Changes for page 01 Lua Functions
Last modified by Theodore Xu on 2023/10/26 10:51
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1370,7 +1370,6 @@ 1370 1370 ))) 1371 1371 1372 1372 1373 - 1374 1374 ((( 1375 1375 == **Data storage area(HDW/HDX)** == 1376 1376 ))) ... ... @@ -1501,17 +1501,27 @@ 1501 1501 ** addr_getstring("@W_HSW225",15) 1502 1502 1503 1503 ((( 1503 +== **Power-down storage area (HAW/HAX)** == 1504 + 1505 +The system storage area (HAW) is used for the system power-down hold registers: 1506 + 1507 +1. Accessed as a word, numbered in the range: "@W_HAW0"-"@W_HAW199999". 1508 +1. Accessed by bit, the numbering range is: "@B_HAX0.0"-"@B_HAX199999.15". 1509 + 1510 +(% class="box infomessage" %) 1511 +((( 1512 +**✎Note:** HAW/HAX is a power-down hold, that is, the registers of this type can retain the data before power-down in case of power-down. 1513 +))) 1514 + 1504 1504 = **9 General Functions** = 1505 1505 ))) 1506 1506 1507 1507 ((( 1508 -== ** 9.1send_sms_ira(string number, string message)** ==1519 +== **send_sms_ira(string number, string message)** == 1509 1509 ))) 1510 1510 1511 -**Function:** 1522 +**Function:** Use IRA character set to send English text messages 1512 1512 1513 -Use IRA character set to send English text messages 1514 - 1515 1515 **Parameters:** 1516 1516 1517 1517 //number: //number (up to 32 characters, the excess will be discarded) ... ... @@ -1545,13 +1545,11 @@ 1545 1545 Failed: multi 1546 1546 1547 1547 ((( 1548 -== ** 9.3sms_get_state(number id)** ==1557 +== **sms_get_state(number id)** == 1549 1549 ))) 1550 1550 1551 -**Function:** 1560 +**Function:** Get the status of the SMS 1552 1552 1553 -Get the status of the SMS 1554 - 1555 1555 **parameter:** 1556 1556 1557 1557 //id~:// SMS corresponding id ... ... @@ -1563,13 +1563,11 @@ 1563 1563 Failed: multi 1564 1564 1565 1565 ((( 1566 -== ** 9.4jwt_encode(table head, table payload, string aud, number iat, number exp, string key, int jwttype)** ==1573 +== **jwt_encode(table head, table payload, string aud, number iat, number exp, string key, int jwttype)** == 1567 1567 ))) 1568 1568 1569 -**Function:** 1576 +**Function:** Convert data to JWT format 1570 1570 1571 -Convert data to JWT format 1572 - 1573 1573 **parameter:** 1574 1574 1575 1575 //aud: //project name ... ... @@ -1614,19 +1614,20 @@ 1614 1614 1615 1615 //key~:// the private key required for encryption 1616 1616 1617 -For example: 1622 +**For example:** 1618 1618 1624 +{{code language="LUA"}} 1619 1619 function jwt.main() 1620 1620 1621 -local PRIVATE_KEY = ~[~[~-~- Please enter the secret key~-~-]]1627 +local PRIVATE_KEY = [[-- Please enter the secret key--]] 1622 1622 1623 1623 local JWTType=0 1624 1624 1625 -local payload = ~{~{key="test1",value="test1",type="0"},1631 +local payload = {{key="test1",value="test1",type="0"}, 1626 1626 1627 1627 {key="test",value="123122131",type="1"}} 1628 1628 1629 -local head = ~{~{ key="name",value="data",type="0"},1635 +local head = {{ key="name",value="data",type="0"}, 1630 1630 1631 1631 {key="test2",value="test2",type="0"}} 1632 1632 ... ... @@ -1641,15 +1641,14 @@ 1641 1641 print(en) 1642 1642 1643 1643 End 1650 +{{/code}} 1644 1644 1645 1645 ((( 1646 -== ** 9.5convertohex(number type, number value)** ==1653 +== **convertohex(number type, number value)** == 1647 1647 ))) 1648 1648 1649 -**Function:** 1656 +**Function:** Convert data into hexadecimal data 1650 1650 1651 -Convert data into hexadecimal data 1652 - 1653 1653 **parameter:** 1654 1654 1655 1655 //type~:// incoming data type 0:word 1:dword 2:float ... ... @@ -1662,106 +1662,192 @@ 1662 1662 1663 1663 Failed: multi 1664 1664 1670 +== **crc.init(table prarm)** == 1671 + 1672 +**Function:** Initialize the CRC 1673 + 1674 +**Parameters:** 1675 + 1676 +prarm is a Lua table and needs to contain the following fields. 