Changes for page 1.8 Remote download
Last modified by Joe on 2024/11/23 09:06
From version 4.3
edited by Stone Wu
on 2022/08/01 09:59
on 2022/08/01 09:59
Change comment:
Renamed from xwiki:V-BOX.V-Net.01 V-NET Platform.09 Remote download.WebHome
To version 11.1
edited by Theodore Xu
on 2024/04/02 14:36
on 2024/04/02 14:36
Change comment:
There is no comment for this version
Summary
-
Page properties (4 modified, 0 added, 0 removed)
-
Attachments (0 modified, 7 added, 0 removed)
Details
- Page properties
-
- Title
-
... ... @@ -1,1 +1,1 @@ 1 - 09Remote download1 +1.8 Remote download - Parent
-
... ... @@ -1,1 +1,1 @@ 1 -V-BOX.V-Net.01 V-NET Platform.WebHome 1 +V-BOX.V-Net.Manual.01 V-NET Platform.WebHome - Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Stone1 +XWiki.AiXia - Content
-
... ... @@ -1,4 +1,4 @@ 1 -The function of pass-through allows applications on the computer to remotely pass-through the device, download projects, etc., via the V-BOX or ig screen.1 +The function of pass-through allows applications on the computer to remotely pass-through the device, download projects, etc., via the V-BOX or ig HMI. 2 2 3 3 (% style="text-align:center" %) 4 4 [[image:9-1.png||class="img-thumbnail"]] ... ... @@ -5,34 +5,40 @@ 5 5 6 6 = **PLC Download** = 7 7 8 -Through the V-NET PC software, remotely pass-through the V-BOX or IIoTigscreen(the PLC remote download procedure is the same) to directly control the PLC devices, including upload, download, and monitor PLC programs.8 +Through the V-NET PC software, remotely pass-through the V-BOX or ig HMI (the PLC remote download procedure is the same) to directly control the PLC devices, including upload, download, and monitor PLC programs. 9 9 10 -== ** COM port** ==10 +== **Remote Download** == 11 11 12 -When installingthesoftware for the first time,usersneedtorestartthe computer to prevent the virtualserial port nodefrombeingincorrect. PLC softwaremay notbe able toidentify thevirtual serial port. After the softwareis successfully installed,thevirtualserialport is displayedindevice Manager, as shownbelow.12 +When operating Pass-through, V-BOX and ig HMI should be connected to the network, and ensure normal communication with PLC. 13 13 14 +If the virtual serial port is set successfully, the system automatically updates the enabled virtual serial port. Fill in the device information, choose COM1 or COM2 as the communication port. When the information filled in is the same as the PLC, Click the button "Pass-thrrough". 15 + 16 +If the Pass-through succeeds, the current status changes to **"running"**, and all the filling information becomes gray and could not be filled, and only the function button **"stop"** is left indicating that the pass-through is successful. 17 + 18 +Click the setting button [[image:穿透穿透图标.png||alt="3.png"]] of the V-NET Client to create the Pass-through configuration. please make sure that V-BOX configuration the same Pass-through according to the communication protocol. 19 + 14 14 (% style="text-align:center" %) 15 -[[image: 9-2.png||class="img-thumbnail"]]21 +[[image:串口穿透设置2.png]] 16 16 17 - Click the setting button [[image:3.png]] in the upper right corner of the PC software to view the COM port configuration used for PLC downloads and Pass-through.The marked areais. ThisCOM port is the same virtual serial port as the device manager. as shown below.23 +This COM port is the same virtual serial port as the device manager. as shown below. 18 18 19 19 (% style="text-align:center" %) 20 -[[image:9 -3.png||class="img-thumbnail"]]26 +[[image:1712028598316.jpg]] 21 21 22 -== **Remote download configuration** == 28 +(% style="text-align:center" %) 29 +[[image:虚拟串口.png]] 23 23 24 - When operatingpass-through,V-BOX and IG screen should beconnectedto thenetwork,andensurenormalcommunicationwithPLC.31 +Option to replace the virtual COM port in the software. 25 25 26 -If the virtual serial port is set successfully, the system automatically updates the enabled virtual serial port. Fill in the device information, choose COM1 or COM2 as the communication port. When the information filled in is the same as the PLC, Click the button [[image:9.4.png]] 33 +(% style="text-align:center" %) 34 +[[image:虚拟串口修改.png]] 27 27 28 - Ifthepass-through succeeds, the current status changes to **"running"**, and all the filling information becomes gray and could not be filled, and only the function button **"stop"** is left indicating that the pass-through is successful.36 +== == 29 29 38 + 30 30 (% style="text-align:center" %) 31 31 [[image:9-4.png||height="475" width="505" class="img-thumbnail"]] 32 32 33 -(% style="text-align:center" %) 34 -[[image:9-4 2.png||height="583" width="504" class="img-thumbnail"]] 35 - 36 36 The descriptions of the remote download page are as follows. 37 37 38 38 1. **Status. **Display the statuses of the device, including ready to pass-through, pass-through is in progress.
- 1712028494273-430.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +3.8 KB - Content
- 1712028598316.jpg
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +3.1 KB - Content
- 串口穿透设置.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +51.3 KB - Content
- 串口穿透设置2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +51.3 KB - Content
- 穿透穿透图标.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +616 bytes - Content
- 虚拟串口.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +17.4 KB - Content
- 虚拟串口修改.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +43.0 KB - Content