Changes for page 1.8 Remote download
Last modified by Joe on 2024/11/23 09:06
From version 6.1
edited by Theodore Xu
on 2024/04/02 11:43
on 2024/04/02 11:43
Change comment:
There is no comment for this version
Summary
-
Page properties (4 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 7 removed)
Details
- Page properties
-
- Title
-
... ... @@ -1,1 +1,1 @@ 1 - 1.8Remote download1 +09 Remote download - Parent
-
... ... @@ -1,1 +1,1 @@ 1 -V-BOX.V-Net.Manual.01 V-NET Platform.WebHome1 +V-BOX.V-Net.1\.User Manual.01 V-NET.WebHome - Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. AiXia1 +XWiki.admin - Content
-
... ... @@ -1,33 +1,26 @@ 1 -The function of pass-through allows applications on the computer to remotely pass-through the device, download projects, etc., via the V-BOX or ig HMI.1 +The function of pass-through allows applications on the computer to remotely pass-through the device, download projects, etc., via the V-BOX or ig screen. 2 2 3 3 (% style="text-align:center" %) 4 4 [[image:9-1.png||class="img-thumbnail"]] 5 5 6 -= **PLC Download** = 6 += **9.1 PLC Download** = 7 7 8 -Through the V-NET PC software, remotely pass-through the V-BOX or ig HMI(the PLC remote download procedure is the same) to directly control the PLC devices, including upload, download, and monitor PLC programs.8 +Through the V-NET PC software, remotely pass-through the V-BOX or IIoT ig screen (the PLC remote download procedure is the same) to directly control the PLC devices, including upload, download, and monitor PLC programs. 9 9 10 -== **COM Port** ==10 +== **9.1.1 The COM port** == 11 11 12 - Click the settingbutton[[image:穿透穿透图标.png||alt="3.png"]]of theV-NETClienttocreatethePass-throughconfiguration usedforPLC downloads. Beforeuse,please makesurethatV-BOX communicatesnormallywith PLC,andconfigure the samePass-through accordingtothecommunicationprotocol.12 +When installing the software for the first time, users need to restart the computer to prevent the virtual serial port node from being incorrect. PLC software may not be able to identify the virtual serial port. After the software is successfully installed, the virtual serial port is displayed in device Manager, as shown below. 13 13 14 14 (% style="text-align:center" %) 15 -[[image: 串口穿透设置2.png]]15 +[[image:9-2.png||class="img-thumbnail"]] 16 16 17 +Click the setting button [[image:3.png]] in the upper right corner of the PC software to view the COM port configuration used for PLC downloads and Pass-through. The marked area is. This COM port is the same virtual serial port as the device manager. as shown below. 17 17 18 -This COM port is the same virtual serial port as the device manager. as shown below. 19 - 20 20 (% style="text-align:center" %) 21 -[[image: 虚拟串口.png]]20 +[[image:9-3.png||class="img-thumbnail"]] 22 22 23 -(% style="text-align:center" %) 24 -[[image:虚拟串口修改.png]] 22 +== **9.1.2 Remote download configuration** == 25 25 26 -(% style="text-align:center" %) 27 -[[image:1712028598316.jpg]] 28 - 29 -== **Remote download configuration** == 30 - 31 31 When operating pass-through, V-BOX and IG screen should be connected to the network, and ensure normal communication with PLC. 32 32 33 33 If the virtual serial port is set successfully, the system automatically updates the enabled virtual serial port. Fill in the device information, choose COM1 or COM2 as the communication port. When the information filled in is the same as the PLC, Click the button [[image:9.4.png]] ... ... @@ -35,10 +35,10 @@ 35 35 If the pass-through succeeds, the current status changes to **"running"**, and all the filling information becomes gray and could not be filled, and only the function button **"stop"** is left indicating that the pass-through is successful. 36 36 37 37 (% style="text-align:center" %) 38 -[[image:9-4.png||height="475" width="505" class="img-thumbnail"]]31 +[[image:9-4.png||class="img-thumbnail" height="475" width="505"]] 39 39 40 40 (% style="text-align:center" %) 41 -[[image:9-4 2.png||height="583" width="504" class="img-thumbnail"]]34 +[[image:9-4 2.png||class="img-thumbnail" height="583" width="504"]] 42 42 43 43 The descriptions of the remote download page are as follows. 