1677 + 1678 +* string prarm name, see table 9-1 for details of the parameter model name When this parameter is passed in, the default table parameters are used and the poly,init,xorout,refin,and refout passed in are invalid. 1679 +* number prarm.width: the width, i.e. the number of CRC bits. 1680 +* number [prarm.poly]: short for the generated item in hexadecimal. For example, CRC-32 is 0x04C11DB7, ignoring the highest bit "1", i.e., the complete generation item is 0x104C11DB7. 1681 +* number [prarm.init]: the initialization preset value of the register (crc) at the beginning of the algorithm in hexadecimal. 1682 +* number [prarm.xorout]: the final CRC value obtained after heterodyning the calculation result with this parameter. 1683 +* number [prarm.refin]: whether each byte of the data to be measured is inverted by bit, true or false. 1684 +* number [prarm.refout]: after the calculation or before the heterodyning output, whether the whole data is inverted by bit, true or false. 1685 + 1686 +Return: 1687 + 1688 +Success: crc object 1689 + 1690 +Failure: multi, error code 1691 + 1665 1665 ((( 1666 -== **9.6 set_network(table config)** == 1693 +|=Parameter model name|=poly|=init|=xorout|=refin|=refout 1694 +|crc8|0x07|0x00|0x00|false|false 1695 +|crc8_cdma2000|0x9B|0xFF|0x00|false|false 1696 +|crc8_darc|0x39|0x00|0x00|true|true 1697 +|crc8_dvb_s2|0xD5|0x00|0x00|false|false 1698 +|crc8_ebu|0x1D|0xFF|0x00|true|true 1699 +|crc8_i_code|0x1D|0xFD|0x00|false|false 1700 +|crc8_itu|0x07|0x00|0x55|false|false 1701 +|crc8_maxim|0x31|0x00|0x00|true|true 1702 +|crc8_rohc|0x07|0xFF|0x00|true|true 1703 +|crc8_wcdma|0x9B|0x00|0x00|true|true 1704 +|crc8_sae_j1850|0x1D|0xFF|0xFF|false|false 1705 +|crc8_opensafety|0x2F|0x00|0x00|false|false 1706 +|crc16_tms37157|0x1021|0x3791|0x0000|true|true 1707 +|crc16_a|0x1021|0x6363|0x0000|true|true 1708 +|crc16_riello|0x1021|0x554D|0x0000|true|true 1709 +|crc16_ccitt_false|0x1021|0xFFFF|0x0000|false|false 1710 +|crc16_arc|0x8005|0x0000|0x0000|true|true 1711 +|crc16_arc_ccitt|0x1021|0x1D0F|0x0000|false|false 1712 +|crc16_buypass|0x8005|0x0000|0x0000|false|false 1713 +|crc16_cdma2000|0xC867|0xFFFF|0x0000|false|false 1714 +|crc16_dds110|0x8005|0x800D|0x0000|false|false 1715 +|crc16_dect_r|0x0589|0x0000|0x0001|false|false 1716 +|crc16_dect_x|0x0589|0x0000|0x0000|false|false 1717 +|crc16_dnp|0x3D65|0x0000|0xFFFF|true|true 1718 +|crc16_en_13757|0x3D65|0x0000|0xFFFF|false|false 1719 +|crc16_genibus|0x1021|0xFFFF|0xFFFF|false|false 1720 +|crc16_maxim|0x8005|0x0000|0xFFFF|true|true 1721 +|crc16_mcrf4xx|0x1021|0xFFFF|0x0000|true|true 1722 +|crc16_t10_dif|0x8BB7|0x0000|0x0000|false|false 1723 +|crc16_teledisk|0xA097|0x0000|0x0000|false|false 1724 +|crc16_usb|0x8005|0xFFFF|0xFFFF|true|true 1725 +|crc16_kermit|0x1021|0x0000|0x0000|true|true 1726 + 1727 +(% class="wikigeneratedid" %) 1728 +Table 9-1 1729 + 1730 +== **crc:calc(string crcValue)** == 1731 + 1732 +**Function:** Calculate CRC result 1733 + 1734 +**Parameter:** 1735 + 1736 +crcValue: the value to be calculated 1737 + 1738 +**Return:** 1739 + 1740 +Succeed: calculated result 1741 + 1742 +Failed: multi, error code 1667 1667 ))) 1668 1668 1669 - **Function:**1745 +Example: 1670 1670 1671 -Set V-BOX network, take effect after restart 1747 +{{code language="LUA"}} 1748 +function crcTest.main() 1672 1672 1673 - **parameter:**1750 +local param = { 1674 1674 1675 - //config~:// incoming networkconfigurationtable1752 +name = '', 1676 1676 1677 -1. connectMode: the way V-BOX connects to the server, 0: Ethernet, 1: WIFI, 2: 4G, 3: 2G, it is not allowed to be empty. 