
| 94 | |6|(% style="width:194px" %)RS422 TX-/RS485 B-|(% style="width:142px" %)8|(% style="width:174px" %)RS422 RX- | ||
| 95 | |9|(% style="width:194px" %)RS422 RX+|(% style="width:142px" %) |(% style="width:174px" %) | ||
| 96 | |||
| 97 | COM2 interface definition | ||
| 98 | |||
| 99 | (% class="table-bordered" style="margin-left:auto; margin-right:auto; width:694px" %) | ||
| 100 | |=Pin|=(% style="width: 194px;" %)definition|=(% style="width: 145px;" %)Pin|=(% style="width: 170px;" %)definition | ||
| 101 | |1|(% style="width:194px" %)RS485 A+|(% style="width:145px" %)2|(% style="width:170px" %)RS232 RXD | ||
| 102 | |3|(% style="width:194px" %)RS232 TXD|(% style="width:145px" %)5|(% style="width:170px" %)GND | ||
| 103 | |6|(% style="width:194px" %)RS485 B-|(% style="width:145px" %)7|(% style="width:170px" %)COM3 RS485 A+ | ||
| 104 | |8|(% style="width:194px" %)COM3 RS485 B-|(% style="width:145px" %) |(% style="width:170px" %) | ||
| 105 | |||
| 106 | (% class="box infomessage" %) | ||
| 107 | ((( | ||
| 108 | **✎Note: **The COM port of V-BOX can only support one communication method at a time. | ||
| 109 | ))) | ||
| 110 | |||
| 111 | **Interface definition of V-BOX S-3N** | ||
| 112 | COM1 interface definition | ||
| 113 | |||
| 114 | (% class="table-bordered" style="margin-left:auto; margin-right:auto; width:701px" %) | ||
| 115 | |=Pin|=(% style="width: 200px;" %)definition|=(% style="width: 145px;" %)Pin|=(% style="width: 170px;" %)definition | ||
| 116 | |1|(% style="width:200px" %)RS422 TX+/RS485 A+|(% style="width:145px" %)2|(% style="width:170px" %)RS232 RXD | ||
| 117 | |3|(% style="width:200px" %)RS232 TXD|(% style="width:145px" %)5|(% style="width:170px" %)GND | ||
| 118 | |6|(% style="width:200px" %)RS422 TX-/RS485 B-|(% style="width:145px" %)8|(% style="width:170px" %)RS422 RX- | ||
| 119 | |9|(% style="width:200px" %)RS422 RX+|(% style="width:145px" %) |(% style="width:170px" %) | ||
| 120 | |||
| 121 | (% class="box infomessage" %) | ||
| 122 | ((( | ||
| 123 | **✎Note: ** | ||
| 124 | |||
| 125 | * The RS422 and RS485 communication modes in the COM1 port of V-BOX cannot be used at the same time. | ||
| 126 | * 485 communication interfaces are all with isolation. | ||
| 127 | ))) | ||
| 128 | |||
| 129 | **Interface definition of V-BOX S-NG** | ||
| 130 | COM1 interface definition | ||
| 131 | |||
| 132 | (% class="table-bordered" style="margin-left:auto; margin-right:auto; width:706px" %) | ||
| 133 | |=Pin|=(% style="width: 195px;" %)definition|=(% style="width: 156px;" %)Pin|=(% style="width: 169px;" %)definition | ||
| 134 | |1|(% style="width:195px" %)RS422 TX+/RS485 A+|(% style="width:156px" %)2|(% style="width:169px" %)RS232 RXD | ||
| 135 | |3|(% style="width:195px" %)RS232 TXD|(% style="width:156px" %)5|(% style="width:169px" %)GND | ||
| 136 | |6|(% style="width:195px" %)RS422 TX-/RS485 B-|(% style="width:156px" %)8|(% style="width:169px" %)RS422 RX- | ||
| 137 | |9|(% style="width:195px" %)RS422 RX+|(% style="width:156px" %) |(% style="width:169px" %) | ||
| 138 | |||
| 139 | (% class="box infomessage" %) | ||
| 140 | ((( | ||
| 141 | **✎Note: ** | ||
| 142 | |||
| 143 | * The RS422 and RS485 communication modes in the COM1 port of V-BOX cannot be used at the same time。 | ||
| 144 | * 485 communication interfaces are all with isolation. | ||
| 145 | ))) | ||
| 146 | |||
| 147 | **Interface definition of V-BOX E-00** | ||
| 148 | COM1 interface definition | ||
| 149 | |||
| 150 | (% class="table-bordered" style="margin-left:auto; margin-right:auto; width:710px" %) | ||
| 151 | |=Pin|=(% style="width: 200px;" %)definition|=(% style="width: 161px;" %)Pin|=(% style="width: 163px;" %)definition | ||
| 152 | |1|(% style="width:200px" %)RS422 TX+/RS485 A+|(% style="width:161px" %)2|(% style="width:163px" %)RS232 RXD | ||
| 153 | |3|(% style="width:200px" %)RS232 TXD|(% style="width:161px" %)5|(% style="width:163px" %)GND | ||
| 154 | |6|(% style="width:200px" %)RS422 TX-/RS485 B-|(% style="width:161px" %)8|(% style="width:163px" %)RS422 RX- | ||
| 155 | |9|(% style="width:200px" %)RS422 RX+|(% style="width:161px" %) |(% style="width:163px" %) | ||
| 156 | |||
| 157 | (% class="box infomessage" %) | ||
| 158 | ((( | ||
| 159 | **✎Note: ** | ||