44 44 ... ... @@ -56,7 +56,7 @@ 56 56 1. **Delete. **To delete the saved settings. 57 57 1. **Stop. **To stop pass-through. 58 58 59 -== **Transport Settings** == 52 +== **9.1.3 Transport Settings** == 60 60 61 61 Here is the example of LX3VE. Click **[[here>>https://www.we-con.com.cn/en/service.html]]** to download the PLC programming software of Wecon "**Wecon PLC Editor".** 62 62 ... ... @@ -65,7 +65,7 @@ 65 65 (% style="text-align:center" %) 66 66 [[image:9-5.png||class="img-thumbnail"]] 67 67 68 -== **PLC upload** == 61 +== **9.1.4 PLC upload** == 69 69 70 70 (1) Select "**Read from PLC**"-"**Parameter+program**", click "**Execute**" to upload the program of PLC to the PC. As shown below. 71 71 ... ... @@ -77,7 +77,7 @@ 77 77 (% style="text-align:center" %) 78 78 [[image:9-7 3.png||class="img-thumbnail"]] 79 79 80 -== **PLC download** == 73 +== **9.1.5 PLC download** == 81 81 82 82 (1) Select **"Write to PLC"-"Parameter+program"**, click **"Execute" **to download the program to the PLC. As shown below. 83 83 ... ... @@ -89,7 +89,7 @@ 89 89 (% style="text-align:center" %) 90 90 [[image:9-9.png||class="img-thumbnail"]] 91 91 92 -== **Monitor mode** == 85 +== **9.1.6 Monitor mode** == 93 93 94 94 Open the PLC software on PC, and open a PLC program or an uploaded program, select **"Monitor mode" **to monitor the status of the ladder diagram. As shown below. 95 95 ... ... @@ -96,7 +96,7 @@ 96 96 (% style="text-align:center" %) 97 97 [[image:9-10.png||class="img-thumbnail"]] 98 98 99 -== **Stop pass-through** == 92 +== **9.1.7 Stop pass-through** == 100 100 101 101 If the operation of PLC is complete, the connection between PC and PLC software should be terminated first, and the V-BOX would restart automatically. As shown below. 102 102 ... ... @@ -103,9 +103,9 @@ 103 103 (% style="text-align:center" %) 104 104 [[image:9-4 2.png||class="img-thumbnail"]] 105 105 106 -= **HMI download** = 99 += **9.2 HMI download** = 107 107 108 -== **Download configuration** == 101 +== **9.2.1 Download configuration** == 109 109 110 110 Users could click [[here>>https://www.we-con.com.cn/en/service.html]] to download the software **"PIStudio". **If the account is logged in for the first time, users need to click the Settings button [[image:3.png]] on the upper right corner of the software to configure the virtual serial port parameters. The COM port used during pass-through is a virtual serial port. After setting successfully once, there is no need to repeat this step again. 111 111 ... ... @@ -112,7 +112,7 @@ 112 112 (% style="text-align:center" %) 113 113 [[image:9-12.png||class="img-thumbnail"]] 114 114 115 -== **HMI download** == 108 +== **9.2.2 HMI download** == 116 116 117 117 During the pass-through, the HMI should be online. When the status is ready, and the download configuration is complete, click the button [[image:9-13 1.png]] 118 118 ... ... @@ -125,7 +125,7 @@ 125 125 (% style="text-align:center" %) 126 126 [[image:9-14.png||class="img-thumbnail"]] 127 127 128 -== **Stop remote** == 121 +== **9.2.3 Stop remote** == 129 129 130 130 When the download is complete, the HMI would restart automatically. If users need to download again, click** "Restart" **or** "End remote". **As shown below. 131 131
- 1712028494273-430.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.AiXia - Size
-
... ... @@ -1,1 +1,0 @@ 1 -3.8 KB - Content
- 1712028598316.jpg
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.AiXia - Size
-
... ... @@ -1,1 +1,0 @@ 1 -3.1 KB - Content
- 串口穿透设置.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.AiXia - Size
-
... ... @@ -1,1 +1,0 @@ 1 -51.3 KB - Content
- 串口穿透设置2.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.AiXia - Size
-
... ... @@ -1,1 +1,0 @@ 1 -51.3 KB - Content
- 穿透穿透图标.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.AiXia - Size
-
... ... @@ -1,1 +1,0 @@ 1 -616 bytes - Content
- 虚拟串口.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.AiXia - Size
-
... ... @@ -1,1 +1,0 @@ 1 -17.4 KB - Content
- 虚拟串口修改.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.AiXia - Size
-
... ... @@ -1,1 +1,0 @@ 1 -43.0 KB - Content