1678 -1. ethernetEnable: Whether to enable Ethernet, 1: enable, 0: disable, and it is not allowed to be empty. 1679 -1. ethernetLanIp: Set the LAN IP address. Only V-BOX with three network ports support this configuration, and other models of V-BOX do not support setting LAN IP. This item is allowed to be empty. 1680 -1. ethernetIpMode: Whether to enable Ethernet static IP, 1: Enable static IP, 0: DHCP, not allowed to be empty. 1681 -1. ethernetIp: The IP address needs to be configured when the Ethernet static IP is used, and it is not allowed to be empty. 1682 -1. ethernetNetmask: The subnet mask needs to be configured when Ethernet static IP is used, and it is not allowed to be empty. 1683 -1. ethernetGateway: The gateway can be configured when Ethernet static IP is used. 1754 +width = 64, 1684 1684 1685 -1. When using the Ethernet network, if the Gateway is empty, V-BOX will not connect to the server. 1686 -1. If you only use Ethernet to directly connect to the PLC for communication, you do not need to configure a gateway. 1756 +poly = 0x42F0E1EBA9EA3693, 1687 1687 1688 -1. ethernetFirstDns: You can configure the preferred DNS server when the Ethernet static IP is used, and it is allowed to be empty. If you use the Ethernet network and do not fill in the DNS server, V-BOX will not be connected to the server. 1689 -1. ethernetSpareDns: Alternate DNS server can be configured when the Ethernet static IP is used, and it is allowed to be empty. 1690 -1. wifiEnable: Whether to enable WIFI, 1: enable, 0: disable, it is not allowed to be empty. If it is a model that does not include WIFI, directly disable it. 1691 -1. wifiName: WIFI name, if WIFI is enabled, it is not allowed to be empty. 1692 -1. wifiPassword: WIFI password, it is allowed to be empty. 1693 -1. wifiIpMode: Whether to enable WIFI static IP, 1: Enable static IP, 0: DHCP, not allowed to be empty. 1694 -1. wifiIp: IP address needs to be configured when WIFI static IP is used, it is not allowed to be empty. 1695 -1. wifiNetmask: The subnet mask needs to be configured when WIFI static IP is used, and it is not allowed to be empty. 1696 -1. wifiGateway: The gateway can be configured when WIFI static IP is used, and it is not allowed to be empty. 1697 -1. wifiFirstDns: You can configure the preferred DNS server when the WIFI static IP is used, and it is allowed to be empty. If you use the WIFI network and do not fill in the DNS server, V-BOX will not be connected to the server. 1698 -1. wifiSpareDns: Alternate DNS server can be configured when the WIFI static IP is used, and it is allowed to be empty. 1699 -1. mobileEnable: Whether to enable the mobile network, 1: enable, 0: disable, it is not allowed to be empty, if it does not include 4G models, directly disable it. 1700 -1. mobileApnMode: Whether to manually configure the APN, 0: Use the default APN, 1: Manually configure the APN, it is not allowed to be empty. 1701 -1. apnName: APN name, if you choose to manually configure APN, it is not allowed to be empty. 1702 -1. apnPassword: APN username, it is allowed to be empty. 1703 -1. apnUserName: APN number, it is allowed to be empty. 1704 -1. apnNumber: APN number, it is allowed to be empty. 