Changes for page 1.8 Remote download
Last modified by Joe on 2024/11/23 09:06
From version 5.1
edited by Theodore Xu
on 2024/02/04 15:33
on 2024/02/04 15:33
Change comment:
There is no comment for this version
To version 6.1
edited by Theodore Xu
on 2024/04/02 11:43
on 2024/04/02 11:43
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 7 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,4 +1,4 @@ 1 -The function of pass-through allows applications on the computer to remotely pass-through the device, download projects, etc., via the V-BOX or ig screen.1 +The function of pass-through allows applications on the computer to remotely pass-through the device, download projects, etc., via the V-BOX or ig HMI. 2 2 3 3 (% style="text-align:center" %) 4 4 [[image:9-1.png||class="img-thumbnail"]] ... ... @@ -5,20 +5,27 @@ 5 5 6 6 = **PLC Download** = 7 7 8 -Through the V-NET PC software, remotely pass-through the V-BOX or IIoTigscreen(the PLC remote download procedure is the same) to directly control the PLC devices, including upload, download, and monitor PLC programs.8 +Through the V-NET PC software, remotely pass-through the V-BOX or ig HMI (the PLC remote download procedure is the same) to directly control the PLC devices, including upload, download, and monitor PLC programs. 9 9 10 -== **COM port** ==10 +== **COM Port** == 11 11 12 - Wheninstalling the softwareforthefirsttime, usersneedto restart thecomputertoprevent thevirtualserialportnodefrom being incorrect. PLCsoftware may not beable toidentifythevirtualserialport. After the softwareisessfullyinstalled,thevirtual serial ports displayed indevice Manager, as shown below.12 +Click the setting button [[image:穿透穿透图标.png||alt="3.png"]] of the V-NET Client to create the Pass-through configuration used for PLC downloads. Before use, please make sure that V-BOX communicates normally with PLC, and configure the same Pass-through according to the communication protocol. 13 13 14 14 (% style="text-align:center" %) 15 -[[image: 9-2.png||class="img-thumbnail"]]15 +[[image:串口穿透设置2.png]] 16 16 17 -Click the setting button [[image:3.png]] in the upper right corner of the PC software to view the COM port configuration used for PLC downloads and Pass-through. The marked area is. This COM port is the same virtual serial port as the device manager. as shown below. 18 18 18 +This COM port is the same virtual serial port as the device manager. as shown below. 19 + 19 19 (% style="text-align:center" %) 20 -[[image: 9-3.png||class="img-thumbnail"]]21 +[[image:虚拟串口.png]] 21 21 23 +(% style="text-align:center" %) 24 +[[image:虚拟串口修改.png]] 25 + 26 +(% style="text-align:center" %) 27 +[[image:1712028598316.jpg]] 28 + 22 22 == **Remote download configuration** == 23 23 24 24 When operating pass-through, V-BOX and IG screen should be connected to the network, and ensure normal communication with PLC.
- 1712028494273-430.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +3.8 KB - Content
- 1712028598316.jpg
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +3.1 KB - Content
- 串口穿透设置.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +51.3 KB - Content
- 串口穿透设置2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +51.3 KB - Content
- 穿透穿透图标.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +616 bytes - Content
- 虚拟串口.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +17.4 KB - Content
- 虚拟串口修改.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +43.0 KB - Content