1758 +init = 0xFFFFFFFFFFFFFFFF, 1705 1705 1706 - **Return:**1760 +xorout = 0xFFFFFFFFFFFFFFFF, 1707 1707 1708 - Succeed: true1762 +refin = 1, 1709 1709 1710 - Faied: multi1764 +refout = 1 1711 1711 1712 -((( 1713 -== **9.7 remote_com_start(string config)** == 1714 -))) 1766 +} 1715 1715 1716 - **Function:**1768 +crc64,err = crc.init(param) 1717 1717 1718 - start serialportpass-through1770 +if not crc64 then 1719 1719 1720 -**Parameter:** 1772 +print("Crc init failed:", err) 1773 +else 1721 1721 1722 - //config: //incoming serialport parameterconfiguration, JSON format1775 +crcvalue = crc64:calc("123456789") 1723 1723 1724 -1. type:0, serial port pass-through 1725 -1. port: serial port number marked on the V-BOX 1726 -1. comtype:0-RS232, 1-RS485, 2-RS422 1727 -1. baudrate: Baud Rate 1728 -1. data_length: Data Bits 1729 -1. stop_bit: Stop Bit 1730 -1. check_bit: Check Bit 1777 +print(string.format("crc64 calc :0X%16X", crcvalue)) 1731 1731 1779 +end 1780 + 1781 +end 1782 +{{/code}} 1783 + 1784 += **10 Special function for V-NET** = 1785 + 1786 +== **normal_get_alldata()** == 1787 + 1788 +**Function: **Obtain the data of all the monitoring points 1789 + 1790 +**Parameter: None** 1791 + 1732 1732 **Return:** 1733 1733 1734 -Succeed: t rue1794 +Succeed: table two-dimensional arrays, as follows: 1735 1735 1736 -Failed: multi 1796 +* Each item is a monitoring point and contains 4 attributes: 1797 +** 1: ID 1798 +** 2: status 1799 +** 3: tag name 1800 +** 4: value 1801 +* Status contains 3 enumerated values 1802 +** 0: offline 1803 +** 1: online 1804 +** 2: timeout 1805 +* Customization returns an empty table if there is no configuration, otherwise returns "field name/field content" 1737 1737 1738 -((( 1739 -== **9.8 remote_com_stop()** == 1740 -))) 1807 +For example: 1741 1741 1742 - **Function:**1809 +{ 1743 1743 1744 - closeserialportpass-through1811 +[1]= {[1]=1234, [2]=1, [3]='temp', [4]='23.5'}, 1745 1745 1813 +[2]= {[1]=1235, [2]=1, [3]='humi', [4]='67'}, 1814 + 1815 +... 1816 + 1817 +[n]= {[1]=xxxx, [2]=x, [3]='xxxx', [4]='xx.x'}, 1818 + 1819 +} 1820 + 1821 +Failed: table, empty table 1822 + 1823 +== **normal_setdata_byname(string name, string data)** == 1824 + 1825 +**Function:** Write data to the monitoring point name 1826 + 1827 +**Parameter:** 1828 + 1829 +name: the name of monitoring point 1830 + 1831 +data: the data to be written 1832 + 1746 1746 **Return:** 1747 1747 1748 -Succeed: true 1835 +Succeed: string: The value of the monitor point before it is written 1749 1749 1750 -Failed: m ulti1837 +Failed: mil 1751 1751 1752 -((( 1753 -== **9.9 remote_com_state()** == 1754 -))) 1839 +== **normal_getdata_byname(string name)** == 1755 1755 1756 -**Function:** 1757 1757 1758 - querytheserialportpass-throughstatus and pass-throughserver domain nameand port1842 +**Function:** Read the data of the monitoring point name 1759 1759 1844 +**Parameter:** 1845 + 1846 +name: the name of monitoring point 1847 + 1760 1760 **Return:** 1761 1761 1762 -Succeed: 1850 +Succeed: string 1763 1763 1764 -1. number, current pass-through status: 0-none 1,2-starting pass-through 3-penetrating 4,5-finishing pass-through 6-pass-through error 1765 -1. string, pass-through server domain name and port number, xxxx (domain name): xxx (port number) 1852 +Failed: mil 1766 1766 1767 -Failed: multi 1854 += **11 MySQL database operation** = 1855 + 1856 +== **luaMySql.init(string sourcename, string username, string password, string host, number port, string character)** == 1857 + 